- IT / Multimedia Equipment
EN 62368-1
IEC 62368-1
UL 62368-1
EN 60601-1
IEC 60601-1
ANSI/AAMI ES 60601-1
2 x MOPP (Means Of Patient Protection)
- Certification Documents
www.tracopower.com/overview/tim2sm
EN 60601-1-2 edition 4 (Medical Devices)
EN 55011 class B (with external filter)
EN 55032 class B (with external filter)
FCC Part 18, class B
EN 55011 class B (with external filter)
EN 55032 class B (with external filter)
FCC Part 18, class B
External filter proposal:
www.tracopower.com/overview/tim2sm
EN 60601-1-2 edition 4 (Medical Devices)
- Electrostatic Discharge
EN 61000-4-2, ±15 kV, perf. criteria A
EN 61000-4-2, ±8 kV, perf. criteria A
- RF Electromagnetic Field
EN 61000-4-3, 10 V/m, perf. criteria A
EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±1 kV, perf. criteria A
9 Vin models: KY 1000 µF // TVS SMDJ18A
12 Vin models: KY 470 µF
24 Vin models: KY 470 µF
48 Vin models: KY 220 µF
- Conducted RF Disturbances
EN 61000-4-6, 10 Vrms, perf. criteria A
EN 61000-4-8, 100 A/m, perf. criteria A
EN 61000-4-8, 1000 A/m, perf. criteria A
95% max. (non condensing)
Natural convection (20 LFM)
- Current Controlled Remote
On: open circuit
Off: 2 to 4 mA current (internal 1 kOhm resistor)
External circuit proposal:
www.tracopower.com/info/current-remote.pdf
Altitude During Operation
- Input to Output, 100 kHz, 1 V
2 µA max. (at 240 VAC / 60 Hz)
6'809'000 h (MIL-HDBK-217F, ground benign)
All specifications valid at nominal voltage, full load and +25°C after warm-up time unless otherwise stated.