7.087 (180.00)
2.913 (74.00)
70.866 (1800.00)±1.969 (50.00)
1.614 (41.00)
IEC320/C14
0.138 (3.50)
16AWG / 1800mm
DC Plug:Right Angle(ø5.5/ø2.5) L12mm
DC Plug type: V+ -- )-- V-
TRG150A
Mechanical Specification
Specifications TRG150A Series Derating Curve
Typical at 25˚C, nominal line and 60% load, unless otherwise Specified 226
All Dimensions In Inches(mm)
Tolerance Inches: x.xxx= ±0.02
Millimeters: x.xx= ±0.5
Load(%)
100%
90%
80%
70%
60%
50%
40%
30%
Input Volatge(VAC)
Low Voltage Wattage Drating Curve
0%
25%
50%
75%
100%
0510 15 20 25 30 35 40 45 50 55 60 65
Ambient Temperature(˚C)
90 110130 150 170 190210 230 250260
Rated Load(%)
20LFM(Natural Convection)
Load(%)
100%
90%
80%
70%
60%
50%
40%
30%
Input Volatge(VAC)
Low Voltage Wattage Drating Curve
0%
25%
50%
75%
100%
0510 15 20 25 30 35 40 45 50 55 60 65
Ambient Temperature(˚C)
90 110130 150 170 190210 230 250260
Rated Load(%)
20LFM(Natural Convection)
INPUT SPECIFICATIONS:
Voltage …....………........…......................................................... 90~264Vac
Frequency ………………………………………….……………....... 47 to 63Hz
Inrush Current ………………….……………................. 120A max. @240Vac
Conducted EMI ……………………………………..……. CISPR/FCC Class B
Leakage Current ………………………………………........…..... 3.5mA max.
OUTPUT SPECIFICATIONS:
Holdup Time …………………………………..………........ 8ms typ. @115Vac
Short Circuit Protection …………………………….……..……… Continuous
Over Voltage Protection …………………………………………………… Yes
GENERAL SPECIFICATIONS:
Isolation ……………………………………….… Input to output = 4,242VDC
Operating Temperature .....….... 0˚C~65˚C,40~65˚C with 2%/˚C Derating
Storage Temperature ……………………………...…..............….... -20~85˚C
Cooling …………………………………..………………. Natural Convection
Switching Frequency …………………………………...……… 67KHz Typical
Dimensions ……...…. 7.087x2.913x1.614 inches (180.00x74.00x41.00 mm)
Weight ……………………………………………....………… 950g (2.1Pounds)
AC Inlet ……………….……………………...……………...……… IEC320/C14
SAFETY AND EMC:
Emission and lmmunity ……........... EN55022 Class B, FCC Part 15 Class B
EN61000-3-2,EN61000-3-3, EN55024
EN61204-3
Safety ……………………....................... IEC60950-1, EN60950-1, UL60950-1
NOTE:
1. Voltage setpoint at 60% full load.
2. Add a 0.1µF ceramic capacitor and a 47µF E.L. capacitor to output
for Ripple & Noise measurement @20MHz BW.
3. Line regulation measured from 100Vac to 240Vac with full load.
4. Load regulation measured from 60% to 100% full load and from 60%
to 20% full load (60% +/- 40% full load).
5. "Various TRG Series adapters are PSE certified. PSE certification alone
is not sufficient for importation into Japan. A valid PSE mark must
contain the name of the importer as shown in the example below. If
PSE mark is required, the name of the registered
importer must be supplied to Cincon on order placement. Product
labels will not contain PSE mark if importer name is not supplied.
Consult factory or local representative for details".
PS
E
JET
IMPORTER NAME
INPUT AU100-240V, 0.5A
33-44VA, 50-60Hz
OUTPUT DC 5V, 2A