IEC inlet fi lters
FN 390
Versatile fi ltered power entry module
Approvals Rated currents up to 10A
For one or two fuses
Fuses Ø6.3 x 32mm or Ø5 x 20mm
2-pole rocker switch
Voltage selector
Optional earth line choke (E type)
Typical applications
The FN 390 power entry module combines
an IEC inlet, mains filter with single or
dual-fuse holder, voltage selector and 2-pole
rocker switch. Choosing FN 390 product
line brings you the rapid availability of a
standard filter associated with the necessary
safety acceptances. Standard IEC connector
filters are a practical solution helping you to
pass EMI system approval in a short time.
Multiple options designed to offer you the
desired solution.
High conducted attenuation performance,
based on chokes with high saturation
resistance and excellent thermal behavior.
Rear or front mounting.
Single or dual-fuse holder.
USA Ø6.3 x 32mm or EU Ø5 x 20mm fuses.
2-pole rocker switch.
Voltage selector 110-120V / 220-240V.
Custom-specific versions are available on
request.
Portable electrical and electronic
equipment
Consumer goods
EDP and office equipment
Single-phase power supplies, switch-mode
power supplies
Test and measurement equipment
Features and benefits
Technical specifications
Maximum continuous operating voltage: 250VAC, 50/60Hz
Operating frequency: 50 to 400Hz
Rated currents: 1 to 10A @ 40°C max.
High potential test voltage: P –> E 2000VAC for 2 sec
P –> N 760VAC for 2 sec
Protection category: IP40 according to IEC 60529
Temperature range (operation and storage): -25°C to +85°C (25/85/21)
Design corresponding to: UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939
Flammability corresponding to: UL 94V-2 or better
MTBF @ 40°C/230V (Mil-HB-217F): 2,200,000 hours
Voltage selector description:
Function: Series/parallel
Voltage marking:
Series: 110-120V
Parallel: 220-240V
Rocker switch description:
Function: 2-pole, dark not illuminated
Marking I - 0
Electrical specifications: Inrush current 51A
6,000 on-off operations according to UL 1054, TV 5
10,000 on-off operations according to ENEC
Mechanical life: 50,000 cycles
Switch ratings:
USA (UL): 10A, 125VAC; 1/3HP; 10A, 250VAC; 1/2HP
Canada (CSA): 6A, 125VAC; 4A, 250VAC; 1/10HP
Europe (ENEC): 10A (4A), 250VAC*
* Value in () relates to the inductive current charge: cos γ = 0.65
Typical electrical schematic
N
E
P
Line
Cx R 2xL1 2xCy
Load
Cx1
E types
Standard types
N
E
P
Line
Cx R 2xL1 2xCy
Load
L2
Cx1
> Components > FN 390
* Maximum leakage under normal operating conditions. Note: if the neutral line is interrupted, worst case leakage could reach twice this level.
** Filters are delivered without fuse.
Note: for medical versions please contact your local partner within Schaffner‘s global network.
Filter selection table
FN 393-1-05-11 1 (1.2) 560 7.5 220 3.3 1000 05-11 1 200
FN 393-2.5-05-11 2.5 (3) 560 2 220 3.3 1000 05-11 1 200
FN 393-6-05-11 6 (7.2) 560 0.45 220 3.3 1000 05-11 1 200
FN 394-1-05-11 1 (1.2) 560 7.5 220 3.3 1000 05-11 2 200
FN 394-2.5-05-11 2.5 (3) 560 2 220 3.3 1000 05-11 2 200
FN 394-6-05-11 6 (7.2) 560 0.45 220 3.3 1000 05-11 2 200
FN 393E-1-05-11 1 (1.2) 560 7.5 0.4 220 3.3 1000 05-11 1 205
FN 393E-2.5-05-11 2.5 (3) 560 2 0.4 220 3.3 1000 05-11 1 205
FN 393E-6-05-11 6 (7.2) 560 0.45 0.4 220 3.3 1000 05-11 1 205
FN 394E-1-05-11 1 (1.2) 560 7.5 0.4 220 3.3 1000 05-11 2 205
FN 394E-2.5-05-11 2.5 (3) 560 2 0.4 220 3.3 1000 05-11 2 205
FN 394E-6-05-11 6 (7.2) 560 0.45 0.4 220 3.3 1000 05-11 2 205
FN 1393-1-05-11 1 (1.2) 797 16 220 100 4.7 470 05-11 1 210
FN 1393-2.5-05-11 2.5 (3) 797 8 220 100 4.7 470 05-11 1 210
FN 1393-6-05-11 6 (7.2) 797 2.5 220 100 4.7 470 05-11 1 210
FN 1393-10-05-11 10 (12) 797 0.6 220 100 4.7 470 05-11 1 210
FN 1394-1-05-11 1 (1.2) 797 16 220 100 4.7 470 05-11 2 210
FN 1394-2.5-05-11 2.5 (3) 797 8 220 100 4.7 470 05-11 2 210
FN 1394-6-05-11 6 (7.2) 797 2.5 220 100 4.7 470 05-11 2 210
FN 1394-10-05-11 10 (12) 797 0.6 220 100 4.7 470 05-11 2 210
Filter Rated current Leakage current* Inductance Capacitance Resistance Output Fuses** Weight
@ 40°C (25°C) @ 230VAC/50Hz L1 L2 Cx Cx1 Cy R connections
[A] [μA] [mH] [mH] [nF] [nF] [nF] [kΩ] [Qty] [g]
For example: FN 393-1-05-11, FN 394E-2.5-05-11, FN 1394-10-05-11
Product selector
FN (1)39xx-y-zz
05-11: Faston 6.3 x 0.8mm
1 to 10: Rated current
Blank: Standard version
E: Optional earth line choke
3: 1 fuse (Ø5 x 20mm or Ø6.3 x 32mm)
4: 2 fuses (Ø5 x 20mm or Ø6.3 x 32mm)
Blank: Standard version
1: Additional Cx1 capacitor and higher inductivity
> Components > FN 390
Your local partner: To find your local partner within Schaffner’s global network, please go to www.schaffner.com May 2008
Per CISPR 17; A = 50Ω/50Ω sym; B = 50Ω/50Ω asym; C = 0.1Ω/100Ω sym; D = 100Ω/0.1Ω sym
Typical filter attenuation
FN 39x: 1A types FN 39x: 2.5A types FN 39x: 6A types
FN 139x: 1A types FN 139x: 2.5A types FN 139x: 6 and 10A types
All dimensions in mm; 1 inch = 25.4mm
Tolerances according: ISO 2768-m / EN 22768-m
1 to 10A Tolerances
Dimensions
A 50 ±0.3
B 65 ±0.3
C 40 ±0.1
D 69.5 ±0.3
E 28
F 5.5 ±0.3
G 59.6
H Ø3.3
I 15
J 7.5
M R ≤ 2.5
N 60.03 ±0.2
P 29.03 ±0.2
R M3
S 90°
U 15
Mechanical data
1 to 10A types Panel cut out
A
C
B
E
H
GS
FD
I
6.3 x 0.8
J
N
RM
P
C
J
J
U