New Frontiers in Safety, Security and Comfort. Explosion Protection & Harsh Environment http://www.patlite.com e-mail:overseas@patlite.co.jp 8-8, Matsuyamachi, Chuo-ku, Osaka, Japan 542-0067 International Division, Sales and Marketing Department TEL: +81-6-6763-8220 FAX: +81-6-6763-8221 E-mail:sales@patlite.com 20130 S. Western Ave. Torrance, CA90501, U.S.A. TEL: +1-310-328-3222 FAX: +1-310-328-2676 E-mail:sales@patlite.com.sg No.2 Leng Kee Road, #05-01 Thye Hong Centre, Singapore 159086 TEL: +65-6226-1111 FAX: +65-6324-1411 E-mail:sales@patlite.cn Room 512, Jufeng Business Building, No.697-3 Lingshi Road, Shanghai China 200072 TEL: +86-21-6630-8969 FAX: +86-21-6630-8938 E-mail:info@patlite.eu Am Soeldnermoos 8, D-85399 Hallbergmoos, Germany TEL.+49-0-811 9981 9770-0 FAX.+49-0-811 9981 9770-9 E-mail : sales@patlite.co.kr 202 Seokwang Bldg. 1361-9 Seocho-dong, Seocho-gu, Seoul, 137-863 TEL.+82-2-523-6636 FAX.+82-2-523-6637 LOT 321 Batamindo Industrial Park, Jalan Beringin Mukakuning, Batam 29433 Indonesia TEL: +62-770-61-1123 FAX: +62-770-61-2444 Sanda Plant Headquarters To ensure correct use of these products, read the Instruction Manual prior to use. Failure to follow all safeguards can result in fire, electric shock, or other accidents. Specifications are subject to change without notice. I SO 14001 I S O 9001 C ert if ied Headquarters Sanda Plant Techno Center PT. PATLITE INDONESIA PATLITE (U.S.A.) PATLITE Europe GmbH PATLITE (SINGAPORE) PATLITE KOREA For the benefit of mankind and the earth, PATLITE is committed to developing environmentally friendly products. Explosion-Proof Explosion-Safe Intrinsically-Safe Robust Heavy Duty 0120B 1108F(F)/JF(NP)B World-wide Sales, Marketing and After-sales Support Network. Factory Sales Subsidiary PATLITE Europe GmbH Munich, Germany PATLITE Europe GmbH PATLITE KOREA CO.,LTD. Seoul, Korea Sanda Plant PATLITE KOREA CO.,LTD. Sanda Plant Sanda, Japan PATLITE (U.S.A.) Corporation Los Angeles PATLITE (CHINA) Corporation PATLITE (CHINA) Corporation Shanghai PATLITE (U.S.A.) Corporation PATLITE (SINGAPORE) PTE LTD PT. PATLITE INDONESIA PT. PATLITE INDONESIA PATLITE (SINGAPORE) PTE LTD "New Frontiers in Safety, Security and Comfort" is PATLITEs mission. PATLITE offers state-of-the-art equipment for process and industrial automation for over 60 years. Our Innovative and robust design, backed by a powerful commitment and years of knowledge, has made PATLITE the world' s best known manufacturer of the visual and audible signaling products. We are also dedicated to the development of explosive and harsh-environment products to demonstrate our strong commitment to serving the industry with unique and innovative solutions. In order to identify the diversified needs of our customers, and respond quickly and satisfactorily to those needs, we have implemented the POP (Point of Production) System together with a lean-manufacturing cell-based assembly system (combination, single, and flexible assembly). These new systems allow us to handle any order rapidly from single items to customized item orders. Wide-range of Innovative and World-class Quality Products. We' ve also reduced development time and production cost by having our own in-house machinery to produce, design and manufacture metal moldings and plastic materials with the use of injection machinery. From designing to production, from raw material to the finished product, we also manage our quality control throughout the entire process. This is how we maintain our world class quality reputation in the visual, audible signaling and networking information products. From designing to production, quality control is managed throughout the process. Design with 3-D CAD 1 Manufacturing of metal molding parts Electrical discharge machine Machining Center Injection molding machines 2 Various Applications for Explosion-Proof, Explosion-Safe and Harsh Environments. How Explosion Occurs Prerequisites for an explosion Mixture of oxygen and explosive substance develop explosive gases. When the concentration of the substance in air is within the lower and upper explosive limits, the mixture can be ignited. To prevent an explosion, one of three prerequisites must be eliminated. To make equipment an ignition-free to install in explosive environment is one of the solutions. PATLITE offers Explosion Proof, Explosion-Safe, Intrinsically-Safe visual and audible signaling products as well as LED illumination work lights in order to increase safety in the work environment. Branch Explosive Material Oxygen Power Generation Companies Lump Coal Dust Woodworking Industry Saw Dust Fine Wood Chips Metal-work Operations Explosive Metal Dust Spark-ignitable Metal Dust Food/Beverage Industry Ignitable Grain Dust Explosive Sugar