Product data sheet
Miniature connectors
Product description M16 IP40 female cable connector, Contacts: 6 DIN, 4.0 - 6.0 mm, shieldable, solder, IP40
Area M16 IP40 series 581
Order number 99 2022 00 06
Security notices
The connector must not be plugged or unplugged under load. Non-observance and improper use can
result in personal injury.
The connectors have been developed for applications in plant engineering, control and electrical
equipment construction. The user is responsible for checking whether the connectors can also be used
in other areas of application.
To protect against unintentional opening of the connector, the thread between the housing and the
connector head must be secured with a suitable cyanoacrylate adhesive when used in circuits with
voltages dangerous to the touch. This does not apply to connectors used in SELV and PELV circuits
according to IEC 61140 (EN 61140, VDE 0140-1).
Connectors which are used in circuits with voltages dangerous to the touch may only be installed and
used by, or under the supervision of, persons with electrical engineering training, taking into account
the applicable regulations and standards.
The plug connector is not suitable for mains voltages Please observe the pollution degree and the
overvoltage category. For further information, please refer to the download center "Technical
Information".
To lock the cable connector with the device connector, the threaded ring is tightened "hand-tight"
(approx. 50 cNm).
Powered by TCPDF (www.tcpdf.org)