KSZ8895MQX/RQX/FQX/ML
Integrated 5 -Port 10/100 Managed Ethernet
Switch with MII/RMI I Interfac e
Revision 1.3
Micrel Inc. • 2180 Fortune Drive • San Jose, CA 95131 • USA • tel +1 (408) 944-0800 • fax + 1 (408) 474-1000 • http://www.micrel.com
October
26, 2015
Revision 1.3
General Description
The KSZ8895MQX/RQX/FQX/ML is a highly-integrated,
Layer 2 managed, five-port switch with numerous features
designed to reduce system cost. Intended for cost-
sensitive 10/100Mbps five-port switch systems with low
power consumption, on-chip termination, and internal core
power controllers, it supports high-performance memory
bandwidth and shared memory-based switch fabric with
non-blocking configuration. Its extensive feature set
includes po wer managem ent, program mable rate limit and
priority ratio, tag/port-based VLAN, packets filtering, four-
queue QoS prioritization, m anag ement interfaces, and MIB
counters. The KSZ8895 f am ily provides multiple C PU data
interfac es to effec tivel y add res s both c urr ent an d emergin g
fast Ethernet applications when Port 5 is configured to
separate MAC5 with SW5-MII/RMII and PHY5 with P5-
MII/RMII interfaces.
The KSZ8895 family offers three configurations, providing
the flexibility to meet different requirements:
KSZ8895MQX/ML: 5 10/100Base-T/TX transceivers, 1
SW5-MII and 1 P5-MII interface
KSZ8895RQX: 5 10/100Base-T/TX transceivers,
1 SW5-RMII and 1 P5-RMII interface
KSZ8895FQX: 4 10/100Base-T/TX transceivers on
Ports 1, 2, 3 and 5 (port 3 can be set to the fiber
mode). 1 100Base-FX transceivers on Port 4. 1 SW5-
MII and 1 P5-MII interface
All registers of MACs and PHYs units can be managed by
the SPI or the SMI interface. MIIM registers can be
access ed through the MDC/MDIO interfac e. EEPRO M can
set all control registers for the unmanaged mode.
KSZ8895MQX/RQX/FQX are 128-pin PQFP package.
KSZ8895ML is 128-pin LQFP package.
Datasheets and support documentation are available on
Micrel’s web site at: www.micrel.com.
Functional Diagram
Look Up
Engine
Queue
Management
10/100
MAC 1
FIFO, Flow Control, VLAN
Tagging, Priority
SPI
EEPROM
Interface
LED I/F
Auto MDI/MDIX
Control Reg SPI I/F
MIB
Counters
LED0[5:1]
LED1[5:1]
LED2[5:1]
Control
Registers
MDC/MDIO for MIIM and SMI
SW5-MII/RMII or SNI
Auto MDI/MDIX
Auto MDI/MDIX
Auto MDI/MDIX
Auto MDI/MDIX
P5-MII/RMII
10/100
T/TX/FX
PHY3
10/100
T/TX/FX
PHY4
10/100
T/TX
PHY5
KSZ8895MQX/RQX/FQX/ML
10/100
T/TX
PHY1
10/100
T/TX
PHY2
10/100
MAC 2
10/100
MAC 3
10/100
MAC 4
10/100
MAC 5
Buffer
Management
Frame
Buffers
Note:
SW5 indicates the MAC5 of the switch side, P5 indicates the PHY5 of the Port 5.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 2 Revision 1.3
Features
Advanced Switch Features
IEEE 802.1q VLAN support for up to 128 active VLAN
groups (full-range 4096 of VLAN IDs).
Static MAC table supports up to 32 entries.
VLAN ID tag/untag options, per port basis
IEEE 802.1p/q tag insertion or removal on a per port
basis based on ingress port (egress).
Programmable rate limiting at the ingress and egress
on a per port basis.
Jitter-free per packet based rate limiting support.
Broadcast storm protection with percentage control
(global and per port basis).
IEEE 802.1d rapid spanning tree protocol RSTP
support.
Tail tag mode (1 byte added before FCS) support at
Port 5 to inform the processor which ingress port
receives the packet.
1.4Gbps high-performance memory bandwidth and
shared memory-based switch fabric with fully non-
blocking configuration.
Dual MII with MAC5 and PHY5 on port 5, SW5-
MII/RMII for MAC 5 and P5-MII/RMII for PHY 5.
Enable/Disable option for huge frame size up to 2000
Bytes per frame.
IGMP v1/v2 snooping (Ipv4) support for multicast
packet filtering.
IPv4/IPv6 QoS support.
Support unknown unicast/multicast address and
unknown VID packet filtering.
Self-address filtering.
Comprehe nsive C o nfiguration Regi ster Access
Serial management interface (MDC/MDIO) to all PHYs
registers and SMI interface (MDC/MDIO) to all
registers.
High speed SPI (up to 25MHz) and I2C master
Interface to all internal registers.
I/0 pins strapping and EEPROM to program selective
registers in unmanaged switch mode.
Control registers configurable on the fly (port-priority,
802.1p/d /q, AN and so on).
QoS/CoS Packet Prioritization Support
Per port, 802.1p and DiffServ-based.
1/2/4-queue QoS prioritization selection.
Programmable weighted fair queuing for ratio control.
Re-mapping of 802.1p priority field per port basis.
Integrated Five-Port 10/100 Ethernet Switch
New generation switch with five MACs and five PHYs
with fully compliant with IEEE 802.3u standard.
PHYs designed with patented enhanced mixed-signal
technology.
Non-blocking switch fabric assures fast packet
deliver y by utili zing a 1K MAC address lookup table
and a store-and-forward architecture.
On-chip 64Kbyte memory for frame buffering (not
shared with 1K unic as t add r ess table).
Full duplex IEEE 802.3x flow control (PAUSE) with
force mode option.
Half-duplex back pressure flow control.
HP Auto MDI/MDI-X and IEEE Auto crossover
support.
SW-MII interface supports both MAC mode and PHY
mode.
7-wire serial network interface (SNI) support for
legacy MAC.
Per port LED Indicators for link, activity, and 10/100
speed.
Register port status support for link, activity, full/half
duplex and 10/100 speed.
Micrel LinkMD® cable diagnostic capabilities.
On-chip terminations and internal biasing technology
for cost down and lo west p o wer consumption.
Switch Monitoring Features
Port mirroring/monitoring/sniffing: ingress and/or
egress traffic to any port or MII.
MIB counters for fully compliant statistics gathering 34
MIB counters per port.
Loop-back support for MAC, PHY and remote
diagnostic of failure.
Interrupt for the link change on any ports.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 3 Revision 1.3
Features (Continued)
Low Power Dissipation
Full-chip hardware power-down.
Full-chip software power-down and per port software
power down.
Energy-detect mode support < 100mW full chip-power
consumption when all ports have no activity.
Very low full chip power consumption (<0.5W) in
standalone 5-port, without extra power consumption
on transformers.
Dynamic clock tree shutdown feature.
Voltages: Single 3.3V supply with 3.3V VDDIO and
Internal 1.2V LDO controller enabled, or external 1.2V
LDO solution.
Analog VDDAT 3.3V only.
VDDIO support 3.3 V, 2.5V and 1.8V.
Low 1.2V core power .
0.11µm CMOS technology.
Commercial temperature range: 0°C to +70 °C.
Industrial Temperature Range: -40°C to +85°C.
128-pin PQFP and 128-pin LQFP, lead-free package.
Applications
Typical
VOIP phone
Set-top/game box
Automotive
Industrial control
IPTV POF
SOHO residential gateway
Broadband gateway/firewall/VPN
Integrated DSL/cable modem
Wireless LAN access point + gateway
Standalone 10/100 5-port switch
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 4 Revision 1.3
Ordering Information
Part Number Temperature Range Package Description
KSZ8895MQXCA 0°C to 70°C 128-Pin PQFP MII, Pb-Free, Commercial temperature
KSZ8895MQXIA -40°C to +85°C 128-Pin PQFP MII, Pb-Free, Industrial temperature
KSZ8895RQXCA 0°C to 70°C 128-Pin PQFP RMII, Pb-Free, Commercial temperature
KSZ8895RQXIA -40°C to +85°C 128-Pin PQFP RMII, Pb-Free, Industrial temperature
KSZ8895FQXCA 0°C to 70°C 128-Pin PQFP MII, support fiber, Pb-Free, Commercial part
KSZ8895FQXIA -40°C to +85°C 128-Pin PQFP MII, support fiber, Pb-Free, Industrial part
KSZ8895ML 0°C to 70°C 128-Pin LQFP MII, Pb-Free, Commercial temperature
KSZ8895MLI -40°C to +85°C 128-Pin LQFP MII, Pb-Free, Industrial temperature
KSZ8895MQX-EVAL Evaluation Board for KSZ8895MQX
KSZ8895RQX-EVAL Evaluation Board for KSZ8895RQX
KSZ8895FQX-EVAL Evaluation Board for KSZ8895FQX
KSZ8895ML-EVAL Evaluation Board for KSZ8895ML
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 5 Revision 1.3
Revision History
Revision Description Date
1.0 Initial document created O2/21/14
1.1
Update description for Register 1 bits [7:4], update the
descriptions in the section of the internal 1.2V LDO
controller. Update the Pin 125/Pin126 descriptions. Add
evaluation boards in ordering information.
04/28/14
1.2
Update registers 131-134 bits [4:0] descriptions. Update
Figure 16 and Figure 18. Add 100Base-FX data in
Electrical Characteristics Table. Update Figure 3. Update
pin description for Pin 107 and Pin 108. Ad ded si lv er
wire bonding part numbers to Ordering Information.
Updated Ordering Information to include Ordering Part
Number and Device Marking. Add a note for the register
14 bits [4:3].
12/9/14
1.3
Add register 137 (0x89) for 0.11µm and 0.13µm silicon
identification.
Update 1.2V core power high to 1.32V (1.2V+10%) in
Operating Ratings section.
Updated the Ordering Information Table to include only
standard part s number s.
Updated description for Figure 35.
10/26/15
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 6 Revision 1.3
Contents
List of Figures .................................................................................................................................................................. 8
List of Tables ................................................................................................................................................................... 9
System Level Applications ............................................................................................................................................ 10
Pin Configurations ......................................................................................................................................................... 12
Pin Description .............................................................................................................................................................. 14
Pins for Strap-in Options ............................................................................................................................................... 23
Introduction .................................................................................................................................................................... 27
Functional Overview: Physical Layer Transceiver ........................................................................................................ 27
100BASE-TX Transmit .............................................................................................................................................. 27
100BASE-TX Receive ............................................................................................................................................... 27
PLL Clock Synthesizer .............................................................................................................................................. 28
Scrambler/Descrambler (100BASE-TX only) ............................................................................................................ 28
100BASE-FX Operation ............................................................................................................................................ 28
100BASE-FX Signal Detection .................................................................................................................................. 28
100BASE-FX Far End Fault ...................................................................................................................................... 28
10BASE-T Transmit .................................................................................................................................................. 28
10BASE-T Receive ................................................................................................................................................... 28
MDI/MDI-X Auto Crossover ....................................................................................................................................... 28
Straight Cab le ........................................................................................................................................................ 29
Crossover Cable .................................................................................................................................................... 30
Auto-Negotiation ........................................................................................................................................................ 30
LinkMD® Cab le Di agn os tic s ...................................................................................................................................... 32
Access .................................................................................................................................................................... 32
Usage ..................................................................................................................................................................... 32
A LinkMD Example ................................................................................................................................................ 33
On-Chip Termination Resistors ................................................................................................................................. 33
Internal 1.2V LDO Controller ..................................................................................................................................... 33
Functional Overview: Power ......................................................................................................................................... 34
Using Internal 1.2V LDO Controller ........................................................................................................................... 34
Using External 1.2V LDO Regulator ......................................................................................................................... 35
Functional Overview: Power Management ................................................................................................................... 36
Normal Operation Mode ............................................................................................................................................ 36
Energy Detect Mode .................................................................................................................................................. 36
Soft Power Down Mode ............................................................................................................................................. 37
Power Saving Mod e .................................................................................................................................................. 37
Port-Based Power-Down Mode ................................................................................................................................. 37
Functional Overview: Switch Core ................................................................................................................................ 37
Address Look-Up ....................................................................................................................................................... 37
Learning ..................................................................................................................................................................... 37
Migration .................................................................................................................................................................... 37
Aging ......................................................................................................................................................................... 38
Forwarding................................................................................................................................................................. 38
Switching Engine ....................................................................................................................................................... 38
Media Access Controller (MAC) Operation ............................................................................................................... 38
Inter-Packet Gap (IPG) .......................................................................................................................................... 38
Backoff Algorithm ................................................................................................................................................... 38
Late Collision.......................................................................................................................................................... 38
Illegal Frames......................................................................................................................................................... 38
Flow Control ........................................................................................................................................................... 38
Half-Duplex Back Pressure .................................................................................................................................... 41
Broadcast Storm Protection ................................................................................................................................... 41
MII Interface Operation .............................................................................................................................................. 41
Port 5 PHY 5 P5-MII/RMII Interface .......................................................................................................................... 41
Port 5 MAC 5 Switch SW5-RMII Interface for the KSZ8895RQX ............................................................................. 44
SNI Interface Operation ............................................................................................................................................. 46
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 7 Revision 1.3
Advanced Functionality ................................................................................................................................................. 47
QoS Priori t y Support ................................................................................................................................................. 47
Port-Bas ed Priority ................................................................................................................................................. 47
802.1p-Bas ed Priority ............................................................................................................................................ 47
DiffServ-Based Priority ........................................................................................................................................... 48
Spanning Tree Support ............................................................................................................................................. 48
Rapid Spanning Tree Support ................................................................................................................................... 49
Tail Tagging Mode ..................................................................................................................................................... 50
IGMP Support ............................................................................................................................................................ 51
IGMP Snoop ing ...................................................................................................................................................... 51
IGMP Send Back to the Subsc ribed Port ............................................................................................................... 51
Port Mirroring Support ............................................................................................................................................... 51
“Receive Only” Mirror on a Port ............................................................................................................................. 51
“Transmit Only” Mirror on a Port ............................................................................................................................ 51
“Receive and Transmit” Mirror on Two Ports ......................................................................................................... 51
VLAN Support ........................................................................................................................................................... 51
Rate Limiting Support ................................................................................................................................................ 52
Ingress Rate Limit .................................................................................................................................................. 52
Egress Rate Limit ................................................................................................................................................... 53
Transmit Queue Ratio Programming ..................................................................................................................... 53
Filtering for Self-Address, Unknown Unicast/Multicast Address and Unknown VID Packet/IP Multicast ................. 53
Configuration Interface .................................................................................................................................................. 54
I2C Master Serial Bus Configuration .......................................................................................................................... 54
SPI Slave Serial Bus Conf i gurat ion ....................................................................................................................... 55
MII Management Interface (MIIM) ......................................................................................................................... 57
Serial Management Interface (SMI) ....................................................................................................................... 58
Register Descriptions .................................................................................................................................................... 59
Global Registers ........................................................................................................................................................ 60
Port Registers ............................................................................................................................................................ 70
Advanced Control Registers...................................................................................................................................... 80
Data Rate Limit Selection Limit Table ....................................................................................................................... 95
Static MAC Address Table ............................................................................................................................................ 96
Dynamic MAC Address Table ..................................................................................................................................... 101
MIB (Management Information Base) Counters ......................................................................................................... 103
For Port 1................................................................................................................................................................. 103
For Port 2................................................................................................................................................................. 104
For Port 3................................................................................................................................................................. 104
For Port 4................................................................................................................................................................. 104
For Port 5................................................................................................................................................................. 104
MIIM Registers ............................................................................................................................................................ 107
Absolute Maximum Ratings ........................................................................................................................................ 111
Operating Ratings ....................................................................................................................................................... 111
Electrical Characteristics ............................................................................................................................................. 111
Timing Diagrams ......................................................................................................................................................... 114
EEPROM Timing ..................................................................................................................................................... 114
SNI Timing ............................................................................................................................................................... 115
MII Timing ................................................................................................................................................................ 116
SPI Timing ............................................................................................................................................................... 119
Auto-Negotiation Timing .......................................................................................................................................... 121
MDC/MDIO Timing .................................................................................................................................................. 122
Reset Timing ........................................................................................................................................................... 123
Reset Circuit Diagram ............................................................................................................................................. 124
Selection of Isolation Transformer .............................................................................................................................. 125
Selection of Reference Cr ystal .................................................................................................................................... 125
Package Information and Recommended Landing Pattern ........................................................................................ 126
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 8 Revision 1.3
List of Figures
Figure 1. Broadband Gateway .................................................................................................................................... 10
Figure 2. Integrated Broadband Router ...................................................................................................................... 10
Figure 3. Standa lo ne S wit c h ....................................................................................................................................... 11
Figure 4. Using KSZ8895FQX for Dual Media Converter ........................................................................................... 11
Figure 5. T ypical Stra ig ht Cabl e Co nnect io n .............................................................................................................. 29
Figure 6. T ypic a l Cr ossover Cable Connection .......................................................................................................... 30
Figure 7. Auto-Negotiation .......................................................................................................................................... 31
Figure 8. Recommended 1.2V Power Connection using Internal 1.2V LDO Controller ............................................. 34
Figure 9. Recommended 1.2V Power Connection Using the External 1.2V Regulator .............................................. 35
Figure 10. Destination Address Lookup Flow Chart, Stage 1 ....................................................................................... 39
Figure 11. Destination Address Resolution Flow Chart, Stage 2 .................................................................................. 40
Figure 12. 802.1p Pr ior ity Field Form at......................................................................................................................... 47
Figure 13. Tail Tag Frame Format ................................................................................................................................ 50
Figure 14. KSZ88 95MQ X /R Q X /FQ X /ML EEPROM Configuration Timing Diagram ..................................................... 54
Figure 15. SPI Write Data Cycle ................................................................................................................................... 56
Figure 16. SPI Read Dat a C ycle ................................................................................................................................... 56
Figure 17. SPI Mult ip le W r ite ........................................................................................................................................ 56
Figure 18. SPI Multiple Read ........................................................................................................................................ 57
Figure 19. EEPROM Interface Input Receive Timing Diagram ................................................................................... 114
Figure 20. EEPROM Interface Output Transmit Timing Diagram ............................................................................... 114
Figure 21. SNI Input Timing ........................................................................................................................................ 115
Figure 22. SNI Output Timing ..................................................................................................................................... 115
Figure 23. MAC Mode MII Timing Data Received from MII ..................................................................................... 116
Figure 24. MAC Mode MII Timing Data Transmitted from MII ................................................................................. 116
Figure 25. PHY Mode MII Timing Data Received from MII ...................................................................................... 117
Figure 26. PHY Mode MII Timing Data Transmitted from MII .................................................................................. 117
Figure 27. RMII Timing Data Received from RMII ................................................................................................... 118
Figure 28. RMII Timing Data Transmitted to RMII ................................................................................................... 118
Figure 29. SPI Input Timing ........................................................................................................................................ 119
Figure 30. SPI Output Timing ...................................................................................................................................... 120
Figure 31. Auto-Negotiation Timing ............................................................................................................................ 121
Figure 32. MDC/MDIO Timing ..................................................................................................................................... 122
Figure 33. Reset T iming .............................................................................................................................................. 123
Figure 34. Recom mended Res et Circ uit ..................................................................................................................... 124
Figure 35. Recom mended Circ uit for Int erf ac ing with CPU/FPGA Reset ................................................................... 124
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 9 Revision 1.3
List of Tables
Table 1. MDI/MDI-X Pin Definitions ............................................................................................................................ 29
Table 2. Voltages and Power Pins .............................................................................................................................. 34
Table 3. Internal Function Block Status ...................................................................................................................... 36
Table 4. Port 5 PHY P5-MII/RMII Signals ................................................................................................................... 42
Table 5. Switch MAC5 MII Signals .............................................................................................................................. 43
Table 6. Port 5 MAC5 SW5-RMII Connection ............................................................................................................. 45
Table 7. SNI Signals.................................................................................................................................................... 46
Table 8. Tail Tag Rules ............................................................................................................................................... 50
Table 9. FID +DA Look -Up in the VLAN Mode ............................................................................................................ 52
Table 10. FID+SA Look-Up in the VLAN Mode............................................................................................................. 52
Table 11. SPI Connections ........................................................................................................................................... 55
Table 12. MII Management Interface Frame Format .................................................................................................... 57
Table 13. Serial Management Interface (SMI) Frame Format ...................................................................................... 58
Table 14. 10/100BT Rate Selection for the Rate limit ................................................................................................... 95
Table 15. Static MAC Address Table ............................................................................................................................ 96
Table 16. VLAN Table ................................................................................................................................................... 98
Table 17. VLAN ID and Indirect Registers .................................................................................................................. 100
Table 18. Dynamic MAC Address Table ..................................................................................................................... 101
Table 19. Port 1 MIB Counter Indirect Memory Offsets .............................................................................................. 103
Table 20. Format of “Per Port” MIB Counter ............................................................................................................... 104
Table 21. All Port Dropp ed Packet MIB Counters ....................................................................................................... 104
Table 22. Format of “All Dropped Packet” MIB Counter ............................................................................................. 105
Table 23. EEPROM Timing Parameters ..................................................................................................................... 114
Table 24. SNI Timing Parameters ............................................................................................................................... 115
Table 25. MAC Mode MII Timing Parameters ............................................................................................................. 116
Table 26. PHY Mode MII Timing Parameters ............................................................................................................. 117
Table 27. RMII Timing Parameters ............................................................................................................................. 118
Table 28. SPI Input Tim ing Parameters ...................................................................................................................... 119
Table 29. SPI Output Timing Parameters ................................................................................................................... 120
Table 30. Auto-Negotiation Timing Parameters .......................................................................................................... 121
Table 31. MDC/MDIO Typical Timing Parameters ...................................................................................................... 122
Table 32. Reset Timing Parameters ........................................................................................................................... 123
Table 33. Transformer Selection Criteria .................................................................................................................... 125
Table 34. Qualified Magnetic Vendors ........................................................................................................................ 125
Table 35. Typical Reference Crystal Characteristics .................................................................................................. 125
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 10 Revision 1.3
System Level Applications
Figure 1. Broadband Gateway
Figure 2. Integrated Broadband Router
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 11 Revision 1.3
System Level Applications (Continued)
Figure 3. Standalone Switch
Figure 4. Using KSZ8895FQX for Dual Media Converter
Switch Controller
On-Chip Frame Buffers
10/100
PHY 5
5-port
LAN
10/100
MAC 1
10/100
MAC 2
10/100
MAC 3
10/100
MAC 4
10/100
MAC 5
10/100
PHY 1
10/100
PHY 2
10/100
PHY 3
10/100
PHY 4
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 12 Revision 1.3
Pin Configurations
TXM5
VDDAT
FXSD3
TXP5
33
34
35
36
37
38
KSZ8895MQX/RQX/FQX
(Top View)
NC
PMRXDV/PMCRSDV
NC
NC
NC
NC
NC
NC
PWRDN_N
INTR_N
GNDD
VDDC
PMTXEN
PMTXD3
PMTXD2
PMTXD1
PMTXD0
PMTXER
PMTXC/PMREFCLK
GNDD
PMRXD1
VDDIO
PMRXC
PMRXD3
PMRXD2
63
62
61
60
59
58
57
56
55
54
53
52
51
50
49
48
47
46
45
44
43
42
41
40
39
64
FXSD4
LED3-1
LED4-0
LED3-2
SCONF1
SCOL
SMRXD2
VDDIO
SMTXC/SMREFCLK
SMTXD0
SMTXD2
SMTXEN
PCOL
PCRS
PMRXER
LED4-1
LED4-2
LED5-1
LED5-2
VDDC
GNDD
SCONF0
SCRS
SMRXD0
SMRXD1
SMRXD3
SMRXDV/SMCRSDV
SMRXC
GNDD
SMTXER
SMTXD1
SMTXD3
PMRXD0
96
95
94
93
92
91
90
89
88
87
86
85
84
83
82
81
80
79
78
77
76
75
74
73
72
71
70
69
68
67
66
65
LED2-1
LED2-2
VDDIO
GNDD
LED3-0
101
100
99
98
97
LED2-0
102
103
GNDA
LED1-0
MDIXDIS
TEST2
GNDA
IN_PWR_SEL
LDO_O
NC
X2
X1
NC
SCANEN
TESTEN
VDDC
GNDD
RST_N
PS0
PS1
SPIS_N
SPID/SDA
SPIC/SCL
SPIQ
MDIO
MDC
LED1-1
LED1-2104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
VDDAR
RXP1
RXM1
GNDA
TXP1
TXM1
VDDAT
RXP2
RXM2
RXM3
TXP3
RXP4
TXM4
VDDAR
RXM5
GNDA
GNDA
TXP2
TXM2
VDDAR
GNDA
ISET
VDDAT
RXP3
GNDA
TXM3
VDDAT
RXM4
GNDA
TXP4
GNDA
RXP5
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
NC
LED5-0
128-Pin PQFP
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 13 Revision 1.3
Pin Configurations (Continue d)
TXM5
VDDAT
NC
TXP5
33
34
35
36
37
38
KSZ8895ML
(Top View)
NC
PMRXDV
NC
NC
NC
NC
NC
NC
PWRDN_N
INTR_N
GNDD
VDDC
PMTXEN
PMTXD3
PMTXD2
PMTXD1
PMTXD0
PMTXER
PMTXC
GNDD
PMRXD1
VDDIO
PMRXC
PMRXD3
PMRXD2
63
62
61
60
59
58
57
56
55
54
53
52
51
50
49
48
47
46
45
44
43
42
41
40
39
64
NC
LED3-1
LED4-0
LED3-2
SCONF1
SCOL
SMRXD2
VDDIO
SMTXC
SMTXD0
SMTXD2
SMTXEN
PCOL
PCRS
PMRXER
LED4-1
LED4-2
LED5-1
LED5-2
VDDC
GNDD
SCONF0
SCRS
SMRXD0
SMRXD1
SMRXD3
SMRXDV
SMRXC
GNDD
SMTXER
SMTXD1
SMTXD3
PMRXD0
96
95
94
93
92
91
90
89
88
87
86
85
84
83
82
81
80
79
78
77
76
75
74
73
72
71
70
69
68
67
66
65
LED2-1
LED2-2
VDDIO
GNDD
LED3-0
101
100
99
98
97
LED2-0 102
103
GNDA
LED1-0
MDIXDIS
TEST2
GNDA
IN_PWR_SEL
LDO_O
NC
X2
X1
NC
SCANEN
TESTEN
VDDC
GNDD
RST_N
PS0
PS1
SPIS_N
SPID/SDA
SPIC/SCL
SPIQ
MDIO
MDC
LED1-1
LED1-2 104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
VDDAR
RXP1
RXM1
GNDA
TXP1
TXM1
VDDAT
RXP2
RXM2
RXM3
TXP3
RXP4
TXM4
VDDAR
RXM5
GNDA
GNDA
TXP2
TXM2
VDDAR
GNDA
ISET
VDDAT
RXP3
GNDA
TXM3
VDDAT
RXM4
GNDA
TXP4
GNDA
RXP5
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
NC
LED5-0
128-Pin LQFP Pin Configuration
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 14 Revision 1.3
Pin Description
Pin
Number Pin Name Type(1) Port Pin Function(2)
1 MDI-XDIS IPD 1 5 Disable auto MDI/MDI-X.
PD (default) = normal opera tio n.
PU = disable auto MDI/MDI-X on all ports.
2 GNDA GND Analog ground.
3 VDDAR P 1.2V analog VDD.
4 RXP1 I 1 Physical receive sig nal + (differentia l).
5 RXM1 I 1 Physical receiv e sig nal - (differential).
6 GNDA GND Analog ground.
7 TXP1 O 1 Physical transmit sig nal + (differenti al).
8 TXM1 O 1 Physical trans mit signal - (differential).
9 VDDAT P 3.3V analog VDD.
10 RXP2 I 2 Physical receiv e sig nal + (diff e rentia l) .
11 RXM2 I 2 Physical re ceive sig nal - (differential).
12 GNDA GND Analog ground.
13 TXP2 O 2 Physical trans mit sig nal + (dif f erent i al).
14 TXM2 O 2 Physica l tra ns mit sig na l - (differential).
15 VDDAR P 1.2V analog VDD.
16 GNDA GND Analog ground.
17 ISET Set physical transmit output current. Pull-down with a
12.4kΩ1% resistor.
18 VDDAT P 3.3V analog VDD.
19 RXP3 I 3 Physical receiv e sig nal + (diff e rentia l) .
20 RXM3 I 3 Physical re ceive sig nal - (differential).
21 GNDA GND Analog ground.
22 TXP3 O 3 Physical trans mit sig nal + (dif f erent i al).
23 TXM3 O 3 Physica l tra ns mit sig na l (differential).
Notes:
1. P = Power supply.
I = Input.
O = Output.
I/O = Bidirectional.
GND = Ground.
IPU = Input w/internal pul l -up.
IPD = Input w/internal pull-down.
IPD/O = Input w/internal pull-down during reset, output pin otherwise.
OTRI = Output tristated.
2. NC = Do not connect to PCB.
PU = Strap pin pull-up.
PD = Strap pull-down.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 15 Revision 1.3
Pin Description (Continued)
Pin
Number Pin Name Type(1) Port Pin Function(2)
24 VDDAT P 3.3V analog VDD.
25 RXP4 I 4 Physical receiv e sig nal + (diff e rentia l) .
26 RXM4 I 4 Physical re ceive sig nal - (differential).
27 GNDA GND Analog ground.
28 TXP4 O 4 Physical trans mit sig nal + (dif f erent i al).
29 TXM4 O 4 Physica l tra ns mit sig na l - (differential).
30 GNDA GND Analog ground.
31 VDDAR P 1.2V analog VDD.
32 RXP5 I 5 Physical receiv e sig nal + (diff e rentia l) .
33 RXM5 I 5 Physical re ceive sig nal - (differential).
34 GNDA GND Analog ground.
35 TXP5 O 5 Physical trans mit sig nal + (dif f erent i al).
36 TXM5 O 5 Physica l tra ns mit sig na l - (differential).
37 VDDAT P 3.3V analog VDD.
38 NC/FXSD3 IPD 3
FQX: This pin can be floating when port 3 is used as copper port
(default). Por t 3 can be set to fiber mode by Regi ster 239 bit [7], this
pin is used for fiber si gnal detect pin on Port 3 in Fiber mode.
MQX/RQX/ML: no connection.
39 FXSD4 IPD 4 FQX: Fiber signal detect pin for Port 4.
MQX/RQX/ML: no connection.
40 NC NC No connection. Leave NC pin floating.
41 NC NC No connection. Leave NC pin floating.
42 NC NC No connection. Leave NC pin floating.
43 NC NC No connection. Leave NC pin floating.
44 NC NC No connection. Leave NC pin floating.
45 NC NC No connection. Leave NC pin floating.
46 NC NC No connection. Leave NC pin floating.
47 PWRDN_N IPU Full-chip power down. Active low.
48 INTR_N OPU Interrupt. This pin is Open-Dra in output pin.
49 GNDD GND Digital ground.
50 VDDC P 1.2V digital core VDD.
51 PMTXEN IPD 5 PHY [5] MII/RMII transmit enable.
52 PMTXD3 IPD 5 MQX/FQX/ML: PHY [ 5] MII transmit bit 3.
RQX: no connection for RMII.
53 PMTXD2 IPD 5 MQX/FQX/ML: PHY [ 5] MII transmit bit 2.
RQX: no connection for RMII.
54 PMTXD1 IPD 5 PHY [5] MII/RMII transmit bit 1.
55 PMTXD0 IPD 5 PHY [5] MII/RMII transmit bit 0.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 16 Revision 1.3
Pin Description (Continued)
Pin
Number Pin Name Type(1) Port Pin Function(2)
56 PMTXER IPD 5 MQX/FQX/ML: PHY [ 5] MII transmit error. RQX: no connection for
RMII.
