MOS FET Relays G3VM-62J1 137
MOS FET Relays
G3VM-62J1
MOS FET Relay Designed for Switching Minute
and
Analog Signals has 2 Channels and a 60-V Load
Voltage, 8-pin SOP Package.
Continuous load current of 400 mA.
Dielectric strength of 1,500 Vrms between I/O.
RoHS Compliant.
Application Examples
Broadband systems
Measurement devices
Data Loggers
Amusement machines
Note: The actual product is marked differently from the image shown
here.
List of Models
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Terminal Arrangement/Internal Connections (Top View)
Actual Mounting Pad Dimensions (Recommended Value, Top View)
Contact form Terminals Load voltage (peak value) Model Number per stick Number per tape
DPST-NO Surface-mounting
terminals
60 VAC G3VM-62J1 50 ---
G3VM-62J1(TR) --- 2,500
4.4
±
0.2
9.4
±
0.25
0.4
±
0.1
2.54
±
0.25
2.1 max.
0.1
±
0.1
7.0
±
0.4
0.5
±
0.3
0.15
G3VM-62J1
Note: The actual product is marked differently
from the image shown here. Weight: 0.2 g
8765
3421
G3VM-62J1
6 to 6.3
1.2
0.8
2.542.54
G3VM-62J1
138 MOS FET Relays G3VM-62J1
Absolute Maximum Ratings (Ta = 25°C)
Electrical Characteristics (Ta = 25°C)
Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item Symbol Rating Unit Measurement conditions
Input LED forward current IF50 mA
Repetitive peak LED
forward current
IFP 1 A 100 μs pulses, 100 pps
LED forward current
reduction rate
Δ IF/°C0.5 mA/°CT
a 25°C
LED reverse voltage VR5V
Connection temperature Tj125 °C
Output Load voltage (AC peak/DC) VOFF 60 V
Continuous load current IO400 mA
ON current reduction rate Δ ION/°C4.0 mA/°CT
a 25°C
Dielectric strength between input and
output (See note 1.)
VI-O 1,500 Vrms AC for 1 min
Operating temperature Ta40 to +85 °C With no icing or condensation
Storage temperature Tstg 55 to +125 °C With no icing or condensation
Soldering temperature (10 s) --- 260 °C 10 s
Note: 1. The dielectric strength between the input and
output was checked by applying voltage be-
tween all pins as a group on the LED side and
all pins as a group on the light-receiving side.
Item Symbol Mini-
mum Typical Maxi-
mum Unit Measurement
conditions
Input LED forward voltage VF1.0 1.15 1.3 V IF = 10 mA
Reverse current IR--- --- 10 μAV
R = 5 V
Capacity between terminals CT--- 30 --- pF V = 0, f = 1 MHz
Trigger LED forward current IFT --- 1.6 3 mA IO = 400 mA
Output Maximum resistance with output ON RON --- 1.0 2.0 ΩIF = 5 mA,
IO = 400 mA
Current leakage when the relay is open ILEAK --- 0.001 1.0 μAV
OFF = 60 V
Capacity between terminals COFF --- 130 --- pF V = 0, f = 1MHz
Capacity between I/O terminals CI-O --- 0.8 --- pF f = 1 MHz, Vs = 0 V
Insulation resistance RI-O 1,000 --- --- MΩVI-O = 500 VDC,
RoH 60%
Tu r n - O N t i m e tON --- 0.8 2.0 ms IF = 5 mA, RL = 200 Ω,
VDD = 20 V (See note 2.)
Turn-OFF time tOFF --- 0.1 0.5 ms
VOUT
IF
t
ON
t
OFF
10% 90%
I
F
(3)1
(4)2
8(6)
7(5)
R
L
V
DD
V
OUT
Item Symbol Minimum Typical Maximum Unit
Load voltage (AC peak/DC) VDD --- --- 48 V
Operating LED forward current IF57.525mA
Continuous load current (AC peak/DC) IO--- --- 400 mA
Operating temperature Ta 20 --- 65 °C
MOS FET Relays G3VM-62J1 139
Engineering Data
LED forward current vs.
Ambient temperature
IF - Ta
Continuous load current vs.
Ambient temperature
IO - Ta
LED forward current vs.
LED forward voltage
IF - VF
LED forward current I
F
(mA)
-20 0 20 40 60 80 100 120
0
20
40
60
80
100
Continuous load current I
O
(mA)
-20 0 20 40 60 80 100
0
100
200
300
400
500
LED forward current I
F
(mA)
Ta = 25
0.6 0.8 1 1.2 1.4 1.6 1.8
0.1
1
10
100
Ambient temperature Ta ()
Ambient temperature Taഒ
LED forward voltage V
F
(V)
Continuous load current vs.
On-state voltage
IO - VON
On-state resistance vs.
Ambient temperature
RON - Ta
Trigger LED forward current vs.
Ambient temperature
IFT - Ta
Continuous load current I
O
(mA)
-1.0 -0.5 0.0 0.5 1.0
-400
-200
0
200
400
On-state resistance R
ON
(Ω)
-20 0 20 40 60 80 100
0.0
0.5
1.0
1.5
2.0
Trigger LED forward current I
FT
(mA)
-20 0 20 40 60 80 100
0
1
2
3
4
5
On-state voltage V
ON
(V
)
Ambient temperature Ta ()
Ambient temperature Ta ()
Turn ON, Turn OFF time vs.
LED forward current
tON, tOFF - IF
Turn ON, Turn OFF time vs.
Ambient temperature
tON, tOFF - Ta
Current leakage vs.
Ambient temperature
I LEAK - Ta
Turn ON, Turn OFF time t
ON
, t
OFF
(μS)
110100
1
10
100
1000
10000
Turn ON, Turn OFF time t
ON
, t
OFF
(μS)
-40-20 0 20406080100
10
100
1000
Current leakage I
LEAK
(nA)
-40 -20 0 20 40 60 80 100
0.1
1
10
100
LED forward current I
F
(mA)
Ambient temperature Ta (ഒ
Ambient temperature Ta ()
IF=5mA
,
Ta= 2 5˚ C
IF=5mA , IO=400mA
t < 1s
IO=400mA
t
<
1s
R
L
= 200Ω
V
DD
= 20V, Ta=25˚C
tON
tOFF
tON
tOFF
R
L
= 200Ω
V
DD
= 20V, I
F
= 5mA
VOFF = 60V
MOS FET Relays G3VM-62J1
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.components.omron.com
Cat. No. X302-E-1 Printed in USA
OMRON ELECTRONIC
COMPONENTS LLC
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
12/10 Specifications subject to change without notice
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.