Lucas Control Systems Genesis Sensors TITAN Series Low Cost, High Reliability Silicon Pressure Transducer The Genesis TITAN transducer was developed to meet the most demanding industrial pressure sensing applications while maintaining the lowest possible cost. The TITAN's modular building block approach allows for a large number of possible pressure configurations, while maintaining excellent specifications over a wide temperature range of operation. The heart of this building block approach is the custom ASIC, designed specifically for the pressure transducer industry. Utilizing this ASIC allows for field interchangeability, without recalibration of the users' system. Features The TITAN Series is offered in pressure ranges from 15 psi through 3,000 psi, with four different electrical outputs: 0.5 to 4.5 V (ratiometric); four wire 0 to 5 V; four wire 0 to 10 V; and two wire 4 to 20 mA. Two types of housing, plastic and stainless steel, are also available. All of the TITAN Series have a non-linearity, hysteresis, and nonrepeatability specification of <0.25% FSO, over the temperature range of -25 to 85C. Outputs available: 0.5-4.5 VDC; 4-20 mA; 0-5 VDC; 0-10 VDC Low-cost, modular design based on ASIC technology Highly interchangeable Plastic and stainless steel housings; IP65/ NEMA 4X protection Available in ranges from 15 psi to 3000 psi (1 to 205 bar) Compensated temperature range from -13F to 185F (-25C to 85C) Standard and custom options available in OEM quantities Genesis TITAN Series Low Cost, High Reliability Silicon Pressure Transducer Common Specifications (All specifications are at 77F (25C) unless otherwise noted) Pressure Ranges Absolute (psia) .............. psi: 0 to 15, 30, 100, 250 bar: 0 to 1, 2, 7, 15 Vented Gauge (psig) ..... psi: 0 to 15, 30, 100, 250 bar: 0 to 1, 2, 7, 15 Sealed Gauge (psis) ...... psi: 0 to 500,1000, 3000 bar: 0 to 35, 70, 205 Pressure References ......... Absolute, vented gauge, and sealed gauge (Vented gauge units should only breathe dry, noncorrosive gases, and must breathe through the receptacle - mating connector must have a vent hole) Pressure Limit ................... 0 to 100 psi (0 to 7 bar) 5X the rated pressure 250 to 1,000 psi (15 to 70 bar) 3X the rated pressure 3,000 psi (205 bar) 2.5X the rated pressure Burst Pressure ................... 0 to 250 psi ( 0 to 15 bar) 10X the rated pressure 500 to 3,000 psi (35 to 205 bar) 10,000 psi Media ................................. Liquids or gases compatible with 316L stainless steel. Static Error Band Combined Nonlinearity, Hysteresis, and Nonrepeatability .... 0.25% F.R.O. BSL max. Temperature Ranges Compensated ................. -13 to 185F (-25 to 85C) Operating Media ........... -40 to 255F (-40 to 125C) Operating Electronic Unit -40 to 212F (-40 to 100C) Storage ........................... -58 to 212F (-50 to 100C) Humidity ............................ 95% R.H., noncondensing on all vented gauge units and 100% R.H. condensing on absolute and sealed gauge units. Vibration ............................ 20g Mil-Std-810C, Procedure 514.2, Figure 514.2-2, Curve L. Shock ................................. 50g, 11 msec half sine shock per mil standard 202F, method 213B, condition A Insulation Resistance ....... 500 Mohms @ 100 VDC per Mil-Std 202F,m Method 302, condition A. Long Term Drift ................ 0.1% F.R.O./Year Typ. Response Time .................. <1 msec @ 25C 3.6 Hz/C Genesis TITANSeries Pressure Ranges: 0-15 to 3,000 psi (1 to 205 bar) Specifications By Model Model Numbers GT 3 Output @ 77F (25C) F.R.O. Input Voltage (VDC) 0.5 - 4.5 VDC 5 0.25 (no load) Output Impedance (Ohms) 8 Output Current Limit (mA) Typ. 27 Zero Offset (% F.R.O.) 0.5 V 0.5% Max. Combined Thermal Zero & Sensitivity Error (%F.R.O.)* 1.5% Max. GT 6 GT 7 GT 8 0 to 5 VDC 10 to 30, 5 mA (no load) 5 50 0 V 0.25% Max. 0-10 V 13-30 4 to 20mA 10 to 30 5 50 0 V 0.25% Max. 1 Meg (min) 25 4 mA 0.25% Max. 1.5% Max. 1.5% Max. 1.5% Max. *-25C to 85C Wiring GT3 Excitation (+) RED Output (+) GRN Output Voltage Monitor V +5 VDC Power Supply Output (-) WHT Excitation (-) BLK TITAN Ratiometric Output voltage range: 0.5-4.5VDC (4-wire cable output version) GT6 & GT7 Excitation (+) RED Output Voltage Monitor Output (+) GRN V 10-30 VDC (13-30) VDC Power Supply Output (-) WHT Excitation (-) BLK TITAN Voltage Output voltage range: 0-5V (0-10V) (4-wire cable output version) GT8 Excitation (+) RED Output Voltage Monitor V +10 -30 VDC Power Supply Excitation (-) BLK TITAN 4-20mA Output (2-wire cable output version) Internet: www.schaevitz.com North America Tel: 800/745-8008 Fax Back System: 916/431-6541 Europe Tel: (44 1753) 537622 Genesis TITAN Series Low Cost, High Reliability Pressure Ranges: 0-15 to 3,000 psi (1 to 205 bar) Silicon Pressure Transducer Dimensions in (mm) 0.75 (19.1) 3.06 (77.7) O0.94 (23.8) GTx1 Plastic Housing with Cable Models* 2.93 (74.4) 0.88 (22.2) O0.81 (20.6) GTx2 Stainlees Steel Housing with Cable Models* * Note: All cable versions supplied with 1 meter of cable. How to Order Specify by input/output, cable/connector, pressure port, pressure range, and unit of measure. Cable/Connector Model Number Code: GT 000 7 Input/Output 3- 0.5 to 4.5 V output (5 VDC supply) 6 - 0 to 5 V output (10-30 VDC supply) 7 - 0 to 10 V output (13-30 VDC supply) 8 - 4 to 20 mA output (10-30 VDC supply) Unit P: psi B: bar Pressure Reference A: Absolute SG: Sealed gauge VG: Vented gauge Connection/Housing 1 - Cable/Plastic housing 2 - Cable/Stainless steel housing 3 - Connector/Plastic housing Pressure Port 5 - 1/4 inch 18 NPT male 7 - 7/16 inch 20 UNF female** SAE-4 O-ring boss (MS16142-4) **Other fittings available upon request; contact factory Pressure Range (Enter desired pressure value without units) Psi 15; 30; 100; 250; 500; 1000; 3000 Bar 1; 2; 7; 15; 35; 70; 205 Internet: www.schaevitz.com North America Tel: 800/745-8008 Fax Back System: 916/431-6541 Europe Tel: (44 1753) 537622