57 PMTXC/PMREFCLK I/O 5 MQX/FQX/ML: Output PHY [5] MII transmit clock
RQX: Input PHY [5] RMII reference clock, 50MHz ±50ppm, the
50MHz clock comes from PMRXC Pin 60.
58 GNDD GND Digital ground.
59 VDDIO P 3.3V, 2.5V or 1.8V digital VDD for digital I/O circuitry.
60 PMRXC I/O 5
MQX/FQX/ML: Output PHY [5] MII receive clock.
RQX: Output PHY [ 5] RMII reference clock, this clock is used when
opposite doesn’t provide RMII 50MHz clock or the system doesn’t
provide an external 50MHz clock for the P5-RMII interface.
61 PMRXDV/PMCRSDV IPD/O 5 MQX/FQX/ML: PMRXDV is for PHY [5] MII receive data va lid .
RQX: PMCRSDV is fo r PHY [5] RMII C arrier Sense/R eceiv e D ata
Valid Output.
62 PMRXD3 IPD/O 5
MQX/FQX/ML: PHY [5] MII receive bit 3.
RQX: no connection for RMII.
Strap option:
PD (default) = enable flow control.
PU = disable flow control.
63 PMRXD2 IPD/O 5
MQX/FQX/ML: PHY [5] MII receive bit 2.
RQX: no connection for RMII.
Strap option:
PD (default) = disable back pressure.
PU = enable back pressure.
64 PMRXD1 IPD/O 5
PHY [5] MII/RMII receive bit 1.
Strap option:
PD (default) = drop excessive coll is ion pac ket s.
PU = does not drop excess iv e coll is ion packets.
65 PMRXD0 IPD/O 5
PHY [5] MII/RMII receive bit 0.
Strap option:
PD (default) = disable aggressive back-off algorithm in half-duplex
mode.
PU = enable for performance enhancement.
66 PMRXER IPD/O 5
MQX/FQX/ML:PHY [ 5] MII receive error
RQX: no connection for RMII
Strap option:
PD (default) = packet size 1518/1522 bytes.
PU = 1536 bytes.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 17 Revision 1.3
Pin Descriptions (Continued)
Pin
Number Pin Name Type(1) Port Pin Function(2)
67 PCRS IPD/O 5
MQX/FQX/ML: PHY [5] MII carrier sense.
RQX: no connection for RMII.
Strap option for port 4 only.
PD (default) = force half-duplex if auto-negotiation is disabled or
fails.
PU = force full-duplex if auto negotiation is disabled or fails. Refer to
Register 76.
68 PCOL IPD/O 5
MQX/FQX/ML: PHY [5] MII collision detect.
RQX: no connection.
Strap option for port 4 only.
PD (default) = no force flow control, normal opera tio n.
PU = force flow control. Refer to Register 66.
69 SMTXEN IPD Port 5 Switch MII/RMII transmit enable.
70 SMTXD3 IPD MQX/FQX/ML: Port 5 Switch MII transmit bit 3.
RQX: no connection for RMII.
71 SMTXD2 IPD MQX/FQX/ML: Port 5 Switch MII transmit bit 2.
RQX: no connection for RMII.
72 SMTXD1 IPD Port 5 Switch MII/RMII transmit bit 1.
73 SMTXD0 IPD Port 5 Switch MII/RMII transmit bit 0.
74 SMTXER IPD MQX/FQX/ML: Port 5 Switch MII transmit error.
RQX: no connection for RMII.
75 SMTXC/SMREFCLK
I/O
MQX/FQX/ML: Port 5 Switch MII transmit clock,
Input: SW5-MII MAC mode, Output: SW5-MII PHY modes.
RQX: Input SW5-RMII 50MHz +/-50ppm refere nce cloc k. The
50MHz clock comes from SMRXC Pin 78 when the device is the
clock mode which the device’s clock comes from 25MHz
crystal/oscillator from Pins X1/X2. Or the 50MHz clock comes from
external 50MHz clock source when the device is the normal mode
which the device’s clock source comes from SMTXC pin not from
X1/X2 pins.
76 GNDD GND Digital ground.
77 VDDIO P 3.3V, 2.5V or 1.8V digital VDD for digital I/O circuitry.
78 SMRXC I/O
MQX/FQX/ML: Port 5 Switch MII receive clock,
Input: SW5-MII MAC mode, Output: SW5-MII PHY mode.
RQX: Output SW5-RMII 50MHz clock, this clock is used when
opposite doesn’t provide RMII reference clock or the system doesn’t
provide an external 50MHz clock for the RMII interface.
79 SMRXDV/SMCRSDV IPD/O MQX/FQX/ML: SMRXDV is for Switch MAC 5 MI I receive data valid.
RQX: SMCRSDV is fo r MAC5 RMII Carrier Sense/Receive Data
Valid Output.
80 SMRXD3 IPD/O
MQX/FQX/ML: Port 5 Switch MII receive bit 3.
RQX: no connection for RMII
Strap option:
PD (default) = Disable Switch SW5-MII full-duplex flow control
PU = Enable Switch SW5-MII full-duplex flow control.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 18 Revision 1.3
Pin Description (Continued)
Pin
Number Pin Name Type(1) Port Pin Function(2)
81 SMRXD2 IPD/O
MQX/FQX/ML: Port 5 Switch MII receive bit 2.
RQX: no connection for RMII
Strap option:
PD (default) = Switch SW5-MII in full-duplex mode;
PU = Switch SW5-MII in half-duplex mode.
82 SMRXD1 IPD/O
Port 5 Switch MII/RMII receive bit 1.
Strap option:
PD (default) = Port 5 Switch SW5-MII in 100Mbps mode.
PU = Switch SW5-MII in 10Mbps mode.
83 SMRXD0 IPD/O
Port 5 Switch MII/RMII receive bit 0.
Strap option:
LED mode
PD (default) = mode 0; PU = mode 1. See “Register 11.”
Mode 0, link at:
100/Full LEDx[2,1,0] = 0, 0, 0
100/Half LEDx[2,1,0] = 0, 1, 0
10/Full LEDx[2,1,0] = 0, 0, 1
10/Half LEDx[2,1,0] = 0, 1, 1
Mode 1, link at:
100/Full LEDx[2,1,0] = 0, 1, 0
100/Half LEDx[2,1,0] = 0, 1, 1
10/Full LEDx[2,1,0] = 1, 0, 0
10/Half LEDx[2,1,0] = 1, 0, 1
Mode 0 Mode 1
LEDX_2 Lnk/Act 100Lnk/Act
LEDX_1 Fulld/Col 10Lnk/Act
LEDX_0 Speed Full dupl ex
84 SCOL IPD/O MQX/FQX/ML: Port switch MII collision detect,
Input: SW5-MII MAC modes, Output: SW5-MII PHY modes
RQX: no connection for RMII
85 SCRS IPD/O MQX/FQX/ML: Port switch MII collision detect,
Input: SW5-MII MAC modes, Output: SW5-MII PHY modes
RQX: no connection for RMII
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 19 Revision 1.3
Pin Description (Continued)
Pin
Number Pin Name Type(1) Port Pin Function(2)
86 SCONF1 IPD
Pins 91, 86, and 87 are dual MII/RMII configuration pins for the Port
5 MAC5 MII/RMII and PHY [5] MII/RMII. SW5-MII supports both
MAC mode and PHY modes. P5-MII supports PH Y mode only . See
pins configuration below :
Pin# (91, 86, 87) Port 5 Switch
MAC5 SW5-
MII/RMII
Port5 PHY5
P5- MII/RMII
000 Disable, Otri Disable, Otri
001 PHY Mode MII, or
RMII Disabl e, Otri
010 MAC Mode MII, or
RMII Di sable, O tri
011 PHY Mode SNI Disable, Otri
100 Disable (default) Disable (default)
101 PHY Mode MII or
RMII P5-MII/RMII
110 MAC Mode MII or
RMII P5-MII/RMII
111
PHY Mode SNI
P5- MII/RMII
87 SCONF0 IPD Dual MII/RMII configurat ion pi n. See Pin 86 descriptions.
88 GNDD GND Digital ground.
89 VDDC P 1.2V digital core VDD.
90 LED5-2 IPU/O 5
LED indicator 2.
Strap option:
Aging setup. See “Aging” se cti on.
PU (default) = aging enable
PD = aging disable.
91 LED5-1 IPU/O 5
LED indicator 1.
Strap option:
PU (default): enable PHY [5] MII I/F.
PD: tri-state all PHY [5] MII output. See “Pin 86 SCONF1.”
92 LED5-0 IPU/O 5
LED indicator 0.
Strap option for port 4 only.
PU (default) = Enable auto-negotiation.
PD = Disable auto-negotiation. Strap to Register76 bit [7].
93 LED4-2 IPU/O 4 LED indicator 2.
94 LED4-1 IPU/O 4 LED indicator 1.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 20 Revision 1.3
Pin Description (Continued)
Pin
Number Pin Name Type(1) Port Pin Function(2)
95 LED4-0 IPU/O 4
LED indicator 0.
Strap option:
PU (default) = Normal mode.
PD = Energy Detection mode (EDPD mode)
Strap to Register 14 bits [4:3]
96 LED3-2 IPU/O 3 LED indicator 2.
97 LED3-1 IPU/O 3 LED indicator 1.
98 LED3-0 IPU/O 3
LED indicator 0.
Strap option:
PU (default) = Select I/O drive strength (8mA);
PD = Select I/O drive strength (12mA).
Strap to Register132 bit [7-6].
99 GNDD GND Digital ground.
100 VDDIO P 3.3V, 2.5V or 1.8V digital VDD for digital I/O circuitry.
101 LED2-2 IPU/O 2
LED indicator 2.
Strap option for RQX only:
PU (default) = Select the device as clock mode in SW5- RMII,
25MHz crystal/oscillator to X1/X2 pins of the device and pins of
SMRXC and PMRXC output 50MHz clock.
PD = Select the device as normal mode in SW5-RMII. Switch MAC5
used only. The input clock from X1/X2 pins is not used, the device’s
clock source comes from SMTXC/SMREFCLK pin which the 50MHz
reference clock comes from external 50MHz clock source, PMRXC
can output 50MHz clock for P5-RMII interface in the normal mode.
102 LED2-1 IPU/O 2
LED indicator 1.
Strap option: for Port 3 only.
PU (default) = Enable auto-negotiation.
PD = Disable auto-negotiation. Strap to Register60 bit [7].
103 LED2-0 IPU/O 2 LED indicator 0.
104 LED1-2 IPU/O 1 LED indicator 2.
105 LED1-1 IPU/O 1
LED indicator 1.
Strap option: for port 3 only.
PU (default) = no force flow control, normal opera tio n.
PD = force flow control. Strap to Register60 bit [4].
106 LED1-0 IPU/O 1
LED indicator 0.
Strap option for port 3 only.
PU (default) = force half-duplex if auto-negotiation is disabled or
fails.
PD = force full-duplex if auto negotiation is disabled or fails.
Strap to Register60 bit [5].
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 21 Revision 1.3
Pin Description (Continued)
Pin
Number Pin Name Type(1) Port Pin Function(2)
107 MDC IPU All PHYs MII management (MIIM registers) data clock. Or SMI interface
clock
108 MDIO IPU/O All PHYs MII management (MIIM registers) data I/O. Or SMI interface
data I/O
Note: Need an external pull-up when driven.
109 SPIQ IPU/O All SPI serial data output in SPI slave mode.
Note: Need an ex ternal pull-up when driven.
110 SPIC/SCL IPU/O All (1) Input clock up to 25MHz in SPI slave mode,
(2) Output clock at 61kHz in I2C master mode. See “Pin 113.
Note: Need an external pull-up when driven.
111 SSPID/SDA IPU/O All (1) Serial data input in SPI slave mode;
(2) serial data input/output in I2C master mode. See “Pin 113.”
Note: Need an external pull-up when driven.
112 SPIS_N IPU All
Active low.
(1) SPI data transfer start in SPI slave mode. When SPIS_N is high,
the KSZ8895MQX/RQX/FQX/ML is deselected and SPIQ is held in
high impedance state, a high-to-low transition to initiate the SPI data
transfer.
(2) not used in I2C master mod e.
113 PS1 IPD
Serial bus config urat ion pin.
For this case, if the EEPROM is not present, the
KSZ8895MQX/RQX/FQX/ML will start itself with the PS[1.0] = 00
default register values.
Pin Configuration Serial Bus Configuration
PS[1.0] = 00 I2C Master Mode for EEPROM
PS[1.0] = 01 SMI Interface Mode
PS[1.0] = 10 SPI Slave Mode for CPU Interface
PS[1.0] = 11 Factory Test Mode (BIST)
114 PS0 IPD Serial bus configuration pin. See “Pin 113.”
115 RST_N IPU Reset the KSZ8895MQX/RQX/FQX/ML device. Active low.
116 GNDD GND Digital ground.
117 VDDC P 1.2V digital core VDD.
118 TESTEN IPD NC for normal operation. Factory test pin.
119 SCANEN IPD NC for normal operation. Factory test pin.
120 NC NC No connection. Leave NC pin floating.
121 X1 I 25M Hz crystal clo ck connec tio n/ or 3.3V Oscillator input.
Crystal/Oscillator should be ±50ppm tolerance.
122 X2 O 25MHz crystal clock connec tio n.
123 NC NC No connection. Leave NC pin floating.
124 NC NC No connection. Leave NC pin floating.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 22 Revision 1.3
Pin Description (Continued)
Pin
Number Pin Name Type(1) Port Pin Function(2)
125 LDO_O P
LDO_O pin connect to gate pin of MOSFET if using the internal 1.2V
LDO controller.
LDO_O pin will be floating if using an external 1.2V LDO.
Note: When Pin126 voltage is greater than the internal 1.2V LDO
controller enable threshold (1V), the internal 1.2V LDO controller is
enabled and creat es a 1.2V output when u sin g an ex ternal
MOSFET.
When Pin126 is pull-down, the internal 1.2V LDO contr oll er is
disabled and Pin 125 tri-stated.
126 IN_PWR_SEL I
Pull-up or a resistor divider: Enable internal 1.2V LDO controller.
Pull-down: Disable internal 1.2V LDO controller by a pull-down
resistor.
Note: A 4k pull-up and a 2k pull-down resistors divider network is
recommended if using the internal 1.2V LDO controller and an
external MOSFET for 1.2V power.
A 100Ω (approximately) resistor between the source and drain pins
on the MOSFET is highly recommended as well.
You can also use an ex ternal 1.2V LDO for 1.2V power supply .
127 GNDA GND Analog ground.
128 TEST2 NC NC for normal operation. Factory test pin.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 23 Revision 1.3
Pins for Strap-in Options
The KSZ8895MQX/RQX/FQX/ML can function as a managed switch or an unmanaged switch. If no EEPROM or
micro-contr oller exists , then the KSZ8895 MQX/RQ X/FQX /ML will oper ate from its default s etting. T he stra p-in option
pins can be configur ed b y external pu ll-up/do wn resistors and tak e effect af ter power dow n reset or warm r eset. The
functions are described in the table below.
Pin
Number Pin Name PU/PD(3) Description(4)
1 MDI-XDIS IPD
Disable auto MDI/MDI-X.
Strap option:
PD = (default) = normal operation.
PU = disable auto MDI/MDI-X on all ports.
62 PMRXD3 IPD/O
PHY [5] MII receive bit 3.
Strap option:
PD (default) = enable flow control;
PU = disable flow control.
63 PMRXD2 IPD/O
PHY [5] MII receive bit 2.
Strap option:
PD (default) = disable back pressure;
PU = enable back pressure.
64 PMRXD1 IPD/O
PHY [5] MII receive bit 1.
Strap option:
PD (default) = drop ex cessiv e collis ion pac ket s;
PU = does not drop excessive collision packets.
65 PMRXD0 IPD/O
PHY [5] MII receive bit 0.
Strap option:
PD (default) = disable aggressive back-off algorithm in half-duplex mode;
PU = enable for performance enhancement.
66 PMRXER IPD/O
PHY [5] MII receive error.
Strap option:
PD (default) = 1522/1518 bytes;
PU = packet size up to 1536 bytes.
67 PCRS IPD/O
PHY [5] MII carrier sense
Strap option for Port 4 only.
PD (default) = force half-duplex if auto-negotiation is disabled or fails.
PU = force full-duplex if auto-negotiation is disabled or fails. Refer to Register 76.
68 PCOL IPD/O
PHY [5] MII collision detect
Strap option for Port 4 only.
PD (default) = no force flow control.
PU = force flow control. Refer to Register 66.
Notes:
3. NC = No connect.
IPD = Input w/internal pull -down.
IPD/O = Input w/internal pull-down during reset, output pin otherwise.
IPU/O = Input w/internal pull-up during reset, out put pin otherwise.
4. NC = Do not connect t o PCB.
PD = Strap pin pull-down.
PU = Strap pin pull-up.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 24 Revision 1.3
Pins for Strap-in Options (Continued)
Pin
Number Pin Name PU/PD(3) Description(4)
80 SMRXD3 IPD/O
Switch MII receive bit 3.
Strap option:
PD (default) = disable switch SW5-MII full-duplex flow control;
PU = enable switch SW5-MII full-duplex flow control.
81 SMRXD2 IPD/O
Switch MII receive bit 2.
Strap option:
PD (default) = switch SW5-MII in full-duplex mode;
PU = switch SW5-MII in half-duplex mode.
82 SMRXD1 IPD/O
Switch MII receive bit 1.
Strap option:
PD (default) = switch SW5-MII in 100Mbps mode.
PU = switch MII in 10Mbps mode.
83 SMRXD0 IPD/O
Switch MII receive bit 0.
Strap option: LED mode PD (default) = mode 0; PU = mode 1. See “Register 11.”
Mode 0 Mode 1
LEDX_2 Lnk/Act 100Lnk/Act
LEDX_1 Fulld/Col 10Lnk/Act
LEDX_0 Speed Fulld
86 SCONF1 IPD
Pin 91,86,87 are dual MII/RMII configuration pins for the Port 5 MAC 5 MII/RMII and PHY
[5] MII/RMII. SW5-MII supports both MAC mode and PHY modes. P5-MII supports PHY
mode only. See pins configuration below.
Pins [91, 86, 87] Port 5 Switch MAC5
SW5- MII/RMII Port5 PHY5
P5- MII/RMII
000 Disable, Otri Disable, Otri
001 PHY Mode MII, or RMII Disable, Otri
010 MAC Mode MII, or RMII Disable, Otri
011 PHY Mode SNI Disable, Otri
100 Disable (default) Disable (default)
101 PHY Mode MII or RMII P5-MII/RMII
110 MAC Mode MII or RMII P5-MII/RMII
111
PHY Mode SNI
P5- MII/RMII
87 SCONF0 IPD Dual MII/RMII configuration pin. See Pin 86 description.
90 LED5-2 IPU/O
LED5 indicator 2.
Strap option: Aging setup. See “Aging” section
PU (default) = aging enable;
PD = aging disable.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 25 Revision 1.3
Pins for Strap-in Options (Continued)
Pin
Number Pin Name PU/PD(3) Description(4)
91 LED5-1 IPU/O
LED5 indicator 1.
Strap option:
PU (default): enable PHY [5] MII I/F.
PD: tri-state all PHY [5] MII output. See “Pin 86 SCONF1.”
92 LED5-0 IPU/O
LED5 indicator 0.
Strap option for Port 4 only.
PU (default) = Enable auto-negotiation.
PD = Disable auto-negotiation. Strap to Register76 bit [7].
95 LED4-0 IPU/O
LED indicator 0.
Strap option:
PU (default) = Normal mode.
PD = Energy Detection mode (EDPD mode).
Strap to Register 14 bits [4:3].
98 LED3-0 IPU/O
LED3 indicator 0.
Strap option:
PU (default) = Select I/O current drive stren gth (8mA);
PD = Select I/O current drive strength (12mA).
Strap to Register132 bit [7:6].
101 LED2-2 IPU/O
LED2 indicator 2.
Strap option for KSZ8895RQX only:
PU (default) = Select the device as clock mode in RQX SW5- RMII, 25MHz crystal to
X1/X2 pins of the device and REFCLK output 50MHz clock.
PD = Select the device as normal mode in SW5-RMII. Switch MAC5 used only. The input
clock is useless from X1/X2 pin, the device’s clock comes from SMTXC/SMREFCLK pin,
50MHz reference clock from external 50MHz clock source.
102 LED2-1 IPU/O
LED2 indicator 1.
Strap option for Port 3 only.
PU (default) = Enable auto-negotiation.
PD = Disable auto-negotiation.
Strap to Register60 bit [7].
105 LED1-1 IPU/O
LED1 indicator 1.
Strap option for Por t 3 only.
PU (default) = no force flow control, normal opera tio n.
PD = force flow control. Strap to Register50 bit [4].
106 LED1-0 IPU/O
LED1 indicator 0.
Strap option for Port 3 only.
PU (default) = force half-duplex if auto-negotiation is disabled or fails.
PD = force full-duplex if auto negotiation is disabled or fails.
Strap to Register60 bit [5].
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 26 Revision 1.3
Pins for Strap-in Options (Continued)
Pin
Number Pin Name PU/PD(3) Description(4)
113 PS1 IPD
Serial bus configuration pin. For this case, if the EEPROM is not present, the
KSZ8895MQX/RQX/FQX/ML will start itself with the PS[1:0] = 00 default register values .
Pin Configuration Serial Bus Configuration
PS[1:0] = 00 I
2
C Master Mode for EEPROM
PS[1:0] = 01 SMI Interface Mode
PS[1:0] = 10 SPI Slave Mode for CPU Interface
PS[1:0] = 11 Factory Test Mode (BIST)
114 PS0 IPD Serial bus configuration pin. See “Pin 113.”
128 TEST2 NC NC for normal operation. Factory test pin.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 27 Revision 1.3
Introduction
The KSZ8895MQX/RQX/FQX/ML contains five 10/100 physical layer transceivers and five media access control
(MAC) un its with an integr ated La yer 2 m anaged s witc h. T he device runs in three m odes. T he firs t mode is as a f ive-
port integrat ed switch. T he second is as a f ive-port sw itch with the fif th port decoupled f rom the physical por t. In this
mode, access to the fifth MAC is provided through a media independent interface (MII/RMII). This is useful for
implementing an integrated broadband router. The third mode uses the dual MII/RMII feature to recover the use of
the fifth PHY. This allows the additional broadband gateway configuration, where the fifth PHY may be accessed
through the P5-MII/R MII por t.
The KSZ8895MQX/RQX/FQX/ML has the flexibility to reside in a managed or unmanaged design. In a managed
design, a host processor has complete control of the KSZ8895MQX/RQX/FQX/ML via the SPI bus, or the
MDC/MDIO interfac e. An u nmanaged design is achie ved throug h I/O s trapping or EEPRO M program ming at system
reset time.
On the media side, the KSZ8895MQX/RQX/FQX/ML supports IEEE 802.3 10BASE-T, 100BASE-TX on all copper
ports with Auto MDI/MDIX. The KSZ8895FQX supports 100BASE-FX on port 4, and port 3 is configurable either
copper as default or fiber. The KSZ8895MQX/RQX/FQX/ML can be used as a fully managed five-port switch or
hooked up to a microprocessor by its SW-MII/RMII interfaces for any application solut ions .
Physical signal transmission and reception are enhanced through the use of patented analog circuitry and DSP
technology that make the design more efficient and allows for reduced power consumption and strong electrical
noise imm unit y.
Major enhancements from the KS8995MQ/RQ/FMQ to the KSZ8895MQX/RQX/FQX include more saving power,
there is no a limitation for the center taps of the transformer in KSZ8895MQX/RQX/FQX, KSZ8895MQ/RQ/FMQ
request the c enter t aps of RX an T X of the tr ansform er not to be tie d t oget her f or s aving po w er, ex c ept us ing 0.11um
process and add Micrel LinkMD feature in KSZ8895MQX/RQX/FQX switches. The KSZ8895MQX/RQX/FQX are
complete compatible with KSZ8895MQ/RQ/FMQ.
Functional Overview: Physical Layer Transceiver
100BASE-TX Transmit
The 100BASE-TX transmit function performs parallel-to-serial conversion, 4B/5B coding, scrambling, NRZ-to-NRZI
conversion, MLT3 encoding and transmission. The circuit starts with a parallel-to-serial conversion, which converts
the MII dat a f r om the MAC into a 12 5MH z s eri al b it s tr eam. The data and con trol s tream is then c onverted in to 4B /5B
coding followed by a scrambler. The serialized data is further converted from NRZ-to-NRZI format, and then
transmitted in MLT3 current output. The output current is set by an external 1% 12.4k resistor for the 1:1
transformer ratio. It has a typical rise/fall time of 4ns and complies with the ANSI TP-PMD standard regarding
amplitude balance, overshoot, and timing jitter. The wave-shaped 10BASE-T output is also incorporated into the
100BASE-TX transmitter.
100BASE-TX Receive
The 100BASE-TX receiver function performs adaptive equalization, DC restoration, MLT3-to-NRZI conversion, data
and clock recovery, NRZI-to-NRZ conversion, descrambling, 4B/5B decoding, and serial-to-parallel conversion. The
receiving side starts with the equalization f ilter to compensate for intersymbol interference (ISI) over th e twisted pair
cable. Since the amplitude loss and phase distortion is a function of the length of the cable, the equalizer has to
adjust its characteristics to optimize the performance. In this design, the variable equalizer will make an initial
estimation based on comparisons of incom ing signal strength against some known cable characteristics, then tunes
itself for optimization. This is an ongoing process and can self-adjust against environmental changes such as
temperature variations.
The equalized signal then goes through a DC restoration and data conversion block. The DC restoration circuit is
used to compensate for the effect of baseline wander and improve the dynamic range. The differential data
conversion circuit converts the MLT3 format back to NRZI. The slicing threshold is also adaptive.
The c lock rec overy circuit e xtr acts the 125M H z clock from the edges of the NRZI s ignal. T his recover ed cloc k is then
used to convert the NRZI signal into the NRZ format. The signal is then sent through the de-scrambler followed by
the 4B/5B decoder. Finally, the NRZ serial data is converted to the MII format and provided as the input data to the
MAC.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 28 Revision 1.3
PLL Clock Synthesizer
The KSZ 8895MQX/ RQX/FQX /ML genera tes 125 MHz, 83 MHz, 41M Hz, 25MH z and 10MH z clocks for s ystem timing.
Internal clocks are generated from an external 25MHz crystal or oscillator.
Scrambler/Descrambler (100BASE-TX only)
The purpose of the scrambler is to spread the power spectrum of the signal in order to reduce EMI and baseline
wander. The data is scrambled through the use of an 11-bit wide linear feedback shift register (LFSR). This can
generate a 2047-bit non-repetitive sequence. The receiver will then descramble the incoming data stream with the
same sequence at the transmitter.
100BASE-FX Operation
100BASE-FX operation is very similar to 100BASE-TX operation except that the scrambler/descrambler and MLT3
encoder/ decoder are b ypas s ed on tr ans mission and r e ceptio n. In t h is mode, the auto-ne got iat ion f eature is bypass ed
since there is no standard that supports fiber auto-negotiation.
100BASE-FX Signal Detection
The physical port runs in 100BASE-FX fiber mode for the Port 3 and Port 4 of the KSZ8895FQX. This signal is
internally referenced to 1.2V. The fiber module interface should be set by a voltage divider such that FXSDx ‘H’ is
above this 1.2V reference, indicating signal detect, and FXSDx ‘L’ is below the 1.2V reference to indicate no signal.
There is no aut o-negoti atio n for 100BAS E-FX m ode, t he ports m ust be f orced t o eith er full or half -dup lex for the fiber
ports. Note that strap-in options support Port 3 and Port 4 to disable auto-negotiation, force 100Base-FX speed, force
duplex mode, and force flow control for KSZ8895FQX with unmanaged mode.
100BASE-FX Far End Fault
Far end fault oc curs when the s ignal detec tion is logicall y false from t he receive fiber module. W hen this occurs , the
transmission side signals the other end of the link by sending 84 1s followed by a zero in the idle period between
frames. The far end fault may be disabled through register settings.
10BASE-T Transmit
The output 10BASE-T driver is incorporated into the 100BASE-T driver to allow transmission with the same
magnetics. They are internally wave-shaped and pre-emphasized into outputs with a typical 2.3V amplitude. The
harmonic contents are at least 27dB below the fundamental when driven by an all-ones Manchester-encoded s igna l.
10BASE-T Receive
On the recei ve side, in put buf f er and level detect ing s quelch circ uits ar e em ployed. A diff erentia l input rec eiver circuit
and a PLL perform the decoding function. The Manchester-encoded data stream is separated into clock signal and
NRZ data. A s quelch circ uit rejects s ignals with levels less than 400m V or with short puls ewidths in ord er to prevent
noises at the RXP or RXM input from falsely triggering the decoder. When the input exceeds the squelch limit, the
PLL locks onto the incoming signal and the KSZ8895MQX/RQX/FQX/ML decodes a data frame. The receiver clock is
maintained active during idle periods in between data reception.
MDI/MDI-X Auto Crossover
To eliminate the need for crossover cables between similar devices, the KSZ8895MQX/RQX/FQX/ML supports HP
Auto MDI/MDI-X and IEEE 802.3u standard MDI/MDI-X auto crossover. HP Auto MDI/MDI-X is the default.
The auto-sense function detects remote transmit and receive pairs and correctly assigns transm it and receive pairs
for the KSZ8895MQX/RQX/FQX/ML device. This feature is extremely useful when end users are unaware of cable
types, an d also, saves on an add itional uplink configur ation connecti on. The auto -crossover f eature can b e disabled
through the port control registers, or MIIM PHY registers. The IEEE 802.3u standard MDI and MDI-X definitions are:
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 29 Revision 1.3
Table 1. MDI/MDI-X Pin Definitions
MDI MDI-X
RJ-45 Pins Signals RJ-45 Pins Signals
1 TD+ 1 RD+
2 TD- 2 RD-
3 RD+ 3 TD+
6 RD- 6 TD-
Straight Cable
A straight cable connects an MDI device to an MDI-X device, or an MDI-X device to an MDI device. The following
diagram depicts a typical straight cable connection between a NIC card (MDI) and a switch, or hub (MDI-X).
Figure 5. Typical Straight Cable Connection
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 30 Revision 1.3
Crossover C able
A cross over cab le connec ts an MDI de vice to an oth er MDI d evice, or a n MD I-X dev ice to a nother MD I-X device. T he
following diagram shows a typical crossover cable connection between two switches or hubs (two MDI-X devices).
Figure 6. Typical Crossover Cable Connection
Auto-Negotiation
The KSZ8895MQX/RQX/FQX/ML conforms to the auto-negotiation protocol as described by the 802.3 committee.
Auto-negoti ation allo ws unshielded t wisted pa ir (UT P) link partners to select the highest com m on mode of operation.
Link partners advertise their capabilities to each other, and then compare their own capabilities with those they
received from their link partners. The highest speed and duplex setting that is common to the two link partners is
selected as the mode of operation. Auto-negotiation is supported for the copper ports only.
The following list shows the speed and duplex operation mode from highest to lowest.
