Solid State Relays G3TA CSM_G3TA_DS_E_4_1 I/O SSRs That Mount to OMRON's G7TC I/O Block * Input and output modules are available in wide variety. * Snaps easily into P7TF I/O Terminals and can be used together with G7T I/O relays. * Operation of each SSR can be monitored easily through an LED indicator. * Models certified for UL and CSA added to the series ("-US" models). Refer to Safety Precautions for All Solid State Relays. Model Number Structure Model Number Legend G3TA@@@@@@@-@ 1 2 3 4 5 6 7 8 9 10 1. Basic Model Name G3T: I/O Solid State Relay 2. Structure A: Socket type for PCB 3. I/O I: Input models O: Output models 4. Type A: Input models: AC input Output models: AC output D: Input models: DC input Output models: DC output 5. Rated Load Power Supply Voltage 2: 200 VAC/200 VDC X: 50 to 100 V Z: 26 V max. 6. Rated Load Current 01: 1A 02: 2A R02: 25 mA 7. Terminal Type S: Plug-in terminals 8. Zero Cross Function Blank: DC output models Z: Equipped with zero cross function L: Not equipped with zero cross function 9. Operation Indicator Blank: Equipped with operation indicator M: Not equipped with operation indicator 10.Certification US: Certified by UL and CSA Ordering Information List of Models Input Modules Isolation Indicator Logic level Supply voltage Photocoupler Yes 4 to 32 VDC No Rated input voltage Model Supply current 25 mA 100 to 240 VAC G3TA-IAZR02S-US 5 to 24 VDC G3TA-IDZR02S-US 4 to 24 VDC G3TA-IDZR02SM-US Note: When ordering, specify the rated input voltage. 1 G3TA Output Modules Isolation Phototriac Zero cross function Indicator Yes Yes Rated output load 2 A at 100 to 240 VAC at 60C No Rated input voltage 12 VDC Model G3TA-OA202SZ-US 24 VDC 12 VDC G3TA-OA202SL-US 24 VDC Photocoupler --- 2 A at 5 to 48 VDC at 60C 12 VDC G3TA-ODX02S-US 24 VDC 1 A at 48 to 200 VDC at 40C 12 VDC G3TA-OD201S-US 24 VDC Note: 1. For information on products that are certified for international standards, consult your OMRON sales representatives. (Models certified for UL and CSA standards have "-US" at the end of the model number.) 2. Input Modules are mainly suitable for signal input to PLCs. For load switching, consider using an Output Module. I/O Indication Mark attached to the top of product The modules are classified as Input Modules and Output Modules according to the main application of the Module. I/O module classification and AC/DC use are indicated on the mark affixed to the top of the product. Mark indication AC IN Specification Input module, AC input DC IN Input module, DC input AC OUT Output module, AC output DC OUT Output module, DC output Accessories (Order Separately) Connecting Socket I/O classification Input (NPN, - common) Rated voltage 12 VDC Model P7TF-IS16 24 VDC 100/110 VDC 100/110 VAC 200/220 VAC Output (NPN, + common) 12 VDC P7TF-OS16 24 VDC Output (PNP, - common) 12 VDC P7TF-OS16-1 24 VDC Output (NPN, + common) 12 VDC P7TF-OS08 24 VDC --- --- P7TF-05 2 G3TA Specifications Ratings (at an Ambient Temperature of 25C) Input Module Input Model Rated voltage Operating voltage Input current Voltage level Must operate voltage Must release voltage G3TA-IAZR02S-US 100 to 240 VAC 80 to 264 VAC 80 VAC max. 10 VAC min. G3TA-IDZR02S-US 5 to 24 VDC 4 to 32 VDC 5 mA max. 4 VDC max. 1 VDC min. G3TA-IDZR02SM-US 4 to 24 VDC 3 to 32 VDC 3 VDC max. Output Model G3TA-IAZR02S-US Logic level supply voltage 4 to 32 VDC Output breakdown voltage 32 VDC max. Output current 25 mA max. Output current (load current) 0.1 to 25 mA VCEO (reference value) 80 V G3TA-IDZR02S-US G3TA-IDZR02SM-US Output Module Input Model Rated voltage Operating voltage Input impedance Voltage level Must operate voltage Must release voltage G3TA-OA202SZ-US G3TA-OA202SL-US G3TA-ODX02S-US G3TA-OD201S-US 12 VDC 9.6 to 13.2 VDC 0.9 k20% 9.6 VDC max. 24 VDC 19.2 to 26.4 VDC 1.7 k20% 19.2 VDC max. 12 VDC 9.6 to 13.2 VDC 0.9 k20% 9.6 VDC max. 24 VDC 19.2 to 26.4 VDC 1.7 k20% 19.2 VDC max. 12 VDC 9.6 to 13.2 VDC 3.5 k20% 9.6 VDC max. 24 VDC 19.2 to 26.4 VDC 6.5 k20% 19.2 VDC max. 12 VDC 9.6 to 13.2 VDC 3.6 k20% 9.6 VDC max. 24 VDC 19.2 to 26.4 VDC 6.4 k20% 19.2 VDC max. 2 VDC min. Output Model Rated load voltage Load voltage range G3TA-OA202SZ-US 100 to 240 VAC 75 to 264 VAC G3TA-OA202SL-US 100 to 240 VAC 75 to 264 VAC G3TA-ODX02S-US 5 to 48 VDC G3TA-OD201S-US 48 to 200 VDC Load current (See note.) Inrush current VDRM, VCEO (reference value) 600 (VDRM) 0.05 to 2 A 30 A (60 Hz, 1 cycle) 4 to 60 VDC 0.01 to 2 A 12 A (10 ms) 80 (VCEO) 40 to 200 VDC 0.01 to 1 A 6 A (10 ms) 400 (VCEO) Note: The minimum current value is measured at 10C min. 3 G3TA Characteristics Input Module Item G3TA-IAZR02S-US G3TA-IDZR02S-US Operate time 20 ms max. Release time 20 ms max. 0.5 ms max. Output ON voltage drop 1.6 V max. 1.6 V max. G3TA-IDZR02SM-US 0.5 ms max. Leakage current 5 A max. Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 4,000 VAC, 50/60 Hz for 1 min between input and output Vibration resistance Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude Shock resistance Malfunction: 1,000 m/s2 Ambient temperature Operating: -30C to 80C (with no icing or condensation) Storage: -30C to 100C (with no icing or condensation) Ambient humidity Operating: 45% to 85% Certified standards UL508 file No. E64562/CSA C22.2 (No. 0, No. 14) file No. LR35535 Weight Approx. 16 g Output Module Item G3TA-OA202SZ-US Operate time 1/2 of load power source cycle + 1 ms max. Release time Output ON voltage drop Leakage current G3TA-OA202SL-US 1 ms max. G3TA-ODX02S-US 2 ms max. 1/2 of load power source cycle + 1 ms max. 2 ms max. 2 ms max. 1.6 V rms max. 1.6 V max. 2.5 V max. 5 mA max. (at 200 VAC) 1 mA max. Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 4,000 VAC, 50/60 Hz for 1 min between input and output Vibration resistance Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude Shock resistance Malfunction: 1,000 m/s2 Ambient temperature Operating: Storage: Ambient humidity Operating: 45% to 85% Certified standards UL508 file No. E64562, CSA C22.2 (No. 14) file No. LR3553 Weight Approx. 23 g -30C to 80C (with no icing or condensation) -30C to 100C (with no icing or condensation) With up to four G3TA SSRs mounted before G7T Relays, switching is possible at the rated load current for each Relay. G3TA G3TA-OD201S-US 0.5 ms max. G7T With G3TA SSRs mounted before every other G7T Relays, switching is possible at the rated load current for each Relay. G3TA G7T 4 G3TA Engineering Data Load Current vs. Ambient Temperature Characteristics G3TA-OD201S-US Load current (A) Load current (A) G3TA-OA202SZ/OA202SL/ODX02S-US Single-point mounting 16-point mounting Single-point mounting 16-point mounting Ambient temperature (C) Ambient temperature (C) One Cycle Surge Current: Non-repetitive Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.) Inrush current (A. Peak) G3TA-OD201S-US Inrush current (A. Peak) G3TA-ODX02S-US Inrush current (A. Peak) G3TA-OA202SZ/OA202SL-US Energized time (ms) Energized time (ms) Energized time (ms) Connections G3TA-OA DC G3TA-ODX02S Black yes output G3TA-OD201S G3TA-OD Load power supply Load power supply Load 3 1 AC input G3TA-IAZR02S Red yes DC input G3TA-IDZR02S Green yes Load - 5 + 1 4 + 3 - - 5 + 1 4 G3TAIDZR02SM No Drive circuit Amplification circuit 5 4 Zero cross circuit - Amplification circuit + 3 1 Amplification circuit 5 4 AC G3TA-OA202SZ Black yes output (with zero cross) G3TA-OA202SL (without zero cross) Rated current circuit - Circuit Operation indicator Rated current circuit + 3 Output Case color Rated current circuit G3TA-IDZR02S/IDZR02SM Output Model Rectifier circuit G3TA-IAZR02S Circuit Configurations Rated current circuit External Connections (Bottom View) Note: The load is possible to connect either + side or - side. 5 G3TA Dimensions Note: All units are in millimeters unless otherwise indicated. 33.5 max. 28.4 10 max. 31.7 39 max. 24 7.1 7.5 9 6 Connecting Sockets 182 For Input (NPN, - Common) P7TF-IS16 68 35.3+0.2 0 M3.5 85 34 26 8 10 21 32.5 6 G3TA For Output (NPN, + Common) P7TF-OS16 182 68 85 35.3+0.2 0 M3.5 8 10 For Output (PNP, + Common) P7TF-OS08 21 32.5 68 102 M3.5 85 8 10 P7TF-O5 35.3+0.2 0 21 32.5 19 max. Five, M3.5 x 8 Square washer faced screw 71.5 max. 59 max. Safety Precautions Refer to Safety Precautions for All Solid State Relays. Precautions for Correct Use Please observe the following precautions to prevent failure to operate, malfunction, or undesirable effect on product performance. Connection With the SSR for DC switching, the load can be connected to either positive or negative output terminal of the SSR. Protective Component Since the SSR does not incorporate an overvoltage absorption component, be sure to connect an overvoltage absorption component when using the SSR under an inductive load. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 7 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2011.4 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2011 All Right Reserved.