FC Type Fiber Optic Connectors Harsh Environment MU FC SC HRFC Series Features Attenuators 1. JIS, IEC standard compliant and intermateability test certified. Comply with IEC 61754-13 and JIS C 5970(type F01). FC intermate test by NTT certified connector. 2.Polishing Available with PC polishing, advanced PC(AdPC) polishiing and Angled PC(APC) polishing. 3.Flame resistant Terminators Satisfies flammability rating UL94V-0. Applications POF / PCF Public communications lines, CATV, Test equipment, etc. 30 HRFC SeriesFC Type Fiber Optic Connectors Product Specifications Operating temperature range Return Loss Test Method (IEC 61300) -25C to +70C Specifications (SM) Wavelength 1310nm (LD) 0.5dB max. (PC, AdPC, APC) (GI) Wavelength 1310nm (LED) 0.3dB max. (PC) (SM) (GI) Wavelength 1310nm (LD) 22dB min. (PC), 40dB min. (AdPC), 60dB min. (APC) 22dB min. (PC) Ferrule withdrawal Extract zirconia gauge 2.499 0.0005mm dia from split sleeve. Phosphor bronze split sleeve Zirconia split sleeve Cable retention (Straight pull) 98N tensile load for 1 minute. 1) Insertion loss fluctuation after test: 0.2dB max. 2) No visible damage, dislocation of clamp or cable. Durability (cycles, mating/un-mating) 1000 times Vibration Frequency: 10 to 55 Hz, single amplitude of 0.75mm, 2 hours in each of the 3 axis. Shock Acceleration of 981 m/s2, 6 ms duration, half sine shock pulse, 10 cycles in each of the 3 axis. -10C to 65C, humidity: 90% to 96% 10 cycles Change of temperature -40C to +75C 42 cycles (Complies with Telcordia standard GR-326-CORE) Dry heat 240 hours at 85C Cold 240 hours at -25C Salt mist 48 hours in a 5% concentration of salt mist 1) Insertion loss fluctuation after test: 0.2dB max. 2) No visible damage, cracks or part dislocation. Harsh Environment Humidity (Temperature/ humidity- cycles) 2N to 5.9N 2N to 3.9N MU Environmental Characteristics Insertion Loss Storage temperature range FC Mechanical Characteristics Optical Characteristics Item -25C to +70C SC Ratings No significant corrosion. Materials Material Plug housing Brass, Zinc alloy Spring Stainless steel Ferrule Zirconia Adapter Brass Split sleeve Zirconia or Phosphor bronze Receptacle Brass Attenuators Part Terminators POF / PCF 31 HRFC SeriesFC Type Fiber Optic Connectors SC FC products Plug Housing For 2mm cord, Molded keying ring type FC For 3mm cord, Molded keying ring type MU For 0.9mm fiber, Molded keying ring type Single mode Multi mode Ferrule HRFC-type Connector Harsh Environment Adapter Round type Attenuators Conversion adapter Receptacle POF / PCF Terminators Dust cap 32 Standard type FC to SC Solid Body type Flange type FC to SC HRFC SeriesFC Type Fiber Optic Connectors Plug Housing Please use it with the SC ferrules. SC 52.8 O10 M8x0.75 For 2mm cable CL No. Boot color FC Part Number Polishing type HRFC-P8-H2(63) 701-0075-3-63 Blue