Highest: 100Base-TX, full-duplex
High: 100Base-TX, half-duplex
Low: 10Base-T, full-duplex
Lowest: 10Bas e-T, half-duplex
If auto-negotiation is not supported or the KSZ8895MQX/RQX/FQX/ML link partner is forced to bypass auto-
negotiation, the KSZ8895MQX/RQX/FQX/ML sets its operating mode by observing the signal at its receiver. This is
known as parallel detection, and allows the KSZ8895MQX/RQX/FQX/ML to establish link by listening for a fixed
signal protocol in the absence of auto-negotiation advertisement protocol. The auto-negotiation link up process is
shown in the following flow chart.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 31 Revision 1.3
Figure 7. Auto-Negotiation
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 32 Revision 1.3
LinkMD® Cable Diagnostics
The LinkMD® feature utilizes time domain reflectometry (TDR) to analyze the cabling plant for common cabling
problems such as open circuits, short circuits and impedance mismatches.
LinkMD® works by sending a pulse of known amplitude and duration down the MDI and MDI-X pairs and then
analyzes th e s hape of the r ef lec ted s ignal . Timing the pulse d ur ati on g ives an i ndi c ation of the distance t o the cabling
fault with m axim um dis tance of 200m and acc uracy of ± 2m. Inter nal circuitr y displa ys the T DR inf orm ation in a user-
readable digital format.
Note:
Cable diagnost ics are only vali d for copper connections and do not support fi ber optic operat i on.
Access
LinkMD® is initiated b y acces sing the PH Y spec ial con trol/stat us R egister s {26, 42, 58, 74 , 90} an d the Link MD r esult
Registers {27, 43, 59, 75, 91} for ports 1, 2, 3, 4 and 5 respectively; and in conjunction with the Registers Port
Control 12 and 13 for ports 1, 2, 3, 4 and 5 respectively to disable Auto-Negotiation and Auto MDI/MDIX.
Alternatively, the MIIM PHY Registers 0 and 1d can be used for LinkMD® access also.
Usage
The following is a sample procedure for using LinkMD® with Registers {26, 27, 28, 29} on port 1.
1. Disable Auto-Negotiation by writing a ‘1’ to Register 28 (0x1c), bit [7].
2. Disable auto MDI/MDI-X by writing a ‘1’ to Register 29 (0x1d), bit [2] to enable manual control over the differential
pair used to transmit the LinkMD® pulse.
3. A software sequence set up to the internal registers for LinkMD only, see an example below.
4. Start cable diagnostic test by writing a ‘1’ to Register 26 (0x1a), bit [4]. This enable bit is self-clearing.
5. Wait (poll) for Register 26 (0x1a), bit [4] to return a ‘0’, and indicating cable diagnostic test is completed.
6. Read cable diagnostic test results in Register 26 (0x1a), bits [6:5]. The results are as follows:
00 = normal condition (valid test)
01 = open condition detected in cable (valid test)
10 = short condition detected in cable (valid test)
11 = cable diagnostic test failed (invalid test)
The ‘11’ c as e, i nval id t es t, oc c urs when th e KSZ8895 i s unab le t o shut down th e l i nk partner . In t his i nst ance , the
test is not ru n, since it woul d be impossible f or the KSZ8895 t o determ ine if the det ected signal is a reflection of
the signal generated or a signal from another source.
7. Get distance to fault by concatenating Register 26 (0x1a), bit [0] and Register 27 (0x1b), bits [7:0]; and
multiplying the result by a constant of 0.4. The distance to the cable fault can be determined by the following
formula:
D (distance to cable fault) = 0.4 x { (Register 26, bit [0]),(Register 27, bits [7:0]) }
D (distance to cable fault) is expressed in meters.
Concatenated value of Registers 26 bit [0] and 27 bit [7:0] should be converted to decimal before decrease 26
and multiplying by 0.4.
The constant (0.4) may be calibrated for different cabling conditions, including cables with a velocity of
propagation that varies significantly from the norm.
For port 2, 3, 4, 5 and for the MIIM PHY registers, LinkMD® usage is similar.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 33 Revision 1.3
A LinkMD Example
The following is a sample procedure for using LinkMD® on port 1.
//Set Force 100/Full and Force MDIX mode
//W is WRITE the register. R is READ register
W 1c ff
W 1d 04
//Set Internal Registers Temporary Adjustment for LinkMD
W 47 b0
W 27 00
W 37 03 (03- port 1, 04-port2, 05-port3, 06-port4, 07-port5)
W 47 80 (bit7-port1, bit6-port2, bit5-port3, bit4-por t4, bi t3-port5)
W 27 00
W 37 00
//Enable LinkMD Testing with Fault Cable for port 1
W 1a 10
R 1a
R 1b
//Result analysis based on the values of the Register 0x1a and 0x1b for port 1:
//The Register 0x1a bits [6-5] are for the open or the short detection.
//The Register 0x1a bit [0] + the Register 0x1b bits [7-0] = Vct_Fault [8-0]
//The distance to fault is about 0.4 x {Vct_Fault [8-0] 26}
Note:
After end the testing, set all registers above to their default value, the default values are 00for the Register (0x37) and the Register (0x47)
On-Chip Termination Resistors
The KSZ8895MQX/RQX/FQX/ML reduces the board cost and simplifies the board layout by using on-chip
termination resistors for all ports and RX/TX differential pairs without the external termination resistors. The
combination of the on-chip termination and internal biasing will save power consumption as compared to using
external b iasing and termination resistors, and the transformer will not consum e power an y more. The cent er tap of
the trans former does not need to b e tied to the analog power a nd does not t ie the cent er taps togeth er between RX
and TX pairs for its application.
Internal 1.2 V LDO Controller
The KSZ8895MQX/RQX/FQX/ML r educ es board cos t and s implifies bo ar d layout b y integr at ing an intern al 1.2V LDO
controller to drive a low cost MOSFET to supply the 1.2V core power voltage for a single 3.3V power supply solution.
The internal 1.2V LDO controller can be disabled by Pin 126 IN_PWR_SEL pull-down in order to use an external
1.2V LDO.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 34 Revision 1.3
Functional Overview: Power
The KSZ8895 device has two options for the power circuit in the design. one is a single 3.3V supply with 3.3V I/O
power by using internal 1.2V LDO controller and one MOSFET for 1.2V analog and digital power. Another one is
using external 1.2V LDO and provide 1.2V power for 1.2V analog and digital power. Table 2 illustrates the various
voltage options and requirements of the device.
Table 2. Voltages and Power Pins
Power Signal
Name Device Pins Requirement
VDDAT 9,18,24,37 3.3V analog power to the transceiver of the device.
VDDIO 59,77,100 Choice of 1.8V or 2.5V or 3.3V for the I/O circuits. These input power pins
power the I/O circuitry of the device.
VDDAR 3, 15, 31 Filtered 1.2V analog voltage. This is where filtered 1.2V is fed back into the
device to power the Analog bl ock.
VDDC 50,89,117 Filtered 1.2V digital voltage. This pin feeds 1.2V to digital circuits within the
Analog block.
GNDA 2,6,12,16,21,27,30,34,127 Analog Ground.
GNDD 49,58,76,88,99,116 Digital Ground.
Using Internal 1.2V LDO Controller
The preferred method of using the internal 1.2V LDO controller with an external MOSFET is illustrated in the figure
below. The number of capacitors, ferrite beads (FB), values of capacitors, and exact placement of components will
depend on the specific design. The 1.2V rail from the drain pin of the MOSFET to VDDAR Pin 3 is the 1.2V LDO
feedback path. This connection should be as short as possible and there should be no series components on this
feedback path. When the voltage of Pin 126 is just ov er 1V a long with the 3.3V power-up the i nternal 1.2V LDO
controller is enabled. The 1.2V LDO regulator (internal 1.2V LDO controller plus an external MOSFET) requests
about 3.0V voltage at the ‘S’ pin of MOSFET when the internal 1.2V LDO controller is just enabled, the resistor
divider will meet this requirement.
FB
125
VDDAT
9,18,24,37
3,15,31
3.3V 1.2V
126 VDDAR
VDDC 50,89,117
VDDIO
59,77,100
GNDA
GNDD
2,6,12,16,21,27,30,34,127 49,58,76,88,99,116
4K
2K
DS
G
100ohm
Figure 8. Recommended 1.2V Power Connection using Internal 1.2V LDO Controller
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 35 Revision 1.3
Using External 1.2V LDO Regulator
The KSZ8895MQX/RQX/FQX/ML can use an external 1.2V LDO regulator too. When use an external 1.2V LDO
regulator solution, the Pin 126 should be pulled down by the pull-down resistor to disable the internal 1.2V LDO
controller. There is no a power sequence request if all power rails voltage are ready after the power-up reset done.
Using the external 1.2V LDO regula tor is illustr ated in Figure 9. T he number of capacitors, values of capacit ors, and
exact placement of components will depend on the specific design.
FB
125
VDDAT
9,18,24,37
3,15,31
126 VDDAR
VDDC 50,89,117
VDDIO
59,77,100
GNDA
GNDD
2,6,12,16,21,27,30,34,127 49,58,76,88,99,116
1K
1.2V
Figure 9. Recommended 1.2V Power Connection Using the External 1.2V Regulator
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 36 Revision 1.3
Functional Overview: Power Management
The KSZ8895MQX/RQX/FQX/ML supports a full chip hardware power down mode. When the PWRDN Pin 47 is
internally activated low (pin PW RDN = 0), the entire chip is po wered do wn. If this pin is de-asserted, the c hip will be
reset internally.
The KSZ8895MQX/RQX/FQX/ML can also use multiple power levels of 3.3V, 2.5V or 1.8V for VDDIO to support
different I/O voltage.
The KSZ8895MQX/RQX/FQX/ML supports enhanced power management in a low power state, with energy
detection to ensure low power dissipation during device idle periods. There are five operation modes under the
power management function which are controlled b y the Register 14 bit [4:3] and the Port Register Control 13 bit 3
as shown below:
Register 14 bits [4:3] = 00 Normal Operation Mode
Register 14 bits [4:3] = 01 Energy Detect Mode
Register 14 bits [4:3] = 10 Soft Power Down Mode
Register 14 bits [4:3] = 11 Power Sa ving Mod e
The Port R e gister 29, 45, 61, 77, 93 Control 13 bit3 = 1 are for the Port Based Power-Do wn Mod e.
Table 3 indicates all internal function blocks’ status under four different power management operation modes.
Table 3. Internal Function Block Status
KSZ8895MQX/RQX/FQX/ML
Function Blocks Power Management Operation Modes
Normal M ode
Power Saving Mode
Energy Detect Mode
Soft Power-Down Mode
Internal PLL Clock Enabled Enabled Disabled Disabled
Tx/Rx PHY Enabled Rx unused block
disabled Energy detect at Rx Disabled
MAC Enabled Enabled Disabled Disabled
Host Interface Enabled Enabled Disabled Disabled
Normal Operation Mode
This is the default setting bits [4:3] = 00 in Register 14 after chip power-up or hardware reset. When
KSZ8895 MQX /RQ X /F QX /ML is i n n ormal opera tio n mode, all P LL c locks ar e ru nni ng, PH Y and MAC ar e o n, a nd the
host interface is ready for CPU READ or WRITE.
During normal operation mode, the host CPU can set the bits [4:3] in Register 14 to change the current normal
operation mode to any one of the other three power management operation modes.
Energy De tect Mode
Energy detect mode provides a mechanism to save more power than in the normal operation mode when the
KSZ8895MQX/RQX/FQX/ML port is not connected to an active link partner. In this m ode, the device will save more
power when th e cables are unplugged. If the cable is not plugged in, th e devic e can autom aticall y enter a l ow power
statethe energy detect mode. In this m ode, the device will keep transm itting 120ns width p ulses at 1 pulse/s rate.
Once activity resumes due to plugging a cable in or attempting by the far end to establish link, the device can
automatically power up to normal power state in energy detect mode.
Energy detect mode consists of two states, normal power state and low power state. While in low power state, the
device reduces power consumption by disabling all circuitry except the energy detect circuitry of the receiver. The
energ y detec t mode is en tered b y setting bits [4:3] = 01 in Reg ister 14. W hen the KSZ88 95MQX/RQX /FQX/ML is in
this m ode, it wi ll monitor t h e cabl e e ner gy. If there is no energy on the ca ble f or a time longer tha n th e pr e-configured
value at bit [7:0] Go-Sleep time in Register 15, the device will go into low power state. When
KSZ8895MQX/RQX/FQX/ML is in low power state, it will keep monitoring the cable energy.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 37 Revision 1.3
Once the energy is detected from the cable, the d evice will enter normal power state. When the device is at normal
power state, it is able to transmit or receive packet from the cable.
Soft Power Down Mode
The s oft power down m ode is en tered b y sett ing b its [4:3] = 10 in Reg ister 14. W hen KSZ889 5MQ X /RQ X /FQ X /ML is
in this m ode, all PLL cl ocks are dis abled, also all of PH Ys and the MACs ar e off. An y dumm y host acc ess will wake-
up this device from current soft power down mode to normal operation mode and internal reset will be issued to
make all internal registers go to the default values.
Power Saving Mode
The po wer saving m ode is enter e d when a uto-negotia t ion mode is ena ble d, t he cabl e is d is connected, and b y setting
bits [4:3] = 11 in Reg ister 14. W hen KSZ88 95MQX/ RQX /FQ X/ML is in this m ode, all PLL cloc k s are enabled, MAC is
on, all internal register values will not change, and th e host interface is read y for CPU read or write. In this mode, it
mainly controls the PHY transceiver on or off, based on line status to achieve power saving. The PHY continues to
transm it, only turning off the unused receiver bloc k. Once activit y resum es, due to plugging a c able or attemptin g by
the far end to establish link, the KSZ8895MQX/RQX/FQX/ML can automatically enable the PHY to power up to
normal power state from power saving mode.
During p ower sa ving mode , the host CPU can set bits [4:3] in Register 14 to cha nge the c urrent po wer savi ng mode
to any one of the other three power management operation modes.
Port-Based Power-Down Mode
In add ition, the KSZ8895MQX/RQX/FQX/ML features a per -port power-down mode. T o sa ve power, a PHY port that
is not in use can be po were d do wn via the Registers Port Control 13 bit 3, or MIIM PHY Registers 0 bit 11.
Functional Overview: Switch Core
Address Look-Up
The internal look -up table stores MAC addresses and their associated inform ation. It contains a 1K unicast address
table plus switching information. The KSZ8895MQX/RQX/FQX/ML is guaranteed to learn 1K addresses and
distinguishes itself from a hash-based look-up table, which, depending on the operating environment and
probabilities, may not guarantee the absolute number of addresses it can learn.
Learning
The internal look-up engine updates its table with a new entry if the following conditions are met:
The received packet’s source address (SA) does not exist in the look-up table.
The received packet is good; the packet has no receiving errors and is of legal length.
The look -up engine inser ts the qua lified S A into the ta ble, along with t he port nu mber and tim e stamp. If the table is
full, the last entry of the table is deleted first to make room for the new entry.
Migration
The int ernal look -up eng ine als o m onitors whet her a s tatio n is m oved. If this occ urs, it updat es th e tab le ac co rdingl y.
Migration happens when the following conditions are met:
The received packet’s SA is in the table but the associated source port information is different.
The received packet is good; the packet has no receiving errors and is of legal length.
The look-up engine will update the existing record in the table with the new source port information.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 38 Revision 1.3
Aging
The look -up e ngine will u pdate the t im e stam p inf ormatio n of a recor d whenever t he corres pond ing SA ap pears . T he
time stamp is used in the aging process. If a record is not updated for a period of time, the look-up engine will
remove the record from the table. The look-up engine constantly performs the aging process and will continuously
remove aging records. The aging period is 300 +/- 75 seconds. This feature can be enabled or disabled through
Register 3 or by external pull-up or pull-down resistors on LED[5][2]. See “Register 3” section.
Forwarding
The KSZ8 895MQX/ RQX/FQX /ML will f orward pac kets usin g an alg orithm that is dep icted in t he follo wing flo wcharts .
Figure 6 shows stage one of the forwarding algorithm where the search engine looks up the VLAN ID, static table,
and dynamic table for the destination address, and comes up with “port to forward 1” (PTF1). PTF1 is then further
modified by the spanning tree, IGMP snooping, port mirroring, and port VLAN processes to come up with “port to
forward 2” (PTF2), as shown in Figure 7. This is where the packet will be sent.
The KSZ8895MQX/RQX/FQX/ML will not forward the following packets:
Error packets. These include framing errors, FCS errors, alignment errors, and illegal size packet errors.
802.3x p ause f ram es. T he KSZ8895MQX/RQX/FQX/ML will interc ept th ese pac k ets and per form the appro priate
actions.
“Local” packets. Based on destination address (DA) look-up. If the destination port from the look-up table
matches the port where the packet was from, the packet is defined as “local.”
Switching Engine
The KSZ8895MQX/RQX/FQX/ML features a h ig h-per f ormanc e switchi ng e ng ine t o move data to and fr om the MAC’s
packet buffers. It operates in store and forward mode, while the efficient switching mechanism reduces overall
latenc y. The KSZ8895MQX/RQX/FQX/ML has a 64k B intern al fram e buffer . This res ource is shared b etween all five
ports. There are a total of 512 buffers available. Each buffer is sized at 128B.
Med ia Access Cont rol le r (MAC) Operation
The KSZ8895MQX/RQX/FQX/ML strictly abides by IEEE 802.3 standards to maximize compatibility.
Inter-Packet Gap (IPG)
If a frame is successfully transmitted, the 96-bit time IPG is measured between the two consecutive MTXEN. If the
current packet is experiencing collision, the 96-bit time IPG is measured from MCRS and the next MTXEN.
Backoff Algorithm
The KSZ8895MQX/RQX/FQX/ML implements the IEEE Standard 802.3 binary exponential backoff algorithm, and
optional “a ggressive m ode” back off. After 16 c ollisions, the packet will be optionall y dropped , depending on the ch ip
configuration in Register 3. See “Register 3.”
Late Collision
If a transmit packet experiences collisions after 512-bit times of the transmission, the packet will be dropped.
Illegal Frames
The KSZ8895MQX/RQX/FQX/ML discards frames less than 64 bytes and can be programmed to accept frames up
to 1536 bytes in Register 4. For special applications, the KSZ8895MQX/RQX/FQX/ML can also be programmed to
accept frames up to 1916 bytes in Register 4. Since the KSZ8895MQX/RQX/FQX/ML supports VLAN tags, the
maximum sizing is adjusted when these tags are present.
Flow Control
The KSZ8895MQX/RQX/FQX/ML supports standard 802.3x flow control frames on both transmit and receive sides.
On the receive side, if the KSZ8895MQX/RQX/FQX/ML receives a pause control frame, the
KSZ8895MQX/RQX/FQX/ML will not transmit the next normal frame until the timer, specified in the pause control
fram e, expires . If a noth er paus e fr am e is recei ved b efor e the c urre nt tim er ex pires , the tim er will be u pdated with t he
new value in the second pause frame. During this period (being flow controlled), only flow control packets from the
KSZ8895MQX/RQX/FQX/ML will be transmitted.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 39 Revision 1.3
On the tr ansm it side, t he KSZ8895MQX/RQX/FQX/ML has inte lligent a nd eff icient wa ys to d eterm ine wh en to in voke
flow control. The flow control is based on availability of the system resources, including available buffers, available
transmit queues and available receive queues.
The KSZ8895MQX/RQX/FQX/ML f low contro ls a port that has just recei ved a pack et if the destinatio n port resourc e
is busy. The KSZ8895MQX/RQX/FQX/ML issues a flow control frame (XOFF), containing the maximum pause time
defined in IEEE standard 802.3x. Once the resource is freed up, the KSZ8895MQX/RQX/FQX/ML sends out the
other flow control frame (XON) with zero pause tim e to turn off the flow contro l (turn on transmission to the port). A
hysteresis feature is also provided to prevent over-activation and deactivation of the flow control mechanism.
The KSZ8895MQX/RQX/FQX/ML flow controls all ports if the receive queue becomes full.
Figure 10. Destination Address Lookup Flow Chart, Stage 1
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 40 Revision 1.3
Figure 11. Destination Address Resolution Flow Chart, Stage 2
The KSZ8895MQX/RQX/FQX/ML will not for ward the f ollowing pac kets:
1. Error packets
These include framing errors, Frame Check Sequence (FCS) errors, alignment errors, and illegal size packet errors.
2. IEEE802.3x PAUSE frames
KSZ8895MQX/RQX/FQX/ML intercepts these packets and performs full duplex flow control accordingly.
3. "Local " packets
Based on d estination addr ess (DA) look up, if the d estination port f rom the look up table matches the port from which
the packet originated, the packet is defined as "local."
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 41 Revision 1.3
Half-Duplex Back Pressure
The KSZ8895MQX/RQX/FQX/ML also provides a half-duplex back pressure option (note: this is not in IEEE 802.3
standards). The activation and deactivation conditions are the same as the ones given for full-duplex mode. If back
pressure is required, the KSZ8895MQX/RQX/FQX/ML sends preambles to defer the other station's transmission
(carrier sense deference). To avoid jabber and excessive deference as defined in IEEE 802.3 standards, after a
certain period of tim e, the KSZ8895MQX/RQX/FQX/ML discontinues carrier sense but raises it quickly after it drops
packets to inhibit other transmissions. This short silent time (no carrier sense) is to prevent other stations from
sending out p ac kets and keeps ot her s t ati ons in a car r ier s ens e-def err ed s tate . If the por t has pack ets to s en d d ur in g
a back pressure situation, the carrier sense-type back pressure is interrupted and those packets are transmitted
instead. If there are no more packets to send, carrier sense-type back pressure becomes active again until switch
resources are free. If a collision occurs, the binary exponential backoff algorithm is skipped and carrier sense is
generated imm ediatel y, red ucing t he chanc e of fur ther coll iding and m aintainin g c arr ier sense t o pre vent rec epti on of
packets. To ensure no packet loss in 10BASE-T or 100BASE-TX half-duplex modes, the user must enable the
following:
Aggressive backoff (Register 3, bit 0)
No excessive collision drop (Register 4, bit 3)
Back pressure (Register 4, bit 5)
These bits are not set as the default because this is not the IEEE standard.
Broadcast Storm Protection
The KSZ8895MQX/RQX/FQX/ML has an intelligent option to protect the switch system from receiving too many
broadcast packets. Broadcast packets are normally forwarded to all ports except the source port and thus use too
many switch resources (bandwidth and available space in transmit queues). The KSZ8895MQX/RQX/FQX/ML has
the option to include “multicast packets” for storm control. The broadcast storm rate parameters are programmed
globall y and can be enabl ed or disabled on a per port bas is. The r ate is b ased on a 50m s (0.05s) interval f or 100BT
and a 500ms (0.5s) interval for 10BT. At the beginning of each interval, the counter is cleared to zero and the rate
limit mechanism s tar ts to count t he number of b ytes d uring the int er val. The rate def init ion is d es cr ibed in R e gist ers 6
and 7. The default setting for Registers 6 and 7 is 0x4A (74 decimal). This is equal to a rate of 1%, calculated as
follows:
148,80 frames/sec X 50ms (0.05s)/interval X 1% = 74 frames/interval (approx.) = 0x4A
MII Interface Operation
The media-independent interface (MII) is specified by the IEEE 802.3 committee and provides a common interface
between ph ysical layer and MAC la yer dev ices. T he KSZ88 95MQX/RQX /FQX/ML provides two such int erfaces . The
P5-MII interface is used to connect to the fifth PHY, where as the SW-MII interface is used to connect to the fifth
MAC. Each of these MII interfaces contains two distinct groups of signals, one for transmission and the other for
receiving.
Port 5 PHY 5 P5-MII/RMII Interface
The media independent interface (MII) is specified by the IEEE 802.3 committee and provides a common interface
between the physical layer and MAC layer devices. The Reduced Media Independent Interface (RMII) specifies a low
pin count MII . The KSZ8 895MQ X/RQ X/FQ X/ML prov ides t wo such in terf aces f or MAC5 and PHY5. T he Port 5 PHY5
P5-MII/RMII interface is used to connect to the fifth PHY, where as the SW -MII/RMII interface is used t o connect to
the fifth MAC. The KSZ8895MQX/FQX/ML support P5-MII, the KSZ8895RQX supports P5-RMII. Each of these
MII/RMII interf aces contains two distinct groups of signals, one for transm ission and the other for receiving. Table 4
describes the signals used in the PHY [5] P5-M II/RMII interface. The P5-MII int er f ac e operates in PH Y m ode only.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 42 Revision 1.3
Table 4. Port 5 PHY P5-MII/RMII Signals
MII
Signal Description KSZ8895MQX/FQX/ML
P5-MII KSZ8895MQX/FQX/ML
MII Signal Type KSZ8895RQX
P5-RMII
KSZ8895RQX
RMII Signal
Type
MTXEN Transmit enable PMTXEN I PMTXEN I
MTXER Transmit error PMTXER I
MTXD3 Transmit data bit
3 PMTXD[3] I
MTXD2 Transmit data bit
2 PMTXD[2] I
MTXD1 Transmit data bit
1 PMTXD[1] I PMTXD[1] I
MTXD0 Transmit data bit
0 PMTXD[0] I PMTXD[0] I
MTXC Transmit clock PMTXC O PMREFCLK/PMTXC I
MCOL Collision detection PCOL O
MCRS Carrier sense PCRS O
MRXDV Receive data valid PMRXDV O PMRXDV O
MRXER Receive error PMRXER O PMRXER O
MRXD3 Receive data bit 3 PMRXD[3] O
MRXD2 Receive data bit 2 PMRXD[2] O
MRXD1 Receive data bit 1 PMRXD[1] O PMRXD[1] O
MRXD0 Receive data bit 0 PMRXD[0] O PMRXD[0] O
MRXC Receive clock PMRXC O PMRXC O
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 43 Revision 1.3
Port 5 MAC 5 SW5-MII Interfa ce for the KSZ8895MQX/FQX/ML
Table 5 shows two connection manners:
The first is an external MAC connects to SW5-MII PHY mode.
The second is an external PHY connects to SW5-MII MAC mode.
Please see the pin [91, 86, 87] descriptions for configuration details for the MAC mode and PHY mode. SW5-MII
works with 25MHz clock for 100Base-TX, SW5-MII works with 2.5MHz clock for 10Base-T.
Table 5. Switch MAC5 MII Signals
KSZ8895MQX/FQX/ML PHY Mode Connection KSZ8895MQX/FQX/ML MAC Mode Connection
External
MAC KSZ8895MQX/FQX/ML
SW5-MII Signals Type Description External
PHY KSZ8895MQX/FQX/ML
SW5-MII Signals Type
MTXEN SMTXEN Input T r ansmit enable MTXEN SMRXDV Output
MTXER SMTXER Input T r ansmit error MTXER Not used Not used
MTXD3 SMTXD[3] Input Transmit data bit 3 MTXD3 SMRXD[3] Output
MTXD2 SMTXD[2] Input Transmit data bit 2 MTXD2 SMRXD[2] Output
MTXD1 SMTXD[1] Input Transmit data bit 1 MTXD1 SMRXD[1] Output
MTXD0 SMTXD[0] Input Transmit data bit 0 MTXD0 SMRXD[0] Output
MTXC SMTXC Output Transmit cl oc k MTXC SMRXC Input
MCOL SCOL Output Collision detection MCOL SCOL Input
MCRS SCRS Output Carrier sense MCRS SCRS Input
MRXDV SMRXDV Output Receive data valid MRXDV SMTXEN Input
MRXER Not used Output Receive error MRXER SMTXER Input
MRXD3 SMRXD[3] Output Receive data bit 3 MRXD3 SMTXD[3] Input
MRXD2 SMRXD[2] Output Receive data bit 2 MRXD2 SMTXD[2] Input
MRXD1 SMRXD[1] Output Receive data bit 1 MRXD1 SMTXD[1] Input
MRXD0 SMRXD[0] Output Receive dat a bit 0 MRXD0 SMTXD[0] Input
MRXC SMRXC Output Receive clock MRXC SMTXC Input
The switch MII interface operates in either MAC mode or PHY mode for KSZ8895MQX/FQX/ML. These interfaces
are nibble-wide data interfaces, so they run at one-quarter the network bit rate (not encoded). Additional signals on
the transm it side indicate when data is vali d or when an error occurs during tra nsmission. Lik ewise, the rece ive side
has indica tor s th at c on vey when the da ta is valid an d without physical l a yer er rors. For ha lf -dupl ex op er ati on , ther e is
a signal that indicates a collision has occurred during transmission.
Note that the s ignal MR X ER is n ot pro vided o n th e MI I-SW interfac e for PHY m ode operat ion an d t he signa l MT XER
is not provided on the SW-MII interface for MAC mode operation. Normally MRXER would indicate a receive error
coming from the physical layer device. MTXER would indicate a transmit error from the MAC device. These signa ls
are not appropriate for this configuration. For PHY mode operation with an external MAC, if the device interfacing
with the KSZ8 895MQX /FQ X/ML h as an MR XER p in, i t shou ld be tied low. For M AC m ode oper atio n with an ex terna l
PHY, if the device interfacing with the KSZ8895MQX/FQX/ML has an MTXER pin, it should be tied low.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 44 Revision 1.3
Port 5 MAC 5 Switch SW5-RMII Interface for the KSZ8895RQX
The Reduced Media Independent Interface (RMII) specifies a low pin count Media Independent Interface (MII). The
KSZ8895RQX supports RMII interface at Port 5 switch side and provides a common interface at MAC5 layer in the
device, and has the following key characteristics:
Supports 10Mbps and 100Mbps data rates.
Uses a single 50MHz clock reference (provided internally or externally): in internal mode, the chip provides a
refer ence clock fr om the S MRXC p in to t he SMTX C pin and pr ovides the c lock to the oppos ite cloc k input p in for
RMII interf ace. In ex terna l mode, the chip receives 50MHz refer ence cloc k f rom an externa l oscillat or or op posite
RMII interfac e.
Provides independent 2-bit wide (bi-bit) transmit and receive data paths.
KSZ8895RQX supports MAC5 RMII interfaces at the switch side:
For the detail of SW5-RMII (Port 5 MAC5 RMII) signals connection see the table below:
The KSZ8895RQX can pro vide a 50 MHz refer enc e c lo ck for both M AC t o M AC and MAC t o P H Y RMII interfaces
when SW5-RMII is used in the clock mode of the device (default with strap pin LED2_2 internal pull-up for the
clock mode).
The KSZ8895RQX can also rece ive a 50MH z ref erence clock from an external 5 0MHz clock source or opp osite
RMII to SW5-RMII SMTXC pin when the device is set to normal mode (the strap pin LED2_2 is pulled down).
When the device is strapped to normal mode by pin LED2_2 pull-down, the reference clock comes from SMTXC
which will be used as the device’s clock source . The external 25MHz crystal clock from pins X1/X2 will be ignored.
Note: In normal mode, the 50MHz clock from SMTXC will be used as the clock source for whole device. Th e PHY5
PMTXC/PMREFCLK pin can’t be used as the clock source for whole device. The pin of PMTXC/PMREFCLK can
receive the 50MHz clock from PMRXC when the device is strapped to normal mode and an external 50MHz
reference clock comes in from pin SMTXC. In normal mode, the 50MHz clock on pin SMRXC can be disabled by
register, and the PM RX C 50MHz clock can be used when P5-RMII interface is used.
There is a Register 12 bit 6 to monitor the status of the device for the clock mode or normal mode.
