Keysight U1210 Series Handheld Clamp Meters Handle big currents - more safely Data Sheet Introduction Measurements of electrical distribution cables can be challenging and risky. For cables up to two inches in diameter, the Keysight Technologies, Inc. U1210 Series handheld clamp meters enable highcurrent measurements without breaking the circuit. Unlike most clamp meters, they also include DMM capabilities--resistance, capacitance, frequency and temperature--to simplify troubleshooting during installation and maintenance. Best of all, they provide an extra layer of protection with CAT IV 600V and CAT III 1000 V safety ratings. Features - - - - - - - - - - Large clamp opening of 52 mm or 2" High measurement capability of up to 1000 A for AC, DC or AC+DC CAT III 1000 V/CAT IV 600 V safety rating Bluetooth(R) wireless connectivity (optional U1177A Infrared (IR)-to-Bluetooth Adapter required) Includes full-featured DMM with resistance, capacitance, frequency and temperature functions High resolution measurements - measure current as low as 0.01 mA Peak hold Dual ranging mode - manual and auto Large dual display Min/max recording capability Key Measurements Measure current easily and accurately Keysight U1210 Series handheld clamp meters come with clamp opening of 52 mm/2 inches and high current measurement capability of up to 1000 A (AC, DC, AC+ DC). With the large jaw size, these handhelds simplify current measurements for thick cables. Clamp on with the U1210 Series and get convenience, versatility and the ability to handle big currents--safely. Full-featured digital multimeter functions The U1210 Series handheld clamp meters provide basic functions of a multimeter with wide measurement ranges to cater for a broad range of applications (ACA, DCV, ACV, OHM, audible continuity, diode and frequency tests). These meters also provide auto-ranging capability, built-in peak hold for in-rush current measurement, temperature and capacitance measurement capability, large backlight display and one-hand operation. Smooth sailing measurements even in a distance Making current measurements can be strenuously demanding due to its complexity and high current involved. Electrical distribution rooms being typically situated at different areas further complicates maintenance and troubleshooting due to the need to commute back and forth to cross check measurement results. By adding the new Bluetooth capability to your existing U1210 series handheld clamp meters, you are able to make high current measurements in a safer and more convenient manner. With the U1177A Infrared-to-Bluetooth adapter, you can easily monitor measurements and log data up 10-metres range across all Android platform devices-- 3 an added value for maximum efficiency and productivity in all sorts of hard-to-reach environments. Take a Closer Look Large jaw opening of 2 inches to test thick current sources Capacitance/Diode measurement Max or Min recording capability Temperature and audible continuity functions High measurement capability of up to 1000 A for AC, DC or AC+DC Large LCD display with maximum reading of 4000 counts Peak hold function for in-rush current testing Manual or auto ranging 4 General Speciications Title Speciication Dimension - U1211A: 106 mm (W) X 273 mm (L) X 43 mm (H) - U1212A and U1213A: 106 mm (W) X 260 mm (L) X 43 mm (H) Net Weight - U1211A: 625 grams with batteries included - U1212A and U1213A: 525 grams with batteries included Display 4 digits with maximum reading 4,100 counts. The 12 Segments analog bar graph and full annunciator. Automatic polarity indication. Battery Standard 9 V Battery - Alkaline Low battery indicator Battery voltage drops below 6.0 V Power consumption - U1211A: 186 mVA maximum - U1212A and U1213A: 220 mVA maximum Battery life 60 hours (typical) Connectivity Wireless Bluetooth compatible Maximum jaw opening ~2 inches Temperature coefficient 0.12 x (specified accuracy)/C (from 0 to 18 C or 28 to 50 C) NMRR (Normal Mode Rejection Ratio) This series has a NMRR specification of > 60 dB at 50 Hz and 60 Hz, which means a good ability to reject the effect of AC noise in DC measurement CMRR (Common Mode Rejection Ratio) - U1211A and U1212A have CMRR specifications of > 60 dB at DC to 60 Hz in the ACV function; and > 80 dB at DC, 50 Hz and 60 Hz in the DCV function. - U1213A has a CMRR specifications of > 60 dB at DC to 60 Hz in the ACV function; and > 120 dB at DC, 50 Hz and 60 Hz in the DCV function. Operating temperature -10 to 50 C, 0 to 80 % R.H. Storage temperature -20 to 60 C, 0 to 80 % R.H. Relative Humidity (R.H.) Maximum 80 % R.H. for temperature up to 31 C decreasing linearly to 50 % R.H. at 50 C Temperature coefficient 0.1 x (specified accuracy) / C (from 0 C to 18 C or 28 C to 50 C) Safety compliance EN/IEC 61010-1:2001, ANSI/UL 61010-1:2004, and CAN/CSA-C22.2 No.61010-1-04 Measurement category CAT III 1000 V/ CAT IV 600 V EMC compliance - - - - Certified to IEC61326-1:2005/ EN61326-1:2006 CISPR 11:2003/ EN 55011:2007 Group 1 class A Canada: ICES-001:2004 Australia/New Zealand: AS/NZS CISPR11:2004 5 Electrical Speciications for U1211A Accuracy is given as (% of reading + number of least significant digits) at 23 C 5 C, with relative humidity less than 80 % R.H. ACV/ ACA specifications are ac coupled, true R.M.S. and are valid from 5 % of range to 100 % of range. The crest factor may be up to 3.0 at full-scale except the 1000 V and 1000 A ranges where these are 1.5 at full scale. For non-sinusoidal waveforms, add (2 % reading + 2 % full scale) typical, for crest factors up to 3. DC voltage Range Resolution Accuracy 400 V 0.1 V 0.5 % + 5 1000 V 1V 0.5 % + 3 Overload protection 1000 V R.M.S - Input impedance: 10 M (nominal) AC voltage Accuracy Range Resolution 400 V 0.1 V 1%+5 1000 V 1V 1%+5 45~400 Hz Overload protection 1000 V R.M.S - Input impedance: 10 M (nominal) in parallel with < 100 pF Voltage (1 ms peak hold) Range Resolution Accuracy 400 V 0.1 V 1 % + 43 1000 V 1V 1 % + 43 Overload protection 1000 V R.M.S - Specified accuracy for changes > 1 ms in duration Diode check/audible continuity test Range Resolution Accuracy Test current Open voltage Diode 0.001 V 0.5 % + 2 Approximately 0.8 mA < +3.1 V - Overload protection: 1000 V R.M.S. for circuits < 0.3 A of short circuit current - Built-in buzzer sounds when reading is below 50 mV approximately and single tone for normal forward-biased diode or semiconductor junction as 0.3 V Reading 0.8 V Resistance Range Resolution Accuracy Test current 400 0.1 0.5 % + 3 0.8 mA 4 k 0.001 k 0.5 % + 3 80 A Notes: 1. Overload protection: 1000 V R.M.S. for circuits < 0.3 A of short circuit current 2. Maximum open voltage: < +3.1 V 3. Instant continuity: Built-in buzzer sounds when resistance is less than 10.0 4. The accuracy of 400 and 4 k is specified after Relative function, which is used to substrate the test lead resistance and the thermal effect 6 Electrical Speciications for U1211A (continued) Capacitance Range Resolution Accuracy Overload protection 400 F 0.1 F 2%+4 4000 F 1 F 3%+4 1000 V R.M.S. for circuits < 0.3 A of short circuit current - The accuracy is based on film capacitor or better and use Relative mode to zero residual value AC current Range Resolution Accuracy *N1 45~65 Hz 65~400 Hz 400 Hz~1 kHz 40 A 0.01 A 1.0 % + 10 1.0 % + 10 3.0 % + 10 400 A 0.1 A 1.0 % + 5 1.0 % + 5 3.0 % + 5 400~700 A 1A 1.0 % + 5 1.0 % + 5 3.0 % + 5 700~1000 A 1A 1.0 % + 5 None None - Maximum overload: 1000 A R.M.S. The accuracy is specified on the symmetrical waveforms. - N1: The maximum verification of current and frequency product is less than 400,000 A x Hz WARNING: The measuring duty cycle should not exceed the following limits. 