DIN Rail Mount Datasheet DR22 Series AC Output DIN Rail Mount SSRs * Output ratings up to 35 Amps at 600 VAC * Built-in overvoltage protection * Relay or Contactor configuration * Integral heat sink eliminates the need for complex thermal calculations * DBC substrate for superior thermal performance * "Elevator" screw option to allow the use of ring or lug type terminals * IP20 touch-safe housing * AC or DC control * C-UL-US and TUV approved PRODUCT SELECTION Control Voltage 90-280 VAC/VDC 4-32 VDC 20A 30A 35A DR2260A20x DR2260D20x DR2260A30x DR2260D30x DR2260A35x DR2260D35x AVAILABLE OPTIONS Series DR22 Operating Voltage 60: 48-600 VAC 60 A Rated Load Current 20: 20 Amps 30: 30 Amps 35: 35 Amps [High I2t] U V 20 Control Voltage (1) A: 90-280 VAC/VDC D: 4-32 VDC Switching Type Blank: Zero Voltage Turn-On R: Instantaneous Turn-On (Motor Rating Certified) R J Terminal Layout Input Connector U: Relay Configuration Blank: Screw Terminal V: Contactor Configuration J: Spring Terminal (std. screw) (V and W suffixes only) W: Contactor Configuration (elevator screw) Required for valid part number For options only and not required for valid part number OUTPUT SPECIFICATIONS (2) Description Operating Voltage (47-440Hz) [VRMS] Transient Overvoltage [Vpk] (3) Maximum Off-State Leakage Current @ Rated Voltage [mARMS] Minimum Off-State dV/dt @ Maximum Rated Voltage [V/sec] Load Current, General Use UL508/LC A IEC62314 @ 40C [ARMS] Load Current, Motor Starting UL508 FLA/LC B IEC62314 @ 40C [ARMS] Minimum Load Current [mARMS] Maximum 1 Cycle Surge Current (50/60Hz) [Apk] Maximum On-State Voltage Drop @ Rated Current [Vpk] Maximum 1/2 Cycle I t for Fusing (50/60Hz) [A sec] Minimum Power Factor (at Maximum Load) (4) Motor Rating UL 508/IEC62314 [HP (kW)]: 120 VAC Motor Rating UL 508/IEC62314 [HP (kW)]: 240 VAC Motor Rating UL 508/IEC62314 [HP (kW)]: 480 VAC 20A 30A 35A 48-600 1200 1 500 20 8.5/4.8 100 286/300 1.35 409/375 0.5 0.5 (0.37) 1.5 (1.1) 3 (2.24) 48-600 1200 1 500 30 14/7.6 100 716/750 1.35 2563/2343 0.5 1 (0.74) 3 (2.2) 5 (3.7) 48-600 1200 1 500 35 26/14 150 1290/1350 1.3 8320/7593 0.5 2 (1.5) 5 (3.73) 10 (7.4) INPUT SPECIFICATIONS (2) Description DR2260Dxxx DR2260Axxx Control Voltage Range Maximum Reverse Voltage Minimum Turn-On Voltage Must Turn-Off Voltage Minimum Input Current (for on-state) Maximum Input Current Nominal Input Impedance Maximum Turn-On Time [msec] Maximum Turn-Off Time [msec] 4-32 VDC (5) -32 VDC 4 VDC 1 VDC 10 mA 15 mA Current Limited 1/2 Cycle (7) 1/2 Cycle 90-280 VAC/VDC (6) 90 VAC/VDC 5 VAC/VDC 6 mA 10 mA Current Limited 20 30 Do not forget to visit us at: www.crydom.com Copyright (c) 2018 Crydom Inc. Specifications subject to change without notice. DIN Rail Mount Datasheet GENERAL SPECIFICATIONS (2) Description Parameters Dielectric Strength, Input to Output (50/60Hz) Dielectric Strength, Input/Output to Case (50/60Hz) Minimum Insulation Resistance (@ 500 VDC) Maximum Capacitance, Input/Output Ambient Operating Temperature Range (8) Ambient Storage Temperature Range Short Circuit Current Rating (9) Weight (typical) Housing Material Heat Sink Material Din Rail Clip Material Hardware Finish Input Terminal Screw Torque Range (lb-in/Nm) Load Terminal Screw Torque Range (lb-in/Nm) Humidity LED Input Status Indicator 4000 VRMS 4000 VRMS 109 Ohms 8 pF -40 to 80 C -40 to 100 C 100kA Option "U" 10.5 oz (298 g), Option "V","W" 10.6 oz (301 g) UL94 V-0 Aluminum Zink Plated Steel Nickel Plating Option "U" 13-15/1.5-1.7, Option "V","W" 5/0.5 (10) Option "U" 13-15/1.5-1.7, Option "V","W" 18-20/2-2.2 95% non-condensing Green INPUT CURRENT INFORMATION 90-280 VAC/VDC Input 7 12 