When using an external 50MHz clock source as RMII reference clock, the KSZ8895RQX should be set to normal
mode by pulling down its LED2_2 strap-in pin first before power up reset or warm reset. The normal mode of the
KSZ8895RQX device will start to work when it gets the 50MHz reference clock from pin SMTXC/SMREFCLK from an
external 50MHz clock sourc e. For the RMII c onnect ion exam ples, pleas e refer to the application note i ncluded in th e
design kit.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 45 Revision 1.3
Table 6. Port 5 MAC5 SW5-RMII Connection
SW5-RMII MAC to MAC Connection
(‘PHY mode’)
SW5-RMII MAC to PHY Connection
(‘MAC mode’)
External
MAC
KSZ8895RQX
SW5-RMII KSZ8895RQX
SW Signal Type Description External
PHY KSZ8895RQX
SW5-RMII KSZ8895RQX SW
Signal Type
REF_CLK xSMRXC
Output (clock
mode with
50MHz)
(Normal mode
without
connection)
Reference Clock -------- SMTXC/SM
REFCLK
Input (clock comes
from SMRXC in
clock mod e or
external clock in
normal mode)
CRS_DV SMRXDV
/SMCRSDV Output Carier sense/Receive
data valid CRS_DV SMTXEN Input
RXD1 SMRXD[1] Output Receive data bit 1 RXD1 SMTXD[1] Input
RXD0 SMRXD[0] Output Receive data bit 0 RXD0 SMTXD[0] Input
TX_EN SMTXEN Input T ransmit data enable TX_EN SMRXDV
/SMCRSDV Output
TXD1 SMTXD[1] Input Transmit data bit 1 TXD1 SMRXD[1] Output
TXD0 SMTXD[0] Input Transmit data bit 0 TXD0 SMRXD[0] Output
(not used) (not used) Receive error (not used) (not used)
--- SMTXC/SM
REFCLK
Input (clock
comes from
SMRXC in clock
mode or external
clock in no rmal
mode)
Reference Clock REF_CLK SMRXC
Output (clock mod e
with 50MHz)
(Normal mode
without connection)
Note:
5. MAC/PHY mode in RMII is difference with MAC/PHY mode in MII, there is no strap pin and register configuration request in RMII, j us t fo llow
the signals connect i on in the table.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 46 Revision 1.3
SNI Interface Operatio n
The serial network interface (SNI) is compatible with some controllers used for network layer protocol processing.
This interface can be directly connected to these types of devices. The signals are divided into two groups, one for
transmission and the other for reception. The signals involved are described in Table 7.
Table 7. SNI Signals
SNI Signal Description KSZ8895MQX/RQX/FQX/ML
Signal
TXEN Transmit Enable SMTXEN
TXD Serial Transmit Data SMTXD[0]
TXC Transmit Clock SMTXC
COL Co llision Detectio n SCOL
CRS Carrier Sense SMRXDV
RXD Serial Receive Data SMRXD[0]
RXC Receive Clock SMRXC
This inter face is a bit-wide data int erface, so it runs at the ne twork bit rate (not en coded). A n additiona l signa l on the
transmit side indicates when data is valid. Likewise, the receive side has an indicator that shows when the data is
valid.
For half-duplex operation there is a signal that indicates a collision has occurred during transmission.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 47 Revision 1.3
Advanced Functionality
QoS Priority Support
The KSZ8895MQX/RQX/FQX/ML provides Quality of Service (QoS) for applications such as VoIP and video
conferencing. The KSZ8895MQX/RQX/FQX/ML offers one, two, or four priority queues per port by setting the
Registers port control 9 bit 1 and the Registers port control 0 bit 0, the 1/2/4 queues split as follows:
[Registers port control 9 bit 1, control 0 bit 0] = 00 single output queue as default.
[Registers port control 9 bit 1, control 0 bit 0] = 01 egress port can be split into two priority transmit queues.
[Registers port control 9 bit 1, control 0 bit 0] = 10 egress port can be split into four priority transmit queues.
The four priority transmit queue is a new feature in the KSZ8895MQX/RQX/FQX/ML. The queue 3 is the highest
priorit y queue a nd queue 0 is the lo west priorit y queu e. The port Registers xxx control 9 bit 1 and the Registers port
control 0 bit 0 are used to enable split transmit queues for ports 1, 2, 3, 4 and 5, respectively. If a port's transmit
queue is not split, high priority and low priority packets have equal priority in the transmit queue.
There is an additiona l option to either al ways d eliver high pr iority pack ets first or to use progr ammable weigh ted fair
queuing f or the f our prior ity queue s cale b y the Reg isters Por t Contro l 10, 11, 12 and 13 (def ault valu e are 8, 4, 2, 1
by their bit [6:0].
Register 130 bit [7:6] Prio_2Q[1:0] is used when the 2 Queue configuration is selected, these bits are used to map
the 2-bit result of IEEE 802.1p from the Registers 128, 129 or TOS/DiffServ mapping f rom Registers 144-159 (for 4
Queues) into two-queue mode with priority high or low.
Please see the descriptions of the Register 130 bits [7:6] for detail.
Port-Based Priority
With port-based priority, each ingress port is individually classified as a priority 0-3 receiving port. All packets
received at the priorit y 3 r eceiving port are mark ed as high priorit y and ar e sent to the high-priorit y transm it queue if
the corres pondi ng trans m it queue is split . T he Port R egister s Con trol 0 bits [4:3] i s used t o ena ble port-b ase d prior it y
for ports 1, 2, 3, 4 and 5, respectively.
802.1p-Based Priority
For 802.1p-based priority, the KSZ8895MQX/RQX/FQX/ML examines the ingress (incoming) packets to determine
whether they are tagged. If tagged, the 3-bit priority field in the VLAN tag is retrieved and compared against the
“priority mappi ng” va lu e, as specif ied b y the Registers 128 and 129, both Register 128/129 can map 3-bit priority field
of 0-7 value to 2-bit result of 0-3 priority levels. The “priority mapping” value is programmable.
Figure 12 illustrates how the 802.1p priority field is embedded in the 802.1Q VLAN tag.
Figure 12. 802.1p Priority Field Format
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 48 Revision 1.3
802.1p-based priority is enabled by bit [5] of the Registers Port Control 0 for ports 1, 2, 3, 4 and 5, respectively.
The KSZ8895MQX/RQX/FQX/ML provides the option to insert or remove the priority tagged frame's header at each
individual egr ess por t. This header , c onsis ti ng of the t w o-b yte VL AN Protoc o l ID ( V PID) and the two-byte Tag Contr o l
Information field (TCI), is also referred to as the IEEE 802.1Q VLAN tag.
Tag Insertion is enabled by bit [2] of the Registers Port Control 0 and the Register Port Control 8 to select which
source port (ingress port) PVID can be inserted on the egress port for ports 1, 2, 3, 4 and 5, respectively. At the
egress por t, u nta gged pac kets ar e ta gge d w ith the in gres s port ’s def au lt tag. The default ta gs are pr o gr am m ed in th e
Registers Port Control 3 and control 4 for ports 1, 2, 3, 4 and 5, respectively. The KSZ8895MQX/RQX/FQX/ML will
not add tags to already tagged packets.
Tag Removal is enabled by bit [1] of the Registers Port Control 0 for ports 1, 2, 3, 4 and 5, respectively. At the
egress port, tagged packets will have their 802.1Q VLAN tags removed. The KSZ8895MQX/RQX/FQX/ML will not
modify untagged packets.
The CRC is recalculated for both tag insertion and tag removal.
802.1p Priority Field Re-Mapping is a QoS feature that allows the KSZ8895MQX/RQX/FQX/ML to set the “User
Priority Ceiling” at any ingress port by the Register Port Control 2 bit 7. If the ingress packet’s priority field has a
higher priority value than the default tag’s priority field of the ingress port, the packet’s priority field is replaced with
the default tag’s priority field.
DiffServ-B ased Priori ty
DiffServ-based priority uses the ToS Registers (Registers 144 to 159) in the Advanced Control Registers section.
The ToS priority control registers implement a fully decoded, 128-bit Differentiated Services Code Point (DSCP)
register to determine pac ket pri ority from the 6-bit ToS f ield in t he I P h ead er. When the most s ignif ican t s ix bi ts of the
ToS field are fully decoded, 64 code points for DSCP result. These are compared with the corresponding bits in the
DSCP register to determine priority.
Spanning Tree Support
Port 5 is the designated port for spanning tree support.
The other ports (Port 1 Port 4) can be configured in one of the five spanning tree states via “transmit enable,”
“receive enable,” and “learning disable” register settings in Registers 18, 34, 50, and 66 for Ports 1, 2, 3, and 4,
respectively. The following description shows the port setting and software actions taken for each of the five
spanning tree states.
Disable state: the port should not forward or receive any packets. Learning is disabled.
Port setting: "transmit enable = 0, receive enable = 0, learning disable = 1."
Software ac tio n: the pr oces sor s hould n ot sen d an y pack ets to the port. T he switc h m a y stil l send s pecific pa cket s to
the process or (packets that match s ome entries in the static tab le with “overridi ng bit” set) an d the processor should
discard those packets. Note: the processor is co nnected to Port 5 via MII interface. Address learning is disabled on
the port in this state.
Blocking state: only packets to the processor are forwarded. Learning is disabled.
Port setting: "transmit enable = 0, receive enable = 0, learning disable = 1"
Software action: the processor should not send any packets to the port(s) in this state. The processor should
program the “Static MAC table” with the entries that it needs to receive (e.g., BPDU packets). The “overriding” bit
should also be set so that the switch will forward those specific packets to the processor. Address learning is
disabled on the port in this stat e.
Listening state: only packets to and from the processor are forwarded. Learning is disabled.
Port setting: "transmit enable = 0, receive enable = 0, learning disab le = 1.
"Software action: The processor should program the static MAC table with the entries that it needs to receive (e.g.
BPDU packets). The “overriding” bit should be set so that the switch will forward those specific packets to the
processor. The processor may send packets to the port(s) in this state, see the Tail Tagging Mode sub-section for
details. Address learning is disabled on the port in this state.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 49 Revision 1.3
Learning state: only packets to and from the processor are forwarded. Learning is enabled.
Port setting: “transmit enable = 0, receive enable = 0, learning disable = 0.”
Software action: The processor should program the static MAC table with the entries that it needs to receive (e.g.,
BPDU packets). The “overriding” bit should be set so that the switch will forward those specific packets to the
processor. The processor may send packets to the port(s) in this state, see “Tail Tagging Mode” sect ion for details.
Address learning is enabled on the port in this state.
Forwarding state: packets are forwarded and received normally. Learning is enabled.
Port setting: “transmit enable = 1, receive enable = 1, learning disable = 0.”
Software action: The processor should program the static MAC table with the entries that it needs to receive (e.g.,
BPDU packets). The “overriding” bit should be set so that the switch will forward those specific packets to the
processor. The processor may send packets to the port(s) in this state, see “Tail Tagging Mode” section for details.
Address learning is enabled on the port in this state.
Rapid Spanning Tree Support
There are three operational states of Discarding, Learning, and Forwarding assigned to each port for RSTP:
Discarding ports do not participate in the active topology and do not learn MAC addresses.
Discarding state: the state includes three states of the disable, blocking and listening of STP.
Port setting: "transmit enable = 0, receive enable = 0, learning disable = 1."
Software ac tio n: the pr oces sor s hould n ot sen d an y pack ets to the port. The s witc h m ay still sen d spec ific p ack ets t o
the process or (packets that match s ome entries in the static tab le with “overridi ng bit” set) an d the processor should
discard those packets. When disabling the port’s learning capability (learning disable = ’1’), set the Register 1 bit 5
and bit 4 will flush rapidly with the port related entries in the dynamic MAC table and static MAC table.
Note:
The processor is connected to Port 5 via MII interface. Address learning is disabl ed on the port in this state.
Ports in Learning states learn MAC addresses, but do not forward user traffic.
Learning state: only packets to and from the processor are forwarded. Learning is enabled.
Port setting: “transmit enable = 0, receive enable = 0, learning disable = 0.”
Software action: The processor should program the static MAC table with the entries that it needs to receive (e.g.,
BPDU packets). The “overriding” bit should be set so that the switch will forward those specific packets to the
processor. The processor may send packets to the port(s) in this state, see “Tail Tagging Mode” section for details.
Address learning is enabled on the port in this state.
Ports in Forwarding states fully participat e in both data f or warding and MA C lear n i ng.
Forwarding state: packets are forwarded and received normally. Learning is enabled.
Port setting: “transmit enable = 1, receive enable = 1, learning disable = 0.”
Software action: The processor should program the static MAC table with the entries that it needs to receive (e.g.,
BPDU packets). The “overriding” bit should be set so that the switch will forward those specific packets to the
processor. The processor may send packets to the port(s) in this state, see “Tail Tagging Mode” sect ion for details.
Address learning is enabled on the port in this state.
RSTP uses only one type of BPDU called RSTP BPDUs. They are similar to STP Configuration BPDUs with the
exception of a type field set to “version 2” for RSTP and “version 0” for STP, and a flag field carrying additional
information.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 50 Revision 1.3
Tail Tagging Mode
The Tail Tag is only seen and used by the Port 5 interface, which should be connected to a processor by SW5-
MII/RMII interf ace. The one b yte tai l tag gin g is us ed to ind ic ate t he s ourc e/d es tin at ion p ort in Por t 5. Only bit [ 3-0] ar e
used for the destination in the tail tagging byte. Other bits are not used. The Tail Tag feature is enabled by setting
Register 12 bit 1.
Figure 13. Tail Tag Frame Format
Table 8. Tail Tag Rules
Ingress to Port 5 (Host --> KSZ8895MQX/RQX/FQX/ML)
Bit [3:0] Destination
0,0,0,0 Reserved
0,0,0,1 Port 1 (direct forward to Port1)
0,0,1,0 Port 2 (direct forward to Port2)
0,1,0,0 Port 3 (direct forward to Port3)
1,0,0,0 Port 4 (direct forward to Port4)
1,1,1,1 Port 1, 2,3 and 4 (direct forward to Port 1,2,3,4,)
Bit[7:4]
0,0,0,0 Queue 0 is used at destination port
0,0,0,1 Queue 1 is used at destination port
0,0,1,0 Queue 2 is used at destination port
0,0,1,1 Queue 3 is used at destination port
x, 1,x,x Anyhow send packets to specified port in bit [3:0]
1, x,x,x Bit[6:0] will be ignored as nor mal (Addr e ss loo k-up)
Egress from Port 5 (KSZ8895MQX/RQX/FQX/ML --> Host)
Bit [1:0] Source
0,0 Port 1 (packets from Port 1)
0,1 Port 2 (packets from Port 2)
1,0 Port 3 (packets from Port 3)
1,1 Port 4 (packets from Port 4)
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 51 Revision 1.3
IGMP Support
There ar e two parts involv ed to suppor t the Internet Group Man agement Protocol (IGMP) in L ayer 2. The fir st par t is
IGMP snooping, the second part is this IGMP packet to be sent back to the subscribed port. Describe them as
follows.
IGMP Snooping
The KSZ8895MQX/RQX/FQX/ML traps IGMP packets and forwards them only to the processor (Port 5 SW5-
MII/RMII). The IGMP packets are identified as IP packets (either Ethernet IP packets, or IEEE 802.3 SNAP IP
packets) with IP version = 0x4 and protocol version number = 0x2. Set Register 5 bit [6] to ‘1’ to enable IGMP
snooping.
IGMP Send Back to the Subscribed Port
Once the host responds the received IGMP packet, the host should know the original IGMP ingress port and send
back the IGMP packet to this port only; ot herwise this IGMP pack et will be broadcasted t o all port t o downgrade the
performance.
Enable t he ta il ta g m ode, t he hos t w ill k now th e IG MP pack et r eceive d por t f rom tail ta g bits [1: 0] an d ca n se nd back
the response IGMP packet to this subscribed port by setting the bits [3:0] in the tail tag. Enable “Tail tag mode” by
setting Register 12 bit 1.
Port Mirror ing Support
The KSZ8895MQX/RQX/FQX/ML supports “port mirror” comprehensively as:
“Receive Only” Mirror on a Port
All the packets received on the port will b e mir rored on th e sniff er port. For exam ple, Port 1 is progr amm ed to be “r x
sniff,” and Port 5 is programmed to be the “sniffer port.” A pack et, received on Port 1, is destined to Port 4 after the
internal look-up. The KSZ8895MQX/RQX/FQX/ML will forward the packet to both Port 4 and Port 5.
KSZ8895MQX/RQX/FQX/ML can optionally forward even “bad” received packets to Port 5.
“Transmit Only” Mirror on a Port
All the pack ets transmitted on the port will be mirrored on the sniffer port. For exam ple, Port 1 is programmed to be
“tx sniff ,” and Port 5 is progr amm ed to be the “s niff er port.” A pack et, rec eived on any of the p orts, is des tine d to Port
1 after the internal look-up. The KSZ8895MQX/RQX/FQX/ML will forward the packet to both Ports 1 and 5.
“Receive and Transmit” Mirror on Two Ports
All the packets received on port A AND transmitted on port B will be mirrored on the sniffer port. To turn on the “AND”
feature, set Register 5 bit 0 to 1. For example, Port 1 is programmed to be “rx sniff,” Port 2 is programmed to be
“transmit sniff ,” and Port 5 is pr ogrammed to be th e “sniff er port.” A packet, r eceived on Port 1, is destined t o Port 4
after the internal look-up. The KSZ8895MQX/RQX/FQX/ML will forward the packet to Port 4 only, since it does not
meet the “AND” condition. A packet, received on Port 1, is destined to Port 2 after the internal look-up. The
KSZ8895MQX/RQX/FQX/ML will forward the packet to both Port 2 and Port 5.
Multiple ports can be selected to be “rx sniffed” or “tx sniffed.” And an y port can be selected to be the “sniffer port.”
All these per port features can be selected through Register 17.
VLAN Support
The KSZ8895MQX/RQX/FQX/ML supports 128 active VLANs and 4096 possible VIDs specified in IEEE 802.1q.
KSZ8895MQX/RQX/FQX/ML provides a 128-entry VLAN table, which correspond to 4096 possible VIDs and
converts to FID (7 bits) for address look-up max 128 active VLANs. If a non-tagged or null-VID-tagged packet is
received, th en the ingress port VID is used for look-up when 802. 1q is enabled b y the globa l Register 5 co ntrol 3 bit
7. In the VLAN mode, the look-up process starts from VLAN table look-up to determine whether the VID is valid. If
the VID is not valid, the packet will then be dropped and its address will not be learned. If the VID is valid, FID is
retrieved for further look-up by the static MAC table or dynamic MAC table. FID+DA is used to determine the
destination port. Table 9 describes the different actions in different situations of DA and FID+DA in the static MAC
table and dynamic MAC table after the VLAN table finish a look-up action. FID+SA is used for learning purposes.
Table 10 also describes learning in the dynamic MAC table when the VLAN table has done a look-up in the static
MAC table without a val id e ntry.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 52 Revision 1.3
Table 9. FID+DA Look-Up in the VLAN Mode
DA found in
Static MAC table USE FID
Flag? FID Match? DA+FID found in
Dynamic MAC table Action
No Do Not care Do Not care No Broadc ast to the mem bers hip port s defi ned in
the VLAN table bit [11:7].
No Do Not care Do Not care Yes Send to the destination port defined in the
dynamic MAC table bit [58:56].
Yes 0 Do Not care Do Not care Send to the destination port(s) defined in the
static MAC table bit [52:48].
Yes 1 No No Broadcast to the member s hip ports defi ned in
the VLAN table bit [11:7].
Yes 1 No Yes Send to the destination port defined in the
dynamic MAC table bit [58:56].
Yes 1 Yes Do Not care Send to the destination port(s) defined in the
static MAC table bit [52:48].
Table 10. FID+SA Look-Up in the VLAN Mode
SA+FID found in
Dynamic MAC table Action
No The SA+FID will be learned into the dynamic table.
Yes Time stamp will be updated.
Advanced VLAN features are also supported in KSZ8895MQX/RQX/FQX/ML, such as “VLAN ingress filtering” and
“discard non PVID” defined in bits [6:5] of the port Register Control 2. These features can be controlled on a port
basis.
Rate Limiting Support
The KSZ 889 5MQ X /RQ X /FQ X /ML pro v ides a fi ne reso lut ion h ar dware r ate limiting. T he rat e s te p is 64K bps w hen t h e
rate lim it is less tha n 1Mbps rate for 100BT or 10BT . The r ate step is 1M bps when th e rate l imit is m ore than 1M bps
rate for 100BT or 10BT (refer to Data Rate Selection Table which follow the end of the Port Register Queue 0-3
Ingress/Egr ess Lim it Contr ol sect ion). T he rate limit is independent ly on the “rec eive side” an d on th e “tran smit side”
on a per port basis . For 10 BASE-T, a r ate sett ing abo ve 10 Mbps m eans the rate is n ot lim ited. On th e recei ve side,
the data receive rate for each priority at each port can be limited by setting up Ingress Rate Control Registers. On the
transmit side, the data transmit rate for each priority queue at each port can be limited by setting up Egress Rate
Control R egisters . The si ze of eac h fram e has opti ons to include m inim um IFG ( Inter Fram e Gap) or Pream ble byte,
in addition to the data field (from packet DA to FCS).
Ingress Rate Limit
For ingress rate limiting, KSZ8895MQX/RQX/FQX/ML provides options to selectively choose frames from all types,
multicast, broadcast, and flooded unicast frames by bits [3-2] of the port rate limit control register. The
KSZ8895MQX/RQX/FQX/ML counts the data rate from those selected type of frames. Packets are dropped at the
ingress port when the data rate exceeds the specified rate limit or the flow control takes effect without packet
dropped when t he i ngr es s r ate l imit flow con trol is ena ble d by the port rat e limit control register bit 4. The ing res s rate
limiting supports the port-based, 802.1p and DiffServ-based priorities, the port-based priority is fixed priority 0-3
selection by bits [4-3] of the Register Port Control 0. The 802.1p and DiffServ-based priority can be mapped to
priority 0-3 b y default of the Regist er 12 8 and 12 9. In t he ingr ess r ate lim it, set Register 1 35 glo bal contr ol 19 bit 3 to
enable queue-based rate limit if using two-queue or four-queue mode. All related ingress ports and egress port
should be spl it to t w o-qu eu e or four-queue mode by the Reg is ters Port Con tr ol 9 and c ontr o l 0. T he four-que ue mode
will us e Q0-Q3 for pr iority 0-3 by bit [6-0] of the p ort Regist er ingress lim it control 1-4. The two-queue mode will use
Q0-Q1 for pr iority 0-1b y b i t [ 6-0] of the por t Register ingres s limit contr ol 1-2. The priorit y levels in the pac kets of the
802.1p and DiffServ can be programmed to priority 0-3 by the Register 128 and 129 for a re-mapping.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 53 Revision 1.3
Egress Rate Limit
For egres s r a te l imiting, th e Le aky Buc k et algor ithm is app lied t o each output priorit y q ueu e f or s h api ng ou tpu t tr af f ic .
Interfr am e gap is s tr etc hed on a per f r ame base to gen er ate s mooth, non-b urs t eg r ess tr aff ic . The thr oughp ut of eac h
output priority queue is limited by the egress rate specified by the data rate selection table followed the egress rate
limit control registers.
If an y egress queue rec eives mor e traffic than the sp ecified egress rate throughput, p ackets m ay be accum ulated in
the output q ueue and pack et mem ory. After the m emory of the queu e or the port i s used up, pack et dropping or flow
control will b e tr iggered . As a res ult of co ngest ion, t he actual e gres s rate m ay be dom inated b y flo w co ntrol/d roppi ng
at the ingress end, and may be therefore slightly less than the specified egress rate. The egress rate limiting
supports th e port-based, 8 02.1p and D iffServ-bas ed priorities, the port-base d priority is fixed pr iority 0-3 sel ection b y
bits [4-3] of the Register Port Control 0. The 802.1p and DiffServ-based priority can be mapped to priority 0-3 by
default of t he Register 12 8 and 129. In the eg ress rate lim it, s et Register 13 5 global contro l 19 bit 3 for queue-based
rate limit to be enabled if using two-queue or four-queue mode. All related ingress ports and egress port should be
split to two-queue or four-queue m ode by the Registers Port Control 9 and control 0. The f our-queue mode will use
Q0-Q3 for priority 0-3 by bit [6-0] of the port Register egress limit control 1-4. The two-queue mode will use Q0-Q1 for
priority 0-1by b it [ 6 -0] of the port R egister egress limit c ontrol 1-2. The prior ity leve ls in the p ack ets of the 802. 1p an d
DiffServ can be programmed to priorit y 0-3 by the R eg i s ter 128 and 129 for a re-mapping.
W hen the egres s rat e is limited , jus t use one queue per port for the e gress port rat e lim it. T he prior ity pac k ets will be
based upon the data rate selection table (see Tables 13 and 14). If the egress rate lim it uses more than one queue
per port f or the egr es s por t r ate lim it, then the high est priority pack ets will be bas e d upon t he da ta r ate s e lecti on tab l e
for the rate limit exact number. Other lower priority packet rates will be limited based upon 8:4:2:1 (default) priority
ratio, which is based on the highest priority rate. The transmit queue priority ratio is programmable.
To reduce congestion, it is good practice to make sure the egress bandwidth exceeds the ingress bandwidth.
Transmit Queue Ratio Programming
In transm it queues 0-3 of the egres s port, t he d efault p riorit y ratio is 8: 4:2:1. T he p riorit y ratio can b e progr am m ed by
the Registers Port Control 10, 11, 12 and 13. When the transmit rate exceeds the ratio limit in the transmit queue, the
transmit rate will be limited by the transmit queue 0-3 ratio of the Register Port Control 10, 11, 12 and 13. The
highest priority queue will not be limited. Other lower priority queues will be limited based on the transmit queue ratio.
Filtering for Self-Address, Unknown Unicast/Multicast Address and Unknown VID Packet/IP Multicast
Enable Self-addr ess f ilterin g, the unk nown un icast pack et f iltering a nd for ward ing by the Register 13 1 Glob al Control
15. Enable Unknown multicast packet filtering and forwarding by the Register 132 Global Control 16.
Enable Unknown VID pack et filtering and forwar din g by the Regis ter 133 Glo bal Control 17.
Enable Unknown IP multicast packet filtering and forwarding by the Register 134 Global Control 18.
This function is very useful in preventing packets that could degrade the quality of the port in applications such as
voice over Internet Protocol (VoIP) and the daisy chain connection.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 54 Revision 1.3
Configuration Interface
I2C Master Serial Bus Configuration
If a 2-wire EEPROM exists, then the KSZ8895MQX/RQX/FQX/ML can perform more advanced features like
broadcast storm protection and rate control. The EEPROM should have the entire valid configuration data from
Register 0 to Register 255 defined in the “Memory Map,” except the chipID = 0 in the Register1 and the status
registers. After reset, the KSZ8895MQX/RQX/FQX/ML will start to read all 255 registers sequentially from the
EEPROM. The configuration access time (tprgm) is less than 30ms, as shown in Figure 14.
Figure 14. KSZ8895MQX/RQX/FQX/ML EEPROM Configuration Timing Diagram
To configure the KSZ8895MQX/RQX/FQX/ML with a pre-configured EEPROM use the following steps:
1. At the board level, connect Pin 110 on the KSZ8895MQX/RQX/FQX/ML to the SCL pin on the EEPROM.
Connect Pin 111 on the KSZ8895MQX/RQX/FQX/ML to the SDA pin on the EEPROM.
2. A[2-0] address pins of EEPROM should be tied to ground for address A[2-0] = 000to be identified by the
KSZ8895MQX/RQX/FQX/ML.
3. Set the input s igna ls PS[1 :0] ( pins 113 and 1 14, res pec tivel y) to “00 .” T his puts t he KSZ 8895MQ X/RQX /FQ X/ML
serial bus configuration into I2C master mode.
4. Be sure the board-level reset signal is connected to the KSZ8895MQX/RQX/FQX/ML reset signal on Pin115
(RST_N).
5. Program the contents of the EEPROM before placing it on the board with the desired configuration data. Note
that the first byte in the EEPROM must be “95” for the loading to occur properly. If this value is not correct, all
other data will be ignor ed.
6. Place EEPROM on t he board and power up the boar d. Assert th e active-low board level r eset to R ST_N on the
KSZ8895MQX/RQX/FQX/ML. After the reset is de-asserted, the KSZ8895MQX/RQX/FQX/ML will begin reading
configuration data from the EEPROM. The configuration access time (tprgm) is less than 30ms.
Note:
For proper operation, make sure that Pin47 (PWRDN_N) is not asserted during the reset operation.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 55 Revision 1.3
SPI Slave Serial Bus Configuration
The KSZ8 895MQX/ RQX/FQX /ML can also ac t as a SPI slave device. T hrough th e SPI, the e ntire f eature set c an be
enabled, including “VLAN,” “IGMP snooping,” “MIB counters,” etc. The external master device can access any
register from Register 0 to Register 255 randomly. The system should configure all the desired settings before
enabling the switch in the KSZ8895MQX/RQX/FQX/ML. To enable the switch, write a "1" to Register 1 bit 0.
Two standard SPI commands are supported (00000011 for “READ DATA,” and 00000010 for “WRITE DATA”). To
speed configuration time, the KSZ8895MQX/RQX/FQX/ML also supports multiple reads or writes. After a byte is
written to or read f rom the KSZ8895 MQX/RQ X/FQX /ML, the in ternal addres s counter autom aticall y increments if the
SPI Slave Select Signal (SPIS_N) continues to be driven low. If SPIS_N is kept low after the first byte is read, the
next byte at the next address will be shifted out on SPIQ. If SPIS_N is kept low after the first b yte is written, bits on
the Master Out Slav e Input (SP ID) line wil l be written to the nex t address. Asserting SPI S_N high t erminates a re ad
or write operation. This means that the SPIS_N signal must be asserted high and then low again before issuing
another command and address. The address counter wraps back to zero once it reaches the highest address.
Therefore the entire register set can be written to or read from by issuing a single command and address.
The def ault SPI c loc k speed is 12 .5M Hz. The KSZ889 5MQ X /RQ X /F QX /ML is ab l e to sup por t a S PI b us up t o 25MHz
(set Register 12 bit [5:4] = 0x10). A high performance SPI master is recommended to prevent internal counter
overflow.
To use the KSZ8895MQX/RQX/FQX/ML SPI:
1. At the board level, connect KSZ8895MQX/RQX/FQX/ML pins as follows:
Table 11. SPI Connections
KSZ8895MQX/RQX/FQX/ML
Pin Number KSZ8895MQX/RQX/FQX/ML
Signal Name Microprocessor Signal Description
112 SPIS_N SPI Slave Select
110 SPIC SPI Clock
111 SPID Master Out Slave Input
109 SPIQ Master In Slave Output
2. Set the input signals PS[1:0] (pins 113 and 114, respectively) to “10” to set the serial configuration to SPI slave
mode.
3. Power up t he board and asser t a reset sig nal. After r eset wait 100µs, the s tart switc h bit in Re gister 1 will be set
to ‘0’. Configure the desired settings in the KSZ8895MQX/RQX/FQX/ML before setting the start register to ‘1.'
4. W rite configuration to r eg ister s us ing a typical SPI write dat a cycle as s ho wn in Fi gure 15 or SPI multiple wri t e as
shown in Figure 17. Note that data input on SPID is registered on the rising edge of SPIC.
5. Register s can b e rea d and conf iguration c an be verif ied with a t ypical SPI rea d da ta c ycle as s ho wn in Fig ure 16
or a multiple read as shown in Figure 18. Note that read data is registered out of SPIQ on the falling edge of
SPIC.
6. After configuration is written and verified, write a ‘1’ to Register 1 bit 0 to begin KSZ8895MQX/RQX/FQX/ML
switch operation.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 56 Revision 1.3
Figure 15. SPI Write Data Cycle
Figure 16. SPI Read Data Cycle
Figure 17. SPI Multiple Write
SPIQ
SPIC
SPID
SPIS_N
000 0 00 1 1
XA7 A6 A5 A4 A3 A2 A1 A0
D7 D6 D5 D4 D3 D2 D1 D0
READ COMMAND READ ADDRESS READ DATA
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 57 Revision 1.3
Figure 18. SPI Multiple Read
MII Management Interface (M IIM)
The KSZ8895MQX/RQX/FQX/ML supports the standard IEEE 802.3 MII Management Interface, also known as the
Management Data Input/Output (MDIO) Interface. This interface allows upper-layer devices to monitor and control
the states of the KSZ8895MQX/RQX/FQX/ML. An external device with MDC/MDIO capability is used to read the
PHY status or configure the PHY settings. Further details on the MIIM interface are found in Clause 22.2.4.5 of the
IEEE 802.3u Specification.
