General-purpose Relay MY Versatile and Function-filled Miniature Power Relay for Sequence Control and Power Switching Applications * Models with lockable test buttons now available. * Many variations possible through a selection of operation indicators (mechanical and LED indicators), lockable test button, built-in diode and CR (surge suppression), bifurcated contacts, etc. * Arc barrier standard on 4-pole Relays. * Dielectric strength: 2,000 VAC (coil to contact) * Environment-friendly cadmium-free contacts. * Safety standard approvals obtained. * Wide range of Sockets (PY, PYF Series) and optional parts are available. * Max. Switching Current: 2-pole: 10 A, 4-pole: 5 A * Provided with nameplate. LR Ordering Information Relays Standard Coil Polarity Type Contact form Plug-in socket/Solder terminals Standard with LED indicator Standard With built-in diode (DC only) Without LED indicator With LED indicator and lockable test button DPDT MY2N MY2IN MY2 4PDT MY4N MY4IN MY4 4PDT (bifurcated) MY4ZN MY4ZIN MY4Z DPDT MY2N-D2 MY2IN-D2 --- 4PDT MY4N-D2 MY4IN-D2 --- 4PDT (bifurcated) MY4ZN-D2 MY4ZIN-D2 --- MY2N-CR MY2IN-CR --- MY4N-CR MY4IN-CR --- MY4ZN-CR MY4ZIN-CR --- With built-in CR DPDT (220/240 VAC, 110/120 VAC on4PDT ly) 4PDT (bifurcated) Reverse Coil Polarity Type Contact form Plug-in socket/Solder terminals With LED indicator Standard (DC only) With built-in diode (DC only) With LED indicator and lockable test button DPDT MY2N1 MY2IN1 4PDT MY4N1 MY4IN1 4PDT (bifurcated) MY4ZN1 MY4ZIN1 DPDT MY2N1-D2 MY2IN1-D2 4PDT MY4N1-D2 MY4IN1-D2 4PDT (bifurcated) MY4ZN1-D2 MY4ZIN1-D2 Note: When ordering, add the rated coil voltage and "(s)" to the model number. Rated coil voltages are given in the coil ratings table. Example: MY2 6VAC (S) Rated coil voltage General-purpose Relay MY 1 Accessories (Order Separately) Sockets Poles Front Mounting Socket (DIN-rail/ screwless clamp [SLC]) Front-mounting Socket (DIN-rail/ screw mounting) Back-mounting Socket Solder terminals Without clip Wire-wrap terminals With clip Without clip PCB terminals With clip 2 PYF08S PYF08A-E PYF08A-N PY08 PY08-Y1 PY08QN PY08QN2 PY08QN-Y1 PY08QN2-Y1 PY08-02 4 PYF14S PYF14A-E PYF14A-N PYF14-ESS-B PYF14-ESN-B PY14 PY14-Y1 PY14QN PY14QN2 PY14QN-Y1 PY14QN2-Y1 PY14-02 Socket Hold-down Clip Pairing Relay type Poles Front Mounting Socket (DIN-rail/screwless clamp [SLC]) Front-connecting Socket (DIN-rail screw mounting) Socket Without 2-pole 2 test button PYF08S PYCM-08S PYF08A-E PYF08A-N 4 PYF14S PYCM-14S PYF14A-E PYF14A-N 2-pole test button 2 PYF08S PYCM-08S Back-connecting Socket Solder/Wire-wrap terminals Clip Socket PYC-A1 PY08(QN) PYC-P PYC-P2 PY14(QN) PYF14-ESS-B PYF14-ESN-B PYC-0 (metal) PYC35-B (plastic) PYF08A-E PYF08A-N PYC-E1 PY08(QN) PCB terminals Clip Socket PY08-02 Clip PYC-P PYC-P2 PY14-02 PYC-P2 PY08-02 PYC-P2 Mounting Plates for Sockets Socket model For 1 Socket PY08, PY08QN(2), PY14, PY14QN(2) For 18 Sockets PYP-1 For 36 Sockets PYP-18 PYP-36 Note: PYP-18 and PYP-36 can be cut into any desired length in accordance with the number of Sockets. DIN-rail and Accessories Supporting DIN-rail (length = 500 mm) PFP-50N Supporting DIN-rail (length = 1,000 mm) PFP-100N, PFP-100N2 End Plate PFP-M Spacer PFP-S Specifications Coil Ratings Rated voltage Rated current 50 Hz AC DC Coil resistance 60 Hz Coil inductance (reference value) Arm. OFF Arm. ON 6 V* 214.1 mA 183 mA 12.2 0.04 H 0.08 H 12 V 106.5 mA 91 mA 46 0.17 H 0.33 H 24 V 53.8 mA 46 mA 180 0.69 H 1.30 H 48/50 V* 24.7/ 25.7 mA 21.1/ 22.0 mA 788 3.22 H 5.66 H 110/120 V 9.9/10.8 mA 8.4/9.2 mA 4,430 19.20 H 32.1 H 220/240 V 4.8/5.3 mA 4.2/4.6 mA 18,790 83.50 H 136.4 H 6 V* 151 mA 39.8 0.17 H 0.33 H 12 V 75 mA 160 0.73 H 1.37 H 24 V 37.7 mA 636 3.20 H 5.72 H 48 V* 18.8 mA 2,560 10.60 H 21.0 H 100/110 V 9.0/9.9 mA 11,100 45.60 H 86.2 H Must operate voltage Must release voltage Max. voltage Power consumption (approx.) % of rated voltage 80% max. 30% min. 110% 1.0 to 1.2 VA (60 Hz) 0.9 to 1.1 VA (60 Hz) 10% min. 0.9 W Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with tolerances of +15%/-20% for rated currents and 15% for DC coil resistance. 2. Performance characteristic data are measured at a coil temperature of 23C. 3. AC coil resistance and impedance are provided as reference values (at 60 Hz). 4. Power consumption drop was measured for the above data. When driving transistors, check leakage current and connect a bleeder resistor if required. 5. Rated voltage denoted by "*" will be manufactured upon request. Ask your OMRON representative. 2 General-purpose Relay MY Contact Ratings Item 2-pole Resistive load (cos = 1) Rated load 4-pole Inductive load (cos = 0.4, L/R = 7 ms) 5A, 250 VAC 5A, 30 VDC 2A, 250 VAC 2 A, 30 VDC Resistive load (cos = 1) 3 A, 250 VAC 3 A, 30 VDC Carry current 10 A (see note) 5 A (see note) Max. switching voltage 250 VAC 125 VDC 250 VAC 125 VDC Max. switching current 10 A 5A Max. switching power 2,500 VA 300 W Failure rate (reference value) 5 VDC, 1 mA 1,250 VA 300 W 1,250 VA 150 W 4-pole (bifurcated) Inductive load (cos = 0.4, L/R = 7 ms) Resistive load (cos = 1) Inductive load (cos = 0.4, L/R = 7 ms) 0.8 A, 250 VAC 1.5 A, 30 VDC 3 A, 250 VAC 3 A, 30 VDC 0.8 A, 250 VAC 1.5 A, 30 VDC 500 VA 150 W 1,250 VA 150 W 500 VA 150 W 1 VDC, 100 A 1 VDC, 1 mA Note: Don't exceed the carry current of a Socket in use. Please see page G-10. Characteristics Item All Relays Contact resistance 100 m max. Operate time 20 ms max. Release time 20 ms max. Max. operating frequency Mechanical: 18,000 operations/hr Electrical: 1,800 operations/hr (under rated load) Insulation resistance 1,000 M min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1.0 min (1,000 VAC between contacts of same polarity) Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude) Malfunction: 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude) Shock resistance Destruction: 1,000 m/s2 Malfunction: 200 m/s2 Endurance See the following table. Ambient temperature Operating: -55C to 70C (with no icing) Ambient humidity Operating: 5% to 85% Weight Approx. 