12
-
152
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.200.01.T.E
January 2001
12
Direct Current Circuit Breakers
Vol. 1, Ref. No. [0618]
Product Selection
Table 12-273. Type HFDDC DC Circuit Breakers
Note: Instruction Leaflet/FRED Number 29C700
Table 12-274. Type HJDDC DC Circuit Breakers
Complete circuit breaker includes frame, trip unit and terminals.
Note: Instruction Leaflet/FRED Number 29C701 and 29C702
Maximum
Continuous
Ampere Rating
@ 40°C
Complete Circuit Breaker with Line and Load Terminals
1-Pole 2-Pole 3-Pole
Catalog
Number
Price
U.S. $
Catalog
Number
Price
U.S. $
Catalog
Number
Price
U.S. $
1, 2, 3-Pole High Interrupting Capacity 35 kAIC @ 600V DC
15
20
25
30
35
HFDDC1015L
HFDDC1020L
HFDDC1025L
HFDDC1030L
HFDDC1035L
285.00
285.00
285.00
285.00
285.00
HFDDC2015L
HFDDC2020L
HFDDC2025L
HFDDC2030L
HFDDC2035L
840.00
840.00
840.00
840.00
840.00
HFDDC3015L
HFDDC3020L
HFDDC3025L
HFDDC3030L
HFDDC3035L
1,090.00
1,090.00
1,090.00
1,090.00
1,090.00
40
45
50
60
70
HFDDC1040L
HFDDC1045L
HFDDC1050L
HFDDC1060L
HFDDC1070L
285.00
285.00
285.00
285.00
379.00
HFDDC2040L
HFDDC2045L
HFDDC2050L
HFDDC2060L
HFDDC2070L
840.00
840.00
840.00
840.00
1,080.00
HFDDC3040L
HFDDC3045L
HFDDC3050L
HFDDC3060L
HFDDC3070L
1,090.00
1,090.00
1,090.00
1,090.00
2,980.00
80
90
100
110
125
HFDDC1080L
HFDDC1090L
HFDDC1100L
HFDDC1110L
HFDDC1125L
379.00
379.00
379.00
379.00
379.00
HFDDC2080L
HFDDC2090L
HFDDC2100L
HFDDC2110L
HFDDC2125L
1,080.00
1,080.00
1,080.00
1,080.00
1,080.00
HFDDC3080L
HFDDC3090L
HFDDC3100L
HFDDC3110L
HFDDC3125L
2,980.00
2,980.00
2,980.00
2,980.00
2,980.00
150
175
200
225
HFDDC1150L
379.00
HFDDC2150L
1,080.00
HFDDC3150L
HFDDC3175L
HFDDC3200L
HFDDC3225L
2,980.00
3,135.00
3,135.00
3,135.00
Maximum
Continuous
Ampere Rating
@ 40°C
Circuit Breaker
Frame Only Thermal Magnetic
Trip Unit
Standard
Terminals
Catalog
Number
Price
U.S. $
Catalog
Number
Price
U.S. $
Catalog
Number
Price
U.S. $
3-Pole High Interrupting Capacity 35 kAIC @ 600V DC
70
90
100
125
150
175
200
225
250
HJDDC3250F 3,040.00 JT3070T
JT3090T
JT3100T
JT3125T
JT3150T
JT3175T
JT3200T
JT3225T
JT3250T
595.00
595.00
595.00
595.00
595.00
595.00
595.00
595.00
1,710.00
TA250KB
TA250KB
TA250KB
TA250KB
TA250KB
TA250KB
TA250KB
TA250KB
TA250KB
22.40
22.40
22.40
22.40
22.40
22.40
22.40
22.40
22.40
100
125
150
175
200
225
HKDDC3400F 4,070.00 KT3100T
KT3125T
KT3150T
KT3175T
KT3200T
KT3225T
625.00
625.00
625.00
625.00
625.00
625.00
TA300K
TA300K
TA300K
TA300K
TA300K
TA300K
22.40
22.40
22.40
22.40
22.40
22.40
250
300
350
400
HKDDC3400F 4,070.00 KT3250T
KT3300T
KT3350T
KT3400T
625.00
625.00
625.00
625.00
TA350K
TA350K
TA350K
3TA400K
22.40
22.40
22.40
66.00
300
350
400
450
500
600
HLDDC3600F 5,420.00 LT3300T
LT3350T
LT3400T
LT3450T
LT3500T
LT3600T
1,665.00
1,665.00
1,665.00
1,665.00
1,665.00
1,665.00
TA602LD
TA602LD
TA602LD
TA602LD
TA602LD
3TA603LDK
29.50
29.50
29.50
29.50
29.50
93.00
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . CB-2
CAT.200.01.T.E For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
12
-
1
January 2001 Direct Current Circuit Breakers
Vol. 1, Ref. No. [0617]
Contents
Description Page
Direct Current
Circuit Breakers
Product Description . . . . . . 12-151
Technical Data
and Specifications . . . . . . 12-151
Wiring Diagrams . . . . . . . . 12-151
Product Selection. . . . . . . . 12-152
Product Description
UL listed DC Molded Case Circuit
Breakers for use in general DC circuits
and ungrounded battery supply circuits
of UPS systems providing continuous,
reliable AC power to computer con-
trolled applications such as financial
transactions and telecommunications.
For standard interrupting capacity
250 DC molded case circuit breakers.
Refer to Table 12-1.
The Series C DC breakers listed below
use the same internal and external
accessories as the standard Series C
breaker. NBDC and PBDC use same
internal and external accessories as
standard NB and PB breakers.
Molded case circuit breakers for trans-
portation application requiring 750V DC
are available 15 – 2500 ampere 20 kA
interrupting capacity at 750V DC.
Breakers require 4 poles in series for
750V DC application. However, 750V is
not a UL rating. For 750V DC application
refer to Cutler-Hammer for ordering
information. Dimensions are the same
as the standard thermal-magnetic
equivalent.
Technical Data
and Specifications
Interrupting Capacity Ratings
Table 12-272. UL489 Interrupting
Capacity Ratings
DC ratings apply to substantially non-
inductive circuits. 8 millisecond time constant.
1 pole in series.
2 poles in series.
3 poles in series.
4 poles in series. Not a UL listed voltage
rating.
Wiring Diagrams
Figure 12-30. Series Connection Diagrams for DC Application
Note: Use rated cable per NEC Connect to terminals as per breaker nameplate.
Circuit
Breaker
Type
Interrupting Capacity
(Symmetrical kA)
Volts DC
125 250 600 750
HFDDC
HJDDC
HKDDC
HLDDC
HMDLDC
NBDC
PBDC
42
42
42
42
42
50
75
42
42
42
42
42
50
75
35
35
35
35
35
50
75
20
20
20
20
20
20
20
Load
Load
Load
600V DC
3 Poles in Series
750V DC
4 Poles in Series