The MIIM interface consists of the following:
A physical connection that incorporates the data line (Pin108 MDIO) and the clock line (Pin107 MDC).
A specific protocol that operates across the aforementioned physical connection that allows an external controller
to communicate with the KSZ8895MQX/RQX/FQX/ML device.
Access to a set of eight 16-bit registers, c onsisting of 8 standard MIIM Reg isters [0:5h] , 1d and 1f MIIM register s
per port.
The MIIM Interface can operate up to a maximum clock speed of 10MHz MDC clock.
Table 12 depicts the MII Management Interface frame format.
Table 12. MII Management Interface Frame Format
Preamble Start of
Frame Read/Write
OP Code
PHY
Address
Bits[4:0]
REG
Address
Bits[4:0] TA Data Bits[15:0] Idle
Read 32 1’s 01 10 AAAAA RRRRR Z0 DDDDDDDD_DDDDDDDD Z
Write 32 1’s 01 01 AAAAA RRRRR 10 DDDDDDDD_DDDDDDDD Z
The MIIM interface does not have access to all the configuration registers in the KSZ8895MQX/RQX/FQX/ML. It can
only access the standard MIIM registers. See “MIIM Registers. The SPI interface and MDC/MDIO SMI mode, on the
other hand, can be used to access all registers with the entire KSZ8895MQX/RQX/FQX/ML feature set.
SPIQ
SPIC
SPID
SPIS_N
0000001 1X A7 A6 A5 A4 A3 A2 A1 A0
D7 D6 D5 D4 D3 D2 D1 D0
READ COMMAND READ ADDRESS Byte 1
XXXXXXXXXXXXXXXX
Byte 2 Byte 3 ... Byte N
XXXXXXXX
XXXXXXXX
D7 D6 D5 D4 D3 D2 D1 D0
D7 D6 D5 D4 D3 D2 D1 D0 D7 D6 D5 D4 D3 D2 D1 D0
SPIQ
SPIC
SPID
SPIS_N
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 58 Revision 1.3
Serial Management Interface (SMI)
The SMI is the KSZ8895MQX/RQX/FQX/ML non-standard MIIM interface that provides access to all
KSZ8895MQX/RQX/FQX/ML configuration registers. This interface allows an external device with MDC/MDIO
interface to completely monitor and control the states of the KSZ8895MQX/RQX/FQX/ML.
The SMI interface consists of the following:
A physical connection that incorporates the data line (MDIO) and the clock line (MDC).
A specific protocol that operates across the aforementioned physical connection that allows an external controller
to communicate with the KSZ8895MQX/RQX/FQX/ML device.
Access to all KSZ8895MQX/RQX/FQX/ML c onfigurat ion re gister s. R egister ac ces s inclu des t he G loba l, Por t and
Advanced Control Registers 0-255 (0x00 0xFF), and indirect access to the standard MIIM Registers [0:5] and
custom MIIM Registers [29, 31].
The SMI Interface can operate up to a maximum clock speed of 10MHz MDC clock.
Table 13 depicts the SMI frame format.
Table 13. Serial Management Interface (SMI) Frame Format
Preamble Start of
Frame Read/Write
OP Code
PHY
Address
Bits[4:0]
REG
Address
Bits[4:0] TA Data
Bits[15:0] Idle
Read 32 1’s 01 10 RR11R RRRRR Z0 0000_0000_DDDD_DDDD Z
Write 32 1’s 01 01 RR11R RRRRR 10 xxxx_xxxx_DDDD_DDDD Z
SMI register Read access is selected when OP Code is set to “10” and bits [2:1] of the PHY address is set to ‘11’.
The 8-bit register address is the concatenation of {PHY address bits [4:3], PHY address bits [0], REG address bit
[4:0]}. TA is turn-around bits. TA bits [1:0] are ’Z0’ means the processor MDIO pin is changed to input Hi-Z from
output mode and the followed ‘0’ is the read response from device, as the switch configuration registers are 8-bit
wide, only the lower 8 bits of data bits [15:0] are used
SMI register Write access is selected when OP Code is set to “01and bits [2:1] of the PHY address is set to ‘11’.
The 8-bit register address is the concatenation of {PHY address bits [4:3], PHY address bits [0], REG address bit
[4:0]}. TA bits [1:0] are set to 10’, as the switch configuration registers are 8-bit wi de, only the lower 8 bits of data bits
[15:0] are used.
To access the KSZ8895MQX/RQX/FQX/ML Registers 0-255 (0x00 - 0xFF), the following applies:
PHYAD [4, 3, 0] and REGAD [4:0] are concatenated to form the 8-bit address; that is, {PHYAD [4, 3, 0], REGAD
[4:0]} = bits [7:0] of the 8-bit address.
Register s are 8 data b its wi de. For read op erat ion, dat a bits [15: 8] are rea d back as zeroes. F or write o perat ion, dat a
bits [15:8] are not defined, and hence can be set to either zeroes or ones.
SMI reg ister ac cess is t he s ame as t he MIIM r egister acces s, except f or the regi ster acces s requir ements p resented
in this section.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 59 Revision 1.3
Register Descriptions
Offset
Decimal
Hex
Description
0-1 0x00-0x01 Chip ID Registers.
2-13 0x02-0x0D Global Control Registers.
14-15 0x0E-0x0F Power Down Management Control Registers.
16-20 0x10-0x14 Port 1 Control Registers.
21-23 0x15-0x17 Port 1 Reserved (Factory Test Registers).
24-31 0x18-0x1F Port 1 Control/Status Registers.
32-36 0x20-0x24 Port 2 Control Registers.
37-39 0x25-0x27 Port 2 Reserved (Factory Test Registers).
40-47 0x28-0x2F Port 2 Control/Status Registers.
48-52 0x30-0x34 Port 3 Control Registers.
53-55 0x35-0x37 Port 3 Reserved (Factory Test Registers).
56-63 0x38-0x3F Port 3 Control/Status Registers.
64-68 0x40-0x44 Port 4 Control Registers.
69-71 0x45-0x47 Port 4 Reserved (Factory Test Registers).
72-79 0x48-0x4F Port 4 Control/Status Registers.
80-84 0x50-0x54 Port 5 Control Registers.
85-87 0x55-0x57 Port 5 Reserved (Factory Test Registers).
88-95 0x58-0x5F Port 5 Control/Status Registers.
96-103 0x60-0x67 Reserved (Factory Testing Registers).
104-109 0x68-0x6D MAC Address Registers.
110-111 0x6E-0x6F Indirect Access Control Registers.
112-120 0x70-0x78 Indirect Data Registers.
121-123 0x79-0x7B Reserved (Factory Testing Registers).
124-125 0x7C-0x7D Port Interrupt Registers.
126-127 0x7E-0x7F Reserved (Factory Testing Registers).
128-135 0x80-0x87 Global Control Registers.
136 0x88 Switch Self Test Control Register.
137-143 0x89-0x8F QM Global Control Registers.
144-145 0x90-0x91 TOS Priority Control Registers.
146-159 0x92-0x9F TOS Priority Control Registers.
160-175 0xA0-0xAF Reserved (Factory Testing Registers).
176-190 0xB0-0xBE Port 1 Control Registers.
191 0xBF Reserved (Factory Testing Register): Transmit Queue Remap Base Register.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 60 Revision 1.3
Register Descriptions (Continued)
Offset
Decimal Hex Description
192-206 0xC0-0xCE Port 2 Control Registers.
207 0xCF Reserved (Factory Testing Register).
208-222 0xD0-0xDE Port 3 Control Registers.
223 0xDF Reserved (Factory Testing Register).
224-238 0xE0-0xEE Port 4 Control Registers.
239 0xEF Reserved (Factory Testing Register).
240-254 0xF0-0xFE Port 5 Control Registers.
255 0xFF Reserved (Factory Testing Register).
Global Registers
Address Name Description Mode Default
Register 0 (0x00): Chip ID0
7-0 Family ID Ch ip family . RO 0x95
Register 1 (0x01): Chip ID1 / Start Switch
7-4 Chip ID 0100 = KSZ8895MQX/FQX/ML
0110 = KSZ8995RQX RO 0x4 is for MQX,
FQX, and ML
0x6 is for RQX
3-1 Revision ID Revisi on ID RO 0x0
0 Start Switch
1, Start the chip when external pins (PS1, PS0) = (1,0)
Note: i n (PS1,PS0) = (0,0) mode, the chip will
start autom aticall y, after t rying to read the external
EEPROM. If EEPROM does not exist, t he chip will use default
values for all internal regist ers. If EEPROM is present, t he
contents in the EEPROM will be checked.
The switch will check:
(1) Register 0 = 0x95.
(2) Register 1 [7:4] = 0x0.
If this check is OK , the c ontents i n the EEPROM will override
chip register default values =0, chip will not st art when
external pins
(PS1, PS0) = (1,0) or (0,1).
Note: (PS1, PS0) = (1,1) for Factory test only.
0, stop the switch function of the chip.
R/W
0
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 61 Revision 1.3
Global Registers (Continued)
Address Name Description Mode Default
Registe r 2 (0x02): Global Control 0
7 New Back-off Enable New Back-off algorithm designed for UNH
1 = Enable
0 = Disable R/W 0
6 Reserved Reserved. RO 0
5 Flush dynamic MAC table
Flush the entire dynamic MAC table for RSTP
1 = Trigger the flush dynamic MAC table operation.
This bit is self-clear
0 = normal operation
Note: Al l the entries ass ociated with a port that has its
learning capabil ity bei ng turned off (Learning Di s abl e) will be
flushed. If you want to flush the entire Table, all ports learni ng
capability must be turned off.
R/W
(SC) 0
4 Flush static MAC table
Flush the matched entries in static MAC table for RSTP
1 = Trigger the flush static MAC table operation. This
bit is self-clear
0 = normal operation
Note: The matched entry is defined as the entry whose
Forwarding Ports field contains a single port and MAC
address with unicast. This port, in turn, has its learning
capability being turned off (Learning Disable). Per port,
multiple entries can be qualified as matched entries.
R/W
(SC) 0
3 Enable PHY MII/RMII
1, enable PHY P5-MII/RMII interface (default).
Note: if not enabled, the switch will be tri-state all
outputs.
R/W
1
Pin LED[5][1]
strap option.
PD(0): isolate.
PU(1): Enable.
Note:
LED[5][1]
has internal
pull-up (PU).
2 Reserved N/A, do not change RO 1
1 UNH Mode
1, the switch will drop packets with 0x8808 in T/L filed,
or DA = 01-80-C2-00-00-01.
0, the switch will drop packets qualified as “flow control”
packets.
R/W 0
0 Link Change Age
1, link change from “link” to “no link” will cause fast
aging (<800µs) to age address table faster. After an
age cycle is complete, the age logic will return to
normal (300 +/- 75 second s).
Note: If any port is unplugged, all addresses will be
automatically aged out.
R/W 0
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 62 Revision 1.3
Global Registers (Continued)
Address Name Description Mode Default
Registe r 3 (0x03): Global Control 1
7 Pass All Frames 1, sw itch all pa cket s includ ing bad ones . Use d solely
for debugging purpose. Works in conjunction with
sniffer mode. R/W 0
6 2K Byte packet support 1 = enable support 2K Byte packet
0 = disable sup port 2K Byte pack et R/W 0
5 IEEE 802.3x Transmit
Flow Control Disable
0, will enable transmit flow control based on AN result.
1, will not enable transmit flow control regardless of
AN result. R/W
0
Pin PMRXD3
strap option.
PD(0): Enable Tx
flow control
(default).
PU(1): Disable
Tx/Rx flow
control.
Note: PMRXD3
has internal
pull-down.
4 IEEE 802.3x Receive
Flow Control Disable
0, will enable receive flow control based on AN result.
1, will not enable receive flow control regardless of AN
result.
Note: Bit 5 and bit 4 default values are controlled by the same
pin, but they can be programmed independently.
R/W
0
Pin PMRXD3
strap option.
PD (0): Enable
Rx flow control
(default).
PU(1): Disable
Tx/Rx flow
control.
Note: PMRXD3
has internal
pull-down.
3 Frame Length Fiel d
Check
1, will check frame length field in the IEEE packets
If the actual length doe s not match, the packet will be
dropped (for L/T <1500). R/W 0
2 Aging Enable 1, Enab le age func tion in the chip.
0, Disable aging function. R/W
1
Pin LED[5][2]
strap option.
PD(0): Aging
disable.
PU(1): Aging
enable (default).
Note: LED[5][2]
has internal pull
up.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 63 Revision 1.3
Global Registers (Continued)
Address Name Description Mode Default
1 Fast age Enable 1 = Turn on fast age (800µs). R/W 0
0 Aggressive Back Off
Enable
1 = Enable more aggressive back-off algorithm in half
duplex mode to enhance performance. This is not an
IEEE standard. R/W
0
Pin PMRXD0
strap option.
PD(0): Disable
aggressive ba ck
off (default).
PU(1):
Aggressive back
off.
Note: PMRXD0
has internal pull
down.
Registe r 4 (0x04): Global Control 2
7 Unicast Port-VLAN
Mismatch Discard
This feature is used for port VLAN (described in
Register 17, Register 33...).
1, all packets cannot cross VLAN boundary.
0, unicast packets (excluding unknown/
multicast/ br oad ca st) can cro ss VLAN boundary .
R/W 1
6 Multicast Storm
Protection Disable
1, “Broadcast Storm Protection” does not include
multicast packets. Only DA = FFFFFFFF FFFF pac kets
will be regulated.
0, “Broadcast Storm Protection” includes
DA = FFFFFFFFFFFF and DA[40] = 1 packet.
R/W 1
5 Back Pressure Mode 1, carrier sen se based bac kpressure is sele cte d.
0, collision based backpressure is selected. R/W 1
4 Flow Control and Back
Pressure fair Mode
1, fair mode is selected. In this mode, if a flow control
port and a non-flow control port talk to the same
destination por t, then packets from the n on-flow control
port may be dropped. This is to prevent the flow control
port from being flow controlled for an extended period
of time.
0, in this mode, if a flow control port and a non-flow
control port talk to the same destination port, the flow
control port will be flow controlled. This may not be
“fair” to the flow control port.
R/W 1
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 64 Revision 1.3
Global Registers (Continued)
Address Name Description Mode Default
3 No Excessive Collision
Drop
1, the switch will not drop packets when 16 or more
collisions occur.
0, the switch will drop packet s when 16 or more
collisions occur.
R/W
0
Pin PMRXD1 strap
option.
PD(0): (default ) Drop
excessive collision
packets. PU(1): Do
Not drop excessive
collision pac ket s.
Note: PMRXD1 has
internal pull -down.
2 Huge Packet Support
1, will accept packet sizes up to 1916 bytes (inclusive).
This bit setting will override setting from bit 1 of the
same register.
0, the max packet size will be determined by bit 1 of this
register.
R/W 0
1 Legal Maximum Packet
Size Check Disable
1, will accept packet sizes up to 1536 bytes (inclusive).
0, 1522 bytes for tagged packets (not including packets
with STPID from CPU to ports 1-4), 1518 bytes for
untagged packets. Any packets larger than the
specified value will be dropped.
R/W
0
Pin PMRXER strap
option.
PD(0): (default)
1518/1522 byte
packets.
PU(1): 1536 byte
packets.
Note: PMRXER has
internal pull -down.
0 Reserved N/A RO 0
Registe r 5 (0x05): Global Control 3
7 802.1q VLAN Enable 1, 802.1q VLAN mode is turned on. VLAN table needs
to set up before the operation.
0, 802.1q VLAN is disabled. R/W 0
6 IGMP Snoop Enable
on Switch SW5-
MII/RMII Interface
1, IGMP snoop enabled. All the IGMP packets will be
forwarded to Switch MII/RMII port.
0, IGMP snoop disabled. R/W 0
5 Enable Direct Mode on
Switch SW5-MII/RMII
Interface
1, direct mode on Port 5. This is a special mode for the
Switch MII/RMII interface. Using preamble before
MRXDV to direct switch to forward packets, bypassing
internal look-up.
0, normal operation.
R/W 0
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 65 Revision 1.3
Global Registers (Continued)
Address Name Description Mode Default
4 Enable Pre-Tag on
Switch SW5-MII/RMIII
Interface
1, packets forwarded to Switch MII/RMII interface will
be pre-tagged with the source port number (preamble
before MRXDV).
0, normal operation.
R/W 0
3-2 Reserved N/A RO 00
1 Enable “Tag” Mask
1, the last 5 digits in the VID field are used as a mask to
determine which port(s) the packet should be forwarded
to.
0, no tag masks.
Note: you need to turn off the 802.1q VLAN mode (reg0x5, bit
7 = 0) for this bit to work
R/W 0
0 Sniff Mode Select
1, will do Rx AND Tx sniff (both source port and
destination por t need to match ) .
0, will do Rx OR Tx sniff (Either source port or
destination por t need s to matc h).
This is the mode used to implement Rx only sniff.
R/W 0
Register 6 (0x06): Global Control 4
7 Switch SW5-MII/RMII
Back Pressure Enable
1, enable half-duplex back pressur e on switch MII/RMII
interface.
0, disable back pressure on switch MII interface. R/W 0
6 Switch SW5-MII/RMII
Half-Duplex Mode 1, enable MII/RMII interface half-duplex mode.
0, enable MII/RMII interface full-duplex mode. R/W
0
Pin SMRXD2
strap option.
PD(0): (default)
Full-duplex
mode.
PU(1): Half-
duplex mode.
Note: SMRXD2
has internal
pull-down.
5 Switch SW5-MII/RMII
Flow Control Enable
1, enable full-duplex flow control on switch MII/RMII
interface.
0, disable full-duplex flow control on switch MII/RMII
interface.
R/W
0
Pin SMRXD3
strap option.
PD(0): (default)
Disable flow
control.
PU(1): enable
flow control.
Note: SMRXD3
has internal
pull-down.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 66 Revision 1.3
Global Registers (Continued)
Address Name Description Mode Default
4 Switch SW5-MII/RMII
Speed 1, the switch SW5-MII/RMII is in 10Mbps mode.
0, the switch SW5-MII/RMII is in 100Mbps mode. R/W
0
Pin SMRXD1
strap option.
PD(0): (default)
Enable 100Mbps.
PU(1): Enable
10Mbps.
Note: SMRXD1
has internal
pull-down.
3 Null VID Replacement 1, will replace null VID with port VID (12 bits).
0, no replacement for null VID. R/W 0
2-0 Broadcast Storm
Protection Rate Bit[10:8]
This along with the next register determines how many
“64 byte blocks” of packet data allowed on an input port
in a preset period. The period is 50ms for 100BT or
500ms for 10BT. The default is 1%.
R/W 000
Registe r 7 (0x07): Global Control 5
7-0 Broadcast Storm
Protection Rate Bit[7:0]
This along with the previous register determines how
many “64-byte blocks” of packet data are allowed on an
input port in a preset period. The period is 50ms for
100BT or 500ms for 10BT. The default is 1%.
R/W 0x4A(6)
Registe r 8 (0x08): Global Control 6
7-0 Factory Testing N/A, do not change RO 0x00
Registe r 9 (0x09): Global Control 7
7-0 Factory Testing N/A, do not change RO 0x4C
Note:
6. 148,800 fram es/s ec × 50ms/interval × 1% = 74 frames/interval (approx.) = 0x4A.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 67 Revision 1.3
Global Registers (Continued)
Address Name Description Mode Default
Registe r 1 0 (0x0A): Global Control 8
7-0 Factory Testing N/A, do not change RO 0x00
Registe r 1 1 (0x0B): Global Control 9
7 Reversed N/A, do not change RO 0
6 Port 5 SW5- RMII
reference clo ck edge
select
RQX: Select the data sampling edge of Switch MAC5
SW5- RMII reference clock:
1 = data sampling on negative edge of refclk
0 = data sampling on positive edge of refclk (default)
Note: MQX/FQX/ML is reserved with read only for this bit.
R/W 0
5 Reserved N/A, do not change RO 0
4 Reserved N/A, do not change RO 0
3 PHY Power
Save 1 = disable PHY power save mode.
0 = enable PHY power save mode. R/W 0
2 Reserved N/A, do not change RO 0
1 LED Mode
0 = led mode 0.
1 = led mode 1.
Mode 0, link at
100/Full LEDx[2,1,0] = 0,0,0
100/Half LEDx[2,1,0] = 0,1,0
10/Full LEDx[2,1,0] = 0,0,1
10/Half LEDx[2,1,0] = 0,1,1
Mode 1, link at
100/Full LEDx[2,1,0] = 0,1,0
100/Half LEDx[2,1,0] = 0,1,1
10/Full LEDx[2,1,0] = 1,0,0
10/Half LEDx[2,1,0] = 1,0,1
(0 = LED on, 1 = LED off)
R/W
0
Pin SMRXD0
strap option.
Pull-down(0):
Enabled led
mode 0.
Pull-up(1):
Enabled led
mode 1.
Note: SMRXD0
has internal
pull-down 0.
Mode 0 Mode 1
LEDX_2 Lnk/Act 100Lnk/Act
LEDX_1 Fulld/Col 10Lnk/Act
LEDX_0 Speed Fulld
0 SPI/SMI read sampling
clock edge select
Select the SPI/SMI clock edge for sampling SPI/SMI
read data.
1 = trigger by rising edge of SPI/SMI clock (for high
speed SPI about 25MHz and SMI about 10MHz)
0 = trigger by falling edge of SPI/SMI clock.
R/W 0
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 68 Revision 1.3
Global Registers (Continued)
Address Name Description Mode Default
Register 12 (0x0C): Global Control 10
7 Reserved Reserved RO 0
6
Status of device with RMII
interface at clo ck mode or
normal mode, default is
clock mod e w ith 25MHz
Crystal clock from pins
X1/X2
(used for RMII of the
KSZ8895RQX only)
1 = The device is in clock mode when use RMII
interface, 25 MHz Crystal clock input as clock source
for internal PLL. This internal PLL will provide the 50
MHz output on the pin SMRX C for RMII reference
cl ock (Default) .
0 = The device is in normal mode when use SW4-RMII
interface and 50 MHz clock input from external clock
through pin SM4TXC as device’s clock source and
internal PLL clock source from this pin not from the
25MHz crystal.
Note: T his bit is set by strap option only. Write t o this bit has
no effect on mode selection.
Note: T he normal mode is used in SW5-RMII interface
reference clock from external.
RO
1
Pin LED[2][2]
strap option.
PD(0): Select
SW5-RMII at
normal mode to
receive ex ter nal
50MHz RMII
reference clo ck
PU(1): (default)
Select SW5-
RMII at clock
mode, RMII
output 50MHz
Note: LED[2][2]
has internal
pull-up.
5 – 4 CPU interface clock select
Select the internal clock speed for SPI, MDI interface:
00 = 41.67MHz (SPI up to 6.25MHz, MDC up to
6MHz)
01 = 83.33MHz Default (SPI SCL up to 12.5MHz,
MDC up to 12MHz)
10 = 125MHz (for high speed SPI about 25MHz)
11 = Reserved
R/W 01
3 Reserved N/A, do not change RO 0
2 Enable restore preamble
This bit is to enable PHY5, when in 10BT mode, to
restore preamble before sending data on P5-MII
interface.
1 = Enable PHY5 to restore preamble.
0 = Disable PHY5 to restore preamble.
R/W 1
1 Tail Tag Enable Tail Tag feature is applied for Port 5 only.
1 = Insert 1 Byte of data right before FCS.
0 = Do not insert. R/W 0
0 Pass Flow Control Packet 1 = Switch will not filter 802.1x “flow control” packets.
0 = Switch will filter 802.1x “flow control” packets. R/W 0
Register 13 (0x0D): Global Control 11
7 – 0 Factory Testing N/A, do not change RO 00000000
Register 14 (0x0E): Power-Down Managemen t Control 1
7 Reserved N/A, do not change RO 0
6 Reserved N/A, do not change RO 0
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 69 Revision 1.3
Global Registers (Continued)
Address Name Description Mode Default
5 PLL Power Down Pll power down enable:
1 = Enable
0 = Disable R/W 0
4 – 3 Power Management Mode
Power management mode :
00 = Normal mode (D0)
01 = Energy Detection mode (D2)
10 = soft Power Down mode (D3)
11 = Power Saving mode (D1)
Note: For soft Power Down mode to take effect, have
to write 10only without read value back.
R/W
00
Pin LED[4][0]
strap option.
PD(0): Select
Energy detection
mode
PU(1): (default)
Normal mode
Note: LED[4][0]
has internal
pull-up.
2-0 Reserved N/A, do not change RO 000
Register 15 (0x0F): Power-Down Management Control 2
7 – 0 Go_sleep_time[7:0]
When the Energy Detect mode is on, this value is
used to control the minimu m period t hat the no energy
event has to be detected consecutively before the
device enters the low power state. The unit is 20ms.
The default of go_sleep time is 1.6 seconds (80Dec x
20ms).
R/W 01010000
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 70 Revision 1.3
Port Re gisters
The following registers are used to enable features that are assigned on a per port basis. The register bit
assignments are the same for all ports, but the address for each port is different, as indicated.
Registe r 1 6 (0x10): Port 1 Control 0
Registe r 3 2 (0x20): Port 2 Control 0
Registe r 4 8 (0x30): Port 3 Control 0
Registe r 6 4 (0x40): Port 4 Control 0
Registe r 8 0 (0x50): Port 5 Control 0
Address Name Description Mode Default
7 Broadcast Storm
Protection Enable
1, enable broadcast storm protection for ingress
packets on the port.
0, disable broadcast storm protection. R/W 0
6 DiffServ Priority
Classification Enable
1, enable DiffServ priority cla s sifi cat ion for ingress
packets on port.
0, disable DiffServ function. R/W 0
5 802.1p Priority
Classification Enable
1, enable 802.1p priority classification for ingress
packets on port.
0, disable 802.1p. R/W 0
4 – 3 Port-Based Priority
Classification Enable
= 00, ingress packets on port will be
classified as priority 0 queue if “Diffserv” or “802.1p”
cl assification is not enabled or fails to classify.
= 01, ingress packets on port will be
cl assified as pr iori ty 1 queue if “Diffserv” or “802.1p”
cl assification is not enabled or fails to classify.
= 10, ingress packets on port will be
classified as priority 2 queue if “Diffserv” or “802.1p”
cl assification is not enabled or fails to classify.
= 11, ingress packets on port w ill be
classified as priority 3 queue if “Diffserv” or “802.1p”
cl assification is not enabled or fails to classify.
Note: “Diff Serv”, “802.1p” and port priority can be
enabled at the same time. The OR’ed result of 802.1p
and DSCP overwrites the port priority.
R/W 00
2 Tag insertion
1, when packets are output on the port, the switch will
add 802.1q tags to packets without 802.1q tags when
received. The switch will not add tags to packets
already tagged. The tag inserted is the ingr ess port’s
“port VID.”
0, disable tag insertion.
R/W 0
1 Tag Removal
1, when packets are output on the port, the switch will
remove 802.1q tags from packets with 802.1q tags
when received. The switch will not modify packets
received without tags.
0, disable tag removal.
R/W 0
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 71 Revision 1.3
Port Re gisters (Continued)
Address Name Description Mode Default
0 Two Queues Split Enable
This bit 0 in the Register16/32/48/64/80 should be in
combination with Register177/193/209/225/241 bit 1
for Port 1-5 will sele ct the spl it of ½/4 queues:
For Port 1, [Register 177 bit 1, Register 16 bit 0] =
[11], Reserved
[10], the port output queue is split into four prior ity
queues or if map 802.1p to priority 0-3 mod e.
[01], the port output queue is split into two priority
queues or if map 802.1p to priority 0-3 mod e.
[00], single output queue on the port. There is no
priority differentiation even though packets are
classified into high or low priority.
R/W 0
Registe r 1 7 (0x11): Port 1 Control 1
Registe r 3 3 (0x21): Port 2 Control 1
Registe r 4 9 (0x31): Port 3 Control 1
Registe r 6 5 (0x41): Port 4 Control 1
Registe r 8 1 (0x51): Port 5 Control 1
Address Name Description Mode Default
7 Sniffer Port 1, port is designated as sniffer port and will transmit
packets that are monitored.
0, port is a normal port. R/W 0
6 Receive Sniff
1, all the packets received on the port will be marked
as “monitored packets” and forwarded to the
designated “sniffer port.”
0, no receive monitoring.
R/W 0
5 Transmit Sniff
1, all the packets transmitted on the port will be marked
as “monitored packets” and forwarded to the
designated “sniffer port.”
0, no transmit monitoring.
R/W 0
4-0 Port VLAN Membership
Define the port’s Port VLAN membership. Bit 4 stands
for Port 5, bit 3 for Port 4...bit 0 for Port 1. The port can
only communicate within the membership. A ‘1
includes a port in the member ship , a ‘0’ excludes a port
from membership .
R/W 0x1f
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 72 Revision 1.3
Port Re gisters (Continued)
Registe r 1 8 (0x12): Port 1 Control 2
Registe r 3 4 (0x22): Port 2 Control 2
Registe r 5 0 (0x32): Port 3 Control 2
Registe r 6 6 (0x42): Port 4 Control 2
Registe r 8 2 (0x52): Port 5 Control 2
Address Name Description Mode Default
7 User Priority
Ceiling
1, If packet ‘s “user priority field” is greater than the
“user priority field” in the port default tag register,
replace the packet’s “user priority field” with the “user
priority fiel d” in the port defa ult tag Register control 3.
0, no replace packets priority filed with port default tag
priority filed of the Register Port Control 3 bit [7:5].
R/W 0
6 Ingress VLAN
Filtering.
1, the switch will discard packets whose VID port
membership in VLAN table bit [11:7] does not include
the ingress port.
0, no ingress VLAN filtering.
R/W 0
5 Discard Non-
PVID packets
1, the switch will discard packets whose VID does not
match ingress port default VID.
0, no packets will be discarded. R/W 0
4 Force Flow
Control
1, will always enable Rx and Tx flow control on the port,
regardless of AN result.
0, the flow control is enabled based on AN result
(Default)
R/W
0
Strap-in option
LED1_1/PCOL For port
3/port 4 LED1_1 default
Pull up (1): Not force flow
control;
PCOL default Pull-down
(0): Not force flow
control. LED1_1 Pull
down (0): Force flow
control; PCOL Pull-up
(1): Force flow control.
Note: LED1_1 has
internal pull -up; PCOL
have internal pull-down.
3 Back Pressure
Enable 1, enable port half-duplex back pressure.
0, disable port half-duplex back pressure. R/W
Pin PMRXD2 strap
option.
Pull-down (0): disable
back pressure.
Pull-up(1): enable back
pressure.
Note: PMR XD2 has
internal pull -down.