35 g Note: The values given above are initial values. Endurance Characteristics Pole 2-pole Mechanical life (at 18,000 operations/hr) Electrical life (at 1,800 operations/hr under rated load) AC:50,000,000 operations min. DC:100,000,000 operations min. 500,000 operations min. 4-pole 4-pole (bifurcated) 20,000,000 operations min. 100,000 operations min. 200,000 operations min. General-purpose Relay MY 3 Approved Standards VDE Recognitions (File No. 112467UG, IEC 255, VDE 0435) No. of poles 2 Coil ratings Contact ratings 6, 12, 24, 48/50, 100/110 110/120, 200/220, 220/240 VAC 6, 12, 24, 48, 100/110, 125 VDC 4 Operations 10 A, 250 VAC (cos=1) 10 A, 30 VDC (L/R=0 ms) 10 x 10 5 A, 250 VAC (cos=1) 5 A, 30 VDC (L/R=0 ms) 100 x 103 MY4Z AC; 50 x 103 3 UL508 Recognitions (File No. 41515) No. of poles 2 Coil ratings 6 to 240 VAC 6 to 125 VDC 4 Contact ratings 10 A, 30 VDC (General purpose) 10 A, 250 VAC (General purpose) Operations 6 x 10 3 5 A, 250 VAC (General purpose) 5 A, 30 VDC (General purpose) CSA C22.2 No. 14 Listings (File No. LR31928) No. of poles 2 Coil ratings 6 to 240 VAC 6 to 125 VDC 4 Contact ratings 10 A, 30 VDC 10 A, 250 VAC Operations 6 x 103 5 A, 250 VAC (Same polarity) 5 A, 30 VDC (Same polarity) IMQ (File No. EN013 to 016) No. of poles 2 Coil ratings 6, 12, 24, 48/50, 100/110 110/120, 200/220, 220/240 VAC 6, 12, 24, 48, 100/110, 125 VDC 4 Contact ratings Operations 10 A, 30 VDC 10 A, 250 VAC 10 x 103 5 A, 250 VAC 5 A, 30 VDC 100 x 103 MY4Z AC; 50 x 103 LR Recognitions (File No. 98/10014) No. of poles 2 Coil ratings 6 to 240 VAC 6 to 125 VDC 4 Contact ratings Operations 10 A, 250 VAC (Resistive) 2 A, 250 VAC (PF0.4) 10 A, 30 VDC (Resistive) 2 A, 30 VDC (L/R=7 ms) 50 x 103 5 A, 250 VAC (Resistive) 0.8 A, 250 VAC (PF0.4) 5 A, 30 VDC (Resistive) 1.5 A, 30 VDC (L/R=7 ms) 50 x 103 SEV Listings (File No. 99.5 50902.01) No. of poles 2 Coil ratings 6 to 240 VAC 6 to 125 VDC 4 4 General-purpose Relay MY Contact ratings Operations 10 A, 250 VAC 10 A, 30 VDC 10 x 10 5 A, 250 VAC 5 A, 30 VDC 100 x 103 MY4Z AC; 50 x 103 3 Engineering Data Maximum Switching Power AC resistive load AC inductive load (cos=0.4) DC resistive load Switching current (A) MY4, MY4Z Switching current (A) MY2 AC resistive load AC inductive load (cos=0.4) DC resistive load DC inductive load (L/R=7 ms) DC inductive load (L/R=7 ms) Switching voltage (V) Switching voltage (V) Endurance MY2 (Inductive Loads) 10000 5000 3000 250 VAC 1000 500 300 30 VDC 30 VDC 250 VAC 100 Endurance (x10 3operations) Endurance (x10 3 operations) MY2 (Resistive Loads) 10000 5000 3000 250 VAC 1000 500 300 30 VDC 30 VDC 250 VAC 100 50 30 50 30 10 10 Switching current (A) MY4 (Resistive Loads) MY4 (Inductive Loads) Endurance (x10 3 operations) Endurance (x10 3 operations) Switching current (A) 10000 5000 3000 250 VAC 1000 500 300 30 VDC 30 VDC 100 250 VAC 50 30 10 10000 5000 3000 30 VDC 1000 500 300 30 VDC 250 VAC 100 50 30 250 VAC 10 Switching current (A) Switching current (A) General-purpose Relay MY 5 MY4Z (Inductive Loads) Endurance (x10 3operations) Endurance (x10 3 operations) MY4Z (Resistive Loads) 10000 5000 3000 1000 250 VAC 500 300 30 VDC 100 30 VDC 50 30 10000 5000 3000 1000 250 VAC 10 30 VDC 500 300 30 VDC 100 250 VAC 50 30 250 VAC 10 Switching Current (A) Switching Current (A) Technical and Environmental Properties 2-Pole model 4-Pole model DIN-railing Resistance 600 CTI (base) 600 CTI (base) Environmental Protection RT1 RT1 Flammability Class Base, Insulator, Spool Case, Indicator, Nameplate, Push Button Pollution Degree 2 1 Creepage Distance 4.0 mm 3.2 mm Clearance Distance 3.0 mm 3.0 mm Contact Material Ag AgNi + Au ul 94V-0 ul 94V-2 Two-way action test button Relay in normal operation For momentary operation For lock operation 1 Push up the test button to the first position, then press the yellow button with an insulated tool to operate the contact. 