6 Input Current (mA) Input Current (mA) 4-32 VDC Input 14 10 8 6 4 2 0 5 4 3 2 1 0 5 10 15 20 25 30 35 0 0 40 80 120 160 200 240 280 Input Voltage (VAC/VDC) Input Voltage (VDC) SURGE CURRENT INFORMATION DR2260x30x Surge Current (Amp) AC Peak Surge Current (Amp) AC Peak DR2260x20x 300 250 200 150 100 50 0 0.01 0.1 1 Surge Current (Amp) AC Peak DR2260x35x 1200 1000 800 Single Pulse (11) 600 400 200 0.1 500 400 300 200 100 0 0.1 1 Surge Duration (sec) 1400 0.01 600 0.01 10 Surge Duration (sec) 0 700 1 10 Surge Duration (sec) Do not forget to visit us at: www.crydom.com Copyright (c) 2018 Crydom Inc. Specifications subject to change without notice. 10 DIN Rail Mount Datasheet THERMAL DERATE INFORMATION (8) DR2260x20x Single unit (12) DR2260x30x Single unit (12) Multiple units 15 10 5 0 20 30 40 50 60 Ambient Temperature (C) 70 30 35 25 30 20 15 10 5 0 80 Single unit (12) Load Current (Amps) Load Current (Amps) Load Current (Amps) 20 DR2260x35x Multiple units 20 30 40 50 60 Ambient Temperature (C) 70 EQUIVALENT CIRCUIT BLOCK DIAGRAMS/WIRING DIAGRAM DC Control +3/A1 OUTPUT DC V - 1/L1 INPUT + Trigger Circuit 2/T1 -4/A2 Current Limiter Load A V AC B Load Load can be wired in position A or B AC/DC Control Current Limiter +3/A1 AC/DC Converter OUTPUT V INPUT -/ Load A +/ AC/DC 1/L1 Trigger Circuit -4/A2 2/T1 V AC B Load Load can be wired in position A or B Recommended Wire Sizes Terminal Configuration Output (13) Relay "U" suffix Input Relay "U" suffix Output Contactor "V" &"W" suffixes Wire Size (Solid / Stranded) Wire Pull-Out Strength (lb)[N] 2 x 18 AWG (1 mm2) Stranded 20 [88] 2 x 10 AWG (6 mm2) Stranded 60 [266] 2 x 18 AWG (1 mm2) Stranded 20 [88] 2 x 12 AWG (4 mm2) Stranded 40 [177] 2 x 20 AWG (0.75 mm2) [minimum] 25 [111] 2 x 10 AWG (6 mm2) 80 [355] 2 x 8 AWG (10 mm2) [maximum] 90 [400] 30 AWG (0.05 mm ) [minimum] Input Screw 12 AWG (3.3 mm2) [maximum] Contactor "V" &"W" 26 AWG (0.13 mm2) [minimum] suffixes Spring 12 AWG (3.3 mm2) [maximum] 2 4.5 [20] 30 [133] 4 [18] 30 [133] Do not forget to visit us at: www.crydom.com Copyright (c) 2018 Crydom Inc. Specifications subject to change without notice. 80 Multiple units 25 20 15 10 5 0 20 30 40 50 60 Ambient Temperature (C) 70 80 DIN Rail Mount Datasheet MECHANICAL SPECIFICATIONS Tolerances: 0.02 in / 0.5 mm All dimensions are in: inches [millimeters] Contactor Configuration 1.87 [47.5] Input Connector 1/L1 2.85 [72.3] +3/A1 1.88 [47.8] -4/A2 3.62 [91.9] 3.54 [90] Screw Terminal Spring Terminal 2/T1 1.19 [30.2] 0.89 [22.5] 4.59 [116.5] Protective Earth Connection Relay Configuration 0.39 [9.9] +3/A1 INPUT -4/A2 3.00 [76.2] 3.67 [93.2] 1.88 [47.8] 1/L1 OUTPUT 3.54 [90] Protective Earth (PE) screw type recommended is 10-32 UNC standard not provided with SSR. Through the use of a DIN rail ground (protective conductor) terminal block, the DIN rail itself can be used as the grounding bus bar. In this case, the zinc plated steel material used for the DIN rail clip of DR22 models, permits a secure path to ground and avoid the need of a further PE connection. 2/T1 1.19 [30.2] 0.89 [22.5] 10-32 Thread 4.59 [116.5] Elevator Screw (Suffix `W') TABLE 1. Compatible Terminals W D Terminals W D Fork Lug Ring Lug Width [W] in (mm) 0.45 (11.4) 0.45 (11.4) Stud Size Dia [D] (in) #8 (0.168) #8 (0.168) Crydom Part No. Wire Size AWG Do not forget to visit us at: www.crydom.com Copper Lug Copper Lug TRM0 TRM6 6-0 14-6 Copyright (c) 2018 Crydom Inc. Specifications subject to change without notice. The Elevator Screw option allows the screw and clamp to be raised out of the mating threads completely. This provides for the insertion and use of a ring or lug