2 Transmit Enable 1, enable packet transmission on the port.
0, disable packet transmission on the port. R/W 1
1 Receive Enable 1, enable packet reception on the port.
0, disable packet reception on the port. R/W 1
Note:
Bits 2-0 are used for spanning tree support. See “Spanning Tree Support” secti on.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 73 Revision 1.3
Port Re gisters (Continued)
Address Name Description Mode Default
0 Learning Disable 1, disab le sw itch addre ss lear ning cap abi lit y .
0, enable switch address learning. R/W 0
Registe r 1 9 (0x13): Port 1 Control 3
Registe r 3 5 (0x23): Port 2 Control 3
Registe r 5 1 (0x33): Port 3 Control 3
Registe r 6 7 (0x43): Port 4 Control 3
Registe r 8 3 (0x53): Port 5 Control 3
Address Name Description Mode Default
7-0 Default Tag [15:8]
Port’s default tag, co nt ai ning :
7-5: user priority bits
4: CFI bit
3-0 : VID[11:8]
R/W 0
Registe r 2 0 (0x14): Port 1 Control 4
Registe r 3 6 (0x24): Port 2 Control 4
Registe r 5 2 (0x34): Port 3 Control 4
Register 68 (0x44): Port 4 Control 4
Registe r 8 4 (0x54): Port 5 Control 4
Address Name Description Mode Default
7-0 Default Tag [7:0] Default port 1’s tag, containing:
7-0: VID[7:0] R/W 1
Note:
Registers 19 and 20 (and those corresponding to other ports) serve two purposes: (1) Associat ed with the ingress untagged pack ets, and used for
egress tagging; (2) Default VID for the i ngress untagged or null-VID-tagged packets, and used for address look up.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 74 Revision 1.3
Port Re gisters (Continued)
Register 87 (0x57): RMII Management Control Register
Address Name Description Mode Default
7 - 4 Reserved N/A, do not change RO 0000
3
Port 5 SW5-RMII 50MHz
clock output disable
(used for KSZ8895RQX
only)
Disable the output of port 5 SW5-RMII 50 MHz output
clock on RXC pin when 50MHz clock is not being used
by the device and the 50MHz clock from external
oscillator or opposite device in RMII mode
1 = Disable clock output when RXC pin is not used in
RMII mode
0 = Enable clock output in RMII mode
Note: MQX/FQX/ML is reserved wit h read onl y for this bit.
R/W 0
2
P5-RMII 50MHz clock
output disable
(used for KSZ8895RQX
only)
Disable the output of port 5 P5-RMII 50 MHz output
clock on RXC pin when 50MHz clock is not being used
by the device and the 50MHz clock from external
oscillator or opposite device in RMII mode
1 = Disable clock output when RXC pin is not used in
RMII mode
0 = Enable clock output in RMII mode
Note: MQX/FQX/ML is reserved wit h read onl y for this bit.
R/W 0
1 - 0 Reserved N/A, do not change RO 00
Register 25 (0x19): Port 1 Status 0
Register 41 (0x29): Port 2 Status 0
Register 57 (0x39): Port 3 Status 0
Register 73 (0x49): Port 4 Status 0
Register 89 (0x59): Port 5 Status 0
Address Name Description Mode Default
7 Hp_mdix 1 = HP Auto MDI/MDI-X mode
0 = Micrel Auto MDI/MDI-X mode R/W 1
6 Factory Testing N/A, do not change RO 0
5 Polrvs 1 = Polarity is reversed
0 = Polarity is not reversed RO 0
4 Transmit Flow Control
Enable 1 = Transmit flow control feature is active
0 = Transmit flow control f eature is inactive RO 0
3 Receive Flow Control
Enable 1 = Receive flow control feature is active
0 = Receive flow control feature is inactive RO 0
2 Operation Speed 1 = Link speed is 100Mbps
0 = Link speed is 10Mbps RO 0
1 Operation Duplex 1 = Link duplex is full
0 = Link duplex is half RO 0
0 Reserved N/A, do not change RO 0
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 75 Revision 1.3
Port Re gisters (Continued)
Register 26 (0x1A): Port 1 PHY Special Control/Status
Register 42 (0x2A): Port 2 PHY Special Control/Status
Register 58 (0x3A): Port 3 PHY Special Control/Status
Register 74 (0x4A): Port 4 PHY Special Control/Status
Register 90 (0x5A): Port 5 PHY Special Control/Status
Address Name Description Mode Default
7 Vct 10M Short 1 = less than 10 meter short detected RO 0
6 - 5 Vct_result
00 = Normal condition
01 = Open condition detected in cable
10 = Short condition detected in cable
11 = Cable diagnostic test has failed
RO 00
4 Vct_enable
1 = Enable cable diagnostic test. After VCT test has
completed, this bit will be self-cleared.
0 = Indicate cable diagnostic test (if enabled) has
completed and the status information is valid for read.
R/W
(SC) 0
3 Force_lnk 1 = Force link pass
0 = Normal Operation R/W 0
2 Pwrsave 1 = Enable power saving
0 = Disable power saving R/W 0
1 Remote Loopback
1 = Perform Remote loopback, loopback on port 1 as
follows:
Port 1 (reg. 26, bit 1 = ‘1’)
Start : RXP1/RXM1 (port 1)
Loopback: PMD/PMA of port 1’s PHY
End: TXP1/TXM1 (port 1)
Setting reg. 42, 58, 74, 90, bit 1 = ‘1’ will perform
remote loopback on port 2, 3, 4, 5.
0 = Normal Operation.
R/W 0
0 Vct_fault_count[8] Bits[8] of VCT fault count
Distance to the fault.
It’s approximately 0.4m*Vct_fault_count[8:0]
RO 0
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 76 Revision 1.3
Port Re gisters (Continued)
Register 27 (0x1B): Port 1 LinkMD result
Register 43 (0x2B): Port 2 LinkMD result
Register 59 (0x3B): Port 3 LinkMD result
Register 75 (0x4B): Port 4 LinkMD result
Register 91 (0x5B): Port 5 LinkMD result
Address Name Description Mode Default
7-0 Vct_fault_count[7:0] Bits[7:0] of VCT fault count
Distance to the fault.
It’s approx imat ely 0.4m*Vct_fault_count[8:0] RO 0
Registe r 2 8 (0x1C): Port 1 Control 5
Registe r 4 4 (0x2C): Port 2 Control 5
Registe r 6 0 (0x3C): Port 3 Control 5
Registe r 7 6 (0x4C): Port 4 Control 5
Registe r 9 2 (0x5C): Port 5 Control 5
Address Name Description Mode Default
7 Disable Auto-Negotiation
1, disable auto-negotiation, speed and duplex are
decided by bit 6 and 5 of the same register.
0, auto-negotiation is on.
Note: T he register bit value is the INVERT of the strap
value at the pin.
R/W
0
For Port 3/Port 4
only. INVERT of
pins
LED[2][1]/LED[5][0]
strap option.
PD(0): Disable Auto-
Negotiation.
PU(1): Enable Auto-
Negotiation.
Note:
LED[2][1]/LED[5][0]
have internal pull
up.
6 Forced Speed 1, forced 100BT if AN is disabled (bit 7).
0, forced 10BT if AN is disabled (bit 7). R/W 1
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 77 Revision 1.3
Port Re gisters (Continued)
Address Name Description Mode Default
5 Forced Duplex
1, forced full-duplex if (1) AN is disabled or (2) AN is
enabled but failed.
0, forced half-duplex if (1) AN is disabled or (2) AN is
enabled but failed (Default).
R/W
0
For Port 3/Port 4
only. Pins
LED1_0/PCRS strap
option:
1). Force half-duplex
mode:
LED1_0 pin Pull-
up(1) (default) for
Port 3
PCRS pin Pull-down
(0) (default) for Port
4
2). Force full-Duplex
mode:
LED1_0 pin Pull-
down(0) for Port 3
PCRS Pull-up (1) for
Port 4.
Note: LED1_0 has
internal pull -up;
PCRS have
internal pull down.
4 Advertised Flow Control
Capability
1, advertise flow contr ol capability.
0, suppress flow control capability from transmission
to link partner. R/W 1
3 Advertised 100BT Full-
Duplex Capability
1, advertise 100BT full-duplex capability.
0, suppress 100BT full-duplex capability from
transmission to link partner. R/W 1
2 Advertised 100BT Half-
Duplex Capability
1, advertise 100BT half-duplex capability.
0, suppress 100BT half-duplex capability from
transmission to link partner. R/W 1
1 Advertised 10BT Full-
Duplex Capability
1, advertise 10BT full-duplex capability.
0, suppress 10BT full-duplex capability from
transmission to link partner. R/W 1
0 Advertised 10BT Half-
Duplex Capability
1, advertise 10BT half-duplex capability.
0, suppre ss 10BT half-duplex capability from
transmission to link partner. R/W 1
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 78 Revision 1.3
Port Re gisters (Continued)
Registe r 2 9 (0x1D): Port 1 Control 6
Registe r 4 5 (0x2D): Port 2 Control 6
Registe r 6 1 (0x3D): Port 3 Control 6
Registe r 7 7 (0x4D): Port 4 Control 6
Registe r 9 3 (0x5D): Port 5 Control 6
Address Name Description Mode Default
7 LED Off
1, turn off all port’s LEDs (LEDx_2, LEDx_1, LEDx_0,
where “x” is the port number). These pins will be driven
high if this bit is set to one.
0, normal operation.
R/W 0
6 Txids 1, disable port’s transmitter.
0, normal operation. R/W 0
5 Restar t AN 1, restart auto-negotiation.
0, normal operation. R/W
(SC) 0
4 FX reserved N/A RO 0
3 Power Down 1, power down.
0, normal operation. R/W 0
2 Disable Auto MDI/MDI-X 1, disable auto MDI/MDI-X function.
0, enable auto MDI/MDI-X function. R/W 0
1 Forced MDI 1, if auto MDI/MDI-X is disabled, force PHY into MDI
mode (transmit on RX pair).
0, MDI-X mode (transmit on TX pair). R/W 0
0 MAC Loopback
1 = Perform MAC loopback, loop back path as follows:
E.g. set port 1 MAC Loopback (reg. 29, bit 0 = ‘1’), use
port 2 as monitor port. The pa ckets w ill trans fer
Start: Port 2 receiv in g (also can start to receive
packets from port 3, 4, 5).
Loop-back: Port 1’s MAC.
End: Port 2 transmitting (also can end at Port 3, 4,
5 respectively).
Setting reg. 45, 61, 77, 93, bit 0 = ‘1’ will perform MAC
loopback on port 2, 3, 4, 5 respectively.
0 = Normal Operation.
R/W 0
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 79 Revision 1.3
Port Re gisters (Continued)
Register 30 (0x1E): Port 1 Status 1
Register 46 (0x2E): Port 2 Status 1
Register 62 (0x3E): Port 3 Status 1
Register 78 (0x4E): Port 4 Status 1
Register 94 (0x5E): Port 5 Status 1
Address Name Description Mode Default
7 MDIX Status 1, MDI.
0, MDI-X. RO 0
6 AN Done 1, AN done.
0, AN not done. RO 0
5 Link Good 1, link good.
0, link not good. RO 0
4 Partner Flow Control
Capability 1, link partner flow control capable.
0, link partner not flow control capable. RO 0
3 Partner 100BT Full-
Duplex Capability 1, link partner 100BT full-duplex capable.
0, link partner not 100BT full-duplex capable. RO 0
2 Partner 100BT Half-
Duplex Capability 1, link partner 100BT half-duplex capable.
0, link partner not 100BT half-duplex capable. RO 0
1 Partner 10BT Full-Duplex
Capability 1, link partner 10BT full-duplex capable.
0, link partner not 10BT full-duplex capable. RO 0
0 Partner 10BT Half-Duplex
Capability 1, link partner 10BT half-duplex capable.
0, link partner not 10BT half-duplex capable. RO 0
Register 31 (0x1F): Port 1 Control 7 and Status 2
Register 47 (0x2F): Port 2 Control 7 and Status 2
Register 63 (0x3F): Port 3 Control 7 and Status 2
Register 79 (0x4F): Port 4 Control 7 and Status 2
Register 95 (0x5F): Port 5 Control 7 and Status 2
Address Name Description Mode Default
7 PHY Loopback
1 = Perform PHY loopback, loop back path as follows:
E.g. set port 1 PHY Loopback (reg. 31, bit 7 = ‘1’)
Use the port 2 as monitor port. The packets will
transfer.
Start: Port 2 receivi ng (also can start from port
3, 4, 5).
Loopback: PMD/PMA of Port 1’s PHY
End: Port 2 transmitting (also can end at Port 3,
4, 5 respectivel y ).
Setting reg. 47, 63, 79, 95, bit 7 = ‘1’ will perform
PHY loopback on port 2, 3, 4, 5 respectively.
0 = Normal Operation.
R/W 0
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 80 Revision 1.3
Port Re gisters (Continued)
Address Name Description Mode Default
6 Reserved RO 0
5 PHY Isolate 1, Electrical isolation of PHY from MII/RMII and
TX+/TX-.
0, normal operation. R/W 0
4 Soft Reset 1, PHY soft reset. This bit is self-clear.
0, normal operation. R/W
(SC) 0
3 Force Link 1, force link in the PHY.
0, normal operation R/W 0
2-0 Port Operation Mode
Indication
Indicate the curre nt state of port operatio n mode:
[000] = Reserved
[001] = still in auto-negotiation
[010] = 10BASE-T half duplex
[011] = 100BASE-TX half duplex
[100] = Reserved
[101] = 10BASE-T full duplex
[110] = 100BASE-TX full duplex
[111] = Reserved
RO 001
Note:
Port Control 12 and 13, 14 and Port Status 1,2 contents can be accessed by MIIM (MDC/MDIO) interface via the standard MIIM register definition.
Advanced Control Registers
Register s 104 to 109 d efine the s witching en gine’s MAC ad dress. T his 48-bit ad dress is us ed as the sourc e address
in MAC pause control frames.
Address Name Description Mode Default
Register 104 (0x68): MAC Address Register 0
7-0 MACA[47:40] R/W 0x00
Register 105 (0x69): MAC Address Register 1
7-0 MACA[39:32] R/W 0x10
Register 106 (0x6A): MAC Address Register 2
7-0 MACA[31:24] R/W 0xA1
Register 107 (0x6B): MAC Address Register 3
7-0 MACA[23:16] R/W 0xff
Register 108 (0x6C): MAC Address Register 4
7-0 MACA[15:8] R/W 0xff
Register 109 (0X6D): MAC Address Register 5
7-0 MACA[7:0] R/W 0xff
Note:
Use Registers 110 and 111 to read or write data to the static MAC address table, VLAN table, dynamic address table, or the MIB counters.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 81 Revision 1.3
Advanced Control Registers (Continued)
Address Name Description Mode Default
Register 110 (0x6E): Indirect Access Control 0
7-5 Reserved Reserved. R/W 000
4 Read High Write Low 1, read cycle.
0, write cycle. R/W 0
3-2 Table Select
00 = static mac address table sele cte d.
01 = VLAN table selected.
10 = dynamic address table selected.
11 = MIB counter selected.
R/W 0
1-0
Indirect Address High
Bit 9-8 of indirect addres s.
R/W
00
Register 111 (0x6F): Indirect Access Control 1
7-0 Indirect Address Low Bit 7-0 of indir ect addr es s. R/W 00000000
Note:
Write to Register 111 will actual l y trigger a command. Read or write access will be decided by bit 4 of Register 110.
Address Name Description Mode Default
Register 112 (0x70): Indirect Data Register 8
68-64 Indirect Data Bit 68-64 of indirect data. R/W 00000
Register 113 (0x71): Indirect Data Register 7
63-56 Indirect Data Bit 63-56 of indirect data. R/W 00000000
Register 114 (0x72): Indirect Data Register 6
55-48 Indirect Data Bit 55-48 of indirect data. R/W 00000000
Register 115 (0x73): Indirect Data Register 5
47-40 Indirect Data Bit 47-40 of indirect data. R/W 00000000
Register 116 (0x74): Indirect Data Register 4
39-32 Indirect Data Bit 39-32 of indirect data. R/W 00000000
Register 117 (0x75): Indirect Data Register 3
31-24 Indirect Data Bit of 31-24 of indirect data R/W 00000000
Register 118 (0x76): Indirect Data Register 2
23-16 Indirect Data Bit 23-16 of indirect data. R/W 00000000
Register 119 (0x77): Indirect Data Register 1
15-8 Indirect Data Bit 15-8 of indirect data. R/W 00000000
Register 120 (0x78): Indirect Data Register 0
7-0 Indirect Data Bit 7-0 of indirect data. R/W 00000000
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 82 Revision 1.3
Advanced Control Registers (Continued)
Address Name Description Mode Default
Register 124 (0x7C): Interrupt Status Register
7 – 5 Reserved Reserved. RO 000
4 Port 5 Interrupt Status
1, Port 5 interrupt request
0, normal
Note: T his bit is set by Port 5 link change. Write a “1” to
clear this bit
RO 0
3 Port 4 Interrupt Status
1, Port 4 interrupt request
0, normal
Note: T his bit is set by Port 4 link change. Write a “1” to
clear this bit
RO 0
2 Port 3 Interrupt Status
1, Port 3 interrupt request
0, normal
Note: T his bit is set by Port 3 link change. Write a “1” to
clear this bit
RO 0
1 Port 2 Interrupt Status
1, Port 2 interrupt request
0, normal
Note: T his bit is set by Port 2 link change. Write a “1” to
clear this bit
RO 0
0 Port 1 Interrupt Status
1, Port 1 interrupt request
0, normal
Note: T his bit is set by Port 1 link change. Write a “1” to
clear this bit
RO 0
Register 125 (0x7D): Interrupt Mask Register
7 – 5 Reserved Reserved. RO 000
4 Port 5 Interrupt Mask 1, Enable Por t 5 interr upt.
0, normal R/W 0
3 Port 4 Interrupt Mask 1, Enable Port 4 interrupt.
0, normal R/W 0
2 Port 3 Interrupt Mask 1, Enable Port 3 interrupt.
0, normal R/W 0
1 Port 2 Interrupt Mask 1, Enable Port 2 interrupt.
0, normal R/W 0
0 Port 1 Interrupt Mask 1, Enable Port 1 interrupt.
0, normal R/W 0
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 83 Revision 1.3
Advanced Control Registers (Continued)
The Registers 1 28, 129 ca n be used to m ap from 802 .1p priorit y field 0-7 to s witc h’s four prior ity queues 0-3, 0x3 is
highest priority queues as priority 3, 0x0 is lowest priority queues as priority 0.
Address Name Description Mode Default
Register 128 (0x80): Global Control 12
7 – 6 Tag_0x3 IEEE 802.1p mapping. The value in this field is
used as the frame’s priority when its IEEE 802.1p
tag has a value of 0x3. R/W 0x1
5 – 4 Tag_0x2 IEEE 802.1p mapping. The value in this field is
used as the frame’s priority when its IEEE 802.1p
tag has a value of 0x2. R/W 0x1
3 – 2 Tag_0x1 IEEE 802.1p mapping. The value in this field is
used as the frame’s priority when its IEEE 802.1p
tag has a value of 0x1. R/W 0x0
1 – 0 Tag_0x0 IEEE 802.1p mapping. The value in this field is
used as the frame’s priority when its IEEE 802.1p
tag has a value of 0x0. R/W 0x0
Register 129 (0x81): Global Control 13
7 – 6 Tag_0x7 IEEE 802.1p mapping. The value in this field is
used as the frame’s priority when its IEEE 802.1p
tag has a value of 0x7. R/W 0x3
5 – 4 Tag_0x6 IEEE 802.1p mapping. The value in this field is
used as the frame’s priority when its IEEE 802.1p
tag has a value of 0x6. R/W 0x3
3 – 2 Tag_0x5 IEEE 802.1p mapping. The value in this field is
used as the frame’s priority when its IEEE 802.1p
tag has a value of 0x5. R/W 0x2
1 – 0 Tag_0x4 IEEE 802.1p mapping. The value in this field is
used as the frame’s priority when its IEEE 802.1p
tag has a value of 0x4. R/W 0x2
Register 130 (0x82): Global Control 14
7 – 6
Pri_2Q[1:0]
(Note that program Prio_2Q[1:0]
= 01 is not supported and should
be avoided)
When the 2 Queues configuration is selected, these
Pri_2Q[1:0] bits are used to map the 2-bit res ult o f
IEEE 802.1p from Register 128/129 or
TOS/DiffServ from Register 14 4- 159 mapping (for
4 Queues) into two queues low/high priorities.
2-bit result of IEEE 802.1p or TOS/DiffServ
00 (0) = map to Low priority queue
01 (1) = Prio_2Q[0] map to Low/High priority queue
10 (2) = Prio_2Q[1] map to Low/High priority queue
11 (3) = map to High priority queue
Pri_2Q[1:0] =
00: Result 0,1,2 are low priority. 3 is high priority.
10: Result 0,1 are low priority. 2,3 are high priority
(default).
11: Result 0 is low priority. 1,2,3 are high priority.
R/W 10
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 84 Revision 1.3
Advanced Control Registers (Continued)
Address Name Description Mode Default
5 Reserved N/A, do not change RO 0
4 Reserved N/A, do not change RO 0
3 – 2 Reserved N/A, do not change RO 01
1 Reserved N/A, do not change RO 0
0 Reserved N/A, do not change RO 0
Register 131 (0x83): Global Control 15
7 Reserved N/A RO 1
6 Reserved N/A RO 0
5 Unknown unicast packet
forward
1 = enable supporting unknown unicast packet
forward
0 = disable R/W 0
4 – 0 Unknown unicast packet
forward port map
00000 = filter unknown unicast packet
00001 = forward unknown unicast packet to port 1,
00010 = forward unknown unicast packet to port 2,
00011 = forward unknown unicast packe t to port 1,
port 2
11111 = broadcast unknown unicast packet to all
ports
R/W 00000
Register 132 (0x84): Global Control 16
7 – 6 Chip I/O output driv e stre ngth
select[1:0]
Output drive strength select[1:0] =
00 = 4mA drive strength
01 = 8mA drive strength (default)
10 = 10mA driv e streng th
11 = 14mA driv e streng th
Note:
Bit [1] value is the INVERT of the strap value at the pin.
Bit[0] value is the SAME of the strap value at the pin
R/W
01
Pin LED [3][0]
strap option.
Pull-down (0):
Select 10mA
drive strength.
Pull-up (1):
Select 8mA
drive strength.
Note: LED [3][0]
has internal
pull-up.
5 Unknown multicast packet
forward (not including IP
multicast pac ket)
1 = enable supporting unknown multicast packet
forward
0 = disable R/W 0
4 – 0 Unknown multicast packet
forward port map
00000 = filter unknown multicast packet
00001 = forward unknown multicast packet to port
1,
00010 = forward unknown multicast packet to port
2,
00011 = forward unknown multicast packet to port
1, port 2
11111 = broad cas t unknow n mult ica st pac ket to all
ports
R/W 00000
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 85 Revision 1.3
Advanced Control Registers (Con tinued)
Address Name Description Mode Default
Register 133(0x85): Global Control 17
7 – 6 Reserved RO 00
5 Unknown VID packet forward 1 = enable supporting unknown VID packet forward
0 = disable R/W 0
4 – 0 Unknown VID packet forward
port map
00000 = filter unknown VID packet
00001 = forward unknown VID packet to port 1,
00010 = forward unknown VID packet to port 2,
00011 = forward unknown VID packet to port 1,
port 2
11111 = broadcast unknown VID packet to all ports
R/W 00000
Register 134 (0x86): Global Control 18
7 Reserved N/A RO 0
6 Self-Address Filter Enable
1 = Enable filtering of self-address unicast and
multicast packet
0 = Do not filter self-address packet
Note: T he self-address fil t eri ng will filter packets on the
egress port, self MAC address is assigned in the Register
104-109.
R/W 0
5 Unknown IP multicast packet
forward
1 = enable supporting unknown IP multicast packet
forward
0 = disable R/W 0
4 – 0 Unknown IP multicast packet
forward port map
00000 = filter unknown IP multicast packet
00001 = forward unkn own IP multicast pac ket to
port 1,
00010 = forward unkn own IP multicast pac ket to
port 2,
00011 = forward unknown IP multicast pac ket to
port 1, port 2
11111 = broadcast unknown IP multicast packet to
all ports
R/W 00000
Register 135 (0x87): Global Control 19
7 Reserved N/A, do not change RO 0
6 Reserved N/A, do not change RO 0
5 – 4 Ingress Rate Limit Period
The unit period for calculating Ingress Rate Limit
00 = 16ms
01 = 64ms
1x = 256ms
R/W 01
3 Queue-based Egress Rate
Limit Enabled
Enable Queue-based Egress Rate Limit
0 = port-base Egress Rate Limit (default)
1 = queue-based Egress Rate Limit R/W 0
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 86 Revision 1.3
Advanced Control Registers (Con tinued)
Address Name Description Mode Default
2 Insertion Source Port PVID
Tag Selection Enable
1 = enable source port PVID tag insertion or non-
insertion option on the egress port for each source
port PVID based on the ports Registers con trol 8.
0 = disable, all packe ts fr om a ny ingress port will be
inserted PVID based on Register Port Control 0 bit
[2].
R/W 0
1 – 0 Reserved N/A, do not change RO 00
Register 137 (0x89): Identification Register
7 – 4 Revision ID
These bits are for the device identification
0000: Reserved
0001-0011: For MQ/FMQ 0.13um silicon devices.
0100 (0x4): For MQX/FQX Rev.A2 and ML Rev.B2
0101 (0x5): For MQX/FQX Rev.A3 and ML Rev.B3
0110 (0x6): For MQX/FQX Rev.A4 and ML Rev.B4
0111-1111: Reserved
RO Depends on
Revision #
3 – 0 Reserved N/A, do not change RO 00
Register 144 (0x90): TOS Priority Control Register 0
The Ipv4/Ipv6 TOS priority control registers implement a fully decoded 64 bit differentiated services code point (DSCP) register
used to determine priority from the 6 bit TOS field in the IP header. The most significant 6 bits of the TOS field are fully decoded
into 64 possibilities, and the singular code that results is mapped to the value in the corresponding bit in the DSCP register.
7 – 6 DSCP[7:6]
Ipv4 and Ipv6 mapping
The value in this field is used as the frame’s priority
when bits [7:2] of the frame’s IP
TOS/DiffServ/Traffic Class value is 0x03
R/W 00
5 – 4 DSCP[5:4]
Ipv4 and Ipv6 mapping
The value in this field is used as the frame’s priority
when bits [7:2] of the frame’s IP
TOS/DiffServ/Traffic Class value is 0x02
R/W 00
3 – 2 DSCP[3:2]
Ipv4 and Ipv6 mapping
The value in this field is used as the frame’s priority
when bits [7:2] of the frame’s IP
TOS/DiffServ/Traffic Class value is 0x01
R/W 00
1 – 0 DSCP[1:0]
Ipv4 and Ipv6 mapping
The value in this field is used as the frame’s priority
when bits [7:2] of the frame’s IP
TOS/DiffServ/Traffic Class value is 0x00
R/W 00
Register 145 (0x91): TOS Priority Control Register 1
7 – 6 DSCP[15:14] Ipv4 and Ipv6 mapping _ for value 0x07 R/W 00
5 – 4 DSCP[13:12] Ipv4 and Ipv6 mapping _ for value 0x06 R/W 00
3 – 2 DSCP[11:10] Ipv4 and Ipv6 mapping _ for value 0x05 R/W 00
1 – 0 DSCP[9:8] Ipv4 and Ipv6 mapping _ for value 0x04 R/W 00
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 87 Revision 1.3
Advanced Control Registers (Con tinued)
Address Name Description Mode Default
Register 146 (0x92): TOS Priority Control Register 2
7 – 6 DSCP[23:22] Ipv4 and Ipv6 mapping _ for value 0x0B R/W 00
5 – 4 DSCP[21:20] Ipv4 and Ipv6 mapping _ for value 0x0A R/W 00
3 – 2 DSCP[19:18] Ipv4 and Ipv6 mapping _ f or v alue 0x 09 R/W 00
1 – 0 DSCP[17:16] Ipv4 and Ipv6 mapping _ for value 0x08 R/W 00
Register 147 (0x93): TOS Priority Control Register 3
7 – 6 DSCP[31:30]
Ipv4 and Ipv6 mapping
_ for value 0x0F R/W 00
5 – 4 DSCP[29:28] Ipv4 and Ipv6 mapping _ for value 0x0E R/W 00
3 – 2 DSCP[27:26] Ipv4 and Ipv6 mapping _ for value 0x0D R/W 00
1 – 0 DSCP[25:24] Ipv4 and Ipv6 mapping _ for value 0x0C R/W 00
Register 148 (0x94): TOS Priority Control Register 4
7 – 6 DSCP[39:38] Ipv4 and Ipv6 mapping _ for value 0x13 R/W 00
5 – 4 DSCP[37:36] Ipv4 and Ipv6 mapping _ for value 0x12 R/W 00
3 – 2 DSCP[35:34] Ipv4 and Ipv6 mapping _ for value 0x11 R/W 00
1 – 0 DSCP[33:32] Ipv4 and Ipv6 mapping _ for value 0x10 R/W 00
Register 149 (0x95): TOS Priority Control Register 5
7 – 6 DSCP[47:46] Ipv4 and Ipv6 mapping _ for value 0x17 R/W 00
5 – 4 DSCP[45:44] Ipv4 and Ipv6 mapping _ for value 0x16 R/W 00
3 – 2 DSCP[43:42] Ipv4 and Ipv6 mapping _ for value 0x15 R/W 00
1 – 0 DSCP[41:40] Ipv4 and Ipv6 mapping _ for value 0x14 R/W 00
Register 150 (0x96): TOS Priority Control Register 6
7 – 6 DSCP[55:54] Ipv4 and Ipv6 mapping _ for value 0x1B R/W 00
5 – 4 DSCP[53:52] Ipv4 and Ipv6 mapping _ for value 0x1A R/W 00
3 – 2 DSCP[51:50] Ipv4 and Ipv6 mapping _ for value 0x19 R/W 00
1 – 0 DSCP[49:48] Ipv4 and Ipv6 mapping _ for value 0x18 R/W 00
Register 151 (0x97): TOS Priority Control Register 7
7 – 6 DSCP[63:62] Ipv4 and Ipv6 mapping _ for value 0x1F R/W 00
5 – 4 DSCP[61:60] Ipv4 and Ipv6 mapping _ for value 0x1E R/W 00
3 – 2 DSCP[59:58] Ipv4 and Ipv6 mapping _ for value 0x1D R/W 00
1 – 0 DSCP[57:56] Ipv4 and Ipv6 mapping _ for value 0x1C R/W 00
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 88 Revision 1.3
Advanced Control Registers (Continued)
Address Name Description Mode Default
Register 152 (0x98): TOS Priority Control Register 8
7 – 6 DSCP[71:70] Ipv4 and Ipv6 mapping _ for value 0x23 R/W 00
5 – 4 DSCP[69:68] Ipv4 and Ipv6 mapping _ for value 0x22 R/W 00
3 – 2 DSCP[67:66] Ipv4 and Ipv6 mapping _ for value 0x21 R/W 00
1 – 0 DSCP[65:64]
Ipv4 and Ipv6 mapping _ for value 0x20
R/W 00
Register 153 (0x99): TOS Priority Control Register 9
7 – 6 DSCP[79:78] Ipv4 and Ipv6 mapping _ for value 0x27 R/W 00
5 – 4 DSCP[77:76] Ipv4 and Ipv6 mapping _ for value 0x26 R/W 00
3 – 2 DSCP[75:74] Ipv4 and Ipv6 mapping _ for value 0x25 R/W 00
1 – 0 DSCP[73:72] Ipv4 and Ipv6 mapping _ for value 0x24 R/W 00
Register 154 (0x9A): TOS Priority Control Register 10
7 – 6 DSCP[87:86] Ipv4 and Ipv6 mapping _ for value 0x2B R/W 00
5 – 4 DSCP[85:84] Ipv4 and Ipv6 mapping _ for value 0x2A R/W 00
3 – 2 DSCP[83:82] Ipv4 and Ipv6 mapping _ for value 0x29 R/W 00
1 – 0 DSCP[81:80] Ipv4 and Ipv6 mapping _ for value 0x28 R/W 00
Register 155 (0x9B): TOS Priority Control Register 11
7 – 6 DSCP[95:94] Ipv4 and Ipv6 mapping _ for value 0x2F R/W 00
5 – 4 DSCP[93:92] Ipv4 and Ipv6 mapping _ for value 0x2E R/W 00
3 – 2 DSCP[91:90] Ipv4 and Ipv6 mapping _ for value 0x2D R/W 00
1 – 0 DSCP[89:88] Ipv4 and Ipv6 mapping _ for value 0x2C R/W 00
Register 156 (0x9C): TOS Priority Control Register 12
7 – 6 DSCP[103:102] Ipv4 and Ipv6 mapping _ for value 0x33 R/W 00
5 – 4 DSCP[101:100]
Ipv4 and Ipv6 mapping
_ for value 0x32 R/W 00
3 – 2 DSCP[99:98] Ipv4 and Ipv6 mapping _ for value 0x31 R/W 00
1 – 0 DSCP[97:96] Ipv4 and Ipv6 mapping _ for value 0x30 R/W 00
Register 157 (0x9D): TOS Priority Control Register 13
7 – 6 DSCP[111:110] Ipv4 and Ipv6 mapping _ for value 0x37 R/W 00
5 – 4 DSCP[109:108] Ipv4 and Ipv6 mapping _ for value 0x36 R/W 00
3 – 2 DSCP[107:106] Ipv4 and Ipv6 mapping _ for value 0x35 R/W 00
1 – 0 DSCP[105:104] Ipv4 and Ipv6 mapping _ for value 0x34 R/W 00
Register 158 (0x9E): TOS Priority Control Register 14
7 – 6 DSCP[119:118] Ipv4 and Ipv6 mapping _ for value 0x3B R/W 00
5 – 4 DSCP[117:116] Ipv4 and Ipv6 mapping _ for value 0x3A R/W 00
3 – 2 DSCP[115:114] Ipv4 and Ipv6 mapping _ for value 0x39 R/W 00
1 – 0 DSCP[113:112] Ipv4 and Ipv6 mapping _ for value 0x38 R/W 00
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 89 Revision 1.3
Advanced Control Registers (Continued)
Address Name Description Mode Default
Register 159 (0x9F): TOS Priority Control Register 15
7 – 6 DSCP[127:126] Ipv4 and Ipv6 mapping _ for value 0x3F R/W 00
5 – 4 DSCP[125:124] Ipv4 and Ipv6 mapping _ for value 0x3E R/W 00
3 – 2 DSCP[123:122] Ipv4 and Ipv6 mapping _ for value 0x3D R/W 00
1 – 0 DSCP[121:120] Ipv4 and Ipv6 mapping _ for value 0x3C R/W 00
Register 165 (0xA5): Reserved
7 0 Reserved N/A, do not change RO 0x30
Register 176 (0xB0): Port 1 Control 8
Register 192 (0xC0): Port 2 Control 8
Register 208 (0xD0): Port 3 Control 8
Register 224 (0xE0): Port 4 Control 8
Register 240 (0xF0): Port 5 Control 8
7 – 4 Reserved RO 0000
3
Insert Source Port PVID for
Untagged Packet Destination
to Highest Egress Port
Note: Enabled by the register
135 bit 2
Register 176: insert source Port 1 PVID for
untagged frame at egress Port 5
Register 192: insert source Port 2 PVID for
untagged frame at egress Port 5
Register 208: insert source Port 3 PVID for
untagged frame at egress Port 5
Register 224: insert source Port 4 PVID for
untagged frame at egress Port 5
Register 240: insert source Port 5 PVID for
untagged frame at egress Port 4
R/W 0
2
Insert Source Port PVID for
Untagged Packet Destination
to Second Highest Egress Port
Note: Enabled by the Register
135 bit 2
Register 176: insert source Port 1 PVID for
untagged fram e at egress pPort 4
Register 192: insert source Port 2 PVID for
untagged frame at egress Port 4
Register 208: insert source Port 3 PVID for
untagged frame at egress Port 4
Register 224: insert source Port 4 PVID for
untagged frame at egress Port 3
Register 240: insert source Port 5 PVID for
untagged frame at egress Port 3
R/W 0
1
Insert Source Port PVID for
Untagged Packet Destination
to Second Lowest Egress Port
Note: Enabled by the Register
135 bit 2
Register 176: insert source Port 1 PVID for
untagged frame at egress Port 3
Register 192: insert source Port 2 PVID for
untagged frame at egress Port 3
Register 208: insert source Port 3 PVID for
untagged frame at egress Port 2
Register 224: insert source Port 4 PVID for
untagged frame at egress Port 2
Register 240: insert source Port 5 PVID for
untagged frame at egress Port 2
R/W 0
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 90 Revision 1.3
Advanced Control Registers (Continued)
Address Name Description Mode Default
0
Insert Source Port PVID for
Untagged Packet Destination
to Lowest Egress Port
Note: Enabled by the Register
135 bit 2
Register 176: insert source Port 1 PVID for
untagged frame at egress Port 2
Register 192: insert source Port 2 PVID for
untagged frame at egress Port 1
Register 208: insert source Port 3 PVID for
untagged frame at egress Port 1
Register 224: insert source Port 4 PVID for
untagged frame at egress Port 1
Register 240: insert source Port 5 PVID for
untagged frame at egress Port 1
R/W 0
Register 177 (0xB1): Port 1 Control 9
Register 193 (0xC1): Port 2 Control 9
Register 209 (0xD1): Port 3 Control 9
Register 225 (0xE1): Port 4 Control 9
Register 241 (0xF1): Port 5 Control 9
7 – 2 Reserved RO 0000000
1 4 Queue Split Enable
This bit in combination with Register16/32/48/64/80
bit 0 will select the split of ½/4 queue s:
{Register177 bit 1, Register16 bit 0} = 11, reserved.
