GBU804G ........ GBU807G
Maximum Ratings and Electrical Characteristics at 25 ºC
Current
8.0 A
Voltage
400 V to 1000 V
MECHANICAL DATA
GBU

Ideal for printed circuit board
UL recognition file number
E320541
High case dielectric strength of 1500 Vrms
TYPICAL APPLICATIONS
Used in ac-to-dc bridge full wave rectification for monitor,
TV, printer, switching mode power supply, adapter, audio
equipment, and home appliances applications.
FEATURES
High surge current capability
Solder dip 260ºC, 10s
Component in accordance to RoHS 2002/95/EC
and WEEE 2002/96/EC
V
RRM
Maximum Recurrent Peak Reverse Voltage (V)
Maximum RMS Voltage (V)
I
FSM
Peak Forward Surge Current, 8.3 ms Single
Half Sine-wave Superimposed on Rated
Load (JEDEC Method)
V
DC
Maximum DC Blocking Voltage (V)
200 A
V
RMS
T
j
Operating Temperature Range -55 to +150 °C
I
F(AV)
Maximum Average Forward Rectified
Current @ TC = 60 °C
@ TA = 25 °C 8.0 A
3.0 A
T
stg
Storage Temperature Range -55 to +150 °C
Electrical Characteristics at Tamb = 25 °C
1.0 V
V
F
Maximum Instantaneous Forward Voltage drop
per leg @ = 4.0 A
I
R
5.0 µA
500 µA
400
400
280
600
600
420
800
800
560
1000
1000
700
GBU
804G
GBU
805G
GBU
806G
GBU
807G
21 °C/W
Rth (j-a)
Rth (j-c) 4.0 °C/W
Cj
Typical Junction capacitance per leg (Note 3) 211pF 94pF
Marking Code
GBU804G GBU805G GBU806G GBU807G
8.0 Amp. Glass Passivated Single Phase In Line GBU Bridge Rectifier
Typical Thermal Resistance
(Note 2)
Maximum DC Reverse Current @ TA = 25 °C
at Rated DC Blocking Voltage @ TA =125°C
(Note 1)
www.fagorelectronica.com
Document Name: gbu8g Version: Oct-11
Page Number: 1/4

Case: GBU. Epoxy meets UL 94V-0 flammability rating.

Polarity:
As marked on body.

Mounting Torque:
10cm-kg (8.8 in.- Ibs.) Max.

Recommended Torque:
5.5cm-kg (5 in.- Ibs.)

