DR22 Series
AC Output DIN Rail Mount SSRs
Output ratings up to 35 Amps at 600 VAC
Built-in overvoltage protection
Relay or Contactor configuration
Integral heat sink eliminates the need for complex thermal calculations
DBC substrate for superior thermal performance
"Elevator" screw option to allow the use of ring or lug type terminals
IP20 touch-safe housing
AC or DC control
C-UL-US and TUV approved
PRODUCT SELECTION
Control Voltage 20A
90-280 VAC/VDC DR2260A20x
4-32 VDC DR2260D20x
30A
DR2260A30x
DR2260D30x
35A
DR2260A35x
DR2260D35x
AVAILABLE OPTIONS
Required for valid part number
For options only and not required for valid part number
Operating Voltage
60: 48-600 VAC
Switching Type
Blank: Zero Voltage Turn-On
R: Instantaneous Turn-On
(Motor Rating Certified)
Control Voltage (1)
A: 90-280 VAC/VDC
D: 4-32 VDC
Series
DR22 60 A R
Rated Load Current
20: 20 Amps
30: 30 Amps
35: 35 Amps [High I2t]
U
Terminal Layout
U: Relay Configuration
V: Contactor Configuration
(std. screw)
W: Contactor Configuration
(elevator screw)
Input Connector
Blank: Screw Terminal
J: Spring Terminal
(V and W suffixes only)
V
20 J
OUTPUT SPECIFICATIONS (2)
Description 30A
Operating Voltage (47-440Hz) [VRMS] 48-600
Transient Overvoltage [Vpk] (3) 1200
Maximum Off-State Leakage Current @ Rated Voltage [mARMS] 1
Minimum Off-State dV/dt @ Maximum Rated Voltage [V/μsec] 500
Load Current, General Use UL508/LC A IEC62314 @ 40°C [ARMS] 30
Minimum Load Current [mARMS] 100
Maximum 1 Cycle Surge Current (50/60Hz) [Apk] 716/750
Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.35
Maximum 1/2 Cycle I² t for Fusing (50/60Hz) [A² sec] 2563/2343
35A20A
48-600 48-600
1200 1200
1 1
500 500
20 35
Load Current, Motor Starting UL508 FLA/LC B IEC62314 @ 40°C [ARMS] 14/7.6
8.5/4.8 26/14
100 150
286/300 1290/1350
1.35 1.3
409/375 8320/7593
Minimum Power Factor (at Maximum Load) (4) 0.5
0.5 0.5
Motor Rating UL 508/IEC62314 [HP (kW)]: 120 VAC 1 (0.74)
0.5 (0.37) 2 (1.5)
Motor Rating UL 508/IEC62314 [HP (kW)]: 240 VAC 3 (2.2)
1.5 (1.1) 5 (3.73)
Motor Rating UL 508/IEC62314 [HP (kW)]: 480 VAC 5 (3.7)
3 (2.24) 10 (7.4)
INPUT SPECIFICATIONS (2)
Description DR2260Axxx
Control Voltage Range 90-280 VAC/VDC
Maximum Reverse Voltage -
Minimum Turn-On Voltage 90 VAC/VDC
Must Turn-Off Voltage 5 VAC/VDC
Minimum Input Current (for on-state) 6 mA
Maximum Input Current 10 mA
Nominal Input Impedance Current Limited
Maximum Turn-On Time [msec] 20
Maximum Turn-Off Time [msec] 30
DR2260Dxxx
4-32 VDC
-32 VDC
4 VDC
1 VDC
10 mA
15 mA
Current Limited
1/2 Cycle
1/2 Cycle
(5) (6)
(7)
Datasheet
DIN Rail Mount
Do not forget to visit us at: www.crydom.com
Copyright © 2018 Crydom Inc. Specifications subject to change without notice.
