DMF-50840NB-FW-BEN (BE) No.2005-0301 OPTREX CORPORATION Page 1/18
LCD Module Technical Specification
DMF-50840NB-FW-BEN
Table of Contents
1. General Specifications...............................................................................................................................2
2. Electrical Specifications............................................................................................................................3
3. Optical Specifications ................................................................................................................................8
4. I/O Terminal.................................................................................................................................................10
5. Test.................................................................................................................................................................12
6. Appearance Standards.............................................................................................................................13
7. Code System of Production Lot.........................................................................................................16
8. Type Number...............................................................................................................................................16
9. Applying Precautions ...............................................................................................................................16
10. Precautions Relating Product Handling............................................................................................17
11. Warranty.......................................................................................................................................................18
Revision History
Rev. Date Page Comment
Type No.
Sep 5, 2005
First Edition
Final Revision
******
Checked by (ACI Engineering Division)
)
Approved by (Quality Assurance Division)
)
Prepared by (ACI Engineering Division)
T.Yuchi
DMF-50840NB-FW-BEN (BE) No.2005-0301 OPTREX CORPORATION Page 2/18
1. General Specifications
Operating Temp. min. 0 max. 50
Storage Temp. min. -20 max. 60
Dot Pixels 320 (W) × 240 (H) dots
Dot Size 0.33 (W) × 0.33 (H) mm
Dot Pitch 0.36 (W) × 0.36 (H) mm
Viewing Area 120.0 (W) × 90.0 (H) mm
Outline Dimensions 167.1 (W) × 109.0*1 (H) × 11.0 max. *2(D) mm
*1 Without Connector
*2 Without CFL Cable
Weight 230g max.
LCD Type NTD-15885
( STN / Blue-mode / Transmissive )
Viewing Angle 6:00
Data Transfer 4-bit parallel data transfer
Backlight Cold Cathode Fluorescent Lamp (CFL) × 1
Drawings Dimensional Outline UE-36988A
RoHS regulation   :To our best knowledge, this product satisfies material
requirement of RoHS regulation.
Our company is doing the best efforts to obtain
the equivalent certificate from our suppliers.
DMF-50840NB-FW-BEN (BE) No.2005-0301 OPTREX CORPORATION Page 3/18
2. Electrical Specifications
2.1. Absolute Maximum Ratings VSS=0V
Parameter Symbol Conditions Min. Max. Units
Supply Voltage
(Logic)
VCC-VSS -0.3 7.0 V
Supply Voltage
(LCD Drive)
VCC-VEE 035.0 V
Input Voltage VI-0.3 VCC+0.3 V
2.2. DC Characteristics Ta=25, VSS=0V
Parameter Symbol Conditions Min. Typ. Max. Units
Supply Voltage
(Logic)
VCC-VSS 4.5 5.5 V
Supply Voltage
VCC-VEE 27.1 30.0 V
(LCD Drive) VCC-VADJ Shown in 3.1 V
High Level
Input Voltage
VIH VCC=5.0V±10% 0.8×VCC VCC V
Low Level
Input Voltage
VIL VCC=5.0V±10% 00.2×VCC V
Supply Current
ICC VCC-VSS=5.0V 5.5 15.0 mA
IEE VCC-VADJ=23.3V5.0 10.0 mA
DMF-50840NB-FW-BEN (BE) No.2005-0301 OPTREX CORPORATION Page 4/18
2.3. AC Characteristics VCC=5.0V±10%
Parameter Symbol Min. Max. Units
CP Frequency fCP 6.0 MHz
Clock Pulse Width tWC 50 ns
Load Pulse Width tWL 63 ns
Data Setup Time tSETUP 30 ns
Data Hold Time tHOLD 30 ns
Clock Pulse Setup Time tCL 80 ns
Clock Pulse Hold Time tLC 110 ns
Rise/Fall Time tr, tfNote 1 ns
FLM Setup Time tFDS 100 ns
FLM Hold Time tFDH 100 ns
Note 1:The rise and fall times (tr, tf ) must satisfy the following relationships (and ).
         tWC
tr, tf 50 ns
This module contain these capacitors. Please be careful about timing characteristics.