0 ~ 600 A R.M.S. Continuous 600 ~ 700 A R.M.S. 10 minutes ON, 10 minutes OFF 700 ~ 1000 A R.M.S. 5 minutes ON, 20 minutes OFF Current (1 ms peak hold) Range Resolution Accuracy 40 A 0.01 A 2.0 % + 70 400 A 0.1 A 2.0 % + 43 1000 A 1A 2.0 % + 43 - Specified accuracy for changes > 1 ms in duration 7 Maximum overload 1000 A R.M.S. Electrical Speciications for U1211A (continued) Frequency (AC coupling) Range Resolution 99.99 Hz 0.01 Hz 999.9 Hz 0.1 Hz 9.999 kHz 0.001 kHz 99.99 kHz 0.01 kHz 999.9 kHz 0.1 kHz Accuracy Minimum frequency 0.2 % + 3 10 Hz - Overload protection: 1000 V; < 20,000,000 V x Hz Sensitivity Frequency sensitivity Range Minimum sensitivity (R.M.S.) Maximum input for speciied accuracy of AC 40 Hz~2 kHz 10~40 Hz or 2~100 kHz 400 V 6V 6V 1000 V 20 V 30 V (< 10 kHz) 40 A 3 A (< 1 kHz) 3 A (< 1 kHz) 400 A 20 A (< 1 kHz) 20 A (< 1 kHz) 1000 A 50 A (1 kHz) 50 A (< 1 kHz) 8 Electrical Speciications for U1212A Accuracy is given as (% of reading + number of least significant digits) at 23 C 5 C, with relative humidity less than 80 % R.H. ACV/ ACA specifications are ac coupled, true R.M.S. and are valid from 5 % of range to 100 % of range. The crest factor may be up to 3.0 at full-scale except the 1000 V and 1000 A ranges where these are 1.5 at full scale. For non-sinusoidal waveforms, add (2 % reading + 2 % full scale) typical, for crest factors up to 3. DC voltage Range Resolution Accuracy 400 V 0.1 V 0.5 % + 3 1000 V 1V 0.5 % + 3 Overload protection 1000 V R.M.S - Input impedance: 10 M (nominal) AC voltage Accuracy Range Resolution 400 V 0.1 V 1%+5 1000 V 1V 1%+5 45~400 Hz Overload protection 1000 V R.M.S - Input impedance: 10 M (nominal) in parallel with < 100 pF Voltage (1 ms peak hold) Range Resolution Accuracy 400 V 0.1 V 1 % + 43 1000 V 1V 1 % + 43 Overload protection 1000 V R.M.S - Specified accuracy for changes > 1 ms in duration Diode check/audible continuity test Range Resolution Accuracy Test current Open voltage Diode 0.001 V 0.5 % + 2 Approximately 0.8 mA < +3.1 V - Overload protection: 1000 V R.M.S. for circuits < 0.3 A of short circuit current - Built-in buzzer sounds when reading is below 50 mV approximately and single tone for normal forward-biased diode or semiconductor junction as 0.3 V Reading 0.8 V Resistance Range Resolution Accuracy Test current 400 0.1 0.5 % + 3 0.8 mA 4 k 0.001 k 0.5 % + 3 80 A Notes: 1. Overload protection: 1000 V R.M.S. for circuits < 0.3 A of short circuit current 2. Maximum open voltage: < +3.1 V 3. Instant continuity: Built-in buzzer sounds when resistance is less than 10.0 4. The accuracy of 400 and 4 k is specified after Relative function, which is used to substrate the test lead resistance and the thermal effect 9 Electrical Speciications for U1212A (continued) Capacitance Range Resolution Accuracy Overload protection 400 F 0.1 F 2%+4 4000 F 1 F 3%+4 1000 V R.M.S. for circuits < 0.3 A of short circuit current - The accuracy is based on film capacitor or better and use Relative mode to zero residual value DC current Range Resolution Accuracy Maximum overload 40 A 0.01 A 1.5 % + 15 400 A 0.1 A 1.5 % + 3 1000 A 1A 2.0 % + 5 1000 A R.M.S. - Use Relative mode to zero residual offset AC current Accuracy *N1 Range Resolution 45~65 Hz 65 Hz~1 KHz 40 A 0.01 A 2.0 % + 10 3.0 % + 10 400 A 0.1 A 2.0 % + 5 3.0 % + 5 1000 A 1A 2.0 % + 5 3.0 % + 5 Maximum overload 1000 A R.M.S. - N1: The maximum verification of current and frequency product is less than 400,000 A x Hz Current (1 ms peak hold) Range Resolution Accuracy 40 A 0.01 A 2.0 % + 70 400 A 0.1 A 2.0 % + 43 1000 A 1A 2.0 % + 43 Maximum overload 1000 A R.M.S. - Specified accuracy for changes > 1 ms in duration Temperature test Thermal type K Range Resolution Accuracy -200 ~ -40 C 0.1 C 1 % + 3 C -40 ~ 1372 C 0.1 C 1 % + 1 C -328 ~ -40 F 0.1 F 1 % + 6 F -40 ~ 2502 F 0.1 F 1 % + 2 F Notes: 1. The accuracy does not include the tolerance of the thermocouple probe, and the meter must be operational for at least one hour 2. Do not allow the temperature sensor to contact a surface that is energized above 33 V R.M.S. or 70 V DC. Such voltages will pose a shock hazard. 