MAX16927 Evaluation Kit
Evaluates: MAX16927
8 ______________________________________________________________________________________
stated by the number inside their respective preceding
parentheses, and likewise for Seq 2 and Seq 3.
VCOMH, VCOML, DAC Direction, DAC Value
The EV kit software features a panel that contains
the VCOMH and VCOML status displays, the DAC
Direction radio group box, and the DAC Value edit
box. The VCOMH and VCOML status boxes display the
VCOMH and VCOML ON/Off states. The DAC Direction
radio group box selects the DAC’s Positive or Negative
direction. The DAC Value edit box accepts a hex
number between 00 and 7F to scale the VCOMH or
VCOML values. The VCOML values are scaled to
between 0 and +1V when the DAC Direction is Positive,
or between 0 and -1V when the DAC Direction is
Negative.
Over Temperature
The EV kit software features a panel that displays
the device’s overtemperature condition. The Over
Temperature panel displays On when the device’s
internal die temperature exceeds +165NC (typ).
Fault Condition
The EV kit software features a panel that displays the
device’s fault condition. The Fault Condition panel dis-
plays On when one or more of the device’s output volt-
ages (except for the buck-converter output) is less than
85% of their regulated values.
Reset
The Reset button resets the EV kit to the following
condition: +3.3V (EN3) = Disabled, Input Pwr (ENP)
= Disabled, Power Sequence (EN2, EN1) = Seq 0:
SPI determines which regulator is on, DAC Direction
= Positive, DAC Value = 00, VSH = Disabled, VSH
Current Limit = 100%, VSH Soft Start = checked, VSL
= Disabled, VSL Current Limit = 100%, VSL Soft Start
= checked, VSLS = Disabled, VGH = Disabled, VGH
Soft Start Time = 6.784 mSec, VGL = Disabled, and
VGL Soft Start Time = 6.784 mSec.
VSH Enabled/Disabled, Current Limit,
VSH Soft-Start, and VSH Status
The EV kit software features a panel that includes the
VSH Enabled/Disabled radio buttons, the Current Limit
drop-down list, the VSH Soft Start checkbox, and the
VSH Status display. The VSH Enabled/Disabled radio
buttons enable or disable the VSH regulator. Enable
the +3.3V (EN3) and Input Pwr (ENP) before enabling
VSH. The Current Limit drop-down list selects the VSH
current limit. The VSH Soft Start checkbox enables or
disables the VSH soft-start feature. VSH Status displays
the VSH On/Off status.
VSL Enabled/Disabled, Current Limit,
VSL Soft-Start, and VSL Status
The EV kit software features a panel that includes the
VSL Enabled/Disabled radio buttons, the Current Limit
drop-down list, the VSL Soft Start checkbox, and the
VSL Status display. The VSL Enabled/Disabled radio
buttons enable or disable the VSL regulator. Enable the
+3.3V (EN3) and Input Pwr (ENP) before enabling VSL.
The Current Limit drop-down list selects the VSL current
limit. The VSL Soft Start check box enables or disables
the VSL soft-start feature. VSL Status displays the VSL
On/Off status.
VSLS Enabled/Disabled and VSLS Status
The EV kit software features a panel that includes
the VSLS Enabled/Disabled radio buttons and the
VSLS Status display. The VSLS Enabled/Disable radio
buttons enable or disable the VSLS switch. Enable the
+3.3V (EN3), Input Pwr (ENP), and VSL before enabling
VSLS. VSLS Status displays the VSLS On/Off status.
VGH Enabled/Disabled, Soft-Start Time,
and VGH Status
The EV kit software features a panel that includes the
VGH Enabled/Disabled radio buttons, the Soft Start
Time drop-down list, and the VGH Status display. The
VGH Enabled/Disabled radio buttons enable or disable
the VGH regulator. Enable the +3.3V (EN3), Input Pwr
(ENP), VSH, and VSL before enabling VGH. The Soft
Start Time drop-down list selects the VGH soft-start
time. VGH Status displays the VGH On/Off status.
VGL Enabled/Disabled, Soft-Start Time,
and VGL Status
The EV kit software features a panel that includes the
VGL Enabled/Disabled radio buttons, the Soft Start
Time drop-down list, and the VGL Status display. The
VGL Enabled/Disabled radio buttons enable or disable
the VGL regulator. Enable the +3.3V (EN3), Input Pwr
(ENP), VSH, and VSL before enabling VGL. The Soft
Start Time drop-down list selects the VGL soft-start time.
VGL Status displays the VGL On/Off status.
Keyboard Navigation
Press the Tab key to select each GUI control. Most of the
selected control is indicated by a dotted outline. Using
Shift + Tab moves the selection to the previously select-
ed control. Buttons respond to the keyboard’s space bar.
Some controls respond to the keyboard’s up-and-down
arrow keys. Activate the program’s menu bar by press-