10, the port output queue is split into four priority
queues or if map 802.1p to priority 0-3 mod e.
01, the port output queue is split into two priority
queues or if map 802.1p to priority 0-3 mod e.
00, single output queue on the port. There is no
priority differentiation even though packets are
cl assified into high and low priority.
R/W 0
0 Enable Dropping Tag 0 = disable tag drop
1 = enable tag drop R/W 0
Register 178 (0xB2): Port 1 Control 10
Register 194 (0xC2): Port 2 Control 10
Register 210 (0xD2): Port 3 Control 10
Register 226 (0xE2): Port 4 Control 10
Register 242 (0xF2): Port 5 Control 10
7 Enable Port Transmit Queue 3
Ratio
0, strict priority, will tr ansmit al l the packets from
this priority queue 3 before transmit lower priority
queue.
1, bi t [6:0] reflect the packet number allow to
transmit from this priority queue 3 within a certain
time.
R/W 1
6 – 0 Port Transmit Queue 3
Ratio[6:0] Packet number for Transmit Queue 3 for highest
priority packets in four queues mode. R/W 0001000
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 91 Revision 1.3
Advanced Control Re g isters (Continued)
Address Name Description Mode Default
Register 179 (0xB3): Port 1 Control 11
Register 195 (0xC3): Port 2 Control 11
Register 211 (0xD3): Port 3 Control 11
Register 227 (0xE3): Port 4 Control 11
Register 243 (0xF3): Port 5 Control 11
7 Enable Port Transmit Queue 2
Ratio
0, strict priority, will tra nsmit all the packe ts from
this priority queue 2 before transmit lower priority
queue.
1, bi t [6:0] reflect the packet number allow to
transmit from this priority queue 1 within a certain
time.
R/W 1
6 – 0 Port Transmit Queue 2
Ratio[6:0]
Packet number for Transmit Queue 2 for hig h/low
priority packets in high/low priority packets in four
queues mode. R/W 0000100
Register 180 (0xB4): Port 1 Control 12
Register 196 (0xC4): Port 2 Control 12
Register 212 (0xD4): Port 3 Control 12
Register 228 (0xE4): Port 4 Control 12
Register 244 (0xF4): Port 5 Control 12
7 Enable Port Transmit Queue 1
Rate
0, strict priority, will tr ansmit al l the packets from
this priority queue 1 before transmit lower priority
queue.
1, bit [6:0] reflect the packet number allow to
transmit from this priority queue 1 within a certain
time.
R/W 1
6 – 0 Port Transmit Queue 1
Ratio[6:0]
Packet number for Transmit Queue 1 for low/high
priority packets in four queues mode and high
priority packets in two queues mode. R/W 0000010
Register 181 (0xB5): Port 1 Control 13
Register 197 (0xC5): Port 2 Control 13
Register 213 (0xD5): Port 3 Control 13
Register 229 (0xE5): Port 4 Control 13
Register 245 (0xF5): Port 5 Control 13
7 Enable Port Transmit Queue 0
Rate
0, strict priority, will tr ansmit al l the packets from
this priority queue 0 before transmit lower priority
queue.
1, bi t [6:0] reflect the packet number allow to
transmit from this priority queue 0 within a certain
time.
R/W 1
6 – 0 Port Transmit Queue 0
Ratio[6:0]
Packet number for Transmit Queue 0 for lowest
priority packets in four queues mode and low
priority packets in two queues mode. R/W 0000001
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 92 Revision 1.3
Advanced Control Registers (Continued)
Address Name Description Mode Default
Register 182 (0xB6): Port 1 Rate Limit Control
Register 198 (0xC6): Port 2 Rate Limit Control
Register 214 (0xD6): Port 3 Rate Limit Control
Register 230 (0xE6): Port 4 Rate Limit Control
Register 246 (0xF6): Port 5 Rate Limit Control
7 – 5 Reserved RO 000
4 Ingress Rate Limit Flow
Control Enable
1 = Flow Control is asserted if the port’s receive
rate is exceeded.
0 = Flow Control is not asserted if the port’s receive
rate is exceeded.
R/W 0
3 – 2 Limit Mode
Ingress Limit Mode
These bits determine what kinds of frames are
limited and counted against ingress rate limiting.
= 00, limit and c ount all frames.
= 01, limit and count Broadcast, Multicast, and
flooded unicast frames.
= 10, limit and count Broadcast and Multicast
frames only.
= 11, limit and count Broadcast frames only.
R/W 00
1 Count IFG
Count IFG bytes
= 1, each frame’s minimum inter frame gap.
(IFG) bytes (12 per frame) are included in Ingress
and Egress rate limiting calculations.
= 0, IFG bytes are not counted.
R/W 0
0 Count Pre
Count Preamble bytes
= 1, each frame’s preamble bytes (8 per frame) are
included in Ingress and Egress rate limiting
calculations.
= 0, preamble by t es are not counted.
R/W 0
Register 183 (0xB7): Port 1 Priority 0 Ingress Limit Control 1
Register 199 (0xC7): Port 2 Priority 0 Ingress Limit Control 1
Register 215 (0xD7): Port 3 Priority 0 Ingress Limit Control 1
Register 231 (0xE7): Port 4 Priority 0 Ingress Limit Control 1
Register 247 (0xF7): Port 5 Priority 0 Ingress Limit Control 1
7 Reserved RO 0
6 – 0 Port-Based Priority 0 Ingress
Limit
Ingress data rate limit for priority 0 frames
Ingress traffic from this port is shaped according to
the Data Rate Selected Table. See the table
following the end of Egress limit control registers.
R/W 0000000
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 93 Revision 1.3
Advanced Control Registers (Continued)
Address Name Description Mode Default
Register 184 (0xB8): Port 1 Priority 1 Ingress Limit Control 2
Register 200 (0xC8): Port 2 Priority 1 Ingress Limit Control 2
Register 216 (0xD8): Port 3 Priority 1 Ingress Limit Control 2
Register 232 (0xE8): Port 4 Priority 1 Ingress Limit Control 2
Register 248 (0xF8): Port 5 Priority 1 Ingress Limit Control 2
7 Reserved RO 0
6 – 0 Port-Based Priority 1 Ingress
Limit
Ingress data rate limit for priority 1 frames
Ingress traffic from this port is shaped according to
the Data Rate Selected Table. See the table follow
the end of Egress limit contr ol regis ter s .
R/W 0000000
Register 185 (0xB9): Port 1 Priority 2 Ingress Limit Control 3
Register 201 (0xC9): Port 2 Priority 2 Ingress Limit Control 3
Register 217 (0xD9): Port 3 Priority 2 Ingress Limit Control 3
Register 233 (0xE9): Port 4 Priority 2 Ingress Limit Control 3
Register 249 (0xF9): Port 5 Priority 2 Ingress Limit Control 3
7 Reserved RO 0
6 – 0 Port-Based Priority 2 Ingress
Limit
Ingress data rate limit for priority 2 frames
Ingress traffic from this port is shaped according to
the Data Rate Selected Table. See the table
following the end of Egress limit control registers.
R/W 0000000
Register 186 (0xBA): Port 1 Priority 3 Ingress Limit Control 4
Register 202 (0xCA): Port 2 Priority 3 Ingress Limit Control 4
Register 218 (0xDA): Port 3 Priority 3 Ingress Limit Control 4
Register 234 (0xEA): Port 4 Priority 3 Ingress Limit Control 4
Register 250 (0xFA): Port 5 Priority 3 Ingress Limit Control 4
7 Reserved RO 0
6 – 0 Port-Based Priority 3 Ingress
Limit
Ingress data rate limit for priority 3 frames
Ingress traffic from this port is shaped according to
the Data Rate Selected Table. See the table
following the end of Egress limit control registers.
R/W 0000000
Register 187 (0xBB): Port 1 Queue 0 Egress Limit Control 1
Register 203 (0xCB): Port 2 Queue 0 Egress Limit Control 1
Register 219 (0xDB): Port 3 Queue 0 Egress Limit Control 1
Register 235 (0xEB): Port 4 Queue 0 Egress Limit Control 1
Register 251 (0xFB): Port 5 Queue 0 Egress Limit Control 1
7 Reserved RO 0
6 – 0 Port Queue 0 Egress Limit
Egress data rate limit for priority 0 frames
Egress traffic from this priority queue is shaped
according to the Data Rate Selected Table. See the
table following the end of Egress limit control
registers.
In four queues mode, it is lowest priority.
In two queues mode, it is low priority.
R/W 0000000
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 94 Revision 1.3
Advanced Control Registers (Continued)
Address Name Description Mode Default
Register 188 (0xBC) : Port 1 Queue 1 Egress Limit Control 2
Register 204 (0xCC) : Port 2 Queue 1 Egress Limit Control 2
Register 220 (0xDC) : Port 3 Queue 1 Egress Limit Control 2
Register 236 (0xEC) : Port 4 Queue 1 Egress Limit Control 2
Register 252 (0xFC) : Port 5 Queue 1 Egress Limit Control 2
7 Reserved RO 0
6 – 0 Port Queue 1 Egress Limit
Egress data rate limit for priority 1 frames
Egress traffic from this priority queue is shaped
according to the Data Rate Selected Table. See the
table follow the end of Egress limit control registers.
In four queues mode, it is low/high priority.
In two queues mode, it is high priority .
R/W 0000000
Register 189 (0xBD): Port 1 Queue 2 Egress Limit Control 3
Register 205 (0xCD): Port 2 Queue 2 Egress Limit Control 3
Register 221 (0xDD): Port 3 Queue 2 Egress Limit Control 3
Register 237 (0xED): Port 4 Queue 2 Egress Limit Control 3
Register 253 (0xFD): Port 5 Queue 2 Egress Limit Control 3
7 Reserved RO 0
6 – 0 Port Queue 2 Egress Limit
Egress data rate limit for priority 2 frames
Egress traffic from this priority queue is shaped
according to the Data Rate Selected Table. See the
table following the end of Egress limit control
registers.
In four queues mode, it is high/low priority.
R/W 0000000
Register 190 (0xBE) : Port 1 Queue 3 Egress Limit Control 4
Register 206 (0xCE) : Port 2 Queue 3 Egress Limit Control 4
Register 222 (0xDE) : Port 3 Queue 3 Egress Limit Control 4
Register 238 (0xEE): Port 4 Queue 3 Egress Limit Control 4
Register 254 (0xFE): Port 5 Queue 3 Egress Limit Control 4
7 Reserved RO 0
6 – 0 Port Queue 3 Egress Limit
Egress data rate limit for priority 3 frames
Egress traffic from this priority queue is shaped
according to the Data Rate Selected Table. See the
table follow the end of Egress limit control registers.
In four queues mode, it is highest priority.
R/W 0000000
Note:
In the port priority 0-3 ingress rate limit mode, will need to set all related ingress/egress ports to two queues or four queues mode. In the port
queue 0-3 egress rate limit mode, the highest priority get exact rate limit based on the rate select table, other priorities pack ets rate are based
upon the ratio of the Register Port Control 10/11/12/13 when use more than one egress queue per port.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 95 Revision 1.3
Data Rate Limit Selection Limit Table
Table 14. 10/100BT Rate Selection for the Rate limit
Data Rate Limit for
Ingress or Egress
100BT
Priority/Queue 0-3 Ingr es s/egr ess li mit
Control Register bit [6:0] = decimal
10BT
Priority/Queue 0-3 Ingr es s/egr ess li mit
Control Register bit [6:0] = decimal
1 Mbps <= rate <= 99 Mbps
rate(decimal integer 1-99) 1 Mbps <= rate <= 9 Mbps
rate(decimal integer 1-9)
0 or 100 (decimal), ‘0’ is default value 0 or 10 (decimal), ‘0’ is default value
Less than 1Mbps
(see as below) Decimal
64 Kbps 7’d101
128 Kbps 7’d102
192 Kbps 7’d103
256 Kbps 7’d104
320 Kbps 7’d105
384 Kbps 7’d106
448 Kbps 7’d107
512 Kbps 7’d108
576 Kbps 7’d109
640 Kbps 7’d110
704 Kbps 7’d111
768 Kbps 7’d112
832 Kbps 7’d113
896 Kbps 7’d114
960 Kbps 7’d115
Address Name Description Mode Default
Register 191(0xBF): Testing Register 1
7 - 0 Reserved N/A, do not change. RO 0x80
Register 207(0xCF): Reserved Control Register
7 - 0 Reserved N/A, do not change. RO 0x15
Register 223(0xDF): Testing Register 2
7 - 0 Reserved R/W 0x0C
Register 239(0xEF): Port 3 Copper or Fiber Control
7 Fiber select for
Port 3 0 = Port 3 is copper port (default)
1 = Port 3 is fiber port. R/W 0
6 - 0 Reserved N/A, Do not change. RO 0110010
Register 255(0xFF): Testing Register 3
7- 0 Reserved N/A, Do not change. RO 0x00
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 96 Revision 1.3
Static MAC Address Table
KSZ8895 MQX /RQ X /F QX /ML has a s ta tic and a d yna mic addres s table. When a DA l ook-up is reques te d, b ot h ta bles
will be sear ched to m ake a pack et forwarding decis ion. When an SA look -up is requested, o nly the d ynam ic table is
searched for aging, migration, and learning purposes. The static DA look-up result will have precedence over the
dynamic DA look-up result. If there are DA matches in both tables, the result from the static table will be used. The
static ta ble can onl y be access ed and control led by an ex ternal SPI m aster (usual ly a processor ). The entrie s in the
static table will not be aged out by KSZ8895MQX/RQX/FQX/ML. An external device does all addition, modification
and deletion.
Note:
Register bit assignments are different for static MAC table reads and static MAC table write, as shown in Table 15.
Table 15. Stat ic MAC Address Table
Address Name Description Mode Default
Format of Static MAC Table for Reads (32 entries)
63-57 FID Filter VLAN ID, representing one of the 128 active
VLANs. RO 0000000
56 Use FID 1, use (FID+MAC) to look-up in static table.
0, use MAC only to look-up in static table. RO 0
55 Reserved Reserved. RO N/A
54 Override
1, override spanning tree “transmit enable = 0” or
“receive ena ble = 0* setting. T his bit is used for
spanning tree implementation.
0, no override.
RO 0
53 Valid 1, this entry is valid, the look-up result will be used.
0, this entry is not valid. RO 0
52-48 Forwarding Ports
The 5 bits control the forward ports, example:
00001, forward to Port 1
00010, forward to Port 2
…..
10000, forward to Port 5
00110, forward to Port 2 and Port 3
11111, broadcasting (excluding the ingress port)
RO 00000
47-0 M AC Address (DA) 48 bit MAC address. RO 0x0
Format of Static MAC Table for Writes (32 entries)
62-56 FID Filter VLAN ID, representing one of the 128 active
VLANs. W 0000000
55 Use FID 1, use (FID+MAC) to look-up in static tabl e.
0, use MAC only to look-up in static table. W 0
54 Override
1, override spanning tree “transmit enable = 0” or
“receive ena ble = 0” setting. This bit is used for
spanning tree implementation.
0, no override.
W 0
53 Valid 1, this entry is valid, the look-up result will be used.
0, this entry is not valid. W 0
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 97 Revision 1.3
Table 15. Static MA C Address Tabl e (Continued)
Address Name Description Mode Default
52-48 Forwarding Ports
The 5 bits control the forward ports, example:
00001, forward toPort 1
00010, forward to Port 2
.....
10000, forward to Port 5
00110, forward to Port 2 and Port 3
11111, broadcasting (excluding the ingress port)
W 00000
47-0 MAC Address (DA) 48-bit MAC address. W 0x0
Examples:
(1) Static Address Table Read (read the 2nd entry)
Write to Register 110 with 0x10 (read static table selected)
Write to Register 111 with 0x1 (trigger the read operation)
Then
Read Register 113 (63-56)
Read Register 114 (55-48)
Read Register 115 (47-40)
Read Register 116 (39-32)
Read Register 117 (31-24)
Read Register 118 (23-16)
Read Register 119 (15-8)
Read Register 120 (7-0)
(2) Static Address Table Write (write the 8th entry)
Write to Register 110 with 0x10 (read static table selected)
Write Register 113 (62-56)
Write Register 114 (55-48)
Write Register 115 (47-40)
Write Register 116 (39-32)
Write Register 117 (31-24)
Write Register 118 (23-16)
Write Register 119 (15-8)
Write Register 120 (7-0)
Write to Register 110 with 0x00 (write static table selected)
Write to Register 111 with 0x7 (trigger the write operation)
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 98 Revision 1.3
VLAN Table
The VLAN table is used f or VLAN tabl e look-up. If 802 .1q VLAN m ode is enabled (Register 5 b it 7 = 1), this table is
used to retri eve VLAN inf orm ation that is assoc iated with th e ingress packet. T here are three f ields for FID (filter ID),
Valid, and VLAN m embership i n the VLAN table. The three fields must be init ia liz ed bef or e the t ab le is us ed. There is
no VID field because 4096 VIDs are used as a de dicated m emory address index into a 1024x52-bit memory space.
Each entr y has four VLANs. Each VLAN has 13 bits. Four VLANs need 52 bits. There are a total of 1024 entries to
support a total of 4096 VLAN IDs by using dedicated memory address and data bits. Refer to Table 16 for details.
FID has 7-bits to support 128 active VLANs.
Table 16. VLAN Table
Address Name Description Mode
Initial Value
suggestion
12 Valid
1, the entry is valid.
0, entry is invalid. R/W 0
11 7 Membership
Specify which ports are members of the VLAN.
If a DA look-up fails (no match in both static and
dynamic tables), the packet associated with this VLAN
will be forwarded to ports specified in this field.
E.g., 11001 means port 5, port 4 and port 1.
R/W 11111
6 0 FID
Filter ID. KSZ8895MLU supports 128 active VLANs
represented by these seven bit fields. FID is the
mapped ID. If 802.1q VLAN is enabled, the loo k-up in
MAC table will be based on FID+DA and FID+SA.
R/W 0
If 802.1q VLAN m ode is enabled, KSZ8895 MLU assig ns a VID to ev ery ingress pack et when the pac ket is untag ged
or tagge d with a null V ID, the pac ket is as signed with the defaul t port VID of the ingress port. If the pac ket is tag ged
with non-null VID, the VID i n the tag is us ed. The look -up process star ts from the VLAN table look-up based on VID
number with its dedicated memory address and data bits. If the entry is not valid in the VLAN table, the packet is
dropped a nd no addr ess le arning occ urs. If the entr y is valid, the F ID is retr ieved. The FID +DA and F ID+SA lookups
in MAC ta bl es ar e perf or m ed. The FID +D A look-up de ter mines the f orwarding por ts . If F ID+D A f ai ls f or look -up in the
MAC table, the packet is broadcast to all the mem bers or specified members (excluding the ingress port) based on
the VLAN table. If FID+SA fails, the FID+SA is learned. To communicate between different active VLANs, set the
same FID; otherwise set a different FID.
The VLAN table configuration is organized as 1024 VLAN sets, each VLAN set consists of four VLAN entries, to
support up to 4096 VLAN entries. Each VLAN set has 52 bits and should be read or written at the same time
specified by the indirect address.
The VLAN entries in the VLAN set is mapped to indirect data registers as follow:
Entry0[12:0] maps to the VLAN set bits[12 0] {register119[4:0], register120[7:0]}
Entry1[12:0] maps to the VLAN set bits[25 13]{register117[1:0], register118[7:0], register119[7:5]}
Entry2[12:0] maps to the VLAN set bits[38 26]{register116[6:0], register117[7:2]}
Entry3[12:0] maps to the VLAN set bits[51 39]{register114[3:0], register115[7:0], register116[7]}
In order to re ad o ne VLAN entry, the V LAN s et is r e ad f irs t and th e s pec if ic VLA N entry information can be e x trac ted.
To update any VLAN entry, the VLAN set is read first then only the desired VLAN entry is updated and the whole
VLAN set is written back. Due to FID in VLAN table is 7-bit, so the VLAN table supports unique 128 flow VLAN
groups. Each VLAN se t address is 10 bits long (M aximum is 1024) in the indirec t address register 110 an d 111, the
bit [9 8] of VLAN set addr ess is at bit [1 0] of r egister 110, and the b it [7 0] of VLAN se t address is at bit [7-0] of
register 111. Each Write and Read can access to four consecutive VLAN entries.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 99 Revision 1.3
Examples:
(1) VLAN Table Read (read the VID=2 entr y)
Write the indirect control and address registers first
Write to Register 110 (0x6E) with 0x14 (read VLAN table selected)
Write to Register 111 (0x6F) with 0x0 (trigger the read operation for VID=0, 1, 2, 3 entries)
Then read the indirect data registers bits [38-26] for VID=2 entry
Read Register 116 (0x74), (register 116 [6:0] are bits 12 6 of VLAN VID=2 entry)
Read Register 117 (0x75), (register 117 [7:2] are bits 5 0 of VLAN VID=2 entry)
(2) VLAN Table Write (write the VID=10 entry)
Read the VLAN set that contains VID =8 , 9, 10, 11.
Write to Register 110 (0x6E) with 0x14 (read VLAN table selected)
Write to Register 111 (0x6F) with 0x02 (trigger the read operation and VID=8, 9, 10, 11 indirect
address)
Read the VLAN set first by the indirect data registers 114, 115, 116, 117, 118, 119, 120.
Modify the indirect data registers bits [38 26] by the register 116 bit [6-0] and register 117 bit [7 2] as
follows:
Write to Register 116 (0x74), (register116 [6:0] are bits 12 6 of VLAN VID=10 entry)
Write to Register 117 (0x75), (register117 [7:2] are bits 5 0 of VLAN VID=10 entry)
Then write the indirect control and address registers
Write to Register 110 (0x6E) with 0x04 (write VLAN table selected)
Write to Register 111 (0x6F) with 0x02 (trigger the write operation and VID = 8, 9, 10, 11 indirect
address)
Table 17 shows the relationship of the indirect address/data registers and VLAN ID.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 100 Revision 1.3
Table 17. VLAN ID and Indirect Registers
Indirect Address
High/Low Bit[9-0]
for VLAN Sets
Indirect Data
Registers Bits for
Each VLAN Entry
VID
Numbers VID bit[12-2] in VLAN
Tag VID bit[1-0] in VLAN Tag
0 Bits[12 0] 0 0 0
0 Bits[25 13] 1 0 1
0 Bits[38 26] 2 0 2
0 Bits[51 39] 3 0 3
1 Bits[12 0] 4 1 0
1 Bits[25 13] 5 1 1
1 Bits[38 26] 6 1 2
1 Bits[51 39] 7 1 3
2 Bits[12 0] 8 2 0
2 Bits[25 13] 9 2 1
2 Bits[38 26] 10 2 2
2 Bits[51 39] 11 2 3
1023 Bits[12 0] 4092 1023 0
1023 Bits[25 13] 4093 1023 1
1023 Bits[38 26] 4094 1023 2
1023 Bits[51 39] 4095 1023 3
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 101 Revision 1.3
Dynamic MAC Address Table
This table is read only. The contents are maintained by the KSZ8895MQX/RQX/FQX/ML only.
Table 18. Dynamic MAC Address Table
Address Name Description Mode Default
Format of Dynamic MAC Address Table (1K entries)
71 MAC Empty 1, there is no valid entry in the table.
0, there are valid entries in the table. RO 1
70-61 No of Valid Entries
Indicates how many valid entries in the table.
0x3ff means 1K entries
0x1 and bit 71 = 0: m ean s 2 entr ie s
0x0 and bit 71 = 0: means 1 entr y
0x0 and bit 71 = 1: means 0 entr y
RO 0
60-59 Time Stamp 2-bit counters for inter nal agin g RO
58-56 Source Port
The source port where FID+MAC is learned.
000 Port 1
001 Port 2
010 Port 3
011 Port 4
100 Port 5
RO 0x0
55 Data Ready 1, The entry is not ready, retry until this bit is set to 0.
0, The entry is ready. RO
54-48 FID Filter ID. RO 0x0
47-0 MAC Address 48-bit MAC address. RO 0x0
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 102 Revision 1.3
Examples:
(1) Dynamic MAC Address Table Read (read the 1st entry), and retrieve the MAC table size
Write to Register 110 with 0x18 (read dynamic table selected)
Write to Register 111 with 0x0 (trigger the read operation) and then
Read Register 112 (71-64)
Read Register 113 (63-56); // the above two registers show # of entries
Read Register 114 (55-48) // if bit 55 is 1, restart (reread) from this register
Read Register 115 (47-40)
Read Register 116 (39-32)
Read Register 117 (31-24)
Read Register 118 (23-16)
Read Register 119 (15-8)
Read Register 120 (7-0)
(2) Dynamic MAC Address Table Read (read the 257th entry), without retrieving # of entries information
Write to Register 110 with 0x19 (read dynamic table selected)
Write to Register 111 with 0x1 (trigger the read operation) and then
Read Register 112 (71-64)
Read Register 113 (63-56)
Read Register 114 (55-48) // if bit 55 is 1, restart (reread) from this register
Read Register 115 (47-40)
Read Register 116 (39-32)
Read Register 117 (31-24)
Read Register 118 (23-16)
Read Register 119 (15-8)
Read Register 120 (7-0)
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 103 Revision 1.3
MIB (Management Information Base) Counters
The MIB counters are provided on per port basis. These counters are read using indirect memory access as below:
For Port 1
Table 19. Port 1 MIB Counter Indirect Memory Offsets
Offset Counter Name Description
0x0 RxLoPriorityByte Rx low-priority (defau lt) octet count inc lud ing bad pac ket s.
0x1 RxHiPriorityByte Rx hi-priority octet count in clu ding bad pac ket s.
0x2 RxUndersizePkt Rx undersize packet s w /good CR C .
0x3 RxFragments Rx fragment packets w/bad CRC, symbol errors or alignment errors.
0x4 RxOversize Rx oversize packets w/good CRC (max: 1536 or 1522 bytes).
0x5 RxJabbers Rx packets longer than 1522B w/either CRC errors, alignment errors, or symbol errors
(depends on max packet size setting) or Rx packets longer than 1916B only.
0x6 RxSymbolError Rx packets w/ invalid data symbol and legal preamble, packet size.