1
t
r,
t
f
1000pF
1000pF
470pF
FLM
LP
VSS
M
2fCP
t
r
tf
t
f
t
t
SETUP
t
WC
t
LC
t
CL
CP
LOAD
DI 0DI 3
t
WL
t
WC
tr
t
FDH
t
FDS
FLM
DMF-50840NB-FW-BEN (BE) No.2005-0301 OPTREX CORPORATION Page 5/18
2.4. Timing Chart
2.5. Comparison of Display and Data
T=0.0556ms typ.
240
×
T
FLM
LP
FLM
D3
D0
CP
LP
#1 DATA
SEGSEG SEGSEG SEGSEG SEGSEG
320316 84 320316 84
317
313 5
1
317
313 5
1
(Reduction)
(Reduction)
SEG1
SEG320
#1
#240
D2
D3
D0
D3
TOP VIEW
D0
D1
D0
D1
DMF-50840NB-FW-BEN (BE) No.2005-0301 OPTREX CORPORATION Page 6/18
2.6. Power Supply ON/OFF Sequence
2.6.1. ON Sequence
2.6.2. OFF Sequence
Please maintain the above sequence when turning on and off the power supply of the
module.
If DISPOFF is supplied to the module while internal alternate signal for LCD driving (M) is
unstable, DC component will be supplied to the LCD panel. This may cause damage the
LCD module.
VCC
VSS
VEE
VSS
VSS
VCC
VSS
DISPOFF
VCC
VCC
VEE
0t
SIGNAL
0t
SIGNAL
VCC
LEVEL
0t
VADJ
VADJ
VCC
VSS
VEE
VSS
VSS
VCC
VSS
DISPOFF
VCC
VCC
VEE
0t
SIGNAL
0t
SIGNAL
VCC
LEVEL
0t
VADJ
VADJ
DMF-50840NB-FW-BEN (BE) No.2005-0301 OPTREX CORPORATION Page 7/18
2.7. Lighting Specifications Ta=25
Parameter Symbol Conditions Min. Typ. Max. Units Notes
Lamp Voltage VL 340 Vrms 1
Lamp Current IL3.0 4.0 5.0 mArms 2
Starting Voltage VS850 Vrms 3
Surface Luminance LIL=4.0mA 60 cd/4
Average Life TAL IL=4.0mA 20000 hrs 5
Brightne Ratio BIL=4.0mA 70 %
Note 1 :The voltage ( r.m.s. ) to maintain the electric discharge of the lamp. It is measured after
lighting for 3 minutes .
Note 2 :The current ( r.m.s. ) to flow through the lamp with the electric discharge. It is measured
after lighting for 3 minutes.
Note 3 :The voltage at starting the electric discharge when the voltage is increased gradually from
0V.
Note 4 :Surface Luminance is specified by the average of 9 luminance values measured at each
point shown above after 20 minutes power on with the all ON pattern adjusted to maximum
contrast and the dimming control of 100%. ( maximum brightness )
Note 5 :CFL life is defined as the time for which the initial luminance is attenuated by 50% of the
luminance value. Average Life representes the time elapsed at the point of time when the
residual ratio becomes below 50% when plural lamps are lighted in comparison with the
definition of life mentioned above.
Recommended Inverter : S-12561 ( Produced by ELEVAM )
CXA-L10L (DC 12.0V, Produced by TDK)
V
N
I
CFL Testing Circuit
L
F
C
VS
VL
IL
Measurement Points
P7
P4
P1
X=120
X=60
X=180
Y=260Y=160Y=60
P8
P5
P2
P9
P6
P3
DMF-50840NB-FW-BEN (BE) No.2005-0301 OPTREX CORPORATION Page 8/18
3. Optical Specifications
3.1. LCD Driving Voltage
Parameter Symbol Conditions Min. Typ. Max. Units
Recommended Ta= 0 27.1 V
LCD Driving Voltage VCC-VADJ Ta=2521.7 23.324.9 V
Note 1 Ta=5019.9 V
Note 1 : Voltage (Applied actual waveform to LCD Module) for the best contrast. The range of
minimum and maximum shows tolerance of the operating voltage. The specified contrast
ratio and response time are not guaranteed over the entire range.
3.2. Optical Characteristics Ta=25, 1/240Duty, 1/14Bias, VD=22.7V (Note 4), θ= 0, φ=
Parameter Symbol Conditions Min. Typ. Max. Units
Contrast Ratio Note 1 CR θ= 0, φ=5
Viewing Angle Shown in 3.3
Response Rise Note 2 TON 270 400 ms
Time Decay Note 3 TOFF 400 600 ms
Note 1 :Contrast ratio is definded as follows.
