TITAN Series
Low Cost, High Reliability Silicon Pressure Transducer
L u c a s C o n t r o l S y s t e m s
Genesis Sensors
The Genesis TITAN transducer was developed to meet the
most demanding industrial pressure sensing applications
while maintaining the lowest possible cost. The TITAN’s
modular building block approach allows for a large
number of possible pressure configurations, while
maintaining excellent specifications over a wide
temperature range of operation. The heart of this building
block approach is the custom ASIC, designed specifically
for the pressure transducer industry. Utilizing this ASIC
allows for field interchangeability, without recalibration of
the users’ system.
The TITAN Series is offered in pressure ranges from 15 psi
through 3,000 psi, with four different electrical outputs:
0.5 to 4.5 V (ratiometric); four wire 0 to 5 V; four wire 0 to
10 V; and two wire 4 to 20 mA. Two types of housing,
plastic and stainless steel, are also available. All of the
TITAN Series have a non-linearity, hysteresis, and non-
repeatability specification of <0.25% FSO, over the
temperature range of -25° to 85°C.
Features
Low-cost, modular design based on ASIC
technology
Highly interchangeable
Plastic and stainless steel housings; IP65/
NEMA 4X protection
Available in ranges from 15 psi to 3000 psi
(1 to 205 bar)
Outputs available: 0.5-4.5 VDC; 4-20 mA;
0-5 VDC; 0-10 VDC
Compensated temperature range from -13°F to
185°F (-25°C to 85°C)
Standard and custom options available in
OEM quantities
Low Cost, High Reliability Silicon Pressure Transducer
Genesis TITAN Series
Common Specifications (All specifications are at 77°F (25°C) unless otherwise noted)
Pressure Ranges
Absolute (psia) .............. psi: 0 to 15, 30, 100, 250 bar: 0 to 1, 2, 7, 15
Vented Gauge (psig) ..... psi: 0 to 15, 30, 100, 250 bar: 0 to 1, 2, 7, 15
Sealed Gauge (psis) ...... psi: 0 to 500,1000, 3000 bar: 0 to 35, 70, 205
Pressure References ......... Absolute, vented gauge, and sealed gauge (Vented gauge units should only breathe dry, non-
corrosive gases, and must breathe through the receptacle – mating connector must have a vent
hole)
Pressure Limit ................... 0 to 100 psi (0 to 7 bar) 5X the rated pressure
250 to 1,000 psi (15 to 70 bar) 3X the rated pressure
3,000 psi (205 bar) 2.5X the rated pressure
Burst Pressure ................... 0 to 250 psi ( 0 to 15 bar) 10X the rated pressure
500 to 3,000 psi (35 to 205 bar) 10,000 psi
Media ................................. Liquids or gases compatible with 316L stainless steel.
Static Error Band
Combined Nonlinearity, Hysteresis,
and Nonrepeatability .... ±0.25% F.R.O. BSL max.
Temperature Ranges
Compensated ................. -13° to 185°F (-25° to 85°C)
Operating Media ........... -40° to 255°F (-40° to 125°C)
Operating Electronic Unit -40° to 212°F (-40° to 100°C)
Storage ........................... -58° to 212°F (-50° to 100°C)
Humidity............................ 95% R.H., noncondensing on all vented gauge units and 100% R.H. condensing on absolute
and sealed gauge units.
Vibration............................ 20g Mil-Std-810C, Procedure 514.2, Figure 514.2-2, Curve L.
Shock ................................. 50g, 11 msec half sine shock per mil standard 202F, method 213B, condition A
Insulation Resistance ....... 500 Mohms @ 100 VDC per Mil-Std 202F,m Method 302, condition A.
Long Term Drift ................ 0.1% F.R.O./Year Typ.
Response Time .................. <1 msec @ 25°C ± 3.6 Hz/°C
Wiring
Excitation (+)
Excitation (
-
)
Output Voltage Monitor
+5 VDC
Power Supply
RED
BLK
TITAN Ratiometric Output voltage
range: 0.5-4.5VDC
(4-wire cable output version)
Output (+)
Output (
-
)
V
GRN
WHT
Excitation (+)
Excitation (
-
)
Output Voltage Monitor
10-30 VDC
(13-30) VDC
Power Supply
RED
BLK
TITAN Voltage Output voltage
range: 0-5V (0-10V)
(4-wire cable output version)
Output (+)
Output (
-
)
V
GRN
WHT
Excitation (+)
Excitation (
-
)
Output Voltage Monitor
+10-30 VDC
Power Supply
V
RED
BLK
TITAN 4-20mA Output
(2-wire cable output version)
GT3
GT6 & GT7
GT8
Specifications By Model
Model Numbers GT 3 GT 6 GT 7 GT 8
Output @ 77°F (25°C) F.R.O. 0.5 - 4.5 VDC 0 to 5 VDC 0-10 V 4 to 20mA
Input Voltage (VDC) 5± 0.25 10 to 30, 5 mA 13-30 10 to 30
(no load) (no load)
Output Impedance (Ohms) 8551 Meg (min)
Output Current Limit (mA) Typ. 27 50 50 25
Zero Offset (% F.R.O.) 0.5 V ±0.5% Max. 0 V ±0.25% Max. 0 V ±0.25% Max.
4 mA ±0.25% Max.
Combined Thermal Zero
& Sensitivity Error (%F.R.O.)* 1.5% Max. 1.5% Max. 1.5% Max. 1.5% Max.
*-25°C to 85°C
Internet: www.schaevitz.com North America Tel: 800/745-8008
Fax Back System: 916/431-6541 Europe Tel: (44 1753) 537622
Genesis TITANSeries
Pressure Ranges: 0-15 to 3,000 psi
(1 to 205 bar)
Low Cost, High Reliability
Pressure Ranges: 0-15 to 3,000 psi
(1 to 205 bar)
Dimensions in (mm)
GTx2 Stainlees Steel Housing with Cable Models*
GTx1 Plastic Housing with Cable Models*
Cable/Connector Model Number Code: GT 000 7
Input/Output
3– 0.5 to 4.5 V output (5 VDC supply)
6 – 0 to 5 V output (10-30 VDC supply)
7 – 0 to 10 V output (13-30 VDC supply)
8 – 4 to 20 mA output (10-30 VDC supply)
Pressure Range
(Enter desired pressure value without units)
Psi 15; 30; 100; 250; 500; 1000; 3000
Bar 1; 2; 7; 15; 35; 70; 205
Pressure Port
5 – 1/4 inch 18 NPT male
7 – 7/16 inch 20 UNF female**
SAE-4 O-ring boss (MS16142-4)
Connection/Housing
1 – Cable/Plastic housing
2 – Cable/Stainless steel housing
3 – Connector/Plastic housing
Pressure Reference
A: Absolute
SG: Sealed gauge
VG: Vented gauge
Unit
P: psi
B: bar
How to Order
Specify by input/output, cable/connector, pressure port,
pressure range, and unit of measure.
2.93
(74.4)
Ø0.81
(20.6)
0.88
(22.2)
3.06
(77.7)
Ø0.94
(23.8)
0.75
(19.1)
Internet: www.schaevitz.com North America Tel: 800/745-8008
Fax Back System: 916/431-6541 Europe Tel: (44 1753) 537622
Silicon Pressure Transducer
Genesis TITAN Series
**Other fittings available upon request; contact factory
* Note: All cable versions supplied with 1 meter of cable.