DATA SHEET ZENER DIODES RD2.0S to RD120S ZENER DIODES 200 mW 2 PINS SUPER MINI MOLD DESCRIPTION PACKAGE DIMENSIONS Type RD2.0S to RD120S Series are 2 PIN Super Mini (in millimeter) Mold Package zener diodes possessing an allowable power dissipation of 200 mW. PACKAGE DIMENSIONS * Sharp Breakdown characteristic. 0.30.05 1.250.1 (in millimeters) FEATURES 2.50.15 * Vz: Applied E24 standard. Circuit for Constant Voltage, Constant Current, Wave form Clipper, Surge absorber, etc. ,, ,,,, APPLICATIONS 0.11 +0.05 -0.01 00.05 0.90.1 Cathode Indication 0.19 1.70.1 ABSOLUTE MAXIMUM RATINGS (TA = 25 C) Power Dissipation P 200 mW Forward Current IF 100 mA Reverse Surge Power PRSM 85 W (at t=10 s/1 pulse) Show Fig. 12 Junction Temperature Tj 150 C Storage Temperature Tstg -55 to +150 C The information in this document is subject to change without notice. Before using this document, please confirm that this is the latest version. Not all devices/types available in every country. Please check with local NEC representative for availability and additional information. Document No. D11444EJ3V0DS00 (3rd edition) Date Published March 1999 N CP(K) Printed in Japan (c) 1995 RD2.0S to RD120S ELECTRICAL CHARACTERISTICS (TA = 25 2 C) Type Number Zener Voltage Vz (V)Note 1 Dynamic Impedance Zz ()Note 2 Reverse Current IR (A) MIN. MAX. Iz (mA) MAX. Iz (mA) MAX. VR (V) RD2.0S B 1.90 2.20 5 100 5 120 0.5 RD2.2S B 2.10 2.40 5 100 5 120 0.7 RD2.4S B 2.30 2.60 5 100 5 120 1.0 RD2.7S B 2.50 2.90 5 110 5 120 1.0 B1 2.50 2.75 B2 2.65 2.90 B 2.80 3.20 5 120 5 50 1.0 B1 2.80 3.05 B2 2.95 3.20 B 3.10 3.50 5 130 5 20 1.0 B1 3.10 3.35 B2 3.25 3.50 B 3.40 3.80 5 130 5 10 1.0 B1 3.40 3.65 B2 3.55 3.80 B 3.70 4.10 5 130 5 10 1.0 B1 3.70 3.97 B2 3.87 4.10 B 4.00 4.49 5 130 5 10 1.0 B1 4.00 4.22 B2 4.14 4.35 B3 4.27 4.49 B 4.40 4.92 5 130 5 10 1.0 B1 4.40 4.63 B2 4.53 4.77 B3 4.67 4.92 B 4.82 5.39 5 130 5 5 1.5 B1 4.82 5.06 B2 4.96 5.22 B3 5.12 5.39 B 5.29 5.94 5 80 5 5 2.5 B1 5.29 5.57 B2 5.47 5.75 B3 5.65 5.94 B 5.84 6.55 5 50 5 2 3.0 B1 5.84 6.14 B2 6.04 6.35 B3 6.24 6.55 RD3.0S RD3.3S RD3.6S RD3.9S RD4.3S RD4.7S RD5.1S RD5.6S RD6.2S 2 Class Data Sheet D11444EJ3V0DS00 RD2.0S to RD120S ELECTRICAL CHARACTERISTICS (TA = 25 2 C) Type Number Class Zener Voltage Vz (V)Note 1 Dynamic Impedance Zz ()Note 2 Reverse Current IR (A) MIN. MAX. Iz (mA) MAX. Iz (mA) MAX. VR (V) B 6.44 7.17 5 30 5 2 3.5 B1 6.44 6.76 B2 6.62 6.96 B3 6.83 7.17 B 7.03 7.87 5 30 5 2 4.0 B1 7.03 7.39 B2 7.25 7.63 B3 7.49 7.87 B 7.73 8.67 5 30 5 2 5.0 B1 7.73 8.13 B2 7.98 8.39 B3 8.25 8.67 B 8.53 9.58 5 30 5 2 6.0 B1 8.53 8.96 B2 8.81 9.26 B3 9.12 9.58 B 9.42 10.58 5 30 5 2 7.0 B1 9.42 9.90 B2 9.74 10.24 B3 10.08 10.58 B 10.40 11.60 5 30 5 2 8.0 B1 10.40 10.92 B2 10.72 11.26 B3 11.06 11.60 B 11.38 12.64 5 35 5 2 9.0 B1 11.38 11.94 B2 11.69 12.28 B3 12.04 12.64 RD13S B 12.43 14.00 5 35 5 2 10 RD15S B 13.80 15.56 5 40 5 2 11 RD16S B 15.31 17.14 5 40 5 2 12 RD18S B 16.89 19.08 5 45 5 2 13 RD20S B 18.80 21.14 5 50 5 2 15 RD22S B 20.81 23.25 5 55 5 2 17 RD24S B 22.86 25.66 5 60 5 2 19 RD27S B 25.10 28.90 2 70 2 2 21 RD30S B 28.00 32.00 2 80 2 2 23 RD33S B 31.00 35.00 2 80 2 2 25 RD36S B 34.00 38.00 2 90 2 2 27 RD6.8S RD7.5S RD8.2S RD9.1S RD10S RD11S RD12S Data Sheet D11444EJ3V0DS00 3 RD2.0S to RD120S ELECTRICAL CHARACTERISTICS (TA = 25 2 C) Type Number Class Zener Voltage Vz (V)Note 1 Dynamic Impedance Zz ()Note 2 MIN. MAX. Iz (mA) MAX. Iz (mA) MAX. VR (V) RD39S B 37.00 41.00 2 100 2 2 30 RD43S B 40.00 45.00 2 130 2 2 33 RD47S B 44.00 49.00 2 150 2 2 36 RD51S B 48.00 54.00 2 180 2 1 39 RD56S B 53.00 60.00 2 180 2 1 43 RD62S B 58.00 66.00 2 200 2 0.2 47 RD68S B 64.00 72.00 2 250 2 0.2 52 RD75S B 70.00 79.00 2 300 2 0.2 57 RD82S B 77.00 87.00 2 300 2 0.2 63 RD91S B 85.00 96.00 1 700 1 0.2 69 RD100S B 94.00 106.0 1 700 1 0.2 76 RD110S B 104.0 116.0 1 800 1 0.2 84 RD120S B 114.0 126.0 1 900 1 0.2 91 Note 1. Vz is tested with pulsed (40 ms). 2. Zz is measured at Iz by given a very small A.C. current signal. 4 Reverse Current IR (A) Data Sheet D11444EJ3V0DS00 RD2.0S to RD120S TYPICAL CHARACTERISTICS (TA = 25 C) Fig. 1 POWER DISSIPATION vs. AMBIENT TEMPERATURE P - Power Dissipation - mW 250 200 30x30x1.6 P. C. B. (Glass Epoxy) 150 100 50 0 0 25 50 75 100 125 150 TA - Ambient Temperature - C Fig. 2 ZENER CURRENT vs. ZENER VOLTAGE Fig. 3 ZENER CURRENT vs. ZENER VOLTAGE RD2.2S RD2.0S RD2.4S 100 m RD2.7S RD3.0S RD3.3S 10 m RD3.6S RD3.9S RD6.8S RD7.5S RD8.2S RD9.1S TA = 25 C TYP. 100 m RD13S 10 m 1m 1m IZ - Zener Current - A IZ - Zener Current - A RD10S RD11S RD12S 100 10 100 10 1 1 100 n 100 n RD4.3S RD4.7S RD5.1S RD5.6S 10 n 10 n RD6.2S 1n 0 1 2 3 4 5 6 7 VZ - Zener Voltage - V 8 9 10 1n Data Sheet D11444EJ3V0DS00 0 7 8 9 10 11 12 13 14 15 Vz - Zener Voltage - V 5 RD2.0S to RD120S Fig. 4 ZENER CURRENT vs. ZENER VOLTAGE Fig. 5 ZENER CURRENT vs. ZENER VOLTAGE TA = 25 C TYP TA = 25 C TYP 100 m 100 m RD15S RD22S RD18S RD20S RD16S 10 m 10 m 1m Iz - Zener Current - A 1m Iz - Zener Current - A RD27S RD30S RD24S 100 10 1 100 10 1 100 n 100 n 10 n 10 n 1n 1n 0 0 12 13 14 15 16 17 18 19 20 Vz - Zener Voltage - V Fig. 6 ZENER CURRENT vs. ZENER VOLTAGE 16 18 20 22 24 26 28 30 32 Vz - Zener Voltage - V Fig. 7 ZENER CURRENT vs. ZENER VOLTAGE TA = 25 C TYP TA = 25 C TYP 100 m 100 m RD68S RD62S RD82S RD91S RD47S RD75S RD100S 10 m RD110S RD43S RD120S RD56S RD33S RD36S 10 m RD39S 1m 100 10 1 100 10 1 100 n 100 n 10 n 10 n 1n 6 Iz - Zener Current - A Iz - Zener Current - A 1m 1n 0 25 30 35 Vz - Zener Voltage - V 40 Data Sheet D11444EJ3V0DS00 0 30 60 90 Vz - Zener Voltage - V 120 RD2.0S to RD120S Fig. 8 DYNAMIC IMPEDANCE vs. ZENER CURRENT ZZ - Zener Impedance - 1000 RD2.0S RD2.4S RD3.0S RD3.9S RD4.7S RD5.1S 100 RD5.6S RD39S RD24S RD20S RD15S RD10S 10 RD7.5S 1 0.1 1 10 100 IZ - Zener Current - mA Fig. 9 ZENER VOLTAGE TEMPERATURE Fig. 10 ZENER VOLTAGE TEMPERATURE 32 0.06 24 0.04 16 %mV/C 0.02 8 0 0 -0.02 -8 -0.04 -16 -0.06 RD2.0S to RD39S 0 4 8 12 16 20 24 28 VZ - Zener Voltage - V 32 36 -24 40 0.12 Z - Zener Voltage Temperature Coefficient - mV/ C %V/C 0.08 Z - Zener Voltage Temperature Coefficient - % / C 40 0.1 COEFFICIENT vs. ZENER VOLTAGE Z - VZ Temperature Coefficient - mV/C Z - VZ Temperature Coefficient - %/C COEFFICIENT vs. ZENER VOLTAGE 140 TYP. 120 0.11 %/C 0.10 100 80 0.09 mV/C 0.08 60 0.07 RD43S to RD120S 0 Data Sheet D11444EJ3V0DS00 40 50 60 70 80 90 100 110 120 Vz - Zener Voltage - V 40 20 7 RD2.0S to RD120S Fig. 11 TRANSIENT THERMAL IMPEDANCE CHARACTERISTICS Zth - Transient Thermal Impedance -C 5000 1000 RD[ ]S 100 P.C.B (Glass Epoxy) 10 (30mm x 30mm x 1.6mm) 5 1m 10m 100m 1 10 100 t - Time - s Fig. 12 SURGE REVERSE POWER RATINGS 1 000 PRSM PRSM - Surge Reverse Power - W TA = 