type wire terminal. Refer to TABLE 1 for Compatible Terminals. DIN Rail Mount Datasheet ACCESSORIES Recommended Accessories New Accessories! Connectors Part number: CP201, CP202 Connectors ID Marker Lug Terminal CP201 CNLB TRM0 CP202 CNLN TRM6 Pluggable input connectors, 2 position, with screw terminals (CP201) or spring type terminals (CP202). Compatible with Contactor Configuration NOVA22 SSRs. Lug Terminal CNL2 Part number: TRM0 Copper wire lug for AWG 6 (13.3 mm) to AWG 0 (53.5 mm) wire size. For use with "Elevator" screw option ("W" suffix) NOVA22 SSRs. AGENCY APPROVALS, CONFORMANCES AND EMC (14) E116949 E116949 Certification in accordance with: United States Standard for Industrial Control Equipment - UL 508 and Canadian Standard Association for Industrial Control Equipment - C22.2 No. 14. TUV Certified in accordance to EN62314 Vibration Resistance: IEC 60068-2-6: Amplitude Range 10-500 Hz, Displacement 0.75mm Shock Resistance: IEC 60068-2-27: Peak Acceleration 50g, Duration11ms. Electromagnetic Compatibility Generic Standard IEC 61000-6-2 Immunity for Industrial Environments Inmunity Tests Test Specification Level Performance Electrostatic Discharge 8kV air discharge Criterion A IEC 61000-4-2 6kV contact discharge Criterion A Fast transients (burst) Output IEC 61000-4-4 Input Surge IEC 61000-4-5 Output 2kV, 5kHz, 100kHz Criterion B 1kV, 5kHz, 100kHz Criterion B 1kV Line to Line Criterion B 2kV Line to Earth Criterion B AC Input 1kV Line to Line Criterion A Option Criterion A 2kV Line to Earth Do not forget to visit us at: www.crydom.com Copyright (c) 2018 Crydom Inc. Specifications subject to change without notice. DIN Rail Mount Datasheet GENERAL NOTES (1) Control voltage 18-52 VAC/VDC is available upon request. (2) All parameters at 25C unless otherwise specified. (3) Output will self trigger between 900-1200 Vpk, not suitable for capacitive loads. (4) High inductive loads requires nominal control voltage; AC input models only. (5) Increase minimum voltage by 1 V for operations from -20 to -40C. (6) For ambient temperatures above 40C the maximum control voltage must not exceed 250 VAC/VDC. (7) Turn-on time for Instantaneous turn-on versions is 0.1 msec. (8) AC input models operating range is -20 to 60 C. (9) When protected with the appropriate class and rated fuse. For detailed info please contact Crydom Technical Support. (10) Input torque only for contactor (V,W) with screw terminals Connector. (11) For single surge pulse Tc=25C; Tj=125C. For AC Output SSRs, AC RMS value of surge current equals the peak value divided by 2 (1.414). (12) Minimum spacing to obtain max. current is 22.5mm between adjacent units. (13) For 35 Amp Relay ("U") layout models, use Pin Terminals (L 0.410 in x O 0.102 in) to install 8 AWG wire. (14) Applicable to Relay ("U") option. Rev. 031318 ECN#20442 Do not forget to visit us at: www.crydom.com Copyright (c) 2018 Crydom Inc. Specifications subject to change without notice. DIN Rail Mount Datasheet DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH. * Disconnect all power before installing or working with this equipment. * Verify all connections and replace all covers before turning on power. Failure to follow these instructions will result in death or serious injury. RIESGO DE DESCARGA ELECTRICA O EXPLOSION. * Desconectar todos los suministros de energia a este equipo antes de trabajar con este equipo. * Verificar todas las conexiones y colocar todas las tapas antes de energizer el equipo. El incumplimiento de estas instrucciones puede provocar la muerte o lesiones serias. RISQUE DE DESCHARGE ELECTRIQUE OU EXPLOSION * Eteindre toutes