Solid State Relay G3MC 377
Solid State Relay
G3MC
Compact, Thin-profile, Low-cost SSR with
Reinforced Insulation
Small bottom surface area (approx. 80% of the
conventional G3MB’s), ideal for close PCB mounting.
DC input and AC output for an applicable load of 1A at 40°C
.
Compact, thin-profile SSR of monoblock construction with
an all-in-one frame incorporates a PCB, terminals, and a
heatsink.
Approved by UL and CSA. VDE certified models available.
Models with reinforced insulation are available.
Ordering Information
To Order: Select the part number and add the desired coil voltage rating, (e.g., G3MC-101P-DC12).
Note: 1. All models meet UL and CSA standards. In order to obtain VDE approved versions with UL, CSA and VDE Logos, add “-VD” to the part
number. Example: G3MC-101P-VD-DC12
2. 2A models are available with reinforced insulation. Add “-1” to the part number to obain 2A models with reinfored insulation.
Examples: G3MC-202PL-1-DC5 G3MC-202P-VD-1-DC24
Isolation Zero-cross function Built-in snubber circuit Rated output load Rated input voltage Part number
Phototriac Yes Yes 1 A at 100 to 120 VAC
(75 to 132 VAC)
5 VDC G3MC-101P
12 VDC
24 VDC
No 5 VDC G3MC-101PL
12 VDC
24 VDC
Yes 2 A at 100 to 240 VAC
(75 to 264 VAC)
5 VDC G3MC-202P
12 VDC
24 VDC
No 5 VDC G3MC-202PL
12 VDC
24 VDC
378 Solid State Relay G3MC
Specifications
Ratings (Ambient temperature 25°C)
Input
Note: Each model has 5-VDC, 12-VDC, and 24-VDC input versions.
Output
Characteristics
Rated voltage Operating voltage Impedance Voltage levels
Must operate voltage Must dropout voltage
5 VDC 4 to 6 VDC 300Ω ±20% 4 VDC max. 1 VDC min.
12 VDC 9.6 to 14.4 VDC 800Ω ±20% 9.6 VDC max.
24 VDC 19.2 to 28.8 VDC 1.6kΩ ±20% 19.2 VDC max.
Part number Applicable load
Rated load voltage Load voltage range Load current Surge current
G3MC-101P(L)(-VD) 100 to 120 VAC, 50/60 Hz 75 to 132 VAC, 50/60 Hz 0.1 to 1 A 8 A (60 Hz, 1 cycle)
G3MC-202P(L)(-VD)(-1) 100 to 240 VAC, 50/60 Hz 75 to 264 VAC, 50/60 Hz 0.1 to 2 A 30 A (60 Hz, 1 cycle)
Item G3MC-101P(-VD) G3MC-101PL(-VD) G3MC-202P(-VD)(-1) G3MC-202PL(-VD)(-1)
Operate time 1/2 of load power source
cycle + 1 ms
1 ms max. 1/2 of load power source
cycle + 1 ms
1 ms max.
Release time 1/2 of load power source cycle + 1 ms)
Output ON voltage drop 1.6 V (RMS) max.
Leakage current 1 mA max. (at 100 VAC) 1.5 mA max. (at 200 VAC)
Insulation resistance 1,000 MΩ min. (at 500 VDC)
Dielectric strength 2,500 VAC, 50/60 Hz for 1 min (3,000 VAC, 50/60 Hz for 1 min. for G3MC-@@@-VD-1)
Vibration resistance Malfunction: 10 to 55 Hz, 0.75-mm double amplitude
Shock resistance Malfunction: 1,000 m/s2 (approx. 100G)
Ambient temperature Operating:–30°C to 80°C (with no icing or condensation)
Storage:–30°C to 100°C (with no icing or condensation)
Approved standards UL File No. E64562, CSA File No. LR35535
EN60950 File No. 5925UG (“-VD(-1)” type)
Ambient humidity Operating: 45% to 85%
Weight Approx. 2.5g (Approx. 5g for G3MC-202P(L)-VD-1)
Solid State Relay G3MC 379
Engineering Data
G3MC-101P(L)(-VD)
G3MC-202P(L)(-VD)(-1)
Peak inrush current (A)
Energized time (ms)
1.2
1.0
0.8
0.6
0.4
0.2
01008060402002030
Load current (A)
Ambient temperature (°C)
Load Current vs. Ambient
Temperature Characteristics
Inrush Current Resistivity
One cycle, non-repetitive (Keep the inrush current
to half the rated value if it occurs repeatedly.)
2.5
2.0
1.5
1.0
0.5
010080604020 2502030
Load current (A)
Ambient temperature (°C)
Load Current vs. Ambient
Temperature Characteristics
Inrush Current Resistivity
One cycle, non-repetitive (Keep the inrush current
