LF (ALF)
–2– ASCTB195E 201606-T
RATING
1. Coil data
2. Specifications
* Specifications will vary with foreign standards certification ratings.
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50μs according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
3. Switching capacity
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
(at 20°C 68°F)
Max. applied voltage
(at 20°C 68°F)
5V DC
70%V or less of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
180 mA 27.8Ω
900mW 110%V of
nominal voltage
6V DC 150 mA 40 Ω
9V DC 100 mA 90 Ω
12V DC 75 mA 160 Ω
18V DC 50 mA 360 Ω
24V DC 37.5mA 640 Ω
Characteristics Item Specifications
Contact
Arrangement 1 Form A
Contact resistance (Initial) Max. 100 mΩ (By voltage drop 6 V DC 1A)
Contact material AgSnO2 type
Rating
Nominal switching capacity (resistive load) 20A 250V AC
Max. switching power (resistive load) 6,250VA
Max. switching voltage 250V AC
Max. switching current 25A
Nominal operating power 900mW
Min. switching capacity (reference value)*1100mA, 5V DC
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 1,000 Vrms for 1 min. (Detection current: 10 mA)
Between contact and coil 5,000 Vrms for 1 min. (Detection current: 10 mA)
Surge breakdown voltage*2
(Between contact and coil) (Initial) 10,000 V
Operate time (at nominal voltage) (at 20°C 68°F)
(Initial) Max. 20 ms (excluding contact bounce time.)
Release time (at nominal voltage) (at 20°C 68°F)
(Initial) Max. 15 ms (excluding contact bounce time) (With diode)
Mechanical
characteristics
Shock resistance Functional 100 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10μs.)
Destructive 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.)
Vibration resistance Functional 10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10μs.)
Destructive 10 to 55 Hz at double amplitude of 1.5 mm
Expected life Mechanical (at 180 times/min.) Min. 2×106
Electrical (at 20 times/min.) Min. 105 (resistive load)
Conditions Conditions for operation, transport and storage*3Ambient temperature: –40°C to +60°C –40°F to +140°F,
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed 20 times/min. (at nominal switching capacity)
Unit weight Approx. 23 g .81 oz
Electrical Life
Resistive load
20 A, 250 V AC (cos
φ
= 1) Min. 105
(at 20 times/min.)
25 A, 250 V AC (cos
φ
= 1) Min. 104
(at 20 times/min.)
Compressor load Inrush 70 A (cos
φ
= 0.7), Steady 20 A (cos
φ
= 0.9)
250 V AC
Min. 105
(at 20 times/min.)
Inverter load
Inrush 200 A, Steady 20 A
100 V AC
Min. 3×104
(at 10 times/min.)
Inrush 100 A, Steady 10 A
200 V AC
Min. 3×104
(at 10 times/min.)