TS-3000 3000W True Sine Wave DC-AC Inverter series Features : True sine wave output (THD<3%) High surge power up to 6000W High efficiency up to 92% Power ON-OFF switch Standby saving mode can be selectable Front panel indicator for operation status Thermostatically controlled cooling fan Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp. / Output short / Input polarity reverse / Overload / AC circuit breaker Application : Home appliance, power tools, office and portable equipment, vehicle and yacht ...etc. Optional monitoring software and connection cable (MW order No.: DS-TN-1500) E13 3 years warranty SPECIFICATION MODEL TS-3000-112 RATED POWER (Typ.) TS-3000-124 TS-3000-148 TS-3000-212 TS-3000-224 TS-3000-248 3000W MAXIMUM OUTPUT POWER (Typ.) 3450W for 180 sec. / 4500W for 10 sec. / surge power 6000W for 30 cycles Factory setting set at 110VAC AC VOLTAGE OUTPUT FREQUENCY WAVEFORM 200 / 220 / 230 / 240VAC selectable by setting button S.W 600.1Hz 500.1Hz 50/60Hz selectable by setting button S.W AC REGULATION (Typ.) 3% SAVING MODE (Typ.) Default disabled. Load5W will be changed to standby mode FRONT PANEL INDICATOR Battery voltage level, output load level, saving mode, fault and operation status BAT. VOLTAGE 12V DC CURRENT (Typ.) 50/60Hz selectable by setting button S.W Note.7 True sine wave (THD<3%) VOLTAGE RANGE (Typ.) Note.3,6 10.5 ~ 15VDC INPUT Factory setting set at 230VAC 100 / 110 / 115 / 120VAC selectable by setting button S.W Note.4 300A 24V 48V 12V 24V 48V 21 ~ 30VDC 150A 42 ~ 60VDC 75A 10.5 ~ 15VDC 21 ~ 30VDC 42 ~ 60VDC 300A 150A 75A 91% 89% 91% 92% 20A*6 45V 40A*12 11.3V 40A*6 22.5V 20A*6 45V 42V 10.5V 21V 42V 85 5 80 5 75 5 75 5 NO LOAD DISSIPATION (Typ.) 10W @ standby saving mode OFF MODE CURRENT DRAW (Typ.) 1mA EFFICIENCY (Typ.) Note.1 88% 90% Open & sealed lead acid battery BATTERY TYPES FUSE 40A*12 40A*6 BATTERY BAT. LOW ALARM 22.5V Note.6 11.3V INPUT 21V PROTECTION BAT. LOW SHUTDOWN Note.6 10.5V By internal fuse open REVERSE POLARITY 90 5 OVER TEMPERATURE OUTPUT SHORT OUTPUT PROTECTION OVER LOAD (Typ.) Protection type : Shut down o/p voltage, re-power on to recover 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. Protection type : Shut down o/p voltage, re-power on to recover CIRCUIT BREAKER GFCI PROCTECTION WORKING TEMP. ENVIRONMENT AC output receptacle:15A Optional (Only type F) WORKING HUMIDITY 20% ~ 90% RH non-condensing STORAGE TEMP., HUMIDITY VIBRATION -30 ~ +70 / -22 ~ +158oF, 10 ~ 95% RH LVD WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY CONTROL WIRING OTHERS NOTE DIMENSION PACKING None Note.2 0 ~ +40 @ 100% load ; 60 @ 50% load SAFETY STANDARDS SAFETY & EMC 85 5 Protection type : Shut down o/p voltage, re-power on to recover 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes None UL458 (only for Type G ) EN60950-1 None Bat I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC Bat I/P - AC O/P, Bat I/P - FG, AC O/P - FG: 100M ohms / 500VDC / 25/ 70% RH Compliance to EN55022 class A, 72/ 245/ CEE, 95/ 54/ CE, E-Mark Compliance to FCC class A None Compliance to EN61000-4-2,3,4,5,6,8,11 RJ11 -RS232 (Option) 466.8*283.5*100mm (L*W*H) 12.9Kg; 1pcs/14Kg/1.98CUFT 1.Efficiency is tested by 2100W, linear load at 13V, 26V, 52V input voltage. 2.Output derating capacity referenced by curve 1. 3.Input derating capacity referenced by curve 2. 4.DC current is tested by 3000W, linear load at 12V, 24V, 48V input voltage. 5.All parameters not specified above are measured at rated load, 25 of ambient temperature and set to factory setting. 6.The tolerance of each voltage value by models is:112/2120.5V;124/2241V;148/2482V 7.THD is tested by 3000W, linear load at 13,26,52V input voltage. File Name:TS-3000-SPEC 2015-05-27 TS-3000 3000W True Sine Wave DC-AC Inverter TS 3000 A :TYPE A OUTLET B :TYPE B OUTLET C :TYPE C OUTLET D :TYPE D OUTLET E :TYPE E OUTLET F :TYPE F OUTLET G :TYPE G TERMINAL 112 A 12:12VDC Bat. Voltage: 24:24VDC 48:48VDC TS:True sine wave inverter Output: O/P Wattage:3000W series 1:110VAC 2:230VAC AC Output Receptacle (optional) Receptacle type (Terminal only) Country TYPE-A TYPE-B TYPE-C TYPE-D TYPE-E TYPE-F TYPE-G USA EUROPE AUSTRALIA U.K JAPAN GFCI ----- E13 Certificate E13 E13 (Expect for 48V input) Derating Curve Mechanical Specification Unit:mm 161.84 122.44 100 LOAD (%) POS 100 31.6 80 60 40 NEG Reverse Polarity Will Damage The Unit. 20 0 10 20 30 40 50 60 70 AMBIENT TEMPERATURE () CURVE 1 46 Air flow direction Air flow direction 100 90.3 LOAD (%) 80 60 40 7 7.5 20 10.5VDC 21VDC 42VDC 11.5VDC 23VDC 46VDC 15VDC 30VDC 60VDC (HORIZONTAL) 286.2 466.8 BATTERY INPUT VOLTAGE (V) CURVE 2 AC Receptacle ON OFF 100 r Ci er Setting 0 Bat Low se e s LOAD 100 On 0 t Pr s Chassis Ground BATTERY INVERTER i t Br e ak cu t o R e Saving Cat.No.(1GG1HS-212) Wire Range(10-4 AWG Str Cu Soldered Wires) Torque (17.7-26.5 in lb) 13 Remote port AC OUTPUT 31.29 Type-A NC NC AC OUTPUT L Note: When the load current is >15A, must use output terminal connection which can be found inside the AC output panel of the inverter. FG N AC Receptacle ON OFF r Ci 34 e s 100 Setting On 0 0 Bat Low se t Pr Chassis Ground t o R e Saving Cat.No.(1GG1HS-212) Wire Range(10-4 AWG Str Cu Soldered Wires) Torque (17.7-26.5 in lb) 273 Remote port 13 283.5 er s LOAD BATTERY INVERTER i t Br e ak 12 100 cu AC OUTPUT 31.29 Type-B File Name:TS-3000-SPEC 2015-05-27 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Mean Well: TS-3000-112A TS-3000-112F TS-3000-124A TS-3000-124F TS-3000-148A TS-3000-148F TS-3000-248B TS3000-224B TS-3000-212B TS3000-248C