General Purpose Relays
1
SCHRACK
Datasheet Rev. HC1
Issued 2008/03
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
‘Schrack’ section.
Specifications subject to
change.
Miniature Power PCB RY II & RY II reflow-solderable
I1 pole 8 A, 1 CO or 1 NO or 1 NC contact
ILow component height 12.3 mm
I5 kV / 8 mm coil-contact
IReinforced insulation (protection class II)
IPinnings: 3.2 and 5 mm
Ireflow-solderable version
ISockets with PCB-type terminals
IEspecially suitable for resistive and inductive loads on NO and NC contacts
IPlastic materials according to IEC60335-1 (domestic appliances)
(not at reflow-solderable version)
IRoHS compliant (Directive 2002/95/EC) as per product date code 0403
Applications: heating control, interface technology, domestic appliances, timers,
temperature control
Approvals
VREG.-Nr. 5358, ZE214025
Technical data of approved types on request
Contact data
Contact configuration 1 CO or 1NO or 1NC
Contact set single contact
Type of interruption micro disconnection
Rated current 8 A
Rated voltage / max. switching voltage AC 250/400 VAC
Maximum breaking capacity AC 2000 VA
Contact material AgNi0,15, AgSnO2, AgCdO
Mechanical endurance 30x106cycles
Rated frequency of operation with / without load 6 / 1200 min-1
Contact ratings
Type Load Cycles
RY**1*** NO, 8 A, 250 VAC, resistive, 70°C 1x105
RY**1*** NC, 8 A, 250 VAC, resistive, 70°C 5x104
RY**(0,1,2)*** 8 A, 30 VDC, UL 508 3 x104
RY**(0,1,2)*** 0,28 A, 250 VDC, UL 508 3 x104
RY**(0,1,2)*** 1/2 HP, 240 VDC, UL 508
RY**(0,1,2)*** 1/4 HP, 120 VDC, UL 508
RY**(0)*** 8 A, 415 VAC, resistive, UL 508 6 x103
RY**(0,1,2)*** Pilot duty - B300, UL 508 6000
RY*** *** CO, 8 A, 250 VAC, resistive, 70°C 5x103
RY**1 *** 6(4)A, 250 VAC, 85°C, EN60730 1x105
Coil data
Rated coil voltage range DC coil 5...60 VDC
Coil power DC coil typ. 220 mW
Operative range 2
Coil versions, DC-coil
Coil Rated Operate Release Coil Rated coil
code voltage voltage voltage resistance power
VDC VDC VDC Ohm mW
005 5 3,5 0,5 112+10% 223
006 6 4,2 0,6 162+10% 222
009 9 6,3 0,9 320+10% 253
012 12 8,4 1,2 627+10% 230
024 24 16,8 2,4 2350+10% 245
048 48 33,6 4,8 9391+10% 245
060 60 42,0 6,0 14000+10% 257
All figures are given for coil without preenergization, at ambient temperature +23°C
Other coil voltages on request
F0142-F