Terminals
These fork terminals have extra-long PVC
insulation sleeve for protection and stress relief
at wire’s flex point. Brazed seam barrel is
serrated for high pull-out value. Terminal is high
conductivity electrolytic copper, electro-tin
plated. Insulation is color-coded.
Stock thickness same as ring terminal of same
size.
Vinyl Insulated Fork – Insulation Support
Wt./Lbs.
Cat. Pkg. Wire Max. Bolt Per Dimensions
No. Qty. Range Ins. Hole 1000 A B C M
18RA-6F 100 22-16 .150 #6 5 .94 .25 .27 .81
RA1167 1000 22-16 .150 #6 5 .94 .25 .27 .81
18RA-8F 100 22-16 .150 #8 5 .97 .31 .27 .81
RA1147 1000 22-16 .150 #8 5 .97 .31 .27 .81
18RA-10F 100 22-16 .150 #10 5 .97 .31 .27 .81
RA1157 1000 22-16 .150 #10 5 .97 .31 .27 .81
14RB-6F 100 18-14 .170 #6 6 .97 .31 .27 .81
RB647 1000 18-14 .170 #6 6 .97 .31 .27 .81
14RB-6FS 100 18-14 .170 #6 6 .89 .30 .25 .75
14RB-8F 100 18-14 .170 #8 6 .97 .31 .27 .81
RB657 1000 18-14 .170 #8 6 .97 .31 .27 .81
14RB-10F 100 18-14 .170 #10 6 .97 .31 .27 .81
RB1157 1000 18-14 .170 #10 6 .97 .31 .27 .81
14RB-14F 100 18-14 .170 1/4" 6 1.11 .44 .38 .89
RB1717 1000 18-14 .170 1/4" 6 1.11 .44 .38 .89
10RC-6F 50 12-10 .210 #6 7 1.09 .38 .27 .90
RC1337 500 12-10 .210 #6 7 1.09 .38 .27 .90
10RC-8F 50 12-10 .210 #8 7 1.09 .38 .27 .90
RC1147 500 12-10 .210 #8 7 1.09 .38 .27 .90
10RC-10F 50 12-10 .210 #10 7 1.09 .38 .27 .90
RC1157 500 12-10 .210 #10 7 1.09 .38 .27 .90
10RC-14F 50 12-10 .210 1/4" 7 1.15 .50 .37 .90
RC1167 500 12-10 .210 1/4" 7 1.15 .50 .37 .90
U.L. Listed E9809. Installing tools: WT145C, WT2000, WT112M, ERG-2001, ERG-2003, WT2130A(RC)
Most standard bulk catalog numbers can be put on
Mylar Tape for reel fed applications (i.e. 12050 tool
and application dies). See pages 190-191.
Please put the suffix M for Mylar Tape RA2573M.
(Bulk number 1000 and 500 packages.)
Fork terminals allow easy installation since the
mounting screw does not have to be completely
removed. Catalog numbers with the suffix X
indicate an expanded insulation support. This
means a wider wire entry to accommodate heavy
wall insulation.
Stock thickness same as ring terminal of same
size.
Most standard bulk catalog numbers can be put on
Mylar Tape for reel fed applications (i.e. 12050 tool
and application dies). See pages 190-191.
Please put the suffix M for Mylar Tape RA2573M.
(Bulk number 1000 and 500 packages.)
Vinyl Insulation Fork – Expanded Insulation Support
Wt./Lbs.
Cat. Pkg. Wire Max. Bolt Per Dimensions
No. Qty. Range Ins. Hole 1000 A B C M
18RA-6FX 100 22-16 .170 #6 5 .94 .25 .27 .81
RA1167-170 1000 22-16 .170 #6 5 .94 .25 .27 .81
18RA-8FX 100 22-16 .170 #8 5 .97 .31 .27 .81
RA1147-170 1000 22-16 .170 #8 5 .97 .31 .27 .81
18RA-10FX 100 22-16 .170 #10 5 .97 .31 .27 .81
RA1157-170 1000 22-16 .170 #10 5 .97 .31 .27 .81
14RB-6FX 100 18-14 .200 #6 6 .97 .31 .27 .81
RB647-200 1000 18-14 .200 #6 6 .97 .31 .27 .81
14RB-8FX 100 18-14 .200 #8 6 .97 .31 .27 .81
RB657-200 1000 18-14 .200 #8 6 .97 .31 .27 .81
14RB-10FX 100 18-14 .200 #10 6 .97 .31 .27 .81
RB1157-200 1000 18-14 .200 #10 6 .97 .31 .27 .81
10RC-8FX 50 12-10 .250 #8 7 1.11 .38 .27 .90
RC1147-250 500 12-10 .250 #8 7 1.11 .38 .27 .90
10RC-10FX 50 12-10 .250 #10 7 1.11 .38 .27 .90
RC1157-250 500 12-10 .250 #10 7 1.11 .38 .27 .90
10RC-14FX 50 12-10 .250 1/4" 7 1.17 .50 .37 .90
U.L. Listed E9809. Installing tools: WT145C, WT2000, WT112M, ERG2001, ERG2003 WT2130A(RC)
149