Solid State Relay G3MC Compact, Thin-profile, Low-cost SSR with Reinforced Insulation * Small bottom surface area (approx. 80% of the conventional G3MB's), ideal for close PCB mounting. * DC input and AC output for an applicable load of 1A at 40C. * Compact, thin-profile SSR of monoblock construction with an all-in-one frame incorporates a PCB, terminals, and a heatsink. * Approved by UL and CSA. VDE certified models available. * Models with reinforced insulation are available. Ordering Information To Order: Select the part number and add the desired coil voltage rating, (e.g., G3MC-101P-DC12). Isolation Phototriac Zero-cross function Yes Built-in snubber circuit Yes Rated output load 1 A at 100 to 120 VAC (75 to 132 VAC) Rated input voltage 5 VDC Part number G3MC-101P 12 VDC 24 VDC No 5 VDC G3MC-101PL 12 VDC 24 VDC Yes 2 A at 100 to 240 VAC (75 to 264 VAC) 5 VDC G3MC-202P 12 VDC 24 VDC No 5 VDC G3MC-202PL 12 VDC 24 VDC Note: 1. All models meet UL and CSA standards. In order to obtain VDE approved versions with UL, CSA and VDE Logos, add "-VD" to the part number. Example: G3MC-101P-VD-DC12 2. 2A models are available with reinforced insulation. Add "-1" to the part number to obain 2A models with reinfored insulation. Examples: G3MC-202PL-1-DC5 G3MC-202P-VD-1-DC24 Solid State Relay G3MC 377 Specifications Ratings (Ambient temperature 25C) Input Rated voltage Operating voltage Impedance Voltage levels Must operate voltage 5 VDC 4 to 6 VDC 300 20% 4 VDC max. 12 VDC 9.6 to 14.4 VDC 800 20% 9.6 VDC max. 24 VDC 19.2 to 28.8 VDC 1.6k 20% 19.2 VDC max. Must dropout voltage 1 VDC min. Note: Each model has 5-VDC, 12-VDC, and 24-VDC input versions. Output Part number Applicable load Rated load voltage Load voltage range Load current Surge current G3MC-101P(L)(-VD) 100 to 120 VAC, 50/60 Hz 75 to 132 VAC, 50/60 Hz 0.1 to 1 A 8 A (60 Hz, 1 cycle) G3MC-202P(L)(-VD)(-1) 100 to 240 VAC, 50/60 Hz 75 to 264 VAC, 50/60 Hz 0.1 to 2 A 30 A (60 Hz, 1 cycle) Characteristics Item G3MC-101P(-VD) G3MC-101PL(-VD) Operate time 1/2 of load power source cycle + 1 ms 1 ms max. Release time 1/2 of load power source cycle + 1 ms) Output ON voltage drop 1.6 V (RMS) max. Leakage current 1 mA max. (at 100 VAC) Insulation resistance 1,000 M min. (at 500 VDC) G3MC-202P(-VD)(-1) 1/2 of load power source cycle + 1 ms G3MC-202PL(-VD)(-1) 1 ms max. 1.5 mA max. (at 200 VAC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 min (3,000 VAC, 50/60 Hz for 1 min. for G3MC-@@@-VD-1) Vibration resistance Malfunction: 10 to 55 Hz, 0.75-mm double amplitude Shock resistance Malfunction: 1,000 m/s2 (approx. 100G) Ambient temperature Operating:-30C to 80C (with no icing or condensation) Storage:-30C to 100C (with no icing or condensation) Approved standards UL File No. E64562, CSA File No. LR35535 EN60950 File No. 5925UG ("-VD(-1)" type) Ambient humidity Operating: 45% to 85% Weight Approx. 2.5g (Approx. 5g for G3MC-202P(L)-VD-1) 378 Solid State Relay G3MC Engineering Data G3MC-101P(L)(-VD) Load Current vs. Ambient Temperature Characteristics Inrush Current Resistivity One cycle, non-repetitive (Keep the inrush current to half the rated value if it occurs repeatedly.) 1.2 Peak inrush current (A) Load current (A) 1.0 0.8 0.6 0.4 0.2 0 -30 -20 0 20 40 60 80 100 Energized time (ms) Ambient temperature (C) G3MC-202P(L)(-VD)(-1) Load Current vs. Ambient Temperature Characteristics Inrush Current Resistivity One cycle, non-repetitive (Keep the inrush current to half the rated value if it occurs repeatedly.) 