MIL-PRF-39012/19H
w/AMENDMENT 1
16
1/ If a connector manufacturer produces a connector which meets all the requirements for two or more
connector PIN’s (within the same series), the manufacturer may receive qualification approval for two
or more connector plus qualifying the one connector. It is not necessary that such connectors be in
the same group. Each connector, however, must be marked with its own appropriate PIN. For group
qualification, the connectors must be of similar design and be of the same materials and plating.
2/ For qualification retention, where more than one part is listed in a group in this column, data may be
supplied on any of those parts in order to retain qualification for those parts in the corresponding right
hand column. The part does not necessarily have to be the part initially qualified.
3/ Qualification by similarity may be given for the like styles of currently qualified TNC series connectors
with the approval of the qualifying and preparing activity. Similarity will include, cable accommodation,
materials and plating, assembly procedures and crimp tools/dies, as a minimum.
TABLE IlI. Category B – Non-field replaceable (special tools may be required).
Dash number
1/ 2/ 3/
Applicable cable
M17/ 4/ Dimensions
Inches
(millimeters)
maximum #
M39012/19B0003 028-RG058*
M39012/19B0004 084-RG223*
M39012/19B0005 111-RG303*
M39012/19B0006 060-RG142*@
29-RG59*Δ
030-RG062Δ
M39012/19B0007 97-RG210 Δ
M39012/19B0008 054-RG122
M39012/19B0012 90-RG71*Δ
M39012/19B0019 110-RG302*@Δ
A
1.625 (41.28)
1/ For cross-reference of PIN to superseded PIN or type designation, see table IV.
2/ For maintenance replacements for category B, see table V.
3/ Inactive for new design.
4/ The latest version of each cable shall be applicable.
# Dimensions are in inches. Metric equivalents are given for information only.
* Cable to be used when performing tests requiring cable except as in notes @ and Δ.
@ Cable to be used for the +200°C temperature cycling tests. This cable may be used for tests with the
approval of the Qualifying Activity.
Δ These are not 50 ohm cables; therefore, when attached to the specified connectors, VSWR, RF
leakage, and insertion loss are not applicable.
Not for Air Force, Army or Navy use. For OEM use only.
Source: http://assist.dla.mil -- Downloaded: 2021-01-21T07:43ZCheck the source to verify that this is the current version before use.