IEC inlet filters FN 390 Versatile filtered power entry module Rated currents up to 10A For one or two fuses Fuses O6.3 x 32mm or O5 x 20mm 2-pole rocker switch Voltage selector Optional earth line choke (E type) Technical specifications Maximum continuous operating voltage: Operating frequency: Rated currents: High potential test voltage: Protection category: Temperature range (operation and storage): Design corresponding to: Flammability corresponding to: MTBF @ 40C/230V (Mil-HB-217F): Voltage selector description: Function: Voltage marking: Series: Parallel: Rocker switch description: Function: Electrical specifications: Mechanical life: Switch ratings: USA (UL): Canada (CSA): Europe (ENEC): * Approvals Typical electrical schematic 250VAC, 50/60Hz 50 to 400Hz 1 to 10A @ 40C max. P -> E 2000VAC for 2 sec P -> N 760VAC for 2 sec IP40 according to IEC 60529 -25C to +85C (25/85/21) UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939 UL 94V-2 or better 2,200,000 hours Standard types Series/parallel N 110-120V 220-240V E Cx R 2xL1 Cx1 2xCy N E P Load Line E types Cx P 2-pole, dark not illuminated Marking I - 0 Inrush current 51A 6,000 on-off operations according to UL 1054, TV 5 10,000 on-off operations according to ENEC 50,000 cycles R 2xL1 Cx1 2xCy Load Line L2 10A, 125VAC; 1/3HP; 10A, 250VAC; 1/2HP 6A, 125VAC; 4A, 250VAC; 1/10HP 10A (4A), 250VAC* Value in () relates to the inductive current charge: cos = 0.65 Features and benefits The FN 390 power entry module combines High conducted attenuation performance, Typical applications based on chokes with high saturation an IEC inlet, mains filter with single or Portable electrical and electronic equipment resistance and excellent thermal behavior. Consumer goods rocker switch. Choosing FN 390 product Rear or front mounting. EDP and office equipment line brings you the rapid availability of a Single or dual-fuse holder. standard filter associated with the necessary USA O6.3 x 32mm or EU O5 x 20mm fuses. safety acceptances. Standard IEC connector 2-pole rocker switch. filters are a practical solution helping you to Voltage selector 110-120V / 220-240V. pass EMI system approval in a short time. Custom-specific versions are available on dual-fuse holder, voltage selector and 2-pole Multiple options designed to offer you the desired solution. request. Single-phase power supplies, switch-mode power supplies Test and measurement equipment > Components > FN 390 Filter selection table Filter Rated current @ 40C (25C) Leakage current* @ 230VAC/50Hz Inductance L1 L2 393-1-05-11 393-2.5-05-11 393-6-05-11 394-1-05-11 394-2.5-05-11 394-6-05-11 [A] 1 (1.2) 2.5 (3) 6 (7.2) 1 (1.2) 2.5 (3) 6 (7.2) [A] 560 560 560 560 560 560 [mH] 7.5 2 0.45 7.5 2 0.45 [mH] FN FN FN FN FN FN FN FN FN FN FN FN 393E-1-05-11 393E-2.5-05-11 393E-6-05-11 394E-1-05-11 394E-2.5-05-11 394E-6-05-11 1 (1.2) 2.5 (3) 6 (7.2) 1 (1.2) 2.5 (3) 6 (7.2) 560 560 560 560 560 560 7.5 2 0.45 7.5 2 0.45 0.4 0.4 0.4 0.4 0.4 0.4 FN FN FN FN FN FN FN FN 1393-1-05-11 1393-2.5-05-11 1393-6-05-11 1393-10-05-11 1394-1-05-11 1394-2.5-05-11 1394-6-05-11 1394-10-05-11 1 (1.2) 2.5 (3) 6 (7.2) 10 (12) 1 (1.2) 2.5 (3) 6 (7.2) 10 (12) 797 797 797 797 797 797 797 797 16 8 2.5 0.6 16 8 2.5 0.6 Cx [nF] 220 220 220 220 220 220 Capacitance Cx1 Cy [nF] 220 220 220 220 220 220 220 220 220 220 220 220 220 220 100 100 100 100 100 100 100 100 Resistance Output R connections [k] 1000 1000 1000 1000 1000 1000 05-11 05-11 05-11 05-11 05-11 05-11 [Qty] 1 1 1 2 2 2 [g] 200 200 200 200 200 200 3.3 3.3 3.3 3.3 3.3 3.3 1000 1000 1000 1000 1000 1000 05-11 05-11 05-11 05-11 05-11 05-11 1 1 1 2 2 2 205 205 205 205 205 205 4.7 4.7 4.7 4.7 4.7 4.7 4.7 4.7 470 470 470 470 470 470 470 470 05-11 05-11 05-11 05-11 05-11 05-11 05-11 05-11 1 1 1 1 2 2 2 2 210 210 210 210 210 210 210 210 Maximum leakage under normal operating conditions. Note: if the neutral line is interrupted, worst case leakage could reach twice this level. ** Filters are delivered without fuse. Product selector FN (1)39xx-y-zz 05-11: Faston 6.3 x 0.8mm 1 to 10: Rated current Blank: Standard version E: Optional earth line choke 3: 1 fuse (O5 x 20mm or O6.3 x 32mm) 4: 2 fuses (O5 x 20mm or O6.3 x 32mm) Blank: Standard version 1: Additional Cx1 capacitor and higher inductivity For example: FN 393-1-05-11, FN 394E-2.5-05-11, FN 1394-10-05-11 Weight [nF] 3.3 3.3 3.3 3.3 3.3 3.3 * Note: for medical versions please contact your local partner within Schaffner`s global network. Fuses** > Components > FN 390 Typical filter attenuation Per CISPR 17; A = 50/50 sym; B = 50/50 asym; C = 0.1/100 sym; D = 100/0.1 sym FN 39x: 1A types FN 39x: 2.5A types FN 39x: 6A types FN 139x: 1A types FN 139x: 2.5A types FN 139x: 6 and 10A types Mechanical data 1 to 10A types Panel cut out A C E 6.3 x 0.8 R M N B G S U H P C J F J D I J Dimensions A B C D E F G H I J M N P R S U 1 to 10A Tolerances 50 65 40 69.5 28 5.5 59.6 O3.3 15 7.5 R 2.5 60.03 29.03 M3 90 15 0.3 0.3 0.1 0.3 0.3 0.2 0.2 All dimensions in mm; 1 inch = 25.4mm Tolerances according: ISO 2768-m / EN 22768-m Your local partner: To find your local partner within Schaffner's global network, please go to www.schaffner.com May 2008