Terminals:
Matte tin plated leads, solderable per
MIL-STD-750 Method 2026, J-STD-002 and JESD22-B102.
Consumer grade, meets JESD 201 class 1A whisker test
Notes: 1. Pulse Test with PW=300 µsec, 1% Duty Cycle.
2. Mounted on Al. Plate of 4" x 6" x 0.25" Al-Plate Heat sink.
3. Measured at 1.0MHZ and Applied Reverse Voltage of 4.0 Volts. D.C.
GBU806G TU
Package Outline Dimensions
:
(mm) GBU
GBU804G ........ GBU807G
Ordering information
TU TUBE 20 3.85
8.0 Amp. Glass Passivated Single Phase In Line GBU Bridge Rectifier
www.fagorelectronica.com
Document Name: gbu8g Version: Oct-11
Page Number: 2/4
PREFERRED P/N PACKAGE CODE DELIVERY MODE BASE QUANTITY UNIT WEIGHT (g)
Marking code
TYP.
2.03
1.65
4.1
3.5
1.27
1.02
3.2x45°
CHAMFER
5.33
4.83
2.54
2.16
1.9 R
0.5R (TYP.)
7.90
7.40
2.03
1.52
3.56
3.30
22.3
21.8
2.16
1.90
0.56
0.46
18.8
18.3
18.0
17.5
2.16
1.65
MC
Week code
Year code
WWY
GBU804G ........ GBU807G
Ratings and Characteristics (Ta 25 ºC unless otherwise noted)
FIG.2- TYPICAL REVERSE CHARACTERISTICS
PER BRIDGE ELEMENT
FIG.3- MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT PER BRIDGE ELEMENT
FIG.5- TYPICAL FORWARD CHARACTERISTICS
PER BRIDGE ELEMENT
FIG.4- TYPICAL JUNCTION CAPACITANCE
FIG.1- MAXIMUM FORWARD CURRENT DERATING
CURVE
050 100 150
0
2.0
4.0
6.0
8.0
25 75 125
Heatsink Mounting, T
C
P.C.B. Mounting, T
A
AMBIENT TEMPERATURE. (ºC)
AVERAGE FORWARD CURRENT.(A)
110 100
0
50
100
150
200
250
T
J
= 150 °C
8.3 ms Single Half Sine-Wave
NUMBER OF CYCLES AT 60Hz
PEAK FORWARD SURGE CURRENT.(A)
0.4 0.6 0.8 1.0 1.2 1.4 1.6
0.01
1
100
10
0.1
T
J
= 25 °C
Pulse Width = 300 µs
1 % Duty Cycle
INSTANTANEOUS FORWARD CURRENT.(A)
INSTANTANEOUS FORWARD VOLTAGE. (V)
0.1 110 100
10
100
1000
400 V
600 - 1000 V
T
J
= 25 °C
f = 1.0 MHz
V
sig
= 50 mVp-p
JUNCTION CAP
ACITANCE.(pF)
REVERSE VOLTAGE. (V)
020 40 100
0.01
0.1
1
10
100
60 80
1000
400 V
600 - 1000 V
TJ = 150 °C
TJ = 125 °C
TJ = 25 °C
INSTANTANEOUS REVERSE CURRENT (µA)
PERCENT OF RATED PEAK REVERSE VOLTAGE. (%)
8.0 Amp. Glass Passivated Single Phase In Line GBU Bridge Rectifier
www.fagorelectronica.com
Document Name: gbu8g Version: Oct-11
Page Number: 3/4
GBU804G ........ GBU807G
Disclaimer
8.0 Amp. Glass Passivated Single Phase In Line GBU Bridge Rectifier
www.fagorelectronica.com
Document Name: gbu8g Version: Oct-11
Page Number: 4/4
All product, product specifications and data are subject to change without notice to improve reliability,
function or design or otherwise.
Fagor Electrónica, S.Coop., its affiliates, agents, and employees, and all persons acting on its or their
behalf (collectively, "Fagor"), disclaim any and all liability for any errors, inaccuracies or incompleteness contained
in any datasheet or in any other disclosure relating to any product.
Fagor makes no warranty, representation or guarantee regarding the suitability of the products for any particular
purpose or the continuing production of any product. To the maximum extent permitted by applicable law,
Fagor disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all
liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied
warranties, including warranties of fitness for particular purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Fagor's knowledge
of typical requirements that are often placed on Fagor products in generic applications. Such statements are not
binding statements about the suitability of products for a particular application. It is the customer's responsibility
to validate that a particular product with the properties described in the product specification is suitable for use in a
particular application. Parameters provided in datasheets and/or specifications may vary in different applications
and performance may vary over time. All operating parameters, including typical parameters, must be validated
for each customer application by the customer's technical experts. Product specifications do not expand or
otherwise modify Fagor's terms and conditions of purchase, including but nos limited to the warranty expressed
therein.
Except as expressly indicated in writing. Fagor products are not designed for use in medical, life-saving, or
life-sustaining applications or for any other application in which the failure of the Fagor product could result in
personal injury or death. Customers using or selling Fagor products not expressly indicated for use in such
applications do so at their own risk and agree to fully indemnify and hold Fagor and its distributors harmless from
and against any and all claims, liabilities, expenses and damages arising or resulting in connection with such use
or sale, including attomeys fees, even if such claim alleges that Fagor or its distributor was negligent regarding
the design or manufacture of the part. Please contact authorized Fagor personnel to obtain written terms and
conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this
document or by any conduct of Fagor, Product names and markings noted herein may be trademarks of their
respective owners.