6 General-purpose Relay MY 2 Push up the test button to the second position. (The contact is now in the locked position). Typical information for reference only The following data is provided as experimental and/or calculated data for reference only. These figures fall under the category of typical behaviour and the operation of individual relays will vary according to the exact operating conditions. Typical Operate / Release Times 2-Pole model AC Type (operate / release time) 8 ms/8 ms 4-Pole model 10 ms/10 ms DC Type (operate / release time) 14 ms/4 ms 14 ms/6 ms Load reduction Factor For AC inductive loads (such as solenoids, contactors coils, etc.) the reduction factor corresponding to cos(p.f.) (cosine of the power factor) is multiplied by the rated current in order to identify the maximum allowable current. This approximation is not valid for loads with high inrush currents such as electric motors or fluorescent lamps. 1 Reduction factor 0.8 0.6 0.4 1 0.8 0.6 0.4 0.2 cos(p.f.) Multiple Contact DC Switching Capacity Effect of temperature on coil voltages Switching capacity of DC resistive load MY2/4 Operating range (DC and AC type) vs ambient temperature 100 2 10 1.5 U/Un Switching Current (A) 1 MY4 2 1 1.0 4 contacts 3 contacts 2 contacts in series MY2 1: Max coil voltage permitted. 2: Min pick-up voltage with coil at ambient temperature 0,1 20 0.5 40 60 80 100 120 140 160 Switching Voltage (Vdc) 180 200 220 0 10 20 30 40 50 60 70 80 Ambient temperature (C) This graph can be used to estimate the number of contacts that can be This graph shows the typical relationship between the maximum / miniused to switch DC resistive loads mum coil and pick-up voltage and ambient temperature General-purpose Relay MY 7 Dimensions Note: All units are in millimeters unless otherwise indicated. 2-Pole Models MY2N 2.6 Eight, 1.2 dia. x 2.2 long holes 0.5 28 max. 36 max. 6.4 21.5 max. 4-Pole Models MY4N 2.6 Eight, 1.2 dia. x 2.2 long holes 0.5 28 max. 36 max. 6.4 21.5 max. Models with Test Button MY2IN 2.6 8 Eight, 1.2-dia. x 2.2 oval holes 6.3 0.5 28 max. 5 14.2 36 max. 8.05 6.4 MY4IN 21.5 max. 2.6 8 Fourteen, 1.2-dia. x 2.2 oval holes 6.3 0.5 28 max. 5 14.2 8 General-purpose Relay 8.05 MY 36 max. 6.4 21.5 max. Terminal Arrangement/Internal Connections (Bottom View) MY2 MY2N/MY2IN (AC Models) MY2N/MY2IN (DC Models) MY2N-D2/MY2IN-D2 (DC Models Only) 1 4 1 4 1 4 1 4 5 8 5 8 5 8 5 8 9 12 9 12 9 12 9 13 14 13 14 MY2N-CR/MY2IN-CR (AC Models Only) + 14 MY2N1/MY2IN1 (DC Models Only) 13 12 - + 14 MY2N1-D2/MY2IN1-D2 (DC Models Only) 1 4 1 4 1 4 5 8 5 8 5 8 9 12 9 12 9 13 MY4(Z) 13 - 14 MY4(Z)N/MY4(Z)IN (AC Models) 13 + - 14 MY4(Z)N/MY4(Z)IN (DC Models) 13 12 + - 14 MY4(Z)N-D/MY4(Z)IN-D2 (DC Models Only) 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 5 6 7 8 5 6 7 8 5 6 7 8 5 6 7 8 9 10 11 12 9 10 11 12 9 10 11 12 9 10 11 13 14 13 14 MY4(Z)N-CR/MY4(Z)IN-CR (AC Models Only) 13 - + 14 MY4(Z)N1/MY4(Z)IN1 (DC Models Only) 13 - 12 + 14 MY4(Z)N1-D2/MY4(Z)IN1-D2 (DC Models Only) 1 2 3 4 1 2 3 4 1 2 3 4 5 6 7 8 5 6 7 8 5 6 7 8 9 10 11 12 9 10 11 12 9 10 11 13 14 13 + - 14 13 + 12 - 14 Note: The DC models have polarity. General-purpose Relay MY 9 Sockets for MY DIN-rail-mounted (DIN-rail) Socket Conforms to VDE 0106, Part 100 * Snap into position along continuous sections of any mounting DIN-rail. * Facilitates sheet metal design by standardized mounting dimensions. * Design with sufficient dielectric separation between terminals eliminates the need of any insulating sheet. Safety Standards for Sockets Model Standards File No. PYF08A-E, PYF08A-N PYF14A-E, PYF14A-N UL508 E87929 CSA22.2 LR31928 PYF14-ESN-B, PYF14-ESS-B UL508 E244189 CSA22.2 LR225761 Back-connecting Sockets Specifications Item Pole Model Carry current Screwless Clamp Terminal Socket 2 PYF08S 10 A 4 PYF14S 5A DIN-rail-mounted Socket 2 PYF08A-E 7A PYF08A-N (see note 3) 7 A (see note 4) PYF14A-E 5A 4 Back-connecting Socket Dielectric withstand voltage Insulation resistance (see note 2) 2,000 VAC, 1 min Less than 1,000 M 2,000 VAC, 1 min 1,000 M min. PYF14A-N (see note 3) 5 A (see note 4) 4 PYF14-ESN-B/-ESS-B 12 A > 3 kV > 5 M 2 PY08(-Y1) 7A 1,500 VAC, 1 min 100 M min. PY08QN(-Y1) PY08-02 4 PY14(-Y1) 3A PY14QN(-Y1) PY14-02 Note: 1. 2. 3. 4. 5. 10 The values given above are initial values. The values for insulation resistance were measured at 500 V at the same place as the dielectric strength. The maximum operating ambient temperature for the PYF08A-N and PYF14A-N is 55C. When using the PYF08A-N or PYF14A-N at an operating ambient temperature exceeding 40C, reduce the current to 60%. The MY2(S) can be used at 70C with a carry current of 7 A. General-purpose Relay MY Dimensions Note: All units are in millimeters unless otherwise indicated. Socket Dimensions Terminal arrangement/ Internal connections (top view) Mounting holes 38.2 max. 36.5 max. PYF08S 23.2 max. --- 85 max. (5.3) PYF08A-E Two, M3, M4, or 4.5-dia. holes Two, 4.2 x 5 mounting holes Eight, M3 x 8 sems screws 72 max. (TOP VIEW) 23 max. Note: DIN-rail mounting is also possible. Refer to page G-15G-16 for supporting DIN-rails. 31 max. 22 max. PYF08A-N 4 1 42 12 8 5 44 14 42 4 44 8 12 1 14 5 3.0 dia. 18.7 67 max. 3.5 dia. or M3 73 PYF-08A-N 41 11 12 9 A2 A2 A1 14 14 13 12 9 41 11 14 14 13 A2 A2 A1 Note: DIN-rail mounting is also possible. Refer to page G-15G-16 for supporting DIN-rails. 30 max. General-purpose Relay MY 11 Socket Dimensions Terminal arrangement/ Internal connections (top view) Mounting holes 36.5 max. PYF14S 31 max. --- 85 max. PYF14A-E Two, 4.2 x 5 mounting holes Two, M3, M4, or 4.5-dia. holes Fourteen, M3 x 8 sems screws 72 max. (TOP VIEW) Note: DIN-rail mounting is also possible. Refer to page G-15G-16 for supporting DIN-rails. 