ICS544-01
CLOCK DIVIDER CLOCK DIVIDER
IDT®
CLOCK DIVIDER 3
ICS544-01 REV B 051810
PCB Layout Recommendations
For optimum device performance and lowest output
phase noise, the following guidelines should be
observed.
1) The 0.01µF decoupling capacitor should be mounted
on the component side of the board as close to the VDD
pin as possible. No vias should be used between
decoupling capacitor and VDD pin. The PCB trace to
VDD pin should be kept as short as possible, as should
the PCB trace to the ground via. Distance of the ferrite
bead and bulk decoupling from the device is less
critical.
2) To minimize EMI, the 33Ω series termination resistor
(if needed) should be placed close to the clock output.
3) An optimum layout is one with all components on the
same side of the board, minimizing vias through other
signal layers (the ferrite bead and bulk decoupling
capacitor can be mounted on the back). Other signal
traces should be routed away from the ICS544-01. This
includes signal traces just underneath the device, or on
layers adjacent to the ground plane layer used by the
device.
Absolute Maximum Ratings
Stresses above the ratings listed below can cause permanent damage to the ICS544-01. These ratings,
which are standard values for IDT commercially rated parts, are stress ratings only. Functional operation of
the device at these or any other conditions above those indicated in the operational sections of the
specifications is not implied. Exposure to absolute maximum rating conditions for extended periods can
affect product reliability. Electrical parameters are guaranteed only over the recommended operating
temperature range.
Recommended Operation Conditions
Item Rating
Supply Voltage, VDD 7 V
All Inputs and Outputs -0.5 V to VDD+0.5 V
Ambient Operating Temperature (commercial) 0 to +70°C
Ambient Operating Temperature (industrial) -40 to +85°C
Storage Temperature -65 to +150°C
Junction Temperature 125°C
Soldering Temperature 260°C
Parameter Min. Typ. Max. Units
Ambient Operating Temperature (commercial) 0 +70 °C
Ambient Operating Temperature (industrial) -40 +85 °C
Power Supply Voltage (measured in respect to GND) 2.25 3.6 V