Dust Refinery Industry Hydorocarbons close to their flash-points Oil Processing Plants Waste Disposal Companies Waste-water Treatment Gasses Landfills/Civil Engineering Flammable Landfill Gases Uncontrolled Gas Emissions Flammable Gas from poor ventillation sources Pharmaceutical Industry Alcohol Solvents Materials explosive when mixed Gas Suppliers Natural Gas Leakage Natural Gas Emissions Paint-spraying Operations Overspray in Spray-paint Bays Solvent Vapor Emissions Recycling Operations Unemptied flammable gas/liquid containers Biodegradable Material Emitting Explosive Gasses Chemical Industry Flammable Gases Flammable Liquids Flammable Solids Agriculture Bio-gas Production Plants Bio-gas Located on Farms Explosion Source of Ignition An explosive environment is categorized in three segments, Zone 0, Zone 1 and Zone 2, depending on the hazardous level of gases and vapors. Zone 0 An area where an explosive atmosphere consisting of a mixture of air containing flammable substances in the form of gas, liquid, or vapor is continuously present and/or frequent. Zone 1 An area where an explosive atmosphere consisting of a mixture of air containing flammable substances in the form of gas, liquid or vapor is likely to occur under normal conditions on occasion. 3 Explosion Hazard Zone 2 An area where an explosive atmosphere consisting of a mixture of air containing flammable substances in the form of gas, liquid, or vapor is not likely to occur under normal conditions. However, if it occurs, it will only be for short periods of time. 4 Relationship of IEC, CENELEC, NEC 505 and NEC 500 Classification of Hazardous Areas IEC: International Electrotechnical Commission CENELEC: European Committee for Electrotechnical Standardization NEC: National Electrical Code Gases/Vapors A tank filled with flammable liquid: There is a potential risk of an explosion which may occur inside the tank. Therefore, the inside of the tank is categorized as Zone 0. Vapor may escape on occasion through the vent on the top of the tank, therefore the area around the vent is categorized as Zone 1. The vapor may also run down the outside of the tank, developing another explosive environment, so the area around the tank is categorized as Zone 2. IEC/CENELEC Zone 0 Zone 1 USA:NEC 505 Zone 0 Zone 1 Zone 2 Zone 2 Division 1 USA:NEC 500 Explosive Material Division 2 Class Group I A, B, C, D Gas, Vapor or Liquid Dust II E, F, G Fibers III Gas, Vapor or Liquid Explosive Material Class Group I A, B, C, D Dust II E, F, G Fibers III Gases/Vapors Standards Equipment Group Category Explosive Atmosphere: Gas or Dust 2 G Group IEC CENELEC ATEX Directive 94/9/EC NEC 505 Class 1, Zone 1 Zone 0, 1, 2 ATE X E C 6 0 0 7 9 -1 0 IE C IE C 6 0 0 7 9 -1 0 US N EC505 NEC 500 Constant Exposure Occasional Exposure Rare and Temporary Zone 0 (Category 1) Zone 1 (Category 2) Zone 2 (Category 3) Zone 0 Zone 1 Zone 2 Zone 0 (class ) Zone 1 (class ) Zone 2 (class ) de IIC T4 Ex de IIC T4 AEx de IIC T4 Types of Protection Gas Group Temperature Class (max. surface temperature) IP Protection Rate: Index of Ingress Protection IEC60529 IP 5 No detrimental effect occurs when a jet-stream is applied to the test sample from any direction. (TEST: 12.5 liter/min. of water is sprayed with a jet nozzle, having an internal diameter of 6.3mm, and a distance from the test sample of 2.5m - 3m away) 6 No detrimental effect occurs when water is sprayed onto the test sample by a jet-stream from any direction. (TEST: 100 liter/min. of water is sprayed with a jet nozzle, having an internal diameter of 12.5mm, with a distance of 2.5m - 4m away from the test sample) 7 Water must not enter into the device. No detrimental effect occurs when the device is submerged in a depth of 1 meter of water for 30 minutes. 8 Water must not enter into the device. No detrimental effect occurs when the device is continuously submerged. The test conditions are to be mutually agreed upon by the manufacturer and user. Dust At a mill with a feed hopper and filter: A product, which causes dust particles mixed with sufficient air to cause an inflammable mixture, is loaded into a hopper. Inside the feed hopper and filter, it is categorized as Zone 20. While the product is being loaded, the mixture of dust and air Ex causes a potentially explosive compound in the area where the product is loaded into the hopper, so the area outside the hopper is categorized as Zone 21. Around the hopper where a potential inflammable atmosphere exists temporarily is categorized as Zone 22. 