Embedded Power for
Business-Critical Continuity
SIL40C2 Series
4.5-13.8 Vin Single
C-Class Non-Isolated
Special Features
•40Acurrentrating
•Inputvoltagerange:4.5-13.8V
•Outputvoltage:0.6-5V
•Industryleadingvalue
•Costoptimizeddesign
•Excellenttransientresponse
•Outputenable
•Outputvoltageadjustability
•Pathwayforfutureupgrades
•Supportssiliconvoltagemigration
•Resultinginreduceddesign-inand
qual time
•RoHSCompliant
40 A Current Rating
Input Voltage: 4.5-13.8 V
No. of Outputs: Single
Output
SXX06ERev.08.01.06Page1of2
Electrical Specifications
Outputvoltage See Note 5 0.6-5V
Outputsetpointaccuracy 0.1%trimresistors ±1.0%
Line regulation Lowlinetohighline ±0.2%
Load regulation Full load to min. load ±0.5%
Min./max.load 0A/40A
Overshoot Atturn-on 0.5%max.
Undershoot Atturn-off 100mVmax.
Rippleandnoise
5Hzto20MHz
See Note 1 25mV
Vin=5V,Vout=2.5V
Transient response SeeNotes1,2 130mVmax.deviation
50µsrecoverytowithin
regulation band
Inputvoltagerange 4.5-13.8 Vdc
Input current Minimum load
RemoteOFF
50mA
5mA
Inputcurrent(max.) See Note 3 25A@lomax.
Start-up time RemoteON/OFF 3 ms
Input
Rev.07.02.08
SIL40C2
1 of 5
Safety
UL,cUL CAN/CSA22.2No.
E139421UL6950FileNo.TBD
VProductService(EN60950)
CertificateNo.TBD
CB report and certificate to
IEC60950
Rev.07.02.08
SIL40C2
2of5
Embedded Power for
Business-Critical Continuity
Thermalperformance
See Note 5
Operatingambient,temperature
Non-operating
0°Cto+70°C
-40°Cto+125°C
Short-circuit Hiccup,non-latching
Overvoltageprotection Hiccup,non-latching
Input capacitance SeeNote6 0µF
Outputcapacitance SeeNote7 0µF
Protection
EnvironmentalSpecifications
Output
Power
(Max.)
Input
Voltage
OVP Output
Voltage
Output
Current
(Min.)
Output
Current
(Max.)
Efciency
(Typical)
Regulation
Line Load
Model
Number (3,5)
200W 4.5-13.8 Vdc N/A 0.6-5Vdc 0A 40A 94% ±0.2% ±0.5% SIL40C2-00SADJ-VJ
200W 4.5-13.8 Vdc N/A 0.6-5Vdc 0A 40A 94% ±0.2% ±0.5% SIL40C2-00SADJ-HJ
200W 4.5-13.8 Vdc N/A 0.6-5Vdc 0A 40A 94% ±0.2% ±0.5% SMT40C2-00SADJJ
Ordering Information
Recommended System Capacitance
Efficiency Vin=5V,Vo=2.5V,lo=20A 94%
Switchingfrequency Fixed 500kHz
Approvalsandstandards
(pending)
EN60950
UL/cUL6950
Material flammability UL94V-0
Weight 17g(0.06oz.)
MTBF 12V@40°C,
100%load
Bellcore332
6,749,409hours
Coplanarity 150µm
General
Rev.07.02.08
SIL40C2
3 of 5
Embedded Power for
Business-Critical Continuity
Notes:
1 Measured as per recommended system capacitance.
2 di/dt=10A/µs,Vin=Nom,Tc=25°C,loadchange=0.75lotofullloandfullloto
0.75.
3 Externalinputfusingisrecommended.
4 Additionalpartnumbersmaybeavailablewithdifferentoutputvoltages.
5 Airflowdependent,100LFMminimumrequired.
6 Nocapacitorsneededforripplecurrentcapability.
7 Nocapacitorsneededforstability.
8 TSERoHS5/6(non-Pb-free)compliantversionsarealsoavailableonspecialrequest,
pleasecontactourlocalsalesrepresentativefordetails.
9 NOTICE:Somemodelsmaynotsupportalloptions.Pleasecontactyour
localrepresentativeorusetheon-linemodelnumbersearchtoolathttp://www.
powerconversion.comtofindasuitablealternative.
10 ToorderaHorizontalMountingoptionwithapinlengthof0.165",pleaseusethe
model#SIL40C2-00SA-HP5J
Product Family
Product Family
SIL = Single In Line
SMT = Surface Mount
Rated Output Current
Rated Output Current
06=6A
15=15A
20=20A
30=30A
40=40A
Output Voltage
Output Voltage
SingleAdjustable
Output
Performance
Performance
C=CostOptimized
Generation
Generation
Blank=StandardPart
2=IncreasedCurrent
Density
Input Voltage
Input Voltage
00=4.5-13.8V
Output Voltage Adjustment of the SIL40C2 Series
PartNumberSystemwithOptions
Theultra-wideoutputvoltagetrimrangeoffersmajoradvantagestouserswhoselectthe
SIL40C2series.Itisnolongernecessarytopurchaseavarietyofmodulesinordertocover
differentoutputvoltages.Theoutputvoltagecanbetrimmedinarangeof0.6-5V.When
theSIL40C2converterleavesthefactory,theoutputhasbeenadjustedtothedefaultvolt-
ageof0.6V.