PC HRFC-P8-L2(61) 701-0077-9-61 Light purple AdPC HRFC-P8-G2(62) 701-2001-8-62 Green APC Boot color Polishing type Note: Guide key width is 2.1mm O10 M8x0.75 MU 52.8 For 3mm cable CL No. HRFC-P8-H3(62) 701-0074-0-62 Blue PC HRFC-P8-L3(61) 701-0078-1-61 Light purple AdPC HRFC-P8-G3(61) 701-2002-0-61 Green APC Harsh Environment Part Number Note: Guide key width is 2.1mm For 0.9mm fiber M8x0.75 O10 Attenuators 30.8 Part Number Boot color Polishing type 701-0114-3-62 Blue PC HRFC-P15-L(62) 701-0115-6-62 Light purple AdPC HRFC-P15-G(61) 701-2004-6-61 Green APC Terminators CL No. HRFC-P15-H(62) Note: Guide key width is 2.1mm POF / PCF 33 HRFC SeriesFC Type Fiber Optic Connectors Adapters SC Solid Body type 15 4 15 9.5 Panel Cutout M80.75 M80.75 O9 22.2 2M20.4 or 2O2.4 +00.2 9.5 15 FC-A FC +0.5 0 k sin ter .2 O2 oun 1.5 C O4 epth d 13.40.1 Part Number CL No. Split sleeve Remarks HRFC-PA11-G1(40) 701-0071-2-40 Phosphor bronze -------- HRFC-PA11-D1(40) 701-0106-5-40 Zirconia (Note) Note: Please take utmost care when inserting FC plug into a FC adapter. When applying excessive force to the FC plug or inserting in an odd angle, the zirconia sleeve within the adapter might be dameged Standard Body type 1515 44 Harsh Environment Panel Cutout 9.59.5 +0.5 +0.5 0 O9O9 0 2xM2x0.4 2xM2x0.4 2xO2.4+0.2+0.2 0 or or 2xO2.4 0 FC-A FC-A 22.2 22.2 MU 2-M8x0.75 2-M8x0.75 1515 O2.2 O2.2 Countersink depth O4O4 Countersink depth 1.51.5 13.40.1 13.40.1 Part Number CL No. Mark Split sleeve HRFC-PA1-G1(41) 701-0014-9-41 FC-AP Phosphor bronze -------- HRFC-PA1-D1(40) 701-0089-8-40 FC-A Zirconia (Note) Note: Please take utmost care when inserting FC plug into a FC adapter. When applying excessive force to the FC plug or inserting in an odd angle, the zirconia slleve within the adapter might be dameged Flange type Panel Cutout O9 15 15 2 2 +0.5 0 O9 +0.5 0 2xM2x0.4 2xM2x0.4 +0.2 or 2xO2.4 +0.2 0 or 2xO2.4 0 O19 O19 13.45 13.45 22.2 22.2 Attenuators 2-M8x0.75 2-M8x0.75 13.40.1 13.40.1 2xO2.2 2xO2.2 2xO4 Countersink depth 1.5 2xO4 Countersink depth 1.5 Part Number Terminators Remarks CL No. Split sleeve Remarks HRFC-PA4-G1(40) 701-0068-8-40 Phosphor bronze -------- HRFC-PA4-D1(40) 701-0112-8-40 Zirconia (Note) Note: Please take utmost care when inserting FC plug into a FC adapter. When applying excessive force to the FC plug or inserting in an odd angle, the zirconia sleeve within the adapter might be dameged Round type 15 Part Number O8 POF / PCF 22.2 2xM8x0.75 CL No. Split sleeve Remarks HRFC-A2-SF(41) 701-0039-0-41 Phosphor bronze -------- HRFC-A2-SF-D1(40) 701-0140-3-40 Zirconia (Note) Note: Please take utmost care when inserting FC plug into a FC adapter. When applying excessive force to the FC plug or inserting in an odd angle, the zirconia sleeve within the adapter might be dameged 34 HRFC SeriesFC Type Fiber Optic