5 6 IP69K The entrance of dust is not closed completely. But dust may not go into the device in such manner as the optimal operation of the device and the safety are impaired. No intrusion of dust into the device IP69K is the German DIN 40050 PART9 standard. It is defined as a protection regulation for high temperature and high-pressurized water. Water is heated up to 80 C and sprayed at a water pressure in the range from 80 to 100 bars at 14 to 16 liters per minute at the test object. The test object is at a distance of 100 to150 mm from the nozzle and sprayed in all directions at 0, 30, 60, and 90 degrees, then sprayed at a horizontal angle while it is being rotated, all done for a period of 30 seconds without being affected by water penetration. 90 60 10-15cm 30 0 Constant Exposure Occasional Exposure Rare and Temporary E C 6 1 2 4 1 -1 0 Zone 20 (Category 1) Zone 21 (Category 2) Zone 22 (Category 3) IE C IE C 6 1 2 4 1 -1 0 Zone 20 Zone 21 Zone 22 US N EC505 ATE X N EC500 5 IP69K Test Procedure Note: Model CLA LED light bars comply with IP69K. See page 16 for more details. 6 Zone 1 Zone 2 Explosion-proof Maintenance Free LED Signal Lights The EDLM and EDWM series LED signal lights are visual warning and status indicating lights for use in hazardous locations that requires compliance with the ATEX Directive 94/9/EC (CENELEC standard) or NEC Article 505 certification. Explosion-Safe Visual/Audible Signaling Products & LED Light Bars A wide range of visual and audible signaling products, as well as super bright LED light bars, designed for use in hazardous locations that require the ATEX Directive 94/9/EC (CENELEC Standard). These unique and innovative models meet the The EDLM and EDWM series offers wide range of voltages and versatile mounting options to meet various applications. The following chart explains the comparison between the ATEX Directive 94/9/EC (CENELEC standard) and NEC Article 505 certification. To find the most suitable models, refer to page 9 and 10. criteria for Zone 2 (gas) and Zone 22 (dust) atmospheres. The CLA series LED light bars meets the criteria for intrinsically safe applications. CLA Series EWH24E/EXN CLF2024/EXN Protection Method (ATEX/IEC) EDLM Flame-proof Enclosure Type "d" Protection Type "tD" In flame-proof enclosures, an explosion is contained. Dust-protected and flame-proof enclosure. AR-070 Series AR-078 Series EDWM LKEHFE/EXN LKEHFV/EXN PVW04JF/EXN CLT3024/EXN LED Signal Towers Standard Markings Markings for North America (NEC Standards) Marking for ATEX Directive (CENELEC Standard) 2 G CE 0000 CE Marking Notified Body Number ATEX Directive Marking NEC505 (Zone System) American National Standard Explosion Protection Temperature Code Gas Group Class I, Division1, Groups A,B,C,D, T6 Temperature Class Dust Protection Codes (only type of Ex tD) Dust Area Classification (only type of Ex tD) Flammable Gas or Vapor Explosion-proof Protection IEC IECEx Protection NEC505 Zone 1, 2 EN60079-1 IEC60079-1 AEx d 1, 2 Ex e 1, 2 EN60079-7 IEC60079-7 AEx e 1, 2 Ex ia 0, 1, 2 EN60079-11 IEC60079-11 AEx ia 0, 1, 2 Ex ib 1, 2 EN60079-11 IEC60079-11 AEx ib 1, 2 Purged/Pressurized Ex p 1, 2 EN60079-2 IEC60079-2 AEx p 1, 2 Encapsulation Ex m 1, 2 EN60079-18 IEC60079-18 AEx e 1, 2 Increased Safety Intrinsic Safety (2 faults) Intrinsic Safety (1 fault) Non-incendiaries Type-n Ex n 2 EN60079-15 IEC60079-15 AEx n 2 NEC500 US Division US FM3615 ANSI/ISA 1, 2 UL1203 60079-1 ANSI/ISA 60079-7 ANSI/ISA FM3610 1, 2 60079-11 UL913 ANSI/ISA 60079-11 ANSI/ISA FM3620 1, 2 60079-2 NFPA496 ANSI/ISA 60079-18 FM3611 2 UL1604 ANSI/ISA 60079-15 ATEX Directive (CENELEC) Equipment Group CategoryProtection Level M1- Very High Level M2- High Level -other areas 2- High Level Explosive Environment Flammable Substances Constant Exposure Methane T1 Hazardous Areas 3- Normal Level 7 Ocassional Exposure Coal Dust Constant Exposure Gases Zone 0 (Gases) Zone 20 (Dust) Vapors Zone 1 (Gases) Zone 21 (Dust) Ocassional Exposure Rare and Temporary Temperature Code Mists Dust Zone 2 (Gases) Zone 22 (Dust) Page Model Selection PVW04JF/EXN EWH24E/EXN Page 14 15 CENELEC Standard EN60079-0, EN60079-15 EN60079-0 , EN60079-15 Model Selection CLT3024S-CD CLF2024/EXN CLA series Page 16 16 16 CENELEC Standard EN60079-0, EN60079-15 EN60079-0 , EN60079-15 EN60079-15 MP3 Field Progmmable Annunciator integrated with LED tower CENELEC Standard EN60079-0, EN60079-15 EN60079-0 , EN60079-15 13 13 Class Zone 0 An area where the mixture of explosive gas is continuously present or present for long periods. Zone 1 Class Zone 1 An area where the mixture of explosive gas can be present during normal operation. Zone 2 Class Zone 2 An area where the mixture of explosive gas is not normally present, but if it occurs, it will only be for brief periods of time. Gases Dust Zone 20 An area where the mixture of incendiary dust is continuously present or present for long periods. Zone 21 An area where the mixture of incendiary dust can be present