29.5 max. 31 max. 42 4 44 8 PYF14A-N 4 3 2 1 42 32 22 12 8 7 6 5 44 34 24 14 32 3 34 7 22 2 24 6 12 1 14 5 Two, 4.5 dia. or M4 67 max. PYF-14A-N 41 31 21 11 12 11 10 9 A2 A2 A1 14 14 13 General-purpose Relay 12 11 10 9 41 31 21 11 30 max. 29.5 max. 12 26 73 MY 14 14 A2 A2 13 A1 Note: DIN-rail mounting is also possible. Refer to page G-15G-16 for supporting DIN-rails. Socket Dimensions Terminal arrangement/ internal connections (top view)/ mounting holes PYF14-ESN-B 27 42.5 Label NO 27 NC 9 4.45 4.45 4.45 4.1 6.3 Relay 6.4 82 75 3.2 COIL COM. 24 22.5 Module 53 80 PYF14-ESS-B 27 61 9 COM. NO NC 4.45 4.45 4.45 83 3.2 75 4.1 6.3 6.4 22.5 COIL 29 55 82 General-purpose Relay MY 13 Socket PY08/PY08-Y1 Dimensions (See note) Terminal arrangement/ Internal connections (bottom view) Mounting holes Eight, 3 x 1.2 elliptical holes 25.5 max. 29.5 max. 20 max. 42 max. 24 max. Note: The PY08-Y1 includes sections indicated by dotted lines. PY08QN/ PY08QN-Y1 (See note) 29.5 max. 22 max. 41.5 max. 24 max. 42 max. Note: The PY08QN-Y1 includes sections indicated by dotted lines. PY08-02 25.5 max. 29.5 max. 22 max. Eight, 1.3-dia. holes 16.5 max. PY14/PY14-Y1 (See note) Fourteen, 3 x 1.2 elliptical holes 25.5 max. 29.5 max. 20 max. 42 max. 24 max. Note: The PY14-Y1 includes sections indicated by dotted lines. PY14QN/ PY14QN-Y1 (See note) 29.5 max. 41.5 max. 42 max. 22 max. 24 max. Note: The PY14QN-Y1 includes sections indicated by dotted lines. PY14-02 25.5 max. 29.5 max. 22 max. 16.5 max. Note: Use a panel with plate thickness of 1 to 2 mm for mounting the Sockets. 14 General-purpose Relay MY Fourteen, 1.3-dia. holes Hold-down Clips PYC-A1 (2 pcs per set) For sockets PYF14-ESN-B/-ESS-B PYC-E1 (2 pcs per set) 36.3 36.3 Model Description PYC-0 Metal spring clip (Used with Relay only) PYC 35-B Plastic holding clip (Used with Relay only) PYC TR1 5.75 4.5 4.50.1 1.2 4.5 4.25 PYC-P Thermoplastic writeable label Note: For total dimensions with plastic clip please refer to drawings of the sockets. PYC-P2 5 10 29 max. 28 3.3 38.5 Mounting Plates for Back-connecting Sockets PYP-1 PYP-36 Two, 3.4-dia. holes 72 elliptical holes t=1.6 PYP-18 72 elliptical holes DIN-rails and Accessories Supporting DIN-rails PFP-50N/PFP-100N 7.30.15 4.5 350.3 270.15 1 15 25 10 25 25 1000 (500) * 10 25 15 (5) Note: The figure in the parentheses is for PFP-50N. General-purpose Relay MY 15 PFP-100N2 16 4.5 350.3 27 25 15 10 25 10 25 25 1000 15 24 1 29.2 1.5 End Plate PFP-M 10 6.2 M4 x 8 pan head screw 1.8 1 50 1.8 35.5 35.3 11.5 1.3 10 M4 spring washer 4.8 Spacer PFP-S 16 12 5 34.8 44.3 16.5 Precautions Refer to General Precautions on page 11 of the General-purpose Relays and Power Relays Group Catalog (X034). Connections Mounting Do not reverse polarity when connecting DC-operated Relays with built-in diodes or indicators or high-sensitivity DC-operated Relays. * Whenever possible, mount Relays so that it is not subject to vibration or shock in the same direction as that of contact movement. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. J03E-EN-03 In the interest of product improvement, specifications are subject to change without notice. OMRON EUROPE B.V. Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands Phone: +31 23 568 13 00 Fax: +31 23 568 13 88 industrial.omron.eu 16