The BXA40 Series providing up to 40 Watts, has been conceived as
an applications specific range of dc-dc converters, specifically
addressing telecommunications, industrial electronics, test
equipment, mobile telecommunications and distributed power
applications. The series offers two wide input voltage ranges, 18
Vdc to 36 Vdc and 36 Vdc to 75 Vdc, and is available with single
outputs from 2.9 V to 12 V. The BXA40 series is designed to meet
ETSI telecoms interface standards ETS300-132-2. Together with
internal filtering, safety approval to IEC950 and basic insulation,
the 48 V models are ideal for telecommunications applications.
The 24 V models are particularly suited to industrial and test
equipment applications, featuring EN61000-4-2, -3, -4, -5 and -6
immunity compliance. Other features include low output ripple,
overvoltage protection, indefinite short circuit protection, remote
enable and remote sense.
Embedded Power for
Business-Critical Continuity
BXA40 Series
Single output
Special Features
Pin-compatible with
NFC40 Series
Meets telecom power supply
interface standard
ETS300-132-2
EN60950, CSA C22.2 No. 950
and UL1950 safety approvals
EN61000-4-2, -3, -4, -5, -6
immunity compliant
Fixed frequency operation at
350 kHz typ.
MTBF in excess of
500,000 hours
Basic insulation system with
1500 Vdc isolation
Remote sense on low voltage
logic outputs
Output voltage trim
Available RoHS compliant
2 year warranty
Total Power: 40W
Input Voltage: 18 - 36VDC
36 - 75VDC
# of Outputs: Single
Safety
VDE0805/EN60950/IEC950
File No. 14501-3336-7009
Licence No. 6296
UL1950 File No. E174104
CSA C22.2 No. 950
File No. LR41062C
Rev.03.08.07
bxa40s
1 of 4
Rev.03.08.07
bxa40s
2 of 4
Embedded Power for
Business-Critical Continuity
All specifications are typical at nominal input, full load at 25°C unless otherwise stated.
Specifications
EMC CHARACTERISTICS
Conducted emissions EN55022, FCC part 15, Level B
(See Notes 4 and 13)
Radiated emissions EN55022, FCC part 15 Level A
ESD air EN61000-4-2, level 3 Perf. criteria 1
ESD contact EN61000-4-2, level 4 Perf. criteria 1
Surge EN61000-4-5, level 3 Perf. criteria 1
Fast transients EN61000-4-4, level 3 Perf. criteria 1
Radiated immunity EN61000-4-3, level 3 Perf. criteria 1
Conducted immunity EN61000-4-6, level 3 Perf. criteria 1
GENERAL SPECIFICATIONS
Efficiency See table
Isolation voltage Input/output 1500 Vdc
Input/case 1500 Vdc
Switching frequency Fixed 350 kHz typ.
Approvals and EN60950, UL1950
standards CSA C22.2 No. 950
Case material Aluminum substrate
with plastic case
Material flammability UL94V-0
Weight 85 g (3.0 oz)
MTBF MIL-HDBK-217F 500,000 hours
Size 2.2 x 2.2 x 0.5 inches
55.9 x 55.9 x 12.7 mm
ENVIRONMENTAL SPECIFICATIONS
Thermal performance Baseplate operating -40 °C to +105 °C
temperature
Non-operating -55 °C to +105 °C
Thermal impedance No air flow, no heatsink 8.5 °C/W
(See Note 6) No air flow, with heatsink 7.2 °C/W
OUTPUT SPECIFICATIONS
Voltage adjustability ±10%
Line regulation Low line to high line ±0.3%
Load regulation Full load to no load ±1.0%
Ripple and noise 2.9 V and 3.3 V 30 mV pk-pk
(20 MHz bandwidth) 5 V 50 mV pk-pk
12 V 100 mV pk-pk
All models 20 mV rms
Temperature coefficient ±0.02%/°C
Overvoltage protection (See Note 9) 135% Vout
Short circuit protection (See Note 10) Continuous
Transient response 25% to 100% load 4.0%
(See Note 11)
Voltage accuracy ±1.0% ≤5 V, ±2.0% ≥12 V
Remote sense Compensated line drops
(See Note 8) up to 0.5 V on 5 V models
Compensated line drop up to
300 mV on 2.9 V and 3.3 V models
INPUT SPECIFICATIONS
Input voltage range 24 Vin nominal 18-36 Vdc
48 Vin nominal 36-75 Vdc
Reverse voltage (See Note 5)
protection
Max. input rise and 48 V 5 V/ms
fall time ETS300-132
Start-up time 30 ms typ.
Remote ON/OFF
Logic compatibility CMOS/TTL
ON Open-circuit
OFF <1 Vdc
Rev.03.08.07
bxa40s
3 of 4
Embedded Power for
Business-Critical Continuity
Specifications Contd.
Notes
1Nominal line, at no load.
2Low line to high line at full load.
3Full load to no-load at nominal line.
4For conducted noise operation of the BXA40 to VDE0871, VDE0878 and
EN55022 level B, see BXA40 Design Note 101.
