SOLID STATE RELAYS 45mm DIN-RAIL SSR FEATURES: DIN-Rail or Panel Mount. Compact Size. LED Indicator. AC or DC Control. Zero AC or Random turn-on models. 35 and 45 Amp Outputs. 4 kV Optical Isolation. CE Compliant Per EN60950 UL, cUL Recognized E79183 45.00 (1.772) 3.20 (0.126) 35.70 (1.406) 12.20 (0.480) CURRENT LIMITER 1 VISIBLE LED 4 5.00 (0.197) 3 AC 45mm THREE PHASE 2 9.00 (0.354) INPUT 4-32 VDC + 4 AC INPUT EQUIVALENT CIRCUIT CURRENT LIMITER OUTPUT 35 AMPS 48 TO 530 VAC 80.00 (3.150) 2 88.00 (3.858) 84130111 SOLID STATE RELAY 87.70 (3.453) PROTECTION OVER VOLTAGE PROTECTION SNUBBER GORDOS 1 3 9.30 (0.366) 1 VISIBLE LED 2 102.80 [4.047] SNUBBER OVER VOLTAGE PROTECTION 6.80 [0.268] PROTECTION 4 3 DC 45mm THREE PHASE RANDOM DC INPUT EQUIVALENT CIRCUIT Products and specifications subject to change without notice. Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1-6 SOLID STATE RELAYS INPUT SPECIFICATIONS: Model Number Parameter 84130111 84130113 84130112 84130114 84130110 84130115 Control Voltage Drop Out Voltage Maximum Input Current (1) Maximum Turn-On Time Maximum Turn-Off Time Type Wire Size 4-32 VDC 1.0 VDC 10 8.33 8.33 Zero Crossing .020-.078 4-32 VDC 1.0 VDC 10 0.1 8.33 Random Turn-on .020-.078 90-280 VAC 10 VAC 6 20 30 Zero Crossing .020-.078 1 Units mA ms ms OUTPUT SPECIFICATIONS: Model Number 84130110 84130111 84130112 84130113 84130114 84130115 48-530 1200 .25 500 100 35 750 145 1.6 1000 .040-.220 48-530 1200 .25 500 100 45 750 145 1.6 1000 .040-.220 Parameter Line Voltage Peak Off-State Voltage (2) Maximum Off-State Leakage (3) Static Off-State dv/dt (4) Minimum On-State Current Maximum On-State Current (5) Maximum 1-Cycle Surge (6) Maximum 1-Second Surge (7) Peak On-State Voltage Drop (8) I2t (60Hz, Half-Cycle) Wire Size Units Vrms Vpeak mArms V/Sec mArms Arms Apeak Apeak Vpeak A2 sec GENERAL SPECIFICATIONS: Parameter All Devices Operating Temperature Range Storage Temperature Range Input to Output Isolation Voltage (9) I/O to Ground Isolation Voltage (9) Capacitance (Input to Output) Line Frequency Range -20 to 80C -40 to 100C 4000 Vrms 2500 Vrms 8 pF 47 to 63 Hz Notes: (1) (2) (3) (4) (5) (6) (7) (8) (9) At maximum input voltage. Input is regulated and current limited. Do not apply continuously for over 1 minute. At maximum line voltage, Ta = 25C. Minimum dv/dt per EIA/NARM R5443, method RS397, 25C. Mounted in vertical position on DIN-Rail. Free Air. Non-repetitive 60 Hz, resistive load, Ta = 25C. Non-repetitive 50 or 60 Hz, resistive load, Ta = 25C. At maximum rated current. Limited to 1 mA for 1 second, Ta = 25C. Products and specifications subject to change without notice. Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1-7