Mounting Option
Mounting Option
V = Vertical
H=Horizontal
(ApplicabletoSIL
versiononly)
SIL 40 C 2 - 00 SADJ - V J
RoHS Compliance(8)
RoHS Compliance
J=Pb-freeRoHS
6/6Compliant
7,8
10,11
6
9
5
1,2,3
4
SIL40C2
Enable
Vin
GND
Rtrim
(for trim
down)
Cout R
L
O
A
D
Power Good
Vout
+R sense
Cin
Figure 1: Standard Application Drawing
Standard Application Drawing
Rev.07.02.08
SIL40C2
4 of 5
Embedded Power for
Business-Critical Continuity
Mechanical Drawings
Dimensionsininches(mm).Tolerances(unlessotherwisespecied)2Places±0.030(±0.76)3Places±0.010(±0.25)
Vertical Mount
Horizontal Mount
Dimensions in Inches (mm)
Tolerances (unless otherwise specified)
2 Places ±0.030 (±0.76)
3 Places ±0.010 (±0.25)
0.100 (2.54)
1.050 (26.67)
9 PLACES
1.100 (27.94)
1.200 (30.48)
0.050 (1.27) REF
0.140 (3.56) TYP
PIN 1
0.050 (1.27) TYP
0.255 (6.48)
0.110 (2.79)
0.427 (10.85)
0.025 (0.64) ±.001
SQ PINS TYP
0.062 (1.57) REF
0.100 (2.54) TYP
Dimensions in Inches (mm)
Tolerances (unless otherwise specified)
2 Places ±0.030 (±0.76)
3 Places ±0.010 (±0.25)
1.100 (27.94)
1.200 (30.48)
PIN 1
0.255 (6.48)
0.110 (2.79) REF
0.468 (11.89)
0.062 (1.57) REF
.150 (3.81) TYP
0.025 (0.64) ±.001
SQ PINS TYP
13 PLACES
2X 1.050 (26.67)
0.100 (2.54) REF
0.050 (1.27) REF
1.000 (25.40)
2X
0.050 (1.27)
0.100 (2.54) TYP
9 PLACES
Pin Assignments
Pin No. Function
1 Vout
2 Vout
3 Vout
4 Trim
5 Enable
6 PowerGood
7 Ground
8 Ground
9 (+)Sense
10 Vin
11 Vin
12 *Mechsupport
13 *Mechsupport
*HorizontalandSMTversiononly
EmersonNetworkPowerandtheEmerson
NetworkPowerlogoaretrademarksand
servicemarksofEmersonElectricCo.
©2008EmersonElectricCo.
Emerson Network Power.
Thegloballeaderinenabling
business-critical continuity.
EmersonNetworkPower. com
ACPower
Connectivity
DCPower
Embedded Computing
Embedded Power
Monitoring
OutsidePlant
PowerSwitching&Controls
Precision Cooling
Rev.07.02.08
SIL40C2
5 of 5
Embedded Power for
Business-Critical Continuity
SXX06ERev.08.01.06Page1of2
Americas
5810VanAllenWay
Carlsbad,CA92008
USA
Telephone: +1(760)9304600
Facsimile: +1(760)9300698
Europe (UK)
WaterfrontBusinessPark
MerryHill,Dudley
WestMidlands,DY51LX
United Kingdom
Telephone: +44(0)1384842211
Facsimile: +44(0)1384843355
Asia (HK)
14/F,LuPlaza
2WingYipStreet
Kwun Tong, Kowloon
HongKong
Telephone: +85221763333
Facsimile: +85221763888
Forglobalcontact,visit:
www.powerconversion.com
techsupport.embeddedpower
@emerson.com
Whileeveryprecautionhasbeentakentoensure
accuracyandcompletenessinthisliterature,Emerson
NetworkPowerassumesnoresponsibility,anddisclaims
allliabilityfordamagesresultingfromuseofthis
information or for any errors or omissions.
Dimensionsininches(mm).Tolerances(unlessotherwisespecied)2Places±0.030(±0.76)3Places±0.010(±0.25)
Racks&IntegratedCabinets
Services
Surge Protection
Surface Mount
Pin Assignments
Pin No. Function
1 Vout
2 Vout
3 Vout
4 Trim
5 Enable
6 PowerGood
7 Ground
8 Ground
9 (+)Sense
10 Vin
11 Vin
12 *Mechsupport
13 *Mechsupport
*HorizontalandSMTversiononly
Dimensions in Inches (mm)
Tolerances (unless otherwise specified)
2 Places ±0.030 (±0.76)
3 Places ±0.010 (±0.25)
1.100 (27.94)
1.200 (30.48)
PIN 1
0.255 (6.48)
0.110 (2.79) REF
0.442 (11.23)
0.062 (1.57) REF
0.125 (3.18) TYP
2X 1.050 (26.67)
0.100 (2.54) REF
0.050 (1.27) REF
1.000 (25.40)
2X
0.050 (1.27)
0.100 (2.54) TYP
9 PLACES