USA Europe Asia
TEL: 1-760-930-4600 44-(0)1384-842-211 852-2437-9662
FAX: 1-760-930-0698 44-(0)1384-843-355 852-2402-4426 www.astec.com
ule should be installed in end-use equipment, in
compliance with the requirements of the ulti-
mate application, and is intended to be supplied
by an isolated secondary circuit. When the sup-
ply to the DC/DC power module meets all the
requirements for SELV(<60Vdc), the output is
considered to remain within SELV limits (level
3). If connected to a non-SELV power system,
double or reinforced insulation must be provid-
ed in the power supply that isolates the input
from any hazardous voltages, including the ac
mains. One Vi pin and one Vo pin are to be
grounded or both the input and output pins are
to be kept floating. Single fault testing in the
power supply must be performed in combina-
tion with the DC/DC power module to demon-
strate that the output meets the requirement for
SELV. The input pins of the module are not
operator accessible.
Note: Do not ground either of the input pins of
the module, without grounding one of the output
pins. This may allow a non-SELV voltage to
appear between the output pin and ground.
Case Grounding
Case Grounding
For proper operation of the module, the case or
baseplate of the AEH 24Vin module does not
require a connection to a chassis ground. If the
AEH module is not in a metallic enclosure in a
system, it may be advisable to directly ground
the case to reduce electric field emissions.
Leaving the case floating can help to reduce
magnetic field radiation from common mode
noise currents. If the case has to be grounded
for safety or other reasons, an inductor can be
connected to chassis at DC and AC line fre-
quencies, but be left floating at switching fre-
quencies. Under this condition, the safety
requirements are met and the emissions are
minimized.
Output Characteristic
Output Characteristic
Minimum Load Requirement
Minimum Load Requirement
There no minimum load requirement for the
AEH 24Vin series modules.
Remote Sensing
Remote Sensing
The AEH 24Vin converter can remotely sense
both lines of its output which moves the effec-
tive output voltage regulation point from the out-
put of the unit to the point of connection of the
remote sense pins. This feature automatically
adjusts the real output voltage of the AEH
24Vin in order to compensate for voltage drops
in distribution and maintain a regulated voltage
at the point of load.
When the converter is supporting loads far
away, or is used with undersized cabling, sig-
nificant voltage drop can occur at the load. The
best defense against such drops is to locate the
load close to the converter and to ensure ade-
quately sized cabling is used. When this is not
possible, the converter can compensate for a
drop of up to 0.5V, through use of the sense
leads.
When used, the + and - sense leads should be
connected from the converter to the point of
load as shown in Figure 9 using twisted pair
wire. The converter will then regulate its output
voltage at the point where the leads are con-
nected. Care should be taken not to reverse the
sense leads. If reversed, the converter will trig-
ger the OVP protection and turn off. When not
used, the +Sense lead must be connected
with +Vo directly, and -Sense with -Vo. Also
note that the output voltage and the remote
sense voltage offset must be less than the min-