IEC inlet fi lters
FN 390
Versatile fi ltered power entry module
Approvals■ Rated currents up to 10A
■ For one or two fuses
■ Fuses Ø6.3 x 32mm or Ø5 x 20mm
■ 2-pole rocker switch
■ Voltage selector
■ Optional earth line choke (E type)
Typical applications
The FN 390 power entry module combines
an IEC inlet, mains filter with single or
dual-fuse holder, voltage selector and 2-pole
rocker switch. Choosing FN 390 product
line brings you the rapid availability of a
standard filter associated with the necessary
safety acceptances. Standard IEC connector
filters are a practical solution helping you to
pass EMI system approval in a short time.
Multiple options designed to offer you the
desired solution.
■ High conducted attenuation performance,
based on chokes with high saturation
resistance and excellent thermal behavior.
■ Rear or front mounting.
■ Single or dual-fuse holder.
■ USA Ø6.3 x 32mm or EU Ø5 x 20mm fuses.
■ 2-pole rocker switch.
■ Voltage selector 110-120V / 220-240V.
■ Custom-specific versions are available on
request.
■ Portable electrical and electronic
equipment
■ Consumer goods
■ EDP and office equipment
■ Single-phase power supplies, switch-mode
power supplies
■ Test and measurement equipment
Features and benefits
Technical specifications
Maximum continuous operating voltage: 250VAC, 50/60Hz
Operating frequency: 50 to 400Hz
Rated currents: 1 to 10A @ 40°C max.
High potential test voltage: P –> E 2000VAC for 2 sec
P –> N 760VAC for 2 sec
Protection category: IP40 according to IEC 60529
Temperature range (operation and storage): -25°C to +85°C (25/85/21)
Design corresponding to: UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939
Flammability corresponding to: UL 94V-2 or better
MTBF @ 40°C/230V (Mil-HB-217F): 2,200,000 hours
Voltage selector description:
Function: Series/parallel
Voltage marking:
Series: 110-120V
Parallel: 220-240V
Rocker switch description:
Function: 2-pole, dark not illuminated
Marking I - 0
Electrical specifications: Inrush current 51A
6,000 on-off operations according to UL 1054, TV 5
10,000 on-off operations according to ENEC
Mechanical life: 50,000 cycles
Switch ratings:
USA (UL): 10A, 125VAC; 1/3HP; 10A, 250VAC; 1/2HP
Canada (CSA): 6A, 125VAC; 4A, 250VAC; 1/10HP
Europe (ENEC): 10A (4A), 250VAC*
* Value in () relates to the inductive current charge: cos γ = 0.65
Typical electrical schematic
N
E
P
Line
Cx R 2xL1 2xCy
Load
Cx1
E types
Standard types
N
E
P
Line
Cx R 2xL1 2xCy
Load
L2
Cx1