25 C Repetitive tT 100 10 1 1 10 100 1m tT - Pulse Width - s 8 Data Sheet D11444EJ3V0DS00 10 m 100 m RD2.0S to RD120S [MEMO] Data Sheet D11444EJ3V0DS00 9 RD2.0S to RD120S [MEMO] 10 Data Sheet D11444EJ3V0DS00 RD2.0S to RD120S [MEMO] Data Sheet D11444EJ3V0DS00 11 RD2.0S to RD120S [MEMO] * The information in this document is subject to change without notice. Before using this document, please confirm that this is the latest version. * No part of this document may be copied or reproduced in any form or by any means without the prior written consent of NEC Corporation. NEC Corporation assumes no responsibility for any errors which may appear in this document. * NEC Corporation does not assume any liability for infringement of patents, copyrights or other intellectual property rights of third parties by or arising from use of a device described herein or any other liability arising from use of such device. No license, either express, implied or otherwise, is granted under any patents, copyrights or other intellectual property rights of NEC Corporation or others. * Descriptions of circuits, software, and other related information in this document are provided for illustrative purposes in semiconductor product operation and application examples. The incorporation of these circuits, software, and information in the design of the customer's equipment shall be done under the full responsibility of the customer. NEC Corporation assumes no responsibility for any losses incurred by the customer or third parties arising from the use of these circuits, software, and information. * While NEC Corporation has been making continuous effort to enhance the reliability of its semiconductor devices, the possibility of defects cannot be eliminated entirely. To minimize risks of damage or injury to persons or property arising from a defect in an NEC semiconductor device, customers must incorporate sufficient safety measures in its design, such as redundancy, fire-containment, and anti-failure features. * NEC devices are classified into the following three quality grades: "Standard", "Special", and "Specific". The Specific quality grade applies only to devices developed based on a customer designated "quality assurance program" for a specific application. The recommended applications of a device depend on its quality grade, as indicated below. Customers must check the quality grade of each device before using it in a particular application. Standard: Computers, office equipment, communications equipment, test and measurement equipment, audio and visual equipment, home electronic appliances, machine tools, personal electronic equipment and industrial robots Special: Transportation equipment (automobiles, trains, ships, etc.), traffic control systems, anti-disaster systems, anti-crime systems, safety equipment and medical equipment (not specifically designed for life support) Specific: Aircraft, aerospace equipment, submersible repeaters, nuclear reactor control systems, life support systems or medical equipment for life support, etc. The quality grade of NEC devices is "Standard" unless otherwise specified in NEC's Data Sheets or Data Books. If customers intend to use NEC devices for applications other than those specified for Standard quality grade, they should contact an NEC sales representative in advance. M7 98.8