2.0 Peak inrush current (A) Load current (A) 2.5 1.5 1.0 0.5 0 -30 -20 0 20 25 40 60 80 Ambient temperature (C) 100 Energized time (ms) Solid State Relay G3MC 379 Dimensions Units: mm (inch) G3MC-101P(L)(-VD) PCB Dimensions (Bottom View) 4.5 max. Four, 1.0-dia. holes 24.5 max. 13.5 max. 0.8 3.5 2.54 0.25 4-1.6 4-0.7 10.16 1.2 7.62 2.54 Terminal Arrangement (Bottom View) G3MC-202P(L)(-VD)(-1) 4.5 max. 24.5 max. PCB Dimensions (Bottom View) Four, 1.0-dia. holes 20.5 max. 0.8 3.5 2.54 0.25 4-1.6 4-0.7 10.16 2.54 380 Solid State Relay G3MC 7.62 1.2 Terminal Arrangement (Bottom View) Precautions General Precautions Protective element Do not touch the terminals of the SSR while power is being supplied to the SSR. The terminals are charged with the power, and an electric shock may be received by touching the terminals. No overvoltage absorption element is built in. Therefore, if the G3MC is connected to an inductive load, be sure to connect the overvoltage absorption element. The built-in capacitor may have a residual voltage after the SSR is turned off. Be sure to discharge the residual voltage before touching the terminals of the SSR, otherwise an electric shock may be received. G3MC-@@@PL (without Zero cross function) Phototriac Load Mounting 1. Make sure that no excessive voltage or current is imposed on or flows to the input or output circuit of the SSR, otherwise the SSR may malfunction or burn. 2. Solder the terminals of the SSR properly under the required soldering conditions. The SSR may be abnormally heated and burn if power is supplied to the terminals soldered incorrectly. 3. Do not short-circuit the load of the SSR while power is supplied to the SSR. Do not short-circuit the power supply through the SSR. The SSR may be damaged, malfunction, or burn if the load or power supply is short-circuited. Protective element (MOV) Input Power supply G3MC-@@@P (with Zero cross function) Phototriac Load Protective element (MOV) Input Power supply Correct use The terminals of the SSR are highly heat-conductive. Each terminal must be soldered within 10 s at 260C or within 5 s at 350C. The SSR is of a thin-profile construction. To maintain the vibration resistance of the SSR, make sure that the space between the SSR and PCB is 0.1 mm maximum. Lifting of the PCB can be prevented by setting the hole diameter of the PCBs on both sides slightly smaller than the actual terminal dimension. Select the model without the zero-cross function when using the Unit for phase control output. The casing works as a heat sink. When mounting two or more Units closely, make sure that the Units are properly ventilated by taking ambient temperature rises into consideration. If Units are closely mounted and used in places with no ventilation, the load current of each Unit must be 1/2 of the rated load current. Complete "Terms and Conditions of Sale" for product purchase and use are on Omron's website at http://www.components.omron.com - under the "About Us" tab, in the Legal Matters section. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Solid State Relay G3MC 381 MEMO 382 Solid State Relay G3MC Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2010.1 14 OMRON Corporation Industrial Automation Company In the interest of product improvement, specifications are subject to change without notice. OMRON ELECTRONICS LLC * THE AMERICAS HEADQUARTERS * Schaumburg, IL USA * 847.843.7900 * 800.556.6766 * www.omron247.com OMRON CANADA, INC. * HEAD OFFICE Toronto, ON, Canada * 416.286.6465 * 866.986.6766 www.omron247.com OMRON ARGENTINA * SALES OFFICE Cono Sur * 54.11.4783.5300 OMRON ELETRONICA DO BRASIL LTDA * HEAD OFFICE Sao Paulo, SP, Brasil * 55.11.2101.6300 * www.omron.com.br OMRON CHILE * SALES OFFICE Santiago * 56.9.9917.3920 OMRON ELECTRONICS MEXICO SA DE CV * HEAD OFFICE Apodaca, N.L. * 52.811.156.99.10 * 001.800.556.6766 * mela@omron.com OTHER OMRON LATIN AMERICA SALES 54.11.4783.5300 Omron Europe B.V. Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. Tel: +31 (0) 23 568 13 00 Fax: +31 (0) 23 568 13 88 www.industrial.omron.eu Cat. No. J28I-E-01 06/09 Note: Specifications are subject to change. (c) 2010 Omron Electronics LLC