GENERAL SPECIFICATIONS
(2)
ParametersDescription
Dielectric Strength, Input to Output (50/60Hz) 4000 V
RMS
Minimum Insulation Resistance (@ 500 VDC)
109 Ohms
Dielectric Strength, Input/Output to Case (50/60Hz)
4000 VRMS
Maximum Capacitance, Input/Output 8 pF
Ambient Operating Temperature Range
(8)
-40 to 80 °C
Ambient Storage Temperature Range -40 to 100 °C
Short Circuit Current Rating
(9)
100kA
Weight (typical) Option “U” 10.5 oz (298 g), Option “V”,“W” 10.6 oz (301 g)
Housing Material UL94 V-0
Heat Sink Material Aluminum
Din Rail Clip Material Zink Plated Steel
Hardware Finish Nickel Plating
Input Terminal Screw Torque Range (lb-in/Nm) Option “U” 13-15/1.5-1.7, Option “V”,“W” 5/0.5
Load Terminal Screw Torque Range (lb-in/Nm) Option “U” 13-15/1.5-1.7, Option “V”,“W” 18-20/2-2.2
Humidity 95% non-condensing
LED Input Status Indicator Green
(10)
INPUT CURRENT INFORMATION
0
2
4
6
8
10
12
14
0 5 10 15 20 25 30 35
4-32 VDC Input
Input Current (mA)
Input Voltage (VDC)
0
1
2
3
4
5
6
7
0 40 80 120 160 200 240 280
90-280 VAC/VDC Input
Input Current (mA)
Input Voltage (VAC/VDC)
SURGE CURRENT INFORMATION
Single Pulse (11)
0
50
100
150
200
250
300
0.01 0.1 1 10
Surge Current (Amp) AC Peak
Surge Duration (sec)
DR2260x20x
0
100
200
300
400
500
600
700
0.01 0.1 1 10
Surge Current (Amp) AC Peak
Surge Duration (sec)
DR2260x30x
0
200
400
600
800
1000
1200
1400
0.01 0.1 1 10
Surge Current (Amp) AC Peak
Surge Duration (sec)
DR2260x35x
Datasheet
DIN Rail Mount
Do not forget to visit us at: www.crydom.com
Copyright © 2018 Crydom Inc. Specifications subject to change without notice.
EQUIVALENT CIRCUIT BLOCK DIAGRAMS/WIRING DIAGRAM
DC Trigger
Circuit
Current
Limiter
AC
-4/A2
V
+3/A1
2/T1
1/L1
INPUT
OUTPUT
+
-V
Load
Load
A
B
Load can be wired in position A or B
AC/DC Trigger
Circuit
Current
Limiter
INPUT
AC/DC
Converter
OUTPUT
ACV
Load
Load
A
B
V
+/
-/
Load can be wired in position A or B
+3/A1
-4/A2
1/L1
2/T1
Recommended Wire Sizes
Terminal
Configuration
Wire Size
(Solid / Stranded)
Wire Pull-Out
Strength (lb)[N]
Output (13)
Relay “U” suffix
Output
Contactor
“V” &“W”
suffixes
Input
Contactor
“V” &“W”
suffixes
2 x 18 AWG (1 mm2) Stranded
2 x 10 AWG (6 mm2) Stranded
2 x 18 AWG (1 mm2) Stranded
2 x 12 AWG (4 mm2) Stranded
2 x 20 AWG (0.75 mm2) [minimum]
2 x 10 AWG (6 mm2)
2 x 8 AWG (10 mm2) [maximum]
30 AWG (0.05 mm2) [minimum]
12 AWG (3.3 mm2) [maximum]
26 AWG (0.13 mm2) [minimum]
12 AWG (3.3 mm2) [maximum]
20 [88]
60 [266]
20 [88]
40 [177]
25 [111]
80 [355]
90 [400]
4.5 [20]
30 [133]
4 [18]
30 [133]
Screw
Spring
Input
Relay “U” suffix
DC Control
AC/DC Control
THERMAL DERATE INFORMATION
0
5
10
15
20
30
35
25
20 30 40 50 60 70 80
Load Current (Amps)
Ambient Temperature (ºC)
DR2260x35x
Single unit (12) Multiple units
0
5
10
15
20
30
25
20 30 40 50 60 70 80
Load Current (Amps)
Ambient Temperature (ºC)
DR2260x30x
Single unit (12) Multiple units
0
5
10
15
20
20 30 40 50 60 70 80
Load Current (Amps)
Ambient Temperature (ºC)
DR2260x20x
Single unit (12) Multiple units
(8)
Datasheet
DIN Rail Mount
Do not forget to visit us at: www.crydom.com
Copyright © 2018 Crydom Inc. Specifications subject to change without notice.
