Applications
• Computers and peripherals
• HDTV Equipment
• DVD Players
• A/V Equipment
• Satellite radio
• Cell phones
• PDAs
• Digital still cameras
• Digital camcorders
• MP3/Multimedia players
• Set top boxes
• External storage
• DSL Modems
• High speed data ports
• USB 2.0/3.0
• IEEE 1394b
• HDMI 1.3
• DVI
• High speed ethernet
• Infiniband®
Part Numbering System: 0402 ESDA MLP 1
Package Size
Product Family
Form Designation
Designation for Dip Termination
Packaging
• 10,000 suppressors on paper tape in seven inch (178mm) plastic reel
per EIA Standard 481-1.
Ordering Information
MLP1 ESD Suppressor
PolySurg™0402ESDA-MLP1
1010 BU-SB101153 Page 1 of 2 Data Sheet 4367
Surface Mount Device
Description
The Cooper Bussmann PolySurg™0402ESDA-MLP1 ESD Suppressors
protect valuable high-speed data circuits from ESD damage without distorting
data signals as a result of its ultra-low (0.05pF typical) capacitance.
Features
• Halogen free
• RoHS compliant for global applications
• Lead free
• Ultra-low capacitance (0.05pF typ.) ideal for high speed data
applications
• Provides ESD protection with fast response time (<1ns) allowing
equipment to pass IEC 61000-4-2 level 4 test
• Single-line, bi-directional device for placement flexibility
• Low profile 0402/1005 design for board space savings
• Low leakage current (<0.1nA typ.) reduces power consumption
• (Sn) Tin-plated version available
Catalog Number Description
0402ESDA-MLP1 10,000 pieces on paper tape on 7" (178mm) reel - tin plating
Specifications
Characteristic Value
Rated Voltage 30Vdc maximum
Clamping Voltage135V typical
Trigger Voltage2300V typical
Capacitance (@1MHz) 0.05pF typical, 0.15pF maximum
Attenuation Change (0-6GHz) -0.2dB typical
Leakage Current (@12Vdc) <0.1nA typical
ESD Capability
• IEC61000-4-2 Direct Discharge 8kV typical
• IEC61000-4-2 Air Discharge 15kV typical
ESD Pulse Withstand3>1000 typical
1 Per IEC61000-4-2, Level 4 waveform (8kV direct, 30A) measured 30ns after initiation of pulse.
2 Trigger measurement made using Transmission Line Pulse (TLP) method.
3 Minor shifting in characteristics may be observed over multiple ESD pulses at very rapid rate
Design Considerations
The location in the circuit for the MLP series has to be carefully determined.
For better performance, the device should be placed as close to the signal
input as possible and ahead of any other component. Due to the high current
associated with an ESD event, it is recommended to use a “0-stub” pad
design (pad directly on the signal/data line and second pad directly on
common ground).