during normal operation. Zone 22 An area where the mixture of incendiary dust is not normally present, but if it occurs, it will only be for brief periods of time. T2 T3 Methane Ethyl Alcohol Gasoline A Acetone ethane Propane Cyclohexane Aircraft fuel n-butane Diesel fuel Lighting gas Ethylene Ethylene glyco B C Acrylonitrile Ethylene oxide Hydrogen Acetylene T4 Gas Zone2 Zone2 Dust Zone22 Zone22 Hazardous Area CE CE Explosion Safety II !" II !" Gas Zone2 Zone2 CE CE Explosion Safety II !" II !" Gas Zone2 Zone2 CE CE CE Explosion Safety II II II # Gas Zone2 Zone2 Zone2 Dust Zone22 Zone22 Hazardous Area Dust Zone22 Zone22 Hazardous Area Dust Zone22 Zone22 Zone22 * These products are manufactured by PATLITE, converted to Ex Certification by Artidor, and sold by Patlite. 0123 Hazardous Area Classification Zone 0 Vapors Explosion Safety II !" II !" Markings ATEX/IEC Classification for Gases & Temperature Coding -mines 1- Very High Level CENELEC NEC505 IEC North America Class CENELEC ATEX Ex d Flameproof Gas Group Area Classification Zone Classification Europe (ATEX Directive / (CENELEC) International (IEC) Protection Method Protection Zone Code Model Selection LKEHFV/EXN LKEHFE/EXN Hazardous Area CE CE Super Bright LED Light Bars NEC500 (Division System) Ex tD A21 IP66 T80 Protection Method CENELEC Standard EN60079-0, EN60079-15 EN60079-0 , EN60079-15 Voice Annunciator, Melodies & Chimes Horns Temperature Code Gas Group Protection Method Flammable Gas or Vapor Area Classification Ex d C T6 Explosion Protection Page 11 12 Class I, Zone1, A Ex d C T6 Type of Explosive Environment Category Equipment Group Explosion-Protected Type of Protection Model Selection AR-070 Series AR-078 Series T5 T6 II 2 Ex d IIC T6 G Type of Ex Atmosphere G ....... Gas D ....... Dust Equipment-Category M1 ..... very high safety level (Mines) M2 ..... high safety level (Mines) 1 ........ very high safety level 2 ........ high safety level 3 ........ normal safety level Equipment-Group I ......... For mining installations II ........ For industrial installations Specific mark for explosion protection Registration number of Notified Body certified the QA system (if applicable). Quality mark for compliance with the EU directives, as a product passport to the European Market (not for components). Acetaldehyde Ethyl-ether Hydrogen sulphide Carbon Bisulfide Coal disulphide Temperature Class Maximum Surface Temperature) T1 ..... 450 T2 ..... 300 T3 ..... 200 T4 ..... 135 T5 ..... 100 T6 ..... 85 Gas Group I ........ Methane(fire damp) II ....... All gasses IIA ..... Propane & equivalent IIB ..... Ethylene & equivalent IIC ..... Hydrogen & Acetylene III ...... Fiber Flying Protection degree against ignition d ....... Flameproof Enclosure e ....... Increased Safety ia/ib/ic .......... Intrinsic Safe ma/mb/mc.... Moulded Encapsulation nA ..... Non-sparking nC ..... Separated nL ..... Energy Limited nR ..... Restricted Breathing o ....... Oil Immersion px/py/pz ....... Pressurising q ....... Powder Filling Explosion Safe 8 Zone 1 EDLM SERIES & EDWM SERIES EXPLOSION-PROOF Testing Authority PTB, Dimensions (EDLM*EDWM) Descriptions 283 347 (31) LED Modules (415) Lower Enclosure 347 126 3/4 NPT Zone 2 14 ] (Horizonal-mount) 9 15 Plug 9 Zone 1 11 50 Zone 0 ] 38 9 EDLM, EDWM ] 56 11 Present Abnormally (140) 0 (86) 9 92 O-ring 15 218 Earth Terminal M4 Screw ] Standard Present Intermittently Flush-mount Bracket (48) 56 ] Classification Present Continuously *ATEX Model ... Standardized Part *NEC Model ...... Non-Standardized Part Gland Port 1 3/4 NPT Gland Port 2 ATEX directive is CENELEC standard. PATLITE Models Glass Enclosure ] 120 EDLM & EDWM meet the specifications shown in the shaded areas below CENELEC Standards for Europe (24) 3/4 NPT 56 Vertical Mount Cable Gland* installation (Wall-mount) Upper Enclosure 12 Housing: Aluminum alloy Glass: Borosilicate glass Terminals: Easy wire connection to the Signal Tower by opening the bottom Mounting: Upright, Wall Mount, Vertical-mount, and Horizontal Mount LED color: Different color configurations are possible to custom-design Voltage: 24VAC/DC, 120VAC, 230VAC, 90-250VAC are available. Wire core size: 0.5mm2~0.8mm2, AWG20~AWG18 Fitting Bracket 152 ] 4.4 48 EDWM 90 5 EDLM 38 335 Features Horizontal Mount 12 The EDLM (colored 3 tiered LED) and EDWM (colored 5 tiered LED) are innovative LED maintenance free Signal Towers. The robust design with pressure and flame-proof housing is ideal for use in potentially flammable and hazardous explosive atmospheres such as chemical, petrochemical, combustible dust, production of mineral/natural gas, and even in the manufacturing of polysilicon for the photovoltaic, semi-conductor industries, as well as the food and beverage industries. Wall