to half the rated value if it occurs repeatedly.)
Peak inrush current (A)
Energized time (ms)
380 Solid State Relay G3MC
Dimensions
Units: mm (inch)
G3MC-202P(L)(-VD)(-1)
G3MC-101P(L)(-VD)
0.8
3.5
2.54
2.54 0.25
1.2
4-1.6 4-0.7
7.6210.16
0.8
3.5
2.54
2.54 0.25
1.2
4-1.6 4-0.7
7.6210.16
13.5 max.
24.5 max.
4.5 max. Four, 1.0-dia. holes
Four, 1.0-dia. holes
4.5 max.
20.5 max.
24.5 max.
PCB Dimensions
(Bottom View)
PCB Dimensions
(Bottom View)
Terminal Arrangement
(Bottom View)
Terminal Arrangement
(Bottom View)
Solid State Relay G3MC 381
Precautions
General Precautions
Do not touch the terminals of the SSR while power is being supplied
to the SSR. The terminals are charged with the power,
and an electric shock may be received by touching the terminals.
The built-in capacitor may have a residual voltage after the SSR
is turned off. Be sure to discharge the residual voltage before touch-
ing the terminals of the SSR, otherwise an electric shock
may be received.
Mounting
1. Make sure that no excessive voltage or current is imposed on or
flows to the input or output circuit of the SSR,
otherwise the SSR may malfunction or burn.
2. Solder the terminals of the SSR properly under the required sol-
dering conditions. The SSR may be abnormally heated and burn
if power is supplied to the terminals soldered incorrectly.
3. Do not short-circuit the load of the SSR while power is supplied to
the SSR. Do not short-circuit the power supply through the SSR.
The SSR may be damaged, malfunction, or burn if the load or
power supply is short-circuited.
Correct use
The terminals of the SSR are highly heat-conductive. Each terminal
must be soldered within 10 s at 260°C or within 5 s at 350°C.
The SSR is of a thin-profile construction. To maintain the vibration
resistance of the SSR, make sure that the space between the SSR
and PCB is 0.1 mm maximum. Lifting of the PCB can be prevented
by setting the hole diameter of the PCBs on both sides slightly
smaller than the actual terminal dimension.
Select the model without the zero-cross function when using the Unit
for phase control output.
The casing works as a heat sink. When mounting two or more Units
closely, make sure that the Units are properly ventilated by taking
ambient temperature rises into consideration. If Units are closely
mounted and used in places with no ventilation, the load current of
each Unit must be 1/2 of the rated load current.
Protective element
No overvoltage absorption element is built in. Therefore, if the G3MC
is connected to an inductive load, be sure to connect the overvoltage
absorption element.
G3MC-@@@PL (without Zero cross function)
G3MC-@@@P (with Zero cross function)
Phototriac
Input
Load
Protective
element
(MOV)
Power
supply
Phototriac
Input
Load
Protective
element
(MOV)
Power
supply
Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website
at http://www.components.omron.com – under the “About Us” tab, in the Legal Matters section.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
382 Solid State Relay G3MC
MEMO
14
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2010.1
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2010 All Right Reserved.
Cat. No. J28I-E-01 06/09 Note: Specications are subject to change. © 2010 Omron Electronics LLC
OMRON CANADA, INC. • HEAD OFFICE


OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE

OMRON ELECTRONICS MEXICO SA DE CV • HEAD OFFICE

OMRON ARGENTINA • SALES OFFICE

OMRON CHILE • SALES OFFICE

OTHER OMRON LATIN AMERICA SALES

OMRON ELECTRONICS LLC • THE AMERICAS HEADQUARTERS
OMRON EUROpE B.V.
