SCA3000-E04
VTI Technologies Oy 2/4
www.vti.fi Doc. Nr. 8290500B.0 Rev.B.0
Performance Characteristics 1)
Typical supply range
2.35 – 2.7 V
Extended supply
range 2.7 – 3.6 V
Parameter
Condition
Min Typ 2) Max Min Typ 2) Max
Units
Analog and digital Vdd 2.35 2.5 2.7 - 3.3 - V
Digital I/O Vdd Vdd ≥ Digital I/O Vdd 1.7 1.8 / 2.5 2.7 - 3.3 - V
Operating temperature ** -40 - 85 -40 - 85 °C
Current consumption * Reset 3) - <7 12 - <9 - µA
Active - 120 145 - 150 - µA
Motion Detection
mode
- 120 145 - 150 - µA
Acceleration range * 4) Nominal -6 - 6 - ± 6 - g
Offset calibration error * Z-axis +1g position -80 - 80 - ± 200 - mg
Offset temperature error ** 5) -40 ... +85 °C -9 ±1.6 9 - ±1.6 - mg/°C
Sensitivity * 6) - 500 - - 500 - Count/g
Sensitivity calibration error * -3 - +3 - ± 3 - %
Sensitivity temperature error
** 7)
-40 ... +85 °C -0.05 ±0.015 0.05 - ±0.015 - %/°C
Non-Linearity ** 8) -3 ±1 3 - ±1 - % FS
Cross-Axis sensitivity ** 9) - ±4 - - ±4 - %
Bandwidth ** 10) Measurement mode 30 38 46 - 38 - Hz
Narrow band
measurement mode
7 9 11 - 9 - Hz
Wide band
measurement mode
50 70 100 - 70 - Hz
Noise ** 11) Measurement mode - 18 36 - 18 - mg RMS
Narrow band
measurement mode
- 10 20 - 10 - mg RMS
Wide band
measurement mode
- 30 60 - 30 - mg RMS
Output data rate ** Measurement mode 80 100 120 - 93 - Hz
Narrow band
measurement mode
40 50 60 - 45 - Hz
Wide band
measurement mode
320 400 480 - 400 - Hz
Turn on time ** 12) Measurement mode - 35 70 - 35 - ms
Narrow band
measurement mode
- 200 400 - 200 - ms
Wide band
measurement mode
- 20 40 - 20 - ms
Output load ** - - 35 - - 35 pF
SPI clock rate ** - - 325 - - 325 kHz
* 100% tested in production
** Qualified during product validation
1) The product is factory calibrated at 2.5 V in room temperature.
2) Typical values are not guaranteed.
3) Includes the current through the internal 400 kΩ pull-up resistor connected to digital I/O Vdd.
4) Range defined as g
z
y
x6
2
2
2≤++ . The measuring range is tested on sensing element level. FS = 6g.
5) Offset temperature error = {Count(0g)-Offset} / Sensitivity [ g ]. Sensitivity = Calibrated sensitivity.
Offset= Calibrated offset.
6) Sensitivity = {Count(+1g) - Count(-1g)}/2 [Count/g].
7) Sensitivity temperature error = {[Count(+1g)-Count(-1g)]/2 - Sensitivity} / Sensitivity x 100% [%].
Sensitivity = Calibrated sensitivity.
8) Best fit straight line.
9) The cross-axis sensitivity determines how much acceleration, perpendicular to the measuring axis,
couples to the output. The total cross-axis sensitivity is the geometric sum of the sensitivities of
the two axes which are perpendicular to the measuring axis. The angular alignment error
between X, Y and Z axis is included into the cross axis sensitivity.
10) Frequency responses according to Figure 3, Figure 4 and Figure 5.