CR = LON / LOFF
LON :Luminance of the ON segments
LOFF :Luminance of the OFF segments
Note 2 :The time that the luminance level reaches 90% of the saturation level from 0% when
ON signal is applied.
Note 3 :The time that the luminance level reaches 10% of the saturation level from 100% when
OFF signal is applied.
Note 4 :Definition of Driving Voltage VD
VD=VCC-VADJ-VBE
Assuming that the typical driving waveforms shown below are applied to the LCD Panel
at 1/A Duty - 1/B Bias ( A : Duty Number, B : Bias Number ). Driving voltage VD is
definded as the voltage VO-P when the contrast ratio (CR=LON / LOFF) is at its
maximum.
V
O-P
1 /
f
F
( B-2 )
×
V
O-P
/ B
1 / (
f
F
×
A )
OFF SIGNAL
ON SIGNAL
DMF-50840NB-FW-BEN (BE) No.2005-0301 OPTREX CORPORATION Page 9/18
3.3. Definition of Viewing Angle and Optimum Viewing Area
Point shows the point where contrast ratio is measured. : θ= 0, φ=
Driving condition : 1/240Duty, 1/14Bias, VD=22.7V, fF=75Hz
Area shows typ. CR2
3.4. System Block Diagram
φ
Halogen bulb
Computer
Rotation Table (
θ
,
φ
)
Temperature Chamber
LCD
Optical Fiber
Waveform Generator
Control Unit &
#1980A WB
Photometer
θ
0
90
180
270
θ
φ
270
135
315 225
45
180
90
θ(φ= 0
φ
10
20
30
40
50
DMF-50840NB-FW-BEN (BE) No.2005-0301 OPTREX CORPORATION Page 10/18
4. I/O Terminal
4.1. Pin Assignment
CN1
No. Symbol Level Function
1D0 H / L Display Data
2D1 H / L Display Data
3D2 H / L Display Data
4D3 H / L Display Data
5DISPOFF H / L H : Display on L : Display off (Pull up Resister)
6FLM H / L First Line Marker
7NC Non-connection
8LP HLData Latch Signal
9CP HLClock Signal for Shifting Data
10 VCC Power Supply for Logic
11 VSS Power Supply (0V, GND)
12 VEE Power Supply for LCD Drive
13 VADJ Voltage Level for LCD Contrast Adjustment
14 FG Frame Ground
CN2
No. Symbol Level Function
5CFL HOT Power Supply for CFL (HOT)
6NC Non-connection
7NC Non-connection
8CFL GND Power Supply for CFL (GND)
4.2. Example of Power Supply
It is recommended to apply a potentiometer for the contrast adjust due to the
tolerance of the driving voltage and its temperature dependence.
MODULE
VADJ
VCC
VEE
VSS
VSS (0V)
VCC (+Voltage)
R1+R2+VR=10
20
K
Ω
VEE (-Voltage)
R2
R1
VR
DMF-50840NB-FW-BEN (BE) No.2005-0301 OPTREX CORPORATION Page 11/18
4.3. Block Diagram
CFL GND
CFL HOT
VEE
VADJ
VSS
VCC
D0D3
CP
FLM
LP
DISPOFF
or equivalent
LC79431D × 3
Row Driver
LC79401D × 4
Column Driver
L C D P
320
240
4
LP
2
2
320 × 240 dots
M Circuit
To LSIBias Circuit
CFL Backlight
or equivalent
DMF-50840NB-FW-BEN (BE) No.2005-0301 OPTREX CORPORATION Page 12/18
5. Test
No change on display and in operation under the following test condition.
No. Parameter Conditions Notes
1High Temperature Operating 50℃±2, 96hrs (operation state)
2Low Temperature Operating 0℃±2, 96hrs (operation state) 3
3High Temperature Storage 60℃±2, 96hrs 4
4Low Temperature Storage -20℃±2, 96hrs 3, 4
5Damp Proof Test 40℃±2, 9095%RH, 96hrs 3, 4
6Vibration Test Total fixed amplitude : 1.5mm 5
Vibration Frequency : 1055Hz
One cycle 60 seconds to 3 directions of X, Y, Z for
each 15 minutes
7Shock Test To be measured after dropping from 60cm high on
the concrete surface in packing state.
Note 1 :Unless otherwise specified, tests will be conducted under the following condition.