Mount NEC Article 505 Testing Authority 50 4 IEC 60079-10 EN 60079-10 56 Cover ATEX, IEC/EU Directive 94/9/EC 56 Terminal Block (Unit: mm) 218 NEC Standards for the USA Set Screw NEC standard is National Electrical Code. Classification Standard PATLITE Models Present Continuously Present Intermittently NEC Article 505 ANSI/NFPA 71 EDLM, EDWM Zone 0 Zone 1 NEC Article 500 ANSI/NFPA 70 Division 1 Present Abnormally Zone 2 Division 2 Wiring Diagram Wiring Diagram EDLM (3 color LED) EDWM (5 color LED) CENELEC (ATEX Directive) Luminosity Mass (Main Body) Material 9 L R L Y L G L B L W F C V 1 Yellow Gray Brown Orange Continuous Lighting External Contacts White Power Source Blue External Protection Fuse V 2 Green V 1 Orange F C Red L G External Protection Fuse V 2 Power Source Continuous Lighting External Contacts Flashing External Contacts Power Wire Power Wire Flashing COM Flashing External Contacts LED White LED Blue LED Green LED Amber LED Red EDWM-5M2FE/FA EDLM-312FE/FA EDLM-323FE/FA Upper & Lower case Aluminum Alloy (Housing Finish: Melamine-baked Finish) Glass case Borosilicate Glass Fitting Bracket Stainless,Steel (sus 316) Black Gray Brown Yellow External Protection Fuse Power Source Blue L L L C F V V R Y G C C 1 2 Green
Class , Zone 1 AEx d " $% = ?Y+[\ 45%85%RH (Keep from dew or condensation) 80110kpa Flashing (6012 flashes per minute) / Continuous Lighting IP66 9.8m/s 2 Outdoor & IndoorUpright & Sideways Outdoor & IndoorUpright Red: 350mcd, Amber: 580mcd Red/Green/White: 1000mcd Green: 1300mcd Amber: 700mcd, Blue: 300mcd 4.3kg 4.7kg
White EDWM-502FA EDWM-5M2FA AC/DC 24V AC 90250V Red: 22.6mA, Amber: 26.6mA, Green: 17.5mA Blue/White: 38.9mA Orange EDLM-323FA AC 230V Red EDLM-312FA AC 120V Red/Amber: 52.5mA Green: 20.0mA Green / Yellow NEC Article 505 EDLM-302FA AC/DC 24V L Y Power Wire Power Wire Flashing COM LED Green LED Amber LED Red Upper & Lower Case Aluminum Alloy (Housing Finish: Melamine-baked Finish) Glass Case Borosilicate Glass Fitting Bracket Stainless Steel (SUS 316) Cable Gland Brass Material OperatingTemperature Operating Humidity Ambient Pressure Lighting Pattern Protection Rating Vibration Resistance Mounting L R Red Orange Green Yellow Brown Gray Black Mass (Main Body) Explosion Protection Ratings Red $% '+ 45%85%RH (Keep from dew condensation) 80110kpa Flashing (6012 flashes per minute) / Continuous Light IP66 9.8m/s 2 Outdoor & Indoor Upright & Sideways Outdoor & Indoor Upright Red/Green/White: 1000mcd Red: 350mcd, Amber: 580mcd Amber: 700mcd, Blue: 300mcd Green: 1300mcd 4.3kg 4.7kg Luminosity
d C T6 (Zone 1 , 2 ) !"" (Zo n e 2 1 , 2 2 ) Explosion Protection Ratings OperatingTemperature Operating Humidity Ambient Pressure Lighting Pattern Protection Rating Vibration Resistance Mounting Model Voltage Rating Signal line Current (Per LED Module) EDWM-502FE/FA EDLM-302FE/FA Gray EDWM-502FE EDWM-5M2FE AC/DC 24V AC 90250V Red: 22.6mA, Amber: 26.6mA, Green: 17.5mA Blue/White: 38.9mA Brown EDLM-323FE AC 230V Yellow EDLM-312FE AC 120V Red/Amber: 52.5mA Green: 20.0mA Green EDLM-302FE AC/DC 24V Green / Yellow Model Voltage Rating Signal line Current (Per LED Module) L L L L L C F V V R Y G B W C C 1 2 Earth Ground Power Wire Power Wire Flashing COM Continuous COM LED Green LED Amber LED Red Continuous Lighting External Contacts Flashing External Contacts Earth Ground Power Wire Power Wire Flashing COM Continuous COM LED White LED Blue LED Green LED Amber LED Red External Protection Fuse Power Source Continuous Lighting External Contacts Flashing External Contacts 10 Zone 2 Zone 2 AR-070 SERIES AR-078 SERIES EXPLOSION-SAFE II 3 GD; Ex nA II T4; Ex tD A22 IP65 T85C 94/9/EC (ATEX) and 2004/108/EC (EMC) EN60079-0, EN60079-15, EN61241-0, EN61241-1 EXPLOSION-SAFE II 3 GD; Ex nA II T4; Ex tD A22 IP65 T85C 94/9/EC (ATEX) and 2004/108/EC (EMC) EN60079-0, EN60079-15, EN61241-0, EN61241-1 Explosion-safe Signal Light O40mm Explosion-safe Signal Light O60mm Description Description Explosion-safe Signal Light featuring an LED light that is versatile and energy-efficient. The vertical and horizontal cut lenses in combination with a double-reflection system enhances the LED light diffusion to create a unique, full and brilliant light. The lenses and main body are made of strong synthetic materials with characteristics to withstand harsh environments. The Signal Light can be ordered in any combination from 1 to 5 LED units with any color combination. In addition to its "continuous lighting" condition, the Signal Light can also be ordered with flashing / non-flashing functions, as well as with two super-loud alarm sounds with an 85dB (at 1m) output. Explosion-safe Signal Light featuring an LED light that is versatile and energy-efficient. The vertical and horizontal cut lenses in