TM Fuseholders for Indicating Fuses GMT Type Dimensional Data Printed Circuit Board Application Shown With GMT Fuse Installed Note: Similar Body Dimensions of All Holders Are Identical. 0.31" Approx. 0.84" 0.84" (7.7mm) (21.4mm) (21.4mm) 0.64" (16.3mm) 1.02" 0.64" (16.3mm) 0.13" 1.02" HLT (25.9mm) (25.9mm) (3.2mm) 0.15" (3.8mm) HLS 0.15" (3.8mm) HLS-F HLS-C 0.25" (6.4mm) 0.13" (3.2mm) (6.4mm) (10.3mm) 0.84" CATALOG SYMBOL: HLS, HLT, PCT FUSEHOLDERS FOR GMT TYPE INDICATING FUSES ELECTRICAL RATING-60V DC, 125V AC UL RECOGNIZED (GUIDE # IZLT2, FILE E14853) 15AMP (60V DC) Materials: Body: Terminals: HLT-F 0.08" (2.0mm) 0.41" 0.25" HLT-D (21.3mm) Wire Wrap Terminal 0.025" x 0.063" 0.64" (16.3mm) (0.64mm) (1.6mm) 0.45" (11.4mm) 0.11" Fuse Terminal Alarm Terminal PCT-A (2.8mm) PCT Thermosplastic, UL 94V0 flammability rating Tin-plated bifrucated copper For use with GMT Type Indicating Fuses 0.19" (4.8mm) (6.4mm) x "A" Spaces Tolerance to be non-accumulative 0.25" Panel Mounting Data 0.15"(3.8mm) Dia. 0.16"(3.9mm) Dia. .041" Multiple Fuseholders with bus bars Ordering Information-Catalog No. 0.86" (21.8mm) (10.4mm) 1.21" (30.8mm) 0.27" (6.7mm) 0.25" (6.4mm) .09" Dia. Holes (2.4mm) (3 Holes Per Poles of Fuseholder) Termination Location Body Style HLT HLS (No flanges) L (Left only) No. of Poles 01 thru 25 (Min. of 2 poles required for bus bars) Type of bus bars used B1*, B2, B3, B4, B5, SL** (Short Leads .135") ML** (Medium Leads .250") ** Not available with bus bars B1 (Angle Bar Only)* B2 ("L" Bar Only) B3 ("U" Bar Only) * Angle Bar mounts on common or center terminals only. Minimum of 4 Poles Required. **SL Version is not available with bus bars. Bus Bar Position P1 (Inside- Both Sides) P2 (Outside- Both Sides) B4 (Angle & "L" Bars) R (Right only) P3 (Outside- Right Only) B (Both ends) P4 (Outside- Left Only) B5 ("L" &"U" Bars) The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All other copies of this BIF document are by definition uncontrolled.This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. 0712 BU-SB12567 Page 1 of 1 Data Sheet 5010