5Reverse voltage protection can be implemented by putting a slow blow fuse on
the positive input rail. Rate the fuse at 200 Vdc,1.5 A for 48 Vdc inputs and 100
V, 4.5 A for 24 Vdc input units.
6The maximum operating ambient temperature, without derating depends on
internal power dissipation and hence efficiency and cooling method. Download
BXA40 Design Note 101 which provides detailed thermal calculations and
design-in hints from the Artesyn website.
7Do not exceed a dv/dt rate of 100 V per second at the trim pin input if output
current is less than 0.4% lo max.
8Remote sense is offered as standard on the 2.9 V and 3.3 V products. The
BXA40-24S05J and BXA40-48S05J come with remote sense as an option.
Remote sense design is designated by the suffix ‘-S’ e.g. BXA40-48S05-SMJ (for
units with metric inserts), BXA40-48S05-SJ (for units with imperial inserts). For
models without remote sense option, pin 5 and pin 6 are absent.
9Overvoltage protection is 118% on 3.3 V output model.
10 For 2.9 V output, no short circuit protection above 90 °C baseplate temp.
11 Transient response, 25% to 100% load, 10% for 2.9 V and 3.3 V models.
12 Units with the suffix ‘-M’ at the end of the model number are offered as
standard with metric threaded inserts (M3). To order units with imperial
threaded inserts (4-40 UNC) please remove the suffix ‘-M’ from the model
number. These inserts are used for bolting the unit to a PCB and/or fixing
heatsinks.
13 An external filter capacitor is necessary for safe operation of the 24 V input
models. It is also suggested that an external filter capacitor be used on the 48 V
input models. A 4 μF (or greater) film capacitor such as: ITW Paktron Capstick
series, part number 405K100CS4 4 μF/100 V is recommended, if filtering is not
used. See BXA40 Design Note 101.
14 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special
request, please contact your local sales representative for details.
15 NOTICE: Some models do not support all options. Please contact your local
Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
INPUT OUTPUT OUTPUT INPUT TYPICAL REGULATION MODEL
VOLTAGE VOLTAGE CURRENT (MAX.) CURRENT (1) EFFICIENCY LINE (2) LOAD (3) NUMBER (12,14,15)
18-36 Vdc 3.3 V 7 A 70 mA 75% 0.3% 1.0% BXA40-24S3V3-SMJ (8)
18-36 Vdc 5 V 8 A 40 mA 81% 0.3% 1.0% BXA40-24S05-MJ (8)
36-75 Vdc 2.9 V 6.9 A 40 mA 77% 0.3% 1.0% BXA40-48S2V9-SMJ (8)
36-75 Vdc 5 V 8.0 A 30 mA 82% 0.3% 1.0% BXA40-48S05-MJ (8)
36-75 Vdc 12 V 3.3 A 30 mA 87% 0.3% 1.0% BXA40-48S12-MJ
PIN CONNECTIONS
PIN NUMBER SINGLE OUTPUT
1 + Input
2 – Input
3 Control
4 No Connection
5 - Sense (8)
6 + Sense (8)
7+ Output
8 Common
9Trim
10KΩ
TRIMPOT
TRIM
DOWN
TRIM
UP
7
9
8
7
9
8
RT1
OR
RT2
EXTERNAL OUTPUT TRIMMING
Output can be externally trimmed
by ±10% using either method shown below.
Embedded Power for
Business-Critical Continuity
Rev.03.08.07
bxa40s
4 of 4
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2007 Emerson Electric Co.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
EmersonNetworkPower. com
AC Power
Connectivity
DC Power
Embedded Power
Inbound Power
Integrated Cabinet Solutions
Outside Plant
Precision Cooling
Site Monitoring and Services
Americas
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
16th - 17th Floors, Lu Plaza
2 Wing Yip Street, Kwun Tong
Kowloon, Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.powerconversion.com
technicalsupport@powerconversion.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
BOTTOM VIEW
ALL DIMENSIONS IN INCHES (mm)
0.3
(7.62)
0.019
(0.50)
0.50
(12.70) 0.15
(3.90)
321
98 76 5 4
2.20 ±0.02
(
5
5
.
9
0 ±0.50
)
1.90
(
4
8
.
2
6
)
1.80
(
4
5
.
7
2
)
0.15
(
3
.
8
2
)
0.05
(
1
.
2
7
)
0.2
(5.08)
0.1
(2.54)
0.6
(15.24)
0.8
(20.32) 0.5
(12.70)
0.2
(5.08)
0.60
(15.24)
1.25
(31.76)
1.90
(48.26)
0.15
(3.82)
0.256 (6.50) Diameter
Stand-off (4 Places)
Metric (Suffix '-M'):
M3 Tap Thru. 4 places or
Imperial (No '-M' suffix) 4-
40 UNC (Optional)
0.043 ±0.003(1.02 ±0.05)
Diameter Typ.
TOLERANCE : ± 0.004 (0.1)
(Unless otherwise specified)
2.20 ±0.02
(
5
5
.
9
0 ±0.50
)