0x7 RxCRCerror Rx packets within (64,1522) bytes w/an integral number of bytes and a bad CRC (upper
limit depends on max packet size setting).
0x8 RxAlignmentError Rx packets within (64,1522) bytes w/a non-integral number of bytes and a bad CRC (upper
limit depends on max packet size setting).
0x9 RxControl8808Pkts The number of MAC control frames received by a port with 88-08h in EtherType field.
0xA RxPausePkts The number of PAUSE frames received by a port. PAUSE frame is qualified with
EtherType (88-08h), DA, control opcode (00-01), data length (64B min), and a valid CRC.
0xB RxBroadcast Rx good broadcast packets (not including errored broadcast packets or valid multicast
packets).
0xC RxMulticast Rx good multicast packets (not including MAC control frames, errored multicast packets or
valid broadcast packets).
0xD RxUnicast Rx good unicast packets.
0xE Rx64Octets Total Rx packets (bad packets included) that were 64 octets in length.
0xF Rx65to127Octets Total Rx packets (bad packets included) that are between 65 and 127 octets in length.
0x10 Rx128to255Octets Total Rx packets (bad packets included) that are between 128 and 255 octets in length.
0x11 Rx256to511Octets Total Rx packets (bad packets included) that are between 256 and 511 octets in length.
0x12 Rx512to1023Octets Total Rx packets (bad packets included) that are between 512 and 1023 octets in length.
0x13 Rx1024to1522Octets Total Rx packets (bad packets included) that are between 1024 and 1522 octets in length
(upper limit depends on max packet size setting).
0x14 TxLoPriorityByte Tx low-priority good octet count, including PAUSE packets.
0x15 TxHiPriorityByte Tx hi-priority good octet count, including PAUSE packets.
0x16 TxLateCollision The number of times a collision is detected later than 512 bit-times into the Tx of a packet.
0x17 TxPausePkts The number of PAUSE frames transmitted by a port.
0x18 TxBroadcastPkts Tx good broadcast packets (not including errored broadcast or valid multicast packets).
0x19 TxMulticastPkts Tx good multicast packets (not including errored multicast packets or valid broadcast
packets).
0x1A TxUnicastPkts Tx good unicast packets.
0x1B TxDeferred Tx packets by a port for which the 1st Tx attempt is delayed due to the busy medium.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 104 Revision 1.3
Table 19. Port 1 MIB Counter Indirect Memory Offsets (Continued)
Offset Counter Name Description
0x1C TxTotalCollision Tx total collision, half-duplex only.
0x1D TxExcessiveCollision A count of frames for which Tx fails due to excessive collisions.
0x1E TxSingleCollision Successfully Tx frames on a port for which Tx is inhibited by exactly one collision.
0x1F TxMultipleCollision Successfully Tx frames on a port for which Tx is inhibited by more than one collision.
For Port 2
The base is 0x20, same offset definition (0x20-0x3f).
For Port 3
The base is 0x40, same offset definition (0x40-0x5f).
For Port 4
The base is 0x60, same offset definition (0x60-0x7f).
For Port 5
The base is 0x80, same offset definition (0x80-0x9f).
Table 20. Format of Per PortMIB Counter
Address Name Description Mode Default
Format of Per Port MIB Counters (16 entries)
31 Overflow 1, Counter overflow.
0, No Counter overflow. RO 0
30 Count Valid 1, Counter value is valid.
0, Counter value is not valid. RO 0
29-0 Counter Values Counter value. RO 0
Table 21. All Port Dropped Packet MIB Counters
Offset Counter Name Description
0x100 Port1 Tx Drop Packets Tx packets dropped due to lack of resources.
0x101 Port2 Tx Drop Packets Tx packets dropped due to lack of resources.
0x102 Port3 Tx Drop Packets Tx packets dropped due to lack of resources.
0x103 Port4 Tx Drop Packets Tx packets dropped due to lack of resources.
0x104 Port5 Tx Drop Packets Tx packets dropped due to lack of resources.
0x105 Port1 Rx Drop Packets Rx packets dropped due to lack of resources.
0x106 Port2 Rx Drop Packets Rx packets dropped due to lack of resources.
0x107 Port3 Rx Drop Packets Rx packets dropped due to lack of resources.
0x108 Port4 Rx Drop Packets Rx packets dropped due to lack of resources.
0x109 Port5 Rx Drop Packets Rx packets dropped due to lack of resources.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 105 Revision 1.3
Table 22. Format of All Dropped PacketMIB Counter
Address Name Description Mode Default
Format of All Port Dropped Packet MIB Counters
30-16 Reserved Reserved. N/A N/A
15-0 Counter Values Counter value. RO 0
Note:
All port dropped packet MIB counters do not indicate overflow or validity; theref ore t he application must keep track of overflow and valid
conditions.
The KSZ8895MQX/RQX/FQX/ML provides a total of 34 MIB counters per port. These counters are used to monitor
the port detail activity for network management and maintenance. These MIB counters are read using indirect
memory access, per the following examples.
Programming Examples:
(1) MIB counter read (read port 1 Rx64Octets counter)
Write to Register 110 with 0x1c (read MIB counters selected)
Write to Register 111 with 0xe (trigger the read operation)
Then
Read Register 117 (counter value 31-24)
// If bit 31 = 1, there was a counter overflow
// If bit 30 = 0, restart (reread) from this register
Read Register 118 (counter value 23-16)
Read Register 119 (counter value 15-8)
Read Register 120 (counter value 7-0)
(2) MIB counter read (read port 2 Rx64Octets counter)
Write to Register 110 with 0x1c (read MIB counter selected)
Write to Register 111 with 0x2e (trigger the read operation)
Then
Read Register 117 (counter value 31-24)
//If bit 31 = 1, there was a counter overflow
//If bit 30 = 0, restart (reread) from this register
Read Register 118 (counter value 23-16)
Read Register 119 (counter value 15-8)
Read Register 120 (counter value 7-0)
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 106 Revision 1.3
(3) MIB counter read (read port 1 tx drop packets)
Write to Register 110 with 0x1d
Write to Register 111 with 0x00
Then
Read Register 119 (counter value 15-8)
Read Register 120 (counter value 7-0)
Note:
To read out all the counters, the best performance over the SPI bus is (160+3) × 8 × 80 = 104us, where there are 255 regist ers, 3 overhead, 8
clocks per access, at 12.5MHz. In the heaviest conditi on, t he byte counter will overflow in 2 minutes. It is recommended that the software read all
the counters at least every 30 seconds. The per port MIB counters are designed as “read clear.” A per port MIB counter will be cleared after it is
access ed. All port dropped packet MIB counters are not cleared aft er they are accessed. The applicat i on needs to keep track of overflow and valid
conditi ons on these counters.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 107 Revision 1.3
MIIM Registers
All the registers defined in this section can be also accessed via the SPI interface. Note: different mapping
mechanis m s are us ed for MIIM and SPI. T he “PH YAD” def ined in IEEE is assig ned as “0x 1” f or Port 1, “0x 2” f or Port
2, “0x3” for Port 3, “0x4” for Port 4, and “0x5” for Port 5. The “REGAD” supported are 0x0-0x5 (0h-5h), 0x1D (1dh)
and 0x1F (1fh).
Address Name Description Mode Default
Register 0h: MII Control
15 Soft Reset 1, PHY soft reset.
0, Normal operation. R/W
(SC) 0
14 Loop Back
1 = Perform MAC loopback, lo op back path as follows:
Assume the loop-back is at Port 1 MAC, Port 2 is the
monitor port.
Port 1 MAC Loopback (Port 1 reg. 0, bit 14 = ‘1’)
Start: RXP2/RXM2 (Port 2). Can also start from
port 3, 4, 5
Loopback: MAC/PHY interface of Port 1’s MAC
End: TXP2/TXM2 (Port 2). Can also end at
Ports 3, 4, 5 respectively
Setting address ox3,4,5 reg. 0, bit 14 = ‘1’ will
perform MAC loopback on Ports 3, 4, 5 respec tiv ely .
0 = Normal Operation.
R/W 0
13 Force 100 1, 100Mbps.
0, 10Mbps. R/W 1
12 AN Enable 1, Auto-negotiat ion ena ble d.
0, Auto-negotiation disab led. R/W 1
11 Power Down 1, Power down.
0, Normal operation. R/W 0
10 PHY Isolate 1, Electrical PHY isolation of PHY from Tx+/Tx-.
0, Normal operation. R/W 0
9 Restar t AN 1, Restart Auto-negotiation.
0, Normal operation. R/W 0
8 Force Full Duplex 1, Full duplex.
0, Half duplex . R/W 0
7 Collision Test Not supported. RO 0
6 Reserved RO 0
5 Hp_mdix 1 = HP Auto MDI/MDI-X mode.
0 = Micrel Auto MDI/MDI-X mode. R/W 1
4 Force MDI 1, Force MDI.
0, Normal operation. (MDIX transmit on TXP/TXM pair) R/W 0
3 Disable Auto MDI/MDI-X 1, Disable auto MDI/MDI-X.
0, Enable auto MD I/M DI -X. R/W 0
2 Disable far End fault 1, Disable far end fault detection.
0, Normal operation. R/W 0
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 108 Revision 1.3
MIIM Registers (Continued)
Address Name Description Mode Default
1 Disable Transmit 1, Disable transmit.
0, Normal operation. R/W 0
0 Disable LED 1, Disable LED.
0, Normal operation. R/W 0
Register 1h: MII Status
15 T4 Capable 0, Not 100 BASET4 capable. RO 0
14 100 Full Capable 1, 100BASE-TX full-duplex capable.
0, Not capable of 100BASE-TX ful l-duplex. RO 1
13 100 Half Capable 1, 100BASE-TX half-duplex capable.
0, Not 100BASE-TX half-duplex capable. RO 1
12 10 Full Capable 1, 10BASE-T full-duplex capable.
0, Not 10BASE-T full -duplex capable. RO 1
11 10 Half Capable 1, 10BASE-T half-duplex capable.
0, 10BASE-T half-duplex capable. RO 1
10-7 Reserved RO 0
6 Preamble Suppressed Not supported. RO 0
5 AN Complete 1, Auto-nego tiat ion co mpl ete.
0, Auto-negotiation not compl e ted. RO 0
4 far End fault 1, far end fault detected.
0, No far end fault detected. RO 0
3 AN Capable 1, Auto-nego tiat ion ca pable.
0, Not auto-negot iation capabl e. RO 1
2 Link Status 1, Link is up.
0, Link is down. RO 0
1 Jabber Test Not supported. RO 0
0 Extended Capable 0, Not extended register capable. RO 0
Registe r 2h: PHYID HIGH
15-0 Phyid High High order PHYID bits. RO 0x0022
Registe r 3h: PHYID LOW
15-0 Phyid Low Low order PHYID bits. RO 0x1450
Register 4h: Advertisement Ability
15 Next Page Not supported. RO 0
14 Reserved RO 0
13 Remote fault Not supported. RO 0
12-11 Reserved RO 0
10 Pause 1, Advertise pause ability.
0, Do not advertise pause ability. R/W 1
9 Reserved R/W 0
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 109 Revision 1.3
MIIM Registers (Continued)
Address
Name Description Mode Default
8 Adv 100 Full 1, Advertise 100 full-duplex ability.
0, Do not advertise 100 full-duplex ability. R/W 1
7 Adv 100 Half 1, Advertise 100 half-duplex ability.
0, Do not advertise 100 half-duplex ability. R/W 1
6 Adv 10 Full 1, Advertise 10 full-duplex ability.
0, Do not advertise 10 full-duplex ability. R/W 1
5 Adv 10 Half 1, Advertise 10 half-duplex ability.
0, Do not advertise 10 half-duplex ability. R/W 1
4-0 Selector Field 802.3 RO 00001
Register 5h: Link Partner Ability
15 Next Page Not supported. RO 0
14 LP ACK Not supported. RO 0
13 Remote fault Not supported. RO 0
12-11 Reserved RO 0
10 Pause 1, link partner flow control capable.
0, link partner not flow control capable. RO 0
9 Reserved RO 0
8 Adv 100 Full 1, link partner 100BT full-duplex capable.
0, link partner not 100BT full-duplex capable. RO 0
7 Adv 100 Half 1, link partner 100BT half-duplex capable.
0, link partner not 100BT half-duplex capable. RO 0
6 Adv 10 Full 1, link partner 10BT full-duplex capable.
0, link partner not 10BT full-duplex capable. RO 0
5 Adv 10 Half 1, link partner 10BT half-duplex capable.
0, link partner not 10BT half-duplex capable. RO 0
4-0 Reserved RO 00001
Register 1dh: LinkMD Control/Status
15 Vct_enable
1 = Enable cable diagnostic. AfterVCT test has
completed, this bit will be self-cleared.
0 = Indicate cable diagnostic test (if enabled) has
completed and the status information is valid for read.
R/W
(SC) 0
14-13 Vct_result
00 = Normal condition
01 = Open condition detected in cable
10 = Short condition detected in cable
11 = Cable diagnostic test has failed
RO 00
12 Vct 10M Short 1 = Less than 10 meter short RO 0
11-9 Reserved RO 0
8-0 Vct_fault_count Distance to the fault.
It’s approximately 0.4m*vct_fault_count[8:0] RO 000000000
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 110 Revision 1.3
MIIM Registers (Continued)
Address
Name Description Mode Default
Register 1fh: PHY Special Control/Status
15-11 Reserved RO 00000
10-8 Port Operation Mode
Indication
Indicate the curre nt state of port operation mode:
[000] = reserved
[001] = still in auto-negotiation
[010] = 10BASE-T half duplex
[011] = 100BASE-TX half duplex
[100] = reserved
[101] = 10BASE-T full duplex
[110] = 100BASE-TX full duplex
[111] = PHY/MII isolate
RO 000
7-6 Reserved
N/A, don’t change
RO 00
5 Polrvs
1 = Polarity is reversed
0 = Polarity is not reversed RO 0
4 MDI-X status
1 = MDI
0 = MDI-X RO 0
3 Force_lnk
1 = Force link pass
0 = Normal operation R/W 0
2 Pwrsave
1 = Enable power save
0 = Disable power save
R/W 0
1 Remote Loopback
1 = Perform Remote loopback, loop back path as
follows:
Port 1 (PHY ID address 0x1 reg. 1f, bit 1 = ‘1’)
Start: RXP1/RXM1 (port 1)
Loopback: PMD/PMA of port 1’s PHY
End: TXP1/TXM1 (port 1)
Setting PHY ID address 0x2,3,4,5 reg. 1f, bit 1 = ‘1’
will perform remote loopback on port 2, 3, 4, 5.
0 = Normal Operation.
R/W 0
0 Reserved RO 0
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 111 Revision 1.3
Absolute Maximum Ratings(7)
Suppl y Voltage
(VDDAR, VDDAP, V DDC) ............................. 0.5V to +2.4V
(VDDAT, VDDIO) ....................................... 0.5V to +4.0V
Input Voltage .............................................. 0.5V to +4.0V
Output Volta ge ........................................... 0.5V to +4.0V
Lead Temperature (soldering, 10s) .......................... 260°C
Storage Temperature (TS) ....................... 55°C to +150°C
HBM ESD Rating .......................................................... 5KV
Operating Ratings(8)
Suppl y Voltage
(VDDAR, VDDC) ................................ 1.140V to 1.320V
(VDDAT) ......................................... 3.135V to 3.465V
(VDDIO @ 3.3V) ............................. 3.135V to 3.465V
(VDDIO @ 2.5V) ............................. 2.375V to 2.625V
(VDDIO @ 1.8V) ............................. 1.710V to 1.890V
Ambient Temperature (TA)
Commercial ...................................... 0°C to +70°C
Industrial ......................................... 40°C to +85°C
Maximum Junction Temperature (TJ) .................. 125°C
128-Pin Package Thermal Resistance(9)
PQFP Thermal Resistance JA) ........... 41.54°C/W
PQFP Thermal Resistance (θJC) ........... 19.78°C/W
LQFP Thermal Resistance (θJA) ............ 48.22°C/W
LQFP Thermal Resistance (θJC) ........... 13.95°C/W
Electrical Characteristics(10,11)
VIN = 1.2V/3.3V (typical); TA = 25°C
Symbol Parameter Condition Min. Typ. Max. Units
100BASE-TX OperationAll Ports 100% Utiliza tion
IDX 100BASE-TX (Transmitter) 3.3V Analog VDDAT 86 mA
IDda 100BASE-TX 1.2V Analog VDDAR 22 mA
IDDc 100BASE-TX 1.2V Digital VDDC 42 mA
IDDIO 100BASE-TX (Digital IO) Standalone 5-port VDDIO 2.4 mA
IDDIO 3.3V Digital IO SW5-MII MAC/PHY + P5-MII VDDIO 22/38 mA
IDDIO 3.3V Digital IO SW5-RMII + P5-RMII VDDIO 39 mA
10BASE-T Operation All Ports 100% Utilization
IDX 10BASE-T (Transmitter) 3.3V Analog VDDAT 107 mA
IDda 10BASE-T 1.2V Analog VDDAR 8.6 mA
IDDc 10BASE-T 1.2V Digital VDDC 44 mA
IDDIO 10BASE-TX (Digital IO) Standalone 5-port VDDIO 2.2 mA
IDDIO 3.3V Digital IO SW5-MII MAC/PHY + P5-MII VDDIO 5/18 mA
IDDIO 3.3V Digital IO SW5-RMII + P5-RMII VDDIO 29 mA
Notes:
7. Exceeding the absolute maximum rating may damage the device.
8. The device is not guarant eed to function outside its operat i ng rating. Unused inputs must al ways be tied to an appropriate logic volt age level
(ground or VDD).
9. No heat spreader in package. The thermal junction to ambient (θJA) and the thermal junction to case (θJC) are under air veloc ity 0m/s.
10. Specific at i on for pack aged product only. T here is no an additional transform er consumption due to use on chip termination technology with
internal biasing for 10Bese-T and 100Base-TX.
11. Measurem ents were taken with operating rati ngs.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 112 Revision 1.3
Electrical Characteristics(10,11) (Continued)
VIN = 1.2V/3.3V (typical); TA = 25°C
Symbol Parameter Condition Min. Typ. Max. Units
Auto-Negotiation Mode
IDX 10BASE-T (Transmitter) 3.3V Analog VDDAT 55 mA
IDda 10BASE-T 1.2V Analog VDDAR 22 mA
IEDM 10BASE-T 1.2V Digital VDDC 46 mA
IDDIO 10BASE-T (Digital IO) Standalone 5-Port VDDIO 1.5 mA
Power Manageme nt Mode (Standalone)
IHPDM1 Hardware Power-Down Mode 3.3V VDDAT + VDDIO 2 mA
IHPDM2 Hardware Power-Down Mode 1.2V VDDAR + VDDC 1 mA
IPSM1 Power-Saving Mode 3.3V VDDAT + VDDIO 35 mA
IPSM2 Power-Saving Mode 1.2V VDDAR + VDDC 55 mA
ISPDM1 Soft Power-Down Mode 3.3V VDDAT + VDDIO 2 mA
ISPDM2 Soft Power-Down Mode 1.2V VDDAR + VDDC 1.8 mA
IEDM1 Energy-Detect Mode + PLL OFF 3.3V VDDAT + VDDIO 5.5 mA
IEDM2 Energy-Detect Mode + PLL OFF 1.2V VDDAR + VDDC 1.5 mA
CMOS Inputs
VIH Input High Voltage
(VDDIO = 3.3/2.5/1.8V) 2.0/1.8/1.3 V
VIL Input Low Voltag e
(VDDIO = 3.3/2.5/1.8V) 0.8/0.7/0.5 V
IIN Input Current
(excluding Pull-up/Pull-down) VIN = GND ~ VDDIO 10 10 µA
CMOS Outputs
VOH Output High Voltage
(VDDIO = 3.3/2.5/1.8V) IOH = 8mA 2.4/2.0/1.5 V
VOL Output Low Voltage
(VDDIO = 3.3/2.5/1.8V) IOL = 8mA 0.4/0.4/0.3 V
IOZ Output Tri-State Leakage VIN = GND ~ VDDIO 10 µA
100BASE-TX/FX Transmit (measured differentially after 1:1 transformer)
VO Peak Differential Output Voltage 100Ω termination
on the differential
output 0.95 1.05 V
VIMB Output Voltage Imbalance 100Ω termination
on the differential
output 2 %
tr tt Rise/Fall Time 3 5 ns
Rise/Fall Time Imbalance 0 0.5 ns
Duty Cycle Distortion ±0.5 ns
Overshoot 5 %
Output Jitters Peak-to-peak 0 0.75 1.4 ns
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 113 Revision 1.3
Electrical Characteristics(10,11) (Continued)
VIN = 1.2V/3.3V (typical); TA = 25°C
Symbol Parameter Condition Min. Typ. Max. Units
100BASE-FX Receiver
VIST Input Signal Threshold Voltage 100Ω Impedance
on RX± 400 mV
VFXSD FXSD Signal-Detect Voltage Threshold
1.2V: FX signal
detect mode <1.2V:
Non-signal detect
mode
1.2 V
10BASE-T Receive
VSQ Squelch Threshold 5MHz square wave 300 400 585 mV
10BASE-T Transmit (measured differentially after 1:1 transformer) VDDAT = 3.3V
VP Peak Differential Output Voltage 100Ω termination
on the differential
output 2.2 2.5 2.8 V
Output Jitters Peak-to-peak 1.4 3.5 ns
Rise/fall Times 28 30 ns
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 114 Revision 1.3
Timing Diagrams
EEPROM Timing
Figure 19. EEPROM Interface Input Receive Timing Diagram
Figure 20. EEPROM Interface Output Transmit Timing Diagram
Table 23. EEPROM Timing Parameters
Symbol Parameter Min. Typ. Max. Units
tCYC1 Clock Cycle 16384 ns
tS1 Set-Up Time 20 ns
tH1 Hold Time 20 ns
tOV1 Output Valid 4096 4112 4128 ns
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 115 Revision 1.3
SNI Timing
Figure 21. SNI Input Timing
Figure 22. SNI Output Timing
Table 24. SNI Timing Parameters
Symbol Parameter Min. Typ. Max. Units
tCYC2 Clo ck Cycle 100 ns
tS2 Set-Up Time 10 ns
tH2 Hold Time 0 ns
tO2 Output Valid 0 3 6 ns
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 116 Revision 1.3
MII Timing
Figure 23. MAC Mode MII Timing Data Received from MII
Figure 24. MAC Mode MII Timing Data Transmitted from MII
Table 25. MAC Mode MII Timing Parameters
Symbol Parameter Min. Typ. 10Base-T/100Base-TX
Max.
Units
tCYC3 Clock Cycle
400/40
ns
tS3 Set-Up Time 10
ns
tH3 Hold Time 5
ns
tOV3 Output Valid 3 7 25 ns
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 117 Revision 1.3
MII Timing (Continued)
Figure 25. PHY Mode MII Timing Data Received from MII
Figure 26. PHY Mode MII Timing Data Transmitted from MII
Table 26. PHY Mode MII Ti mi ng Parameters
Symbol Parameter Min. Typ. 10BaseT/100BaseT
Max. Units
tCYC4 Clo ck Cycle 400/40 ns
tS4 Set-Up Tim e 10 ns
tH4 Hold Time 0 ns
tOV4 Output Valid 16 20 25 ns
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 118 Revision 1.3
RMII Timing
Figure 27. RMII Timing Data Received from RMII
Figure 28. RMII Timing Data Transmitted to RMII
Table 27. RMII Timing Parameters
Timing Parameter Description Min. Typ. Max. Unit
tcyc Clock cycle 20 ns
t1 Setup time 4 ns
t2 Hold time 2 ns
tod Output delay 3 14 ns
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 119 Revision 1.3
SPI Timing
Figure 29. SPI Input Timing
Table 28. SPI Input Timing Parameters
Symbol
Parameter
Min.
Typ.
Max.
Units
fC Clock Frequency 25 MHz
tCHSL SPIS_N Inactive Hold Time 10 ns
tSLCH SPIS_N Active Set-Up Time 10 ns
tCHSH SPIS_N Active Hold Time 10 ns
tSHCH SPIS_N Inactive Set-Up Time 10 ns
tSHSL SPIS_N Deselect Time 20 ns
tDVCH Data Input Set-Up Time 5 ns
tCHDX Data Input Hold Time 5 ns
tCLCH Clock Rise Time 1 µs
tCHCL Clock fall Time 1 µs
tDLDH Data Input Rise Time 1 µs
tDHDL Data Input fall Time 1 µs
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 120 Revision 1.3
SPI Timing (C on tinued)
Figure 30. SPI Output Timing
Table 29. SPI Output Tim in g Par ameter s
Symbol Parameter Min. Typ. Max. Units
fC Clock Frequency 25 MHz
tCLQX SPIQ Hold Time 0 0 ns
tCLQV Clock Low to SPIQ Valid 15 ns
tCH Clock High Time 18 ns
tCL Clock Low Time 18 ns
tQLQH SPIQ Rise Time 50 ns
tQHQL SPIQ fall Time 50 ns
tSHQZ SPIQ Disable Time 15 ns
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 121 Revision 1.3
Auto-Negotiation Timing
Figure 31. Auto-Negotiation Timing
Table 30. Auto-Negotiation Timing Parameters
Symbols Parameters Min. Typ. Max. Units
tBTB FLP burst to FLP burst 8 16 24 ms
tFLPW FLP burst width 2 ms
tPW Clock/Dat a pul se width 100 ns
tCTD Clock pulse to Data pulse 55.5 64 69.5 µs
tCTC Clock pulse to Clock pulse 111 128 139 µs
Number of Clock/Data pulse per burst 17 33
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 122 Revision 1.3
MDC/MDIO Timing
Figure 32. MDC/MDIO Timing
Table 31. MDC/MDIO Typical Timing Parameters
Timing Parameter Description Min. Typ. Max. Unit
tP MDC period 400 ns
t1MD1 MDIO (PHY input) setup to rising edge of MDC 10 ns
tMD2 MDIO (PHY input) hold from rising edge of MDC 4 ns
tMD3 MDIO (PHY output) delay from rising edge of MDC 222 ns
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 123 Revision 1.3
Reset Timing
Figure 33. Reset T iming
Table 32. Reset Timing Parameters
Symbol Parameter Min. Typ. Max. Units
tSR Stable Supply Voltages to Reset High 10 ms
tCS Configuration Set-Up Time 50 ns
tCH Configuration Hold Time 50 ns
tRC Reset to Strap-In Pin Output 50 ns
tvr 3.3V rise time 100 us
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 124 Revision 1.3
Reset Circuit Diagram
Micrel recommends the following discrete reset circuit as shown in Figure 34 for the power-up reset circuit.
KSZ8895
VDDIO
D1
D1: 1N4148
R 10K
C 10uF
RST#
Figure 34. Recommended Reset Circuit
Figure 35 shows a reset circuit recommended for applications where reset is driven by another device (for example,
the CPU or an F PGA). The reset out RST _OUT_n from C PU/FPGA provides the warm res et after power up r eset. D2
is required if using different VDDIO voltage between switch and CPU/FPGA. Diode D2 should be selected to provide
maxim um 0.3V VF ( Forward Vol tag e) , f or example, VI SHA Y B AT54, MS S1 P2L. Alt ernat iv ely, a le ve l sh if ter dev ice can
also be used. D2 is not required if switch and CPU/FPGA use same VDDIO voltage.
KSZ8895 CPU/FPGA
VDDIO
C 10uF
R 10K
RST_OUT_n
D1
D2
D1: 1N4148
RST#
Figure 35. Recommended Circuit for Interfacing with CPU/FPGA Reset
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 125 Revision 1.3
Selection of Isolation Transformer(12)
One sim ple 1:1 isolation transformer is needed at the line interface. An isolation transform er with integrated common-
mode choke is recommended for exceeding FCC requirements at line side. Request to separate the center taps of
RX/TX at chip side. Table 33 gives recommended transformer characteristics.
Table 33. Transformer Selection Criteria
Characteristics Name Value Test Condition
Turns Ratio 1 CT : 1 CT
Open-Circuit Inductance (minimum) 350µH 100mV, 100kHz, 8mA
Insertion Lo ss (maximum) 1.1dB 0.1MHz to 100MHz
HIPOT (minimum) 1500Vrms
Note:
12. The IEEE 802.3u standard for 100BASE -TX ass umes a transformer loss of 0.5dB. For the transmit li ne transform er, insert i on loss of up to 1.3dB
can be compensated by increasing the line drive current by means of reducing the ISET resist or value.
The following transformer vendors provide compatible magnetic parts for Micrel’s device:
Table 34. Qual ified Mag netic Vendors
Vendors and Parts Auto
MDIX Number
of Ports Vendors and Parts Auto
MDIX Number of
Ports
Pulse H1664NL Yes 4 Pulse H1102 Yes 1
Pulse H1164NL Yes 4 Bel Fuse S558-5999-U7 Yes 1
TDK TLA-6T718A Yes 1 YCL PT163020 Yes 1
LanKom LF-H41S Yes 1 Transpower HB726 Yes 1
Datatronic NT79075 Yes 1 Delta LF8505 Yes 1
Selection of Reference Crystal
Table 35. Typical Reference Crystal Characteristics
Chacteristics Value Units
Frequency 25.00000 MHz
Frequency tolerance (maximum) ±50 ppm
Load capacitan ce (maximum) 27 pF
Series resistance (ESR) 40
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 126 Revision 1.3
Package Information and Recommended Land Pattern(13)
128-Pin PQFP (MM)
Note:
13. Package information is correct as of the publication date. For updates and most current information, go to www.micrel.com.
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 127 Revision 1.3
Package Information and Recommended Land Pattern(13) (Continued)
128-Pin LQFP (MM)
Micrel, Inc.
KSZ8895MQX/RQX/FQX/ML
26, 2015 128 Revision 1.3
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131 USA
TEL +1 (408) 944-0800 FAX +1 (408) 474-1000 WEB http://www.micrel.com
Micrel, Inc. is a leading global manufacturer of IC solutions for the worldwide high
-
performance linear and power, LAN, and timing &
communications markets. The Company’s products include advanced mixed
-signal, analog & power semiconductors; high-
performance
communication, clock management,
MEMs-based clock oscillators & crystal-less clock generators,
Ethernet switches, and physical layer
transceiver ICs.
Company customers include leading manufacturers of enterprise, consumer, industrial, mobile, telecommunications,
autom
otive, and computer products. Corporation headquarters and state-of-the-art wafe
r fabrication faciliti es are located in San Jose, CA, with
regional sales and support offices and advanced technology design centers situated throughout the Americas, Europe, and Asia.
Additionally,
the Company maintains an extensive network of dist ri buto
rs and reps worldwide.
Micrel makes no represent ations or warranties with respect to the accuracy or c ompleteness of the inf
ormation furni shed in thi s data
she et. Thi s
information is not intended as a warranty and Micrel does not assume responsibility for
its use.
Micrel reserves the right to change circuitry,
specifications and descriptions at any time without notice.
No license, whether express, implied, arising by estoppel or otherwise, to any
intellectual property rights
is granted by this document. E
xcept as provided in Micrel’s terms and conditions of sale for such products, Micrel
assumes no liability whatsoever, and Micrel disclaims any express or implied warranty relating to the sale and/or use of Micrel products including
liability or warranties
relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright,
or other intellectual
property right.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a
product can reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for
surgical implant into the body or (b) support or sustain life, and whose failure to
perform can be reasonably expected to result in a significant
injury to the user. A Purchaser’s use or sale of Micrel Products for use in life support appliances, devices or s ystems is a Purchaser’s own risk
and Purchaser agrees to fully indem nify Micrel
for any damages resulting from such use or sale.
© 2014 Micrel, Incorporated.