International Safety Standard Approvals
VDE0805/EN60950/IEC950/IEC1010 File No. 10401-3336-1076
Licence No. 70567, 1076 and 90354
UL1950 File No. E136005
CSA C22.2 No. 950 File No. LR41062C
Certificate No. PS/605108
NAL40 and NAN40 SERIES
Single, dual and triple output
[ 2 YEAR WARRANTY ]
• 5.0 x 3.0 x 1.2 inch package (1U applications)
• Ideal for high volume designs
• Industry standard package
• Overvoltage and short circuit protection
• 40W with free air convection
• NAN40: EN55022, EN55011 conducted emissions level B
• NAL40: EN55022, EN55011 conducted emissions level A
The NAL40 and NAN40 series are 40W universal input AC/DC power supplies
on a 5 x 3 inch card with a maximum component height of 1.2 inch for use in
1U applications. These series are available with a wide range of models in the
industry standard 5 x 3 inch footprint at low cost making the series ideal for new
and existing high volume communication and industrial applications. The
difference between the NAL40 and NAN40 is their conducted emissions
performance - the NAN40 meets EN55022 level B while the NAL40 meets level
A. The NAL40 and NAN40 provide 40W of output power with free air
convection cooling with a peak output of 50W for a maximum duration of 60
seconds. The NAL40 and NAN40 series are designed for use in high volume
low power data networking, computer and telecom applications such as hubs,
routers, POS terminals, cable modems and PABX's. This list is not exclusive as
the generic feature set of both series with industry standard output
configurations provide a solution for most high volume applications including
many industrial applications.
SPECIFICATION
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
PAGE 1
EMC CHARACTERISTICS
Conducted emissions NAL: EN55022, FCC part 15 level A
Conducted emissions NAN: EN55022, FCC part 15 level B
Radiated emissions EN55022, FCC part 15 level A
ESD air EN61000-4-2, level 3 Perf. criteria 2
ESD contact EN61000-4-2, level 4 Perf. criteria 2
Surge EN61000-4-5, level 3 Perf. criteria 2
Fast transients EN61000-4-4, level 3 Perf. criteria 2
Radiated immunity EN61000-4-3, level 3 Perf. criteria 2
Conducted immunity EN61000-4-6, level 3 Perf. criteria 2
GENERAL SPECIFICATIONS
Hold-up time 110VAC 10ms @ 40W
230VAC 60ms @ 40W
Efficiency 68% min. @ 40W
Isolation voltage Input/output 3000VAC
Input/chassis 1500VAC
Switching frequency Variable
Approvals and VDE0805, EN60950, IEC950
standards BABT, IEC1010, UL1950
(See Note 9) CSA C22.2 No. 950
Weight 200g (7.06oz)
MTBF MIL-HDBK-217F 150,000 Hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance Operating 0°C to +70°C
Non-operating -40°C to +85°C
0°C to 50°C ambient, 40W
convection cooled
50°C to 70°C, Derate linearly
ambient conv. cooled to half load
Peak (0°C to 50°C) max. 60s 50W
Relative humidity Non-condensing 5% to 95% RH
Altitude Operating 10,000 feet max.
Non operating 30,000 feet max.
Vibration Three orthogonal axes, 2.4G rms
random vibration, 10 5Hz to 500Hz
minute test for each axis
OUTPUT SPECIFICATIONS
Line regulation Main output ±0.5%
Auxiliary outputs ±1.0%
Total regulation Main output ±3.0%
Auxiliary outputs ±5.0%
Overshoot/undershoot At turn-on <10%
Transient response +5.1V ±150mV max. dev.,
(1.5A to 3A step) 500µs recovery
Temperature coefficient ±0.02%/°C
Overvoltage protection +5.1V output 6.25V ±0.75Vout
Output power limit Primary power 50W Pout, min.
limited 110W Pin, max.
Short circuit protection Multiple output 30 seconds
Single 12V, 15V, Continuous
24V and 48V automatic recovery
Output voltage trim NAN40-7662 only ±5% (See Note 10)
INPUT SPECIFICATIONS
Input voltage range Universal input 90 to 264VAC
120 to 370VDC
Input frequency range 47Hz to 440Hz
Input surge current 110VAC, cold start 15A
230VAC, cold start 32A
Safety ground 110VAC, 60Hz 0.2mA
leakage current 230VAC, 50Hz 0.4mA
Data Sheet © Artesyn Technologies
®
2005