DC G4010 series 12 Size: (40 x 40 x 10.3 mm) 1.57 0.02 (40 0.5) 0.41 0.02 (10.3 0.5) 1.26 0.01 (32 0.3) Construction: Bearing option: Connection: Frame: Protection: Options: STATIC PRESSURE - MM OF WATER 1.57 x 1.57 x 0.41 inches UL94V-O impeller & frame ball bearing AWG 26, UL1061 lead wires ribbed thermal tachometer output or locked rotor alarm signal S 10 L M 8 H E 6 4 2 0 0.1 0.2 0.3 0.4 AIR VOLUME Q= M3/MIN AIR FLOW 4x O0.17 0.01 (4x O4.25 0.3) .50 ) O1 38.2 O ( www.mechatronics.com Current mA Max. Static Pressure (H20) Model No. Rated Voltage V 5 12 24 M/Min. CFM MM INCH Sound Noise dbA G4010S 5/12 90 60 - 4,000 0.12 4.2 1.20 0.05 21 18 G4010L 5/12 140 100 - 5,000 0.16 5.6 2.70 0.11 24 18 240 150 - G4010M 5/12 G4010H 5/12/24 G4010E 12/24 E-mail: Sales@Mechatronics.com 400 220 160 - 350 250 Revolution RPM Air Volume Weight g 6,000 0.19 6.7 3.70 0.15 28 18 8,000 0.25 8.8 6.40 0.25 35 18 10,000 0.32 11.3 9.90 0.39 41 18 Fax: 425-222-5155 Tel: 425-222-5900 800-453-4569 07/16/14 4x O0.17 0.01 (4x O4.25 0.3)