Connectors Conversion adapters Panel Cutout 21.2 5.5 3.5 12.2 SC FC / SC O9+0.5 0 5 2xM8x0.75 12.8 O19 1 2xM2x0.4 or 2xO2.4 +0.2 0 13.40.1 9 13.4 CL No. Split sleeve HSCJ-HRFCJ-B(43) 704-0021-3-43 Phosphor bronze FC Part Number 7.4 O19 9.15 15 FC / SC 9 12.8 32 Part Number CL No. HRFCP-HSCJ-1(61) MU 13.7 (3.9) Split sleeve Polishing type 701-0065-0-61 PC HRFCP-HSCJ-1AS(61) 701-0108-0-61 701-0085-7-61 PC HRFCP-HSCJ-2AS(61) 701-0109-3-61 AdPC GI-50/125 Harsh Environment HRFCP-HSCJ-2(61) AdPC Phosphor bronze Fiber type SM-9.5/125 The positions of SC guide slot and FC guide key will not be always aligned. FC / SC 9 12.8 M8x0.75 21 27.9 (1.8) Part Number CL No. HSCP-HRFCJ-1(61) Split sleeve Polishing type Phosphor bronze AdPC 704-0203-0-61 PC HSCP-HRFCJ-1AS(61) 704-0288-3-61 HSCP-HRFCJ-2(61) Attenuators 7.4 9.4 704-0204-3-61 PC HSCP-HRFCJ-2AS(61) 704-0289-6-61 AdPC Fiber type GI-50/125 SM-9.5/125 Terminators The positions of SC guide key and FC guide slot will not be always aligned. Receptacle 9 3 5.5 9 3 15 5.5 9.5 Panel Cutout 15 9.5 O9 +0.5 0 M8x0.75 M8x0.75 4xM2x0.4 4xM2x0.4 or 4xO2.4 +0.2 0 or 4xO2.4 +0.2 0 9.50.1 CL No. Remarks HRFC-R1(41) 701-0016-4-41 GI HRFC-R2(41) 701-0023-0-41 SM POF / PCF FC-R FC-R 2.2 2.2 4xO2.2 4xO2.2 O4 Countersink depth 1.5 O4 Countersink depth 1.5 Part Number O9 +0.5 0 9.50.1 35 HRFC SeriesFC Type Fiber Optic Connectors Ferrule SC Please use the SC connector's ferrule. FC Dust Cap Part Number MU HRFC-C1(40) Tool Crimp tool POF / PCF Terminators Attenuators Harsh Environment Please use the SC connector's crimp tool . 36 CL No. 701-0019-2-40 Patch cordsVarious patch cords Patch cords Connector Cable Dia. Polishing type O0.9 SC O2.0 AdPC FC O2.0 MU O2.0 Part Number CL No. 1m HSC-ASPK2-F3L-1M(61) 704-1095-5-61 2m HSC-ASPK2-F3L-2M(62) 704-1095-5-62 3m HSC-ASPK2-F3L-3M(63) 704-1095-5-63 1m HSC-ASPAD2-F3Q-1M(21) 704-1170-9-21 2m HSC-ASPAD2-F3Q-2M(22) 704-1170-9-22 3m HSC-ASPAD2-F3Q-3M(23) 704-1170-9-23 1m HRFC-ASPA2-F3L-1M(01) 701-1073-3-01 2m HRFC-ASPA2-F3L-2M(02) 701-1073-3-02 3m HRFC-ASPA2-F3L-3M(03) 701-1073-3-03 1m HRFC-ASP72-F3Q-1M(41) 701-1059-2-41 2m HRFC-ASP72-F3Q-2M(42) 701-1059-2-42 3m HRFC-ASP72-F3Q-3M(43) 701-1059-2-43 1m HMUA-ASPH2-F3L-1M(61) 710-1052-4-61 2m HMUA-ASPH2-F3L-2M(62) 710-1052-4-62 3m HMUA-ASPH2-F3L-3M(63) 710-1052-4-63 1m HMUA-ASP2-F3Q-1M(70) 710-0029-7-70 2m HMUA-ASP2-F3Q-2M(71) 710-0029-7-71 3m HMUA-ASP2-F3Q-3M(72) 710-0029-7-72 MU O0.9 Length FC O0.9 SC Single mode, Polishing type:AdPC (Advanced PC) Harsh Environment Single mode, Polishing type:APC (Angled PC) Connector SC Cable Dia. O2.0 Polishing type APC Part Number CL No. 1m HSC-CSPE2-F3Q-1M(21) 704-3139-0-21 2m HSC-CSPE2-F3Q-2M(22) 704-3139-0-22 3m HSC-CSPE2-F3Q-3M(23) 704-3139-0-23 Length Part Number CL No. 1m HSC-SPK2-F3M7-1M(01) 704-1172-4-01 2m HSC-SPK2-F3M7-2M(02) 704-1172-4-02 3m