S
S
S
E
A
L
E
D
S
E
A
L
E
D
85
Metri-Pack Series
Sealed System Application Information
*The test data are based on single circuits in free space and were generated using a “Lumped Resistance”
model. This model does not account for all of the variables that would be present in an actual application.
For actual product performance, contact your regional support representative at the number listed below.
280
280
CABLE RANGE (
mm
2): ....... 0.35-5.0
CURRENT RANGE (AMPS): ........ 0-30
TEMP RANGE OC: .......... -40 to 125
RESISTANCE: ...... <10m@20mV
VOLTAGE DROP: ...... <3.0mV/amp
CENTERLINE SPACING (
mm
): ....... 7.7
BLADE WIDTH (
mm
): ................. 2.8
Cable Seal
Male Connector
TPA
(Terminal Position
Assurance)
Male Terminal
280 MALE TERMINALS SEALED
Part # Cable Range (mm
2
) Material Plating
12048254 5.0 Tin Brass Tin
12129497 3.0-2.0 Tin Brass Tin
12048159 1.0-0.80 Tin Brass Tin
12124977 0.50-0.35 Tin Brass Tin
280 METRI-PACK CAVITY PLUG*
Part # Cavity Inside Diameter Material Color
12010300 6.7mm Silicone Green
*Cavity plugs seal unused female and male cavities.
280 MALE CONNECTORS SEALED
# Cavities Connector Color Material TPA
1 12065171 Black PA66 HS IM 12065249
2 15300002 Black PA66 HS IM 15300014
2 12059450 Black PA66 HS IM 12065279
3 15300003 Black PA66 HS IM 15300015
4 12129600 Dk. Gray PBT 30% GF 12092733
5 12186400 Gray PBT 30% GF 12084673
7 12110753 Black PA66 HS IM 12110754
15 12161187 Black PA66 HS IM 12110782
TEMPERATURE RISE ABOVE
AMBIENT (25
o
C) VS CURRENT*
C
URRENT
(A
MPS
)
T
EMPERATURE
R
ISE
(
O
C)
0 10203040 50
5.0
100
80
60
40
20
0
2.0
TEMPERATURE DERATING CURVES*
A
MBIENT
T
EMPERATURE
(
O
C)
M
AXIMUM
C
URRENT
(A
MPS
)
25 50 75 100 125␣
5.0
50
40
30
20
10
0
3.0
0.50
280 SERIES TERMINALS – Tin Plated
0.80
1.0
2.0
3.0
1.0
0.80
0.50
SECTION NOTES:
Contact your regional support representative at the number listed below.
Due to rigid tolerances of connector cavities, it is critical to
meet all crimp dimensions as specified.
Female Connections for device applications, see page 92.
http://delphi.com/products/connect