MECHANICAL SPECIFICATIONS
Tolerances: ±0.02 in / 0.5 mm
All dimensions are in: inches [millimeters]
2.85
[72.3]
1.88
[47.8]
0.89
[22.5]
3.62
[91.9]
1.19
[30.2]
1.87
[47.5]
4.59
[116.5]
3.54
[90]
2/T1
1/L1
+3/A1 -4/A2
Contactor Configuration
Relay Configuration
INPUT
+3/A1 -4/A2
OUTPUT
1/L1 2/T1
0.39
[9.9]
1.88
[47.8]
3.67
[93.2]
3.00
[76.2]
0.89
[22.5]
1.19
[30.2]
4.59
[116.5]
3.54
[90]
Screw
Terminal
Input Connector
Spring
Terminal
TABLE 1. Compatible Terminals
Fork Lug Ring Lug Copper Lug Copper Lug
Width [W] in (mm)
Terminals
Stud Size Dia [D] (in)
Wire Size AWG
Crydom Part No.
0.45 (11.4)
#8 (0.168)
0.45 (11.4)
#8 (0.168)
TRM0
6-0
TRM6
14-6
W D
W D
Elevator Screw (Suffix ‘W’)
The Elevator Screw option allows the screw and
clamp to be raised out of the mating threads
completely. This provides for the insertion and
use of a ring or lug type wire terminal. Refer to
TABLE 1 for Compatible Terminals.
Datasheet
DIN Rail Mount
Do not forget to visit us at: www.crydom.com
Copyright © 2018 Crydom Inc. Specifications subject to change without notice.
Protective Earth Connection
Protective Earth (PE) screw type recommended is
10-32 UNC standard not provided with SSR. Through
the use of a DIN rail ground (protective conductor)
terminal block, the DIN rail itself can be used as the
grounding bus bar. In this case, the zinc plated steel
material used for the DIN rail clip of DR22 models,
permits a secure path to ground and avoid the need of
a further PE connection.
10-32
Thread
ACCESSORIES
Lug TerminalID Marker
Recommended Accessories
CNLB
CNLN
CNL2
Connectors
CP201
CP202
TRM0
TRM6
New Accessories!
Connectors
Part number: CP201, CP202
Pluggable input connectors, 2 position, with screw terminals (CP201) or
spring type terminals (CP202). Compatible with Contactor Configuration
NOVA22 SSRs.
Lug Terminal
Part number: TRM0
Copper wire lug for AWG 6 (13.3 mm²) to AWG 0 (53.5 mm²) wire size. For
use with "Elevator" screw option ("W" suffix) NOVA22 SSRs.
AGENCY APPROVALS, CONFORMANCES AND EMC
United States Standard for Industrial Control Equipment - UL 508 and
Canadian Standard Association for Industrial Control Equipment – C22.2 No. 14.
TUV Certified in accordance to EN62314
Vibration Resistance:
IEC 60068-2-6: Amplitude Range 10-500 Hz, Displacement 0.75mm
Shock Resistance:
IEC 60068-2-27: Peak Acceleration 50g, Duration11ms.