3. The temperature calculation is according to the standard of EN/IEC-60548-1 and NIST175 10 Electrical Speciications for U1212A (continued) Frequency (AC coupling) Range Resolution 99.99 Hz 0.01 Hz 999.9 Hz 0.1 Hz 9.999 kHz 0.001 kHz 99.99 kHz 0.01 kHz 999.9 kHz 0.1 kHz Accuracy Minimum frequency 0.2 % + 3 10 Hz - Overload protection: 1000 V Sensitivity Frequency sensitivity Range Minimum sensitivity (R.M.S.) Maximum input for speciied accuracy of AC 40 Hz~2 kHz 10~40 Hz or 2~100 kHz 400 V 6V 6V 1000 V 20 V 30 V (< 10 kHz) 40 A 3 A (< 1 kHz) 3 A (< 1 kHz) 400 A 20 A (< 1 kHz) 20 A (< 1 kHz) 1000 A 50 A (1 kHz) 50 A (< 1 kHz) 11 Electrical Speciications for U1213A Accuracy is given as (% of reading + number of least significant digits) at 23 C 5 C, with relative humidity less than 80 % R.H. AC voltage, AC current, AC+DC voltage, AC+DC current specifications are ac coupled, true R.M.S. and are valid from 5 % of range to 100 % of range. The crest factor may be up to 3.0 at full-scale except the 1000 V and 1000 A ranges where these are 1.5 at full scale. For non-sinusoidal waveforms, add (2 % reading + 2 % full scale) typical, for crest factors up to 3. DC voltage Range Resolution 4V 0.001 V 40 V 0.01 V 400 V 0.1 V 1000 V 1V Accuracy Overload protection 0.2 % + 5 1000 A R.M.S. 0.5 % + 3 - Input impedance: 10 M (nominal) AC voltage Accuracy Range Resolution 4V 0.001 V 40 V 0.01 V 400 V 0.1 V 1000 V 1V 45~400 Hz 400 Hz~2 kHz Overload protection 1.0 % + 5 2.0 % + 5 1000 V R.M.S 45~400 Hz 400 Hz~2 kHz Overload protection 1.5 % + 9 2.5 % + 9 1000 V R.M.S - Input impedance: 10 M (nominal) in parallel with < 100 pF AC+DC voltage Accuracy Range Resolution 4V 0.001 V 40 V 0.01 V 400 V 0.1 V 1000 V 1V - Input impedance: 10 M (nominal) in parallel with < 100 pF Voltage (1 ms peak hold) Range Resolution 4V 0.001 V 40 V 0.01 V 400 V 0.1 V 1000 V 1V - Specified accuracy for changes > 1 ms in duration 12 Accuracy Overload protection 1.0 % + 43 1000 V R.M.S Electrical Speciications for U1213A (continued) Diode check/audible continuity test Range Resolution Accuracy Test current Open voltage Diode 0.001 V 0.5 % + 2 Approximately 0.8 mA < +3.1 V - Overload protection: 1000 V R.M.S. for circuits < 0.3 A of short circuit current - Built-in buzzer sounds when reading is below 50 mV approximately and single tone for normal forward-biased diode or semiconductor junction as 0.3 V Reading 0.8 V Resistance Range Resolution 400 0.1 Accuracy Test current 4 k 0.001 k 40 k 0.01 k 400 k 0.1 k 4 M 0.001 M 0.6 % + 3 112 nA 40 M 0.01 M 2.0 % + 5 112 nA 0.8 mA 0.3 % + 3 80 A 8 A 727 nA Notes: 1. Overload protection: 1000 V R.M.S. for circuits < 0.3 A of short circuit current 2. Maximum open voltage: < +3.1 V 3. Instant continuity: Built-in buzzer sounds when resistance is less than 10.0 4. The accuracy of 400 and 4 k is specified after Relative function, which is used to substrate the test lead resistance and the thermal effect Capacitance Range Resolution 4 F 0.001 F Accuracy 40 F 0.01 F 400 F 0.1 F 2%+4 4000 F 1 F 3%+4 Overload protection 1%+4 1000 V R.M.S. for circuits < 0.3 A of short circuit current - The accuracy is based on film capacitor or better and use Relative mode to zero residual value DC current Range Resolution Accuracy 40 A 0.01 A 1.5 % + 15 400 A 0.1 A 1.5 % + 3 1000 A 1A 2.0 % + 5 - Use Relative mode to zero residual offset 13 Maximum overload 1000 A R.M.S. Electrical Speciications for U1213A (continued) AC current Accuracy *N1 Range Resolution 45~65 Hz 65 Hz~1 KHz 40 A 0.01 A 2.0 % + 10 3.0 % + 10 400 A 0.1 A 2.0 % + 5 3.0 % + 5 1000 A 1A 2.0 % + 5 3.0 % + 5 Maximum overload 1000 A R.M.S. - N1: The maximum verification of current and frequency product is less than 400,000 A x Hz AC+DC current Accuracy Range Resolution 45~65 Hz 65 Hz~1 kHz 40 A 0.01 A 3.5 % + 25 4.5 % + 25 400 A 0.1 A 