Miniature Relay DS2Y RELAYS FEATURES TYPICAL APPLICATIONS 1. 2 Form C contact 2. High sensitivity-200 mW nominal operating power 3. High breakdown voltage 1500 V FCC surge between open contacts 4. DIP-2C type matching 16 pin IC socket 5. Sealed construction 1. Telecommunication equipment 2. Office equipment 3. Computer peripherals 4. Security alarm systems 5. Medical equipment RoHS compliant ORDERING INFORMATION DS2Y-S Operating function Nil: Single side stable Nominal coil voltage DC 3, 5, 6, 9, 12, 24, 48 V Note: UL/CSA approved type is standard. TYPES Contact arrangement Nominal coil voltage 2 Form C 3 V DC 5 V DC 6 V DC 9 V DC 12 V DC 24 V DC 48 V DC Single side stable type Part No. DS2Y-S-DC3V DS2Y-S-DC5V DS2Y-S-DC6V DS2Y-S-DC9V DS2Y-S-DC12V DS2Y-S-DC24V DS2Y-S-DC48V Standard packing: Tube: 50 pcs.; Case: 500 pcs. -1- ASCTB16E 201407-T DS2Y RATING 1. Coil data Single side stable type 3 V DC Nominal operating current [10%] (at 20C 68F) 66.7 mA 5 V DC 6 V DC 9 V DC 12 V DC 24 V DC 48 V DC 40 mA 33.3 mA 22.2 mA 16.7 mA 8.3 mA 6.3 mA Nominal coil voltage Pick-up voltage (at 20C 68F) 70%V or less of nominal voltage (Initial) Drop-out voltage (at 20C 68F) 10%V or more of nominal voltage (Initial) Coil resistance [10%] (at 20C 68F) Nominal operating power Max. applied voltage (at 50C 122F) 200 mW 200%V of nominal voltage 45 125 180 405 720 2,880 7,680 300 mW 2. Specifications Characteristics Contact Rating Item Arrangement Initial contact resistance, max. Contact material Max. switching power Max. switching voltage Max. switching current Max. carrying current Minimum operating power Nominal operating power Insulation resistance (Initial) Between open contacts Between contact sets Between contact and coil FCC surge breakdown voltage between contacts and coil Temperature rise (at 20C 68F) Breakdown voltage (Initial) Electrical characteristics Operate time [Set time] (at 20C 68F) Release time [Reset time] (at 20C 68F) Functional Destructive Functional Vibration resistance Destructive Mechanical Electrical Shock resistance Mechanical characteristics Expected life Conditions Conditions for operation, transport and storage* Max. operating speed (at rated load) Unit weight Specifications 2 Form C Max. 50 m (By voltage drop 6 V DC 1A) Ag+Au clad 60 W, 62.5 VA (resistive load) 220 V DC, 250 V AC 2A 3A Approx. 98 mW (147 mW: 48 V) Approx. 200 mW (300 mW: 48 V) Min. 100M (at 500V DC) Measurement at same location as "Initial breakdown voltage" section. 750 Vrms for 1min. (Detection current: 10mA.) 1,000 Vrms for 1min. (Detection current: 10mA.) 1,000 Vrms for 1min. (Detection current: 10mA.) 1,500 V Max. 65C with nominal coil voltage across coil and at nominal switching capacity Approx. 4 ms [approx. 3 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.) Approx. 3 ms [approx. 3 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode) Min. 490 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10s.) Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.) 10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10s.) 10 to 55 Hz at double amplitude of 5 mm Min. 108 Min. 5x105 (1 A 30 V DC), Min. 105 (2 A 30 V DC) Ambient temperature: -40C to +70C -40F to +158F Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) 60 cpm Approx. 4g .14oz Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. TX/TX-S/TX-D relay AgPd contact type are available for low level load switching (10V DC, 10mA max. level). *2 Half-wave pulse of sine wave: 11ms; detection time: 10s *3 Refer to "AMBIENT ENVIRONMENT" in GENERAL APPLICATION GUIDELINES. -2- ASCTB16E 201407-T DS2Y REFERENCE DATA 1. Maximum switching capacity 2. Coil temperature rise (Single side stable) Tested sample: DS2Y-S-DC12V, 5 pcs. Measured portion: Inside the coil Ambient temperature: 21C to 25C 70F to 77F 3. Operate/release time for single side stable (Without diode) Tested sample: DS2Y-S-DC12V, 10 pcs. Ambient temperature: 20C 68F 1,000 V 5 Operate time Release time 100 V 10 V 4 Time, ms Temperature rise, C Contact voltage 3A 30 2A 0A 3 Mean value Mean value 2 20 1 10 mA 10 A 100 mA 100 1A Switching current 0 110 Coil applied voltage, %V 4-(2) Influence of adjacent mounting Tested sample: DS2Y-S-DC12V, 10 pcs. Ambient temperature: 20C 68F Tested sample: DS2Y-S-DC12V, 10 pcs. Ambient temperature: 20C 68F TEST METHOD 1. Apply nominal voltage to No. (1) and (3) DS2Y relays. 2. Measure pick-up voltage and drop-out voltage of No. (2) relay when inter-relay distance ( ) changes. TEST METHOD 1. Apply nominal voltage to No. (1) and (3) DS2Y relays. 2. Measure pick-up voltage and drop-out voltage of No. (2) relay when inter-relay distance ( ) changes. (1) OFF 10 (2) (3) OFF Pick-up/Drop-out voltage, V Pick-up/Drop-out voltage, V 4-(1) Influence of adjacent mounting 8 ON ON Pick-up voltage 6 OFF OFF 4 Drop-out voltage ON ON 2 80 100 120 Coil applied voltage, %V 10 (1) OFF (2) (3) OFF 8 Pick-up voltage ON ON OFF OFF ON ON 6 4 Drop-out voltage 2 0 0 5 10 15 .197 .394 .591 Inter-relay distance, mm inch DIMENSIONS (mm inch) 5 10 15 .197 .394 .591 Inter-relay distance, mm inch The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/ Single side stable CAD Data External dimensions PC board pattern (Copper-side view) (Deenergized position) 8-0.9 dia. 8-.035 dia. 9.9 .390 20 .787 2.54 .100 9.3 .366 5.08 5.08 .200 .200 7.62 .300 2.0 .078 0.6 .024 5.6 .220 7.62 .300 9 13 11 N.O. N.C. COM 16 - N.O. N.C. COM 8 6 4 + 1 2.54 .100 0.6 .024 0.6 .024 Schematic (Bottom view) 3.4 .134 7.62 .300 0.3 .012 matching 16 pin IC socket Tolerance: 0.1 .004 Direction indication* *A polarity bar shows the relay direction. General tolerance: 0.3 .012 For general cautions for use, please refer to the "Cautions for use of Signal Relays" or "General Application Guidelines". -3- ASCTB16E 201407-T