les sources d'energie de cet appareil avant de travailler dessus de cet appareil * Verifier tous connections, et remettre tous couverts en olace avant de mettre sous De non-suivi de ces instructions provoquera la mort ou des lesions serieuses serieuses. GEFAHR EINES ELEKTRISCHE N SCHLAGES ODER EINER EXPLOSION. * Stellen Sie jeglichen Strom ab, der dieses Gerat versorgt, bevor Sie an dem Gerat Arbeiten durchfuhren * Vor dem Drehen auf Energie alle Anschlusse uberprufen und alle Abdeckungen ersetzen. Unterlassung dieser Anweisungen konnen zum Tode oder zu schweren Verletzungen fuhren. RISCHIO DI SCOSSA ELETTRICA O DELL'ESPLOSIONE. * Spenga tutta l'alimentazione che fornisce questa apparecchiatura prima di lavorare a questa apparecchiatura * * Verificare tutti i collegamenti e sostituire tutte le coperture prima dell'accensione L'omissione di queste istruzioni provochera la morte o lesioni serie WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE RISQUE DE DOMMAGE MATERIEL ET DE SURCHAUFFE DU BOITIER GEFAHR VON MATERIALSCHADEN UND GEHAUSEERHITZUNG * The product's side panels may be hot, allow the product to cool before touching. * Follow proper mounting instructions including torque values. * Do not allow liquids or foreign objects to enter this product. * Les panneaux lateraux du produit peuvent etre chauds. Laisser le produit refroidir avant de le toucher. * Respecter les consignes de montage, et notamment les couples de serrage. * Ne pas laisser penetrer de liquide ni de corps etrangers a l'interieur du produit. * Die Seitenwande konnen hei sein. Lassen Sie das Produkt abkuhlen, bevor Sie es beruhren. * Beachten Sie die Montageanweisungen, * Fuhren Sie keine Flussigkeiten oder Fremdkorper in das Produkt ein. Le non-respect de cette directive peut entrainer, Failure to follow these instructions can result in des lesions corporelles graves ou des serious injury, or equipment damage. dommages materiels. Die Nichtbeachtung dieser Anweisung kann Korperverletzung oder Materialschaden zur Folge haben. RIESGO DE DANOS MATERIALES Y DE SOBRECALENTAMIENTO DE LA UNIDAD RISCHIO DI DANNI MATERIALI E D'INVOLUCRO CALDO * Los paneles laterales del producto pueden estar calientes. Esperar que el producto se enfrie antes de tocarlo. * Respetar las instrucciones de montaje, y en particular los pares de apretado. * No dejar que penetren liquidos o cuerpos extranos en el producto. * I pannelli laterali dell'apparecchio possono scottare; lasciar quindi raffreddare il prodotto prima di toccarlo. * Seguire le istruzioni di montaggio corrette. * Non far entrare liquidi o oggetti estranei in questo apparecchio. Si no se respetan estas precauciones pueden producirse graves lesiones, danos materiales. La mancata osservanza di questa precauzione puo causare gravi rischi per l'incolumita personale o danni alle apparecchiature. Do not forget to visit us at: www.crydom.com Copyright (c) 2018 Crydom Inc. Specifications subject to change without notice. * * * DIN Rail Mount Datasheet ANNEX - ENVIRONMENTAL INFORMATION The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People's Republic of China Electronic Industry Standard SJ/T11364 - 2006, Marking for Control of Pollution Caused by Electronic Information Products. Part Name Toxic or hazardous Substance and Elements Lead (Pb) Mercury (Hg) Cadmium (Cd) Hexavalent Chromium (Cr (VI)) Polybrominated biphenyls (PBB) Polybrominated diphenyl ethers (PBDE) Semiconductor die Solder - SJ/T11364 - 2006, (Pb) (Hg) (Cd) (Cr (VI)) 50 Do not forget to visit us at: www.crydom.com Copyright (c) 2018 Crydom Inc. Specifications subject to change without notice. (PBB) (PBDE)