Certification in accordance with:
Electromagnetic Compatibility
Generic
Standard
Inmunity Tests Test Specification
Level
IEC 61000-6-2
Immunity for
Industrial
Environments
Electrostatic Discharge
IEC 61000-4-2
Fast transients (burst)
IEC 61000-4-4
Surge
IEC 61000-4-5
8kV air discharge
6kV contact discharge
Output 2kV, 5kHz, 100kHz
Input 1kV, 5kHz, 100kHz
1kV Line to Line
2kV Line to Earth
AC Input 1kV Line to Line
Option 2kV Line to Earth
Output
Performance
Criterion A
Criterion A
Criterion B
Criterion B
Criterion B
Criterion B
Criterion A
Criterion A
E116949 E116949
(14)
Datasheet
DIN Rail Mount
Do not forget to visit us at: www.crydom.com
Copyright © 2018 Crydom Inc. Specifications subject to change without notice.
Rev. 031318
ECN#20442
GENERAL NOTES
(1) Control voltage 18-52 VAC/VDC is available upon request.
(2) All parameters at 25°C unless otherwise specified.
(3) Output will self trigger between 900-1200 Vpk, not suitable for capacitive loads.
(4) High inductive loads requires nominal control voltage; AC input models only.
(5) Increase minimum voltage by 1 V for operations from -20 to -40°C.
(6) For ambient temperatures above 40°C the maximum control voltage must not exceed 250 VAC/VDC.
(7) Turn-on time for Instantaneous turn-on versions is 0.1 msec.
(8) AC input models operating range is -20 to 60 °C.
(9) When protected with the appropriate class and rated fuse. For detailed info please contact Crydom Technical Support.
(10) Input torque only for contactor (V,W) with screw terminals Connector.
(11) For single surge pulse Tc=25°C; Tj=125°C. For AC Output SSRs, AC RMS value of surge current equals the peak value divided by √2 (1.414).
(12) Minimum spacing to obtain max. current is 22.5mm between adjacent units.
(13) For 35 Amp Relay (”U”) layout models, use Pin Terminals (L 0.410 in x Ø 0.102 in) to install 8 AWG wire.
(14) Applicable to Relay (”U”) option.
Datasheet
DIN Rail Mount
Do not forget to visit us at: www.crydom.com
Copyright © 2018 Crydom Inc. Specifications subject to change without notice.
DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / 危险
HAZARD OF
ELECTRIC
SHOCK,
EXPLOSION,
OR ARC FLASH.
Disconnect all
power before
installing or
working with
this equipment.
Verify all
connections
and replace all
covers before
turning on
power.
Failure to follow
these
instructions will
result in death
or serious injury.
RIESGO DE
DESCARGA
ELECTRICA O
EXPLOSION.
Desconectar
todos los
suministros de
energia a este
equipo antes
de trabajar
con este equipo.
Verificar todas
las conexiones
y colocar todas
las tapas antes
de energizer
el equipo.
El
incumplimiento
de estas
instrucciones
puede provocar
la muerte o
lesiones serias.
RISQUE DE
DESCHARGE
ELECTRIQUE
OU EXPLOSION
Eteindre
toutes les
sources
d'énergie de
cet appareil
avant de
travailler
dessus de cet
appareil
Vérifier tous
connections, et
remettre tous
couverts en
olace avant de
mettre sous
De non-suivi de
ces instructions
provoquera la
mort ou des
lésions sérieuses
sérieuses.
GEFAHR EINES
ELEKTRISCHE
N SCHLAGES
ODER EINER
EXPLOSION.
Stellen Sie
jeglichen
Strom ab, der
dieses Gerät
versorgt, bevor
Sie an dem
Gerät Arbeiten
durchführen
Vor dem
Drehen auf
Energie alle
Anschlüsse
überprüfen
und alle
Abdeckungen
ersetzen.
Unterlassung
dieser
Anweisungen
können zum
Tode oder zu
schweren
Verletzungen
führen.
RISCHIO DI
SCOSSA
ELETTRICA O
DELL’ESPLOSIONE.