combination with a double-reflection system enhances the LED light diffusion to create a unique, full and brilliant light. The lenses and main body are made of strong synthetic materials with characteristics to withstand harsh environments. The Signal Light can be ordered in any combination from 1 to 5 LED units with any color combination. In addition to its "continuous lighting" condition, the Signal Light can also be ordered with flashing / non-flashing functions, as well as with two super-loud alarm sounds with an 90dB (at 1m) output. Features Features Specifications Dimensions II 3 GD; Ex nA II T4; Ex tD A22 IP65 T85C EN 60079-0, EN 60079-15, EN 61241-0, EN 61241-1 Certification: Ambient Temperature: Ingress Protection: Material: Lighting Source: Acoustical Source: Rated Voltage: Assembly position: Activation Time: EC-Declaration of conformity -30 C to +60 C IP65 to EN 60529 ABS towerbody, polyester glassfibre reinforced base Multiple LEDs with double reflection system Buzzer 85 dB (1m) with two different tones 24 V AC/DC As desired 100% SIGNAL LIGHT 60 Module Colors Available: Red, Amber, Green, Blue, Clear/white Cable: Factory sealed cable, O 8 mm, length 3 meter 14 From 1 to 5 tiers 3/4" NPT bracket for pole mount is available as an option. Available with "flashing/non flashing" and two audible buzzer alarm sounds Ingress protection of IP65 Wall mount or direct mount Explosion-safety: CE conformities: EN 60079-0, EN 60079-15, EN 61241-0, EN 61241-1 Certification: EC-Declaration of conformity Ambient Temperature: Ingress Protection: Material: Lighting Source: Acoustical Source: Rated Voltage: Assembly position: Activation Time: -30 C to +60 C IP65 to EN 60529 ABS towerbody, polyester glassfibre reinforced base Multiple LEDs with double reflection system Buzzer 90 dB (1m) with two different tones 24 V AC/DC As desired 100% Module Colors Available: Red, Amber, Green, Blue, Clear/white Factory sealed cable, O 8 mm, length 3 meter CURRENT RATINGS LED 60 Line Current Inrush 70 approx. 250 mA 8 23 approx. 40 mA Signal Red, Amber approx. 30 mA Current 40 Signal II 3 GD; Ex nA II T4; Ex tD A22 IP65 T85C Cable: BUZZER Line Current Green, Blue, Clear approx. 25 mA AR-078 series Specifications M4 CURRENT RATINGS LED Signal Red, Amber approx. 30 mA 12 Explosion-safety: CE conformities: 41 SIGNAL LIGHT AR-070 series 124 Dimensions Explosion-safe for gas and dust Suitable for Zone 2 and Zone 22 CE compliance in accordance to ATEX Full and brilliant lumination LED double reflection lighting system Different lens colors available From 1 to 5 tiers Available with "flashing/non flashing" and two audible buzzer alarm sounds Ingress protection of IP65 Wall mount or direct mount CONNECTION DIAGRAMS BUZZER Line Current Green, Blue, Clear approx. 25 mA Signal Line Current Inrush approx. 40 mA Current approx. 250 mA 31 Explosion-safe for gas and dust Suitable for Zone 2 and Zone 22 CE compliance in accordance to ATEX Full and brilliant lumination LED double reflection lighting system Different lens colors available CONNECTION DIAGRAMS 42 4.5 12 0 15 20 R=20 3/4" NPTbracket (Option) 60 120 4.5 EXPLOSION-SAFE SIGNAL LIGHT Continuous lighting (only) 1 Continuous/Flashing lighting and two Audible alarms 2 24V AC/DC Code No. of Stacks 1 1-5 EXPLOSION-SAFE SIGNAL LIGHT Code 1 2 3 4 5 Colors* Red Amber Green Blue Clear/White Units: mm How to order Code Continuous lighting (only) 1 Voltage Code No. of Stacks Continuous/Flashing lighting and two Audible alarms 2 24V AC/DC 1 1-5 35 Code 1 2 3 4 5 Colors* Red Amber Green Blue Clear/White Code R Y G B C Units: mm Type number AR-070 0 11 Code R Y G B C 25 Voltage 7 Code 25 How to order 1 / - RYGBC *Colors are arranged from top to bottom Type number AR-078 0 1 / - RYGBC *Colors are arranged from top to bottom 12 Zone 2 Zone 2 LKEHFE/EXN, LKEHFV/EXN PVW04JF/EXN EXPLOSION-SAFE II 3 GD; Ex nA II T4; Ex tD A22 IP65 T85C 94/9/EC (ATEX) and 2004/108/EC (EMC) EN60079-15, EN60079-0, EN61241-1, EN61241-0 105dB(A) MP3 Field Programmable Announciator, Melody Horn Explosion-safe for gas and dust Suitable for Zone 2 and Zone 22 CE compliance in accordance to ATEX Super bright LED colors correspond to different voice, sounds, chimes and melodies. Voice alert messages of up to 63 seconds (64kbit/s) with 5 channels can be played back. 32 combinations of sounds, chimes and melodies are pre-recorded. 