3.5 % + 9 4.5 % + 9 1000 A 1A 4.5 % + 9 5.0 % + 9 Maximum overload 1000 A R.M.S. Current (1 ms peak hold) Range Resolution Accuracy 40 A 0.01 A 2.0 % + 70 400 A 0.1 A 2.0 % + 43 1000 A 1A 2.0 % + 43 Maximum overload 1000 A R.M.S. - Specified accuracy for changes > 1 ms in duration Temperature test Thermal type K Range Resolution Accuracy -200 ~ -40 C 0.1 C 1 % + 3 C -40 ~ 1372 C 0.1 C 1 % + 1 C -328 ~ -40 F 0.1 F 1 % + 6 F -40 ~ 2502 F 0.1 F 1 % + 2 F Notes: 1. The accuracy does not include the tolerance of the thermocouple probe, and the meter must be operational for at least one hour 2. Do not allow the temperature sensor to contact a surface that is energized above 33 V R.M.S. or 70 V DC. Such voltages will pose a shock hazard. 3. The temperature calculation is according to the standard of EN/IEC-60548-1 and NIST175 14 Electrical Speciications for U1213A (continued) Frequency (AC coupling) Range Resolution 99.99 Hz 0.01 Hz 999.9 Hz 0.1 Hz 9.999 kHz 0.001 kHz 99.99 kHz 0.01 kHz 999.9 kHz 0.1 kHz Accuracy Minimum frequency 0.2 % + 3 10 Hz - Overload protection: 1000 V; < 20,000,000 V x Hz Sensitivity Frequency sensitivity Range Minimum sensitivity (R.M.S.) Maximum input for speciied accuracy of AC 45 Hz~2 kHz 10 Hz~200 kHz 4V 0.3 V 0.6 V 40 V 2V 3V 400 V 20 V 30 V (< 100 kHz) 1000 V 50 V 50 V (< 10 kHz) 40 A 3 A (< 1 kHz) 3 A (< 1 kHz) 400 A 20 A (< 1 kHz) 20 A (< 1 kHz) 1000 A 50 A (< 1 kHz) 50 A (< 1 kHz) Duty cycle Mode Range Accuracy of full scale AC coupling 0.1 %~99.9 % 0.3 % per kHz + 0.3 % Notes: 1. The accuracy for duty cycle is based on a 4 V square wave input to the DC 4 V range and maximum frequency up to 2 kHz. The duty cycle range can be measured within 5 %~95 % as the signal frequency > 20 Hz. 15 Ordering Information Standard shipped accessories - - - - - Test leads 4-mm probes Soft carrying case Quick Start Guide Certificate of Calibration (CoC) Optional accessories U1168A Standard test lead kit U1162A Alligator clips U1175A Soft carrying case U1186A K-type thermocouple and adapter U1177A Infrared (IR)-to-Bluetooth Adapter Did you know? Ensure that the clamp meter measures only one conductor at a time. Measuring multiple conductors may cause inaccuracy in measurement reading due to vector sum of the currents flowing in the conductors. 16 17 | Keysight | U1210 Series Handheld Clamp Meters - Data Sheet myKeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. www.lxistandard.org LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems. Keysight is a founding member of the LXI consortium. www.keysight.com/quality Keysight Electronic Measurement Group DEKRA Certified ISO 9001:2008 Quality Management System Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight's measurement expertise and product breadth, combined with channel partner convenience. Bluetooth and Bluetooth Logo are registered trademarks owned by Bluetooth SIG, Inc., U.S.A. and licensed to Keysight Technologies, Inc. www.keysight.com/find/clampmeter For more information on Keysight Technologies' products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada Brazil Mexico United States (877) 894 4414 55 11 3351 7010 001 800 254 2440 (800) 829 4444 Asia Paciic Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Other AP Countries 1 800 629 485 800 810 0189 800 938 693 1 800 112 929 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 (65) 6375 8100 Europe & Middle East Austria Belgium Finland France Germany Ireland Israel Italy Luxembourg Netherlands Russia Spain Sweden Switzerland United Kingdom 0800 001122 0800 58580 0800 523252 0805 980333 0800 6270999 1800 832700 1 809 343051 800 599100 +32 800 58580 0800 0233200 8800 5009286 0800 000154 0200 882255 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-05-23-14) This information is subject to change without notice. (c) Keysight Technologies, 2012 - 2104 Published in USA, August 2, 2014 5990-5083EN www.keysight.com