HSC-SPK2-F3M7-3M(03) 704-1172-4-03 1m HSC-SPAD2-F3P-1M(01) 704-1173-7-01 2m HSC-SPAD2-F3P-2M(02) 704-1173-7-02 3m HSC-SPAD2-F3P-3M(03) 704-1173-7-03 1m HRFC-SP72-F3P-1M(51) 701-1062-7-51 2m HRFC-SP72-F3P-2M(52) 701-1062-7-52 3m HRFC-SP72-F3P-3M(53) 701-1062-7-53 Attenuators Length Multi mode, Polishing type:PC Connector Cable Dia. Polishing type O0.9 SC FC PC O2.0 Terminators O2.0 Please contact HIROSE for other specifications. POF / PCF 37 Patch cordsVarious patch cords Patch cord structure FC SC SC-SC MU FC-FC L+10 0 % Attenuators Harsh Environment MU-MU Please refer to each connector's page for SC, FC or MU type Connector's detail. Other type patch cords Terminators Please select connector and cord specification from Table, and contact HIROSE. Parts Side A connector Side B connector POF / PCF Optical Fiber Cord Item Connector type Polishing type Connector type Polishing type Cord style Fiber mode Cord diameter Length Please contact HIROSE for other specifications. 38 Specified example SC, FC, MU, LC, Simplified SC, Simplified MU AdPC, APC, PC SC, FC, MU, LC, Simplified SC, Simplified MU, None(pigtail) AdPC, APC, PC Simplex, Duplex zipcord SM-9.5/125, MM-50/125 O0.9(Tight buffered), O2, O3 Unit: m Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Hirose Electric: HRFC-R1(41) HRFC-C1(40) HRFC-PA3-G1(40) HRFC-R2(40) HRFC-R2(41) HRFC-P3-H(40) HRFC-P3-H(41) HRFC-A2-SF(41) HRFC-P6-H(40) HRFC-R1-APD HRFC-R1-APD(40) HRFC-R8B(40) HRFC-A3-SF(41) HRFC-C2 HRFC-C2(40) HRFC-PA4-G1(40) HRFC-PA1-A08161(40) HRFCJ-HSTJ-A08163(40) HRFC-PA11-G1(40) HRFCPA11-G1(41) HRFC-PA11-G1(42) HRFC-P8-H3(40) HRFC-P8-H3(41) HRFC-P8-H3(42) HRFC-P8-H2(40) HRFCP8-H2(41) HRFC-P8-H2(42) HRFC-P8-H2(43) HRFC-P8-L2(40) HRFC-P8-L2(41) HRFC-P8-L3(40) HRFC-P8L3(41) HRFC-P8-W3(40) HRFCP-HSCJ-2(40) HRFCP-HSCJ-2(41) HRFC-PA1-D1(40) HRFC-PA1-D1(41) HRFCP12-H(40) HRFC-PA11-D1(40) HRFCP-HSCJ-1AS(40) HRFCP-HSCJ-1AS(41) HRFCP-HSCJ-2AS(40) HRFCPHSCJ-2AS(41) HRFC-P8-W2(40) HRFC-P8-W2(41) HRFC-P8-W2(42) HRFC-PA4-D1(40) HRFC-PA16-D1(40) HRFC-P15-H(40) HRFC-P15-H(42) HRFC-P15-L(40) HRFC-P15-L(42) HRFC-P16-W(40) HRFC-P15-B(40) HRFCP8-W3A(42) HRFC-P8-B2(40) HRFC-P8-B3(40) HRFC-P17-L1.1(40) HRFC-P8-W2B(40) HRFC-P8-W2B(42) HRFC-P15-R(40) HRFC-P8-R2(40) HRFC-A3-SF-D1(40) HRFC-PA1M-D1(40) HRFC-A2-SF-D1(40) HRFC-P8L1.7(40) HRFC-PA15-D1(40) HRFC-P8-G2(40) HRFC-P8-G2(42) HRFC-P8-G2(43) HRFC-P8-G3(40) HRFC-P8G3(41) HRFC-P15-G(40) HRFC-P15-G(41) HSCP-HRFCJ-2AS(41) HRFC-P1-H(60) HRFCP-HSCJ-1(60) HRFC-P8H3(62) HRFC-P8-L2(60) HRFC-P8-W3(60) HRFCP-HSCJ-2(60) HRFCP-HSCJ-2(61) HRFCP-HSCJ-1AS(60) HRFCP-HSCJ-1AS(61) HRFC-P8-W2(61) HRFC-P15-L(60) HRFC-P16-W(60) HRFC-P8-W2B(62) HRFC-P8-G2(60) HRFC-P15-G(60) HRFC-P15-G(61) HRFC-P8-W2B(60) HRFC-P8-W2(60) HRFC-P15-H(61) HRFC-P8-L3(60) HRFCP-HSCJ-2AS(60) HRFC-P8-L1.7(60) HRFC-P8-W2(62) HRFC-P8-W3A(62) HRFC-P15-L(62)