Spenga tutta
l'alimentazione
che fornisce
questa
apparecchiatura
prima di lavorare
a questa
apparecchiatura
Verificare tutti
i collegamenti
e sostituire
tutte le coperture
prima
dell’accensione
L'omissione di
queste istruzioni
provocherà la
morte o
lesioni serie
存在电击、
爆炸或电弧
闪烁危险
在操作此设
备之前请先
关闭电源。
若不遵守这些说明,
可能会导致严重的
人身伤害甚至死亡。
WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / 警告
RISK OF MATERIAL DAMAGE AND HOT
ENCLOSURE
The product's side panels may be hot, allow
the product to cool before touching.
Follow proper mounting instructions including
torque values.
Do not allow liquids or foreign objects to enter
this product.
Failure to follow these instructions can result in
serious injury, or equipment damage.
RISQUE DE DOMMAGE MATERIEL ET DE
SURCHAUFFE DU BOITIER
Les panneaux latéraux du produit peuvent être
chauds. Laisser le produit refroidir avant de le
toucher.
Respecter les consignes de montage, et
notamment les couples de serrage.
Ne pas laisser pénétrer de liquide ni de corps
étrangers à l'intérieur du produit.
Le non-respect de cette directive peut entraîner,
des lésions corporelles graves ou des
dommages matériels.
Die Nichtbeachtung dieser Anweisung kann
Körperverletzung oder Materialschäden
zur Folge haben.
GEFAHR VON MATERIALSCHÄDEN UND
GEHÄUSEERHITZUNG
Die Seitenwände können heiß sein. Lassen Sie
das Produkt abkühlen, bevor Sie es berühren.
Beachten Sie die Montageanweisungen,
Führen Sie keine Flüssigkeiten oder
Fremdkörper in das Produkt ein.
Si no se respetan estas precauciones pueden
producirse graves lesiones, daños materiales.
RIESGO DE DAÑOS MATERIALES Y DE
SOBRECALENTAMIENTO DE LA UNIDAD
Los paneles laterales del producto pueden
estar calientes. Esperar que el producto se
enfríe antes de tocarlo.
Respetar las instrucciones de montaje, y en
particular los pares de apretado.
No dejar que penetren líquidos o cuerpos
extraños en el producto.
La mancata osservanza di questa precauzione può
causare gravi rischi per l'incolumità personale o
danni alle apparecchiature.
RISCHIO DI DANNI MATERIALI E D'INVOLUCRO
CALDO
I pannelli laterali dell'apparecchio possono
scottare; lasciar quindi raffreddare il prodotto
prima di toccarlo.
Seguire le istruzioni di montaggio corrette.
Non far entrare liquidi o oggetti estranei in questo
apparecchio.
如不能正确执行这些操作说明,
极有可能造成严重人体伤害或者设备的损坏。
材料损坏和高温外壳的危险性
产品的一侧面板可能很热,在其冷却前请
不要触碰。
遵照正确的安装说明,包括扭矩值。
请勿让液体及其他异物进入本产品。
Datasheet
DIN Rail Mount
Do not forget to visit us at: www.crydom.com
Copyright © 2018 Crydom Inc. Specifications subject to change without notice.
ANNEX - ENVIRONMENTAL INFORMATION
The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People’s Republic of China
Electronic Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution Caused by Electronic Information Products.
Part
Name
Toxic or hazardous Substance and Elements
Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated
(Pb) (Hg) (Cd) Chromium
(Cr (VI))
biphenyls
(PBB)
diphenyl ethers
(PBDE)
Semiconductor die
Solder
附件 - 环保信息
此附件所标示的包括电子信息产品污染图标的环保信息符合中华人民共和国电子行业标准 SJ/T11364 - 2006,
电子信息产品污染控制标识要求。
有毒有害物质或元素
名称 六价铬 多溴联苯 多溴二苯醚
(Pb) (Hg) (Cd) (Cr (VI)) (PBB) (PBDE)
半导体芯片
焊接点
50
Datasheet
DIN Rail Mount
Do not forget to visit us at: www.crydom.com
Copyright © 2018 Crydom Inc. Specifications subject to change without notice.