8 sounds can be played back by a bit input, and 32 sounds by binary input. Volume is adjustable from 0 to 105dB at 1 meter. Field programmable with MP3 by SD card for the model LKEHFV/EXN. Well visible with the super bright 100mm diameter LED from far distance. Robust design to withstand against 2G vibration. The body is made of Acrylonitrite-Ethlene-Styrene for weather resistant. Easy to control by only one common wire for both LED units and audible signals. NPN is standard. PNP open colletor type is also available on order. Protection rating of IP65 Ultra bright LED 105dB horn PVW04JF/EXN LKEHFV/EXN, LKEHFE/EXN Dimensions Sound Selection Charts 60 5 0 o7 12 0 16.2 Stutter + Bell Inverted Revelle Annie Laurie Stutter Synthesized Melody Galactic Motor London Bridge Bell Chime Ringing Phone Marys Lamb Yelp Call Sign Two Tone Camptown Races Rapid Hi Lo Train Ride Alarm Clock Amaryllis Galloping Hi Lo Ringing Hi Lo Symphony #40 Synthesized Piano Alien Chatter Fur Elise Ave Maria Synthesized Bell Falling Crystals Minuet Grandfather's Clock 38 14.2W LKEHFE-W/EXN 3 14.2W LKEHFV-F/EXN Supports 3 14.2W LKEHFV-W/EXN Supports 3 14.2W LED units can be stacked to 1, 2, and 4 on order. SD card for the model LKEHFV-F/EXN and LKEHFV-W/EXN sold separately. R7 (4x) 60 200 151 Yellow Is 3 Pink COM Brown Source Voltage Rated Voltage 12V 24V BUSY OUT Orange GND 3- o9 ) Red COM Brown DC 24V Open Circuit: Vs=20V Closed Circuit: Is=5mA Blue Fuse Capacity 1A 0.5A An input of 100ms or more is required to activate the message. External Amplifier From wire exit 400 25 25 Flush mount bracket for LKEHFE-F/EXN & LKEHFV-F/EXN Wall mount bracket for LKEHFE-W/EXN & LKEHFV-W/EXN Channel Priority (mm) STOP (Red) >CH4 (Light green) >CH3 (Pink) >CH2 (Yellow) >CH1 (Skyblue) Note: The greater number has priority when any of the channels are activated simultaneously. Specifications 20 100 100 Power 3 ( 2 110 142 142 142 LED stack Skyblue Shielded wire AUX OUT Green 58 125 MP3 Voice: CH1~CH4*STOP Black 1 STOP - R10 (2x) (mm) Model White 4 Light green 500mA + 100 2-o10 LKEHFE-F/EXN Fuse Power supply 25 6 Front Beep Melody Chime 77 3-o 152 142 186 143 120 230 Mounting Dimension 0 12 Wiring Diagram 32 sounds are pre-recorded in one unit. 4 sound types are available. 8 sounds can be played back by a bit input, and 32 sounds by binary input. 105 Shaft Height 1 Light: 265.2 2 Lights: 325.3 3 Lights: 385.4 4 Lights: 445.5 Height Explosion-safe for gas and dust Suitable for Zone 2 and Zone 22 CE compliance in accordance to ATEX 4 pre-recordable messages on EPROM Maximum 63 seconds for recording time. Adjustable audible sound volume up to 105dB at 1 meter ADPCM 64kbit/s clear sound quality from an LSI digital voice synthesizer. Indoor Installation: upright, inverted, and sideways. Outdoor: upright installation only. Provided with an anti-corrosive stainless steel mounting bracket. 12/24VDC & 12/24VAC Protection rating of IP65 Insert SD card into the slot. 122 o100 105dB (at 1m) Voice Annunciator ADPCM 64kbit/s 166 Dimensions EXPLOSION-SAFE II 3 GD; Ex nA II T4; Ex tD A22 IP65 T85C 94/9/EC (ATEX) and 2004/108/EC (EMC) EN60079-15, EN60079-0, EN61241-1, EN61241-0 Model Rated Voltage PVW04JF /EXN 12/24V AC/DC Power Outer Contact Operating Voltage Range Consumption Volume Capacity Temperature Range 8~28V AC 9~35V DC 12W Max. 105dB at 1m More than 10mA -10C~+55C Humidity 85% or less. Auxiliary Input Non-voltage Contact 4/1bit Channel AUX Output BUSY Output 4 -10dBv 600 Max. load 24V DC 500mA Max Message Protection Mass Time 63 sec. IP65 1.3kg Specifications Model Rated Voltage MP3, Melody LKEHFE-F/EXN Type-E LKEHFE-W/EXN Type-E 24VDC 13 Voltage Range 24VDC +/-10% LKEHFV-F/EXN MPEG1-Audio layer III, 64kbit/s LKEHFV-W/EXN MPEG1-Audio layer III, 64kbit/s Operating Temperature Recordable Duration Sound Pressure (at 1m) Messages Mass 8ch bit input, Flush mount 32ch binary input 2.8Kg Prerecorded -10C to +50C, Humidity 85% or less Mounting Brackets Prerecorded Wall mount 105dB 8ch bit input, 3.2Kg 32ch binary input 63 sec. 5ch bit input, Flush mount 31ch binary input 2.8Kg 63 sec. Wall mount 5ch bit input, 3.2Kg 31ch binary input 14 Zone 2 Zone 2 EWH24E/EXN CLT3024S/EXN EXPLOSION-SAFE II 3 GD; Ex nA II T4; Ex tD A22 IP65 T85C 94/9/EC CENELEC: EN60079-15, EN60079-0, EN61241-1, EN61241-0 EXPLOSION-SAFE II 3 GD; Ex nA II T4; Ex tD A22 T135C 94/9/EC CENELEC: EN60079-15, EN60079-0, EN61241-1, EN61241-0 105dB (at 1m) Melodies & Chimes Horn White 6 Orange 7 Green 8 Blue Fuse Capacity Model Rated Voltage Fuse 1A EWH24E/ 12-24V (Slow-blow) EXN Black 2 wire cord 25 25 Sound selection made by dipswitch 125 Nominal sectional area : Cord type 0.75mm2 : VCT Test Switch 220mm long 1,700 lx LED color: white 6800K IP67 rated 42.5 -30C +60C Polycarbonate lens Aluminum housing CLF2024C/EXN Dimensions Specifications Nominal sectional area : Cord type Power supply wire : 0.75mm2 : VCTF Signal wire : 0.3mm2 : VCTF White 25 80 Explosion-safe for gas and dust Suitable for Zone 2 and Zone 22 CE compliance in accordance to ATEX 11 wire cord 220 Model CLF2024C/EXN LED Color C Rated Voltage 24V DC (No polarity) Operating Voltage Range Rated voltage 10% Power Consumption 5W Light Source High intensity LEDx8 Luminous Intensity at Optical Center (lx at 50cm) 1,700 Main Body Housing: Aluminum Cover: Polycarbonate Operating Temperature Range -30C ~ +60C (No condensation 90% RH or less) Indoor, Forward Direction Installation Protection Rating IP67 Vibration Resistance 19.6m/s2 Mass 205g10g 208 230 Approx. 