Temperature : 20±5
Humidity : 65±5%
Note 2 :Unless otherwise specified, tests will be not conducted under functioning state.
Note 3 :No dew condensation to be observed.
Note 4 :The function test shall be conducted after 4 hours storage at the normal temperature and
humidity after removed from the test chamber.
Note 5 :Vibration test will be conducted to the product itself without putting it in a container.
E
A
G
D
C
F
60cm
Concrete Surface
Dropping method corner dropping
E,F,G face : once
B,C,D edge : once
A corner : once
Face dropping
Edge dropping
B
DMF-50840NB-FW-BEN (BE) No.2005-0301 OPTREX CORPORATION Page 13/18
6. Appearance Standards
6.1. Inspection conditions
The LCD shall be inspected under 40W white fluorescent light.
The distance between the eyes and the sample shall be more than 30cm.
All directions for inspecting the sample should be within 45 against perpendicular line.
6.2. Definition of applicable Zones
A Zone : Active display area
B Zone : Area from outside of "A Zone" to validity viewing area
C Zone : Rest parts
A Zone + B Zone = Validity viewing area
45
X
A Zone
B Zone
C Zone
C Zone
X=120.0mm
Y=90.0mm
Bezel Flame
DMF-50840NB-FW-BEN (BE) No.2005-0301 OPTREX CORPORATION Page 14/18
6.3. Standards
No. Parameter Criteria
1Black and (1) Round Shape
White Spots, Zone Acceptable Number
Foreign Substances Dimension (mm) A B C
D 0.1 * * *
0.1 D 0.2 35*
0.2 D 0.25 23*
0.25 D 0.3 01*
0.3 D 00*
D = ( Long + Short ) / 2 * : Disregard
(2) Line Shape
Zone Acceptable Number
X (mm) Y (mm) A B C
0.03W* * *
2.0L0.05W33*
1.0L0.1 W33*
0.1 WIn the same way (1)
X : Length Y : Width * : Disregard
Total defects shall not exceed 5.
2Air Bubbles
(between glass Zone Acceptable Number
& polarizer) Dimension (mm) A B C
D 0.3 * * *
0.3 D 0.4 3* *
0.4 D 0.6 23*
0.6 D 00*
* : Disregard
Total defects shall not exceed 3.
DMF-50840NB-FW-BEN (BE) No.2005-0301 OPTREX CORPORATION Page 15/18
No. Parameter Criteria
3The Shape of Dot (1) Dot Shape (with Dent)
As per the sketch of left hand.
(2) Dot Shape (with Projection)
Should not be connected to next dot.
(3) Pin Hole
(X+Y) / 20.2mm
(Less than 0.1mm is no counted.)
(4) Deformation
(X+Y) / 20.2mm
Total acceptable number : 1/dot, 5/cell
(Defect number of (4) : 1pc.)
4Polarizer Scratches Not to be conspicuous defects.
5Polarizer Dirts If the stains are removed easily from LCDP surface, the module is not
defective.
6Complex Foreign Black spots, line shaped foreign substances or air bubbles between
Substance Defects glass & polarizer should be 5pcs maximum in total.
7Distance between D0.2 : 20mm or more
Different Foreign 0.2D : 40mm or more
Substance Defects
0.15
Y
X
X
Y
DMF-50840NB-FW-BEN (BE) No.2005-0301 OPTREX CORPORATION Page 16/18
7. Code System of Production Lot
The production lot of module is specified as follows.
Factory Control Number (0~99)
Date of the week (A~G)
Factory Number (0~9)
Factory Code (Alphabet)
Production Week (1~5)
Production Month (1~9, X, Y, Z)
Production Year (Lower 2 digits)
8. Type Number
The type number of module is specified as follows.
DMF-50840NB-FW-BEN
9. Applying Precautions
Please contact us when questions and/or new problems not specified in this
Specifications arise.
DMF-50840NB-FW-BEN (BE) No.2005-0301 OPTREX CORPORATION Page 17/18
10. Precautions Relating Product Handling
The Following precautions will guide you in handling our product correctly.
1) Liquid crystal display devices
1. The liquid crystal display device panel used in the liquid crystal display module is
made of plate glass. Avoid any strong mechanical shock. Should the glass break
handle it with care.
2. The polarizer adhering to the surface of the LCD is made of a soft material.
Guard against scratching it.
2) Care of the liquid crystal display module against static electricity discharge.
1. When working with the module, be sure to ground your body and any electrical
equipment you may be using. We strongly recommend the use of anti static mats
( made of rubber ), to protect work tables against the hazards of electrical shock.
2. Avoid the use of work clothing made of synthetic fibers. We recommend cotton
clothing or other conductivity-treated fibers.
3. Slowly and carefully remove the protective film from the LCD module, since this
operation can generate static electricity.
3) When the LCD module alone must be stored for long periods of time:
1. Protect the modules from high temperature and humidity.
2. Keep the modules out of direct sunlight or direct exposure to ultraviolet rays.
3. Protect the modules from excessive external forces.
4) Use the module with a power supply that is equipped with an overcurrent protector
circuit,since the module is not provided with this protective feature.
5) Do not ingest the LCD fluid itself should it leak out of a damaged LCD module. Should
hands or clothing come in contact with LCD fluid, wash immediately with soap.
6) Conductivity is not guaranteed for models that use metal holders where solder
connections between the metal holder and the PCB are not used. Please contact us
to discuss appropriate ways to assure conductivity.
7) For models which use CFL:
1. High voltage of 1000V or greater is applied to the CFL cable connector area.
Care should be taken not to touch connection areas to avoid burns.
2. Protect CFL cables from rubbing against the unit and thus causing the wire jacket to
become worn.
3. The use of CFLs for extended periods of time at low temperatures will significantly
shorten their service life.
8) For models which use touch panels:
1. Do not stack up modules since they can be damaged by components on neighboring
modules.
2. Do not place heavy objects on top of the product. This could cause glass breakage.
9) For models which use COG,TAB,or COF:
1. The mechanical strength of the product is low since the IC chip faces out unprotected
from the rear. Be sure to protect the rear of the IC chip from external forces.
2. Given the fact that the rear of the IC chip is left exposed, in order to protect the unit
from electrical damage, avoid installation configurations in which the rear of the IC
chip runs the risk of making any electrical contact.
DMF-50840NB-FW-BEN (BE) No.2005-0301 OPTREX CORPORATION Page 18/18
10) Models which use flexible cable, heat seal, or TAB:
1. In order to maintain reliability, do not touch or hold by the connector area.
2. Avoid any bending, pulling, or other excessive force, which can result in broken
connections.
11) In case of buffer material such as cushion / gasket is assembled into LCD module,
it may have an adverse effect on connecting parts ( LCD panel-TCP / HEAT SEAL / FPC /
etc., PCB-TCP / HEAT SEAL / FPC etc., TCP-HEAT SEAL, TCP-FPC, HEAT SEAL-FPC,
etc.,) depending on its materials.
Please check and evaluate these materials carefully before use.
12) In case of acrylic plate is attached to front side of LCD panel, cloudiness ( very small
cracks ) can occur on acrylic plate, being influenced by some components generated
from polarizer film..
Please check and evaluate those acrylic materials carefully before use.
11. Warranty
This product has been manufactured to your company’s specifications as a part for use in
your company’s general electronic products. It is guaranteed to perform according to
delivery specifications. For any other use apart from general electronic equipment, we
cannot take responsibility if the product is used in medical devices, nuclear power control
equipment, aerospace equipment, fire and security systems, or any other applications in
which there is a direct risk to human life and where extremely high levels of reliability are
required. If the product is to be used in any of the above applications, we will need to enter
into a separate product liability agreement.
1. We cannot accept responsibility for any defect, which may arise from additional
manufacturing of the product (including disassembly and reassembly), after
product delivery.
2. We cannot accept responsibility for any defect, which may arise after the application
of strong external force to the product.
3. We cannot accept responsibility for any defect, which may arise due to the application
of static electricity after the product has passed your company’s acceptance inspection
procedures.
4. When the product is in CFL models, CFL service life and brightness will vary
According to the performance of the inverter used, leaks, etc. We cannot accept
responsibility for product performance, reliability, or defect, which may arise.
5. We cannot accept responsibility for intellectual property of a third party, which may
arise through the application of our product to your assembly with exception to those
issues relating directly to the structure or method of manufacturing of our product.
6. Optrex will not be held responsible for any quality guarantee issue for defect products
judged as Optrex-origin longer than 2 (two) years from Optrex production or 1(one)
year from Optrex, Optrex America, Optrex Europe delivery which ever comes later.