420 Approx. 150 11 5 120 4* M 25.5 Red ! Light green 5 Approx. 400mm from wire exit Signal wires EXPLOSION-SAFE 50 Pink 4 (Unit: mm) 35 Yellow 3 Fuse 58 340 (8) 38 5 400 from wire exit 27 30 Skyblue 2 105 Power supply wire 4.5 Brown 1 Signal wires for External Contact channel selection Open circuit 20V Closed circuit 5mA 166 122 100 22 (15.5) (10.5) 186 143 120 350 II 3 GD; Ex nA II T4; Ex tD A22 T135C 94/9/EC CENELEC: EN60079-15, EN60079-0, EN61241-1, EN61241-0 Black COM 230 Dimensions CLF2024C/EXN Wiring Diagram Fuse CLT3024S/EXN Model CLT3024S/EXN LED Color Day light Color Rated Voltage 24V DC Operating Voltage Range Rated Voltage 10% Current Consumption 416mA 40mA Light Source High intensity LED x 16 elements Luminous Intensity at 500 Optical Center (lx at 50cm) Housing: Aluminum, Cover: Tempered glass Main Body Operating Temperature Range Any Direction (for indoor use only) Mounting Direction IP66G/IP67G JIS C 0920: 2003/Aqueous oil resistant (Company Standards) Protection Rating 19.6m/s2 Vibration Resistance 700g Mass (Unit: mm) Cover DIP switch, volume and test switch are located under the cover. IP67F rated -30C +60C Tempered glass lens Aluminum housing Specifications EWH24E/EXN Dimensions 350mm long 500 lx 24VDC, 416mA LED color: white 6750 K 50 Explosion-safe for gas and dust Suitable for Zone 2 and Zone 22 CE compliance in accordance to ATEX Explosion-safe for gas and dust Suitable for Zone 2 and Zone 22 CE compliance in accordance to ATEX 32 combinations of melodies, chimes and sounds are pre-recorded. Adjustable audible sound volume up to 105dB at 1 meter Indoor Installation: upright, inverted, and sideways. Outdoor: upright installation only. Provided with the anti-corrosive stainless steel mounting bracket. NPN is standard for the EWH type. PNP open collector is available on order. CE compliant : 24VAC/DC only IP65 Name plate " $; 7 (Green) > 6 (Orange) > 5 (Red) > 4 (Lightgreen) > 3 (Pink) > 2 (Yellow) > 1 (Skyblue) The greater number has priority when any of the channels are activated simultaneously. CLA SERIES Sound Selection Charts II 3 GD; INTRINSICALLY-SAFE 94/9/EC CENELEC: EN60079-15, EN61241-11, EN61241-0 Pre-recorded on model EWH24E/EXN Stutter + Bell Inverted Revelle Annie Laurie Synthesized Melody Galactic Motor London Bridge Bell Chime Ringing Phone Marys Lamb Yelp Call Sign Two Tone Camptown Races Rapid Hi Lo Train Ride Alarm Clock Amaryllis Explosion-safe for gas and dust Suitable for Zone 2 and Zone 22 CE compliance in accordance to ATEX Melody Chime Galloping Hi Lo Ringing Hi Lo Symphony #40 Synthesized Piano Alien Chatter Fur Elise Ave Maria Synthesized Bell Falling Crystals Minuet Grandfather's Clock 100mm, 200mm and 300mm long 100mm: 140 lx, 200mm: 270 lx, 300mm: 400 lx 24VDC (polarized) Dimensions 15 Model Rated Voltage EWH24E/ EXN 12/24V AC/DC Specifications Operating Power Voltage Range Consumption Volume Outer Contact Capacity Temperature Range 8~28V AC 9~35V DC 8W Max. 105dB at 1m No more than 5A -20C~+60C Humidity 85% or less. Auxiliary Input Channel 8ch/1bit EWH: Non-voltage Contact or 32ch/binary Protection Rating IP65 Mass 1.2kg S24 Models CLA1S24CD/EXN CLA1S24CN/EXN CLA2S24CD/EXN CLA2S24CN/EXN CLA3S24CD/EXN CLA3S24CN/EXN Luminous Color Daylight Natural White Daylight Natural White Daylight Natural White Length (Unit: mm) Rated Voltage Operating Voltage Range 100mm 200mm 300mm 1 2 3 25 DC24V10 LED color CD CN 100mm 200mm Daylight 6800K Natural white 4800K 300mm Rear Attachment (Magnetic Mount) Model SZ-310ARM Side Attachment (Screw Mount) Model SZ-310AS Side Attachment Model SZ-310ASB *Stainless steel brackets are also available. Rated Current Center Radiation Consumption lx/50cm 104mA DC 24V (Polarized) CLA3S24CD/EXN Options / EXN Length 3-4.2Beveled Specifications IP66, IP67 and IP69K rated -40C +60C Polycarbonate Mounting brackets available CLA CLA1S:124, CLA2S:224, CLA3S:324 30 Beep Stutter 140 208mA 270 240mA 400 Main Body Material Operating Temperature Range Body: (RH 90 or less Polycarbonate No Condensation) Mounting Direction Protection Rating Vibration Resistance Mass Any Direction (Indoor Use) IP66/67/69K 19.6m/s2 130 80 180 16 RES-A Heavy Duty Revolving Warning Light for Harsh Environment RLR Robust Heavy Duty 11.2G LED Super Bright Beacons for Harsh Environment Robust Heavy Duty Revolving Warning Light ]<< < !] { ^_ _ {? ? @ ? Q; Q | | Q; ?; @ _{ ?@ <[ ]] ]]<<