PRELIMINARY
Q3 2003
Active PFC - Meets EN61000-3-2, -3
200 W with Convection Cooling
Meets 1U, Low Profile Requirements
Zero Voltage Switching Technology
Remote On/Off / Remote Sense
Optional Current Share
Input
AC Input Voltage 85-264 VAC
Input Frequency 47-63 Hz
DC Input Voltage 170-370 VDC
Inrush Current 30 A max at 115 VAC
60 A max at 230 VAC
Input Current 4 A max at 115 VAC
2 A max at 230 VAC
Remote On/Off Off = Logic High, or +5 V
On = Logic Low, or short circuit,
or open
Power Factor 0.98 for 115 VAC, 0.90 for 230 VAC
Output
Output Voltage 5-48 VDC
Output Voltage On output #1 only ±10%
Adjustment
Output Power 250 Watts
Minimum Load 2 A required on V1
Line Regulation ±0.5% from low line to high line
Load Regulation ±1% for V1 & V2, ±5% for V3 & V4
Cross Regulation 15% maximum
Set Point Accuracy ±1%
Ripple & Noise ±1% peak to peak maximum
Transient Response 4% max deviation, 500 µs recovery
time for a 25% load change
Temperature ±0.05%/°C
Coefficient
Hold Up Time 20 ms minimum at low line
Remote Sense V1 & V2 compensates for up to
0.5 V drop
Overvoltage 115% to 140%, recycle input to reset
Protection
Overcurrent 120% - 150% with auto recovery
Protection
Overtemperature Standard
Protection
Current Share Single wire current sharing on
V1 & V2 (optional)
Fan Output 12 V at 100 mA
General
Efficiency (typical) >80%, nominal line full load
Power Density 4.9 W/in3
MTBF 255,000 hrs min to MIL-HDBK-217F
Withstand Voltage 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
Size 8.0” x 4.2” x 1.5”
Weight 770 grams approx
Signals AC OK = Logic Hi, DC OK = Logic Hi
Environmental
Operating 0 °C to +70 °C See Derating Chart
Temperature Full power to 50 °C
Cooling 250 W with 18 CFM airflow
200 W Convection Cooling
Storage Temperature -20 °C to +85 °C
Safety and EMC
Safety Approvals UL60950, CSA C22.2 No 234,
EN60950, CE Mark LVD
EMI/EMC EN61000-3-2, -3,
EN55022 Class B and FCC 20780
Level B conducted
Immunity & Surge EN50082-2 (EN61000-4-2,-3, -4, -5)
Performance criteria A
250 Watts
JPS250 Quad Output Series
AC/DC U-Channel
Specification
Intelligent Design Quality Product
XPiQ inc.
PH: 508 429.9883
FAX: 800 226.2100
Email: sales@xpiq.com
Holliston, MA 01746 USA
www.XPiQ.com
29
* Preliminary datasheet - see website for current specs
JPS250Q.qxd 25/6/03 12:26 pm Page 1
Mechanical Details
Derating Graph - 250 Watts
OUTPUT VOLTAGE & CURRENT RATINGS JPS250Q
Output 1 Output 2 Output 3 Output 4 Model
Output Conv. Max Output Conv. Max Output Conv. Max Output Conv. Max Number
V1 Cooled 18 CFM V2 Cooled 18 CFM V3 Cooled 18 CFM V4 Cooled 18 CFM
3.3 V 16.0 A 20.0 A 5.0 V 12.0 A 20.0 A 12.0 V 5.0 A 6.0 A -12.0 V 1.0 A 2.0 A JPS250PQ46
5.0 V 17.5 A 30.0 A 12.0 V 7.0 A 8.0 A -12.0 V 2.0 A 3.0 A -5.0 V 1.0 A 2.0 A JPS250PQ41
5.0 V 20.0 A 25.0 A 12.0 V 4.0 A 6.0 A 24.0 V 2.0 A 3.0 A -12.0 V 1.0 A 2.0 A JPS250PQ47*
5.0 V 20.0 A 25.0 A 15.0 V 3.0 A 5.0 A 24.0 V 2.0 A 3.0 A -15.0 V 1.0 A 2.0 A JPS250PQ48*
Notes
1. Maximum power with 18 CFM forced air, is 250 Watts, or 200 Watts with convection cooling.
2. For current share option add suffix “C” to part number.
3. Current share models are built to order.
4. All models require 2 A minimum load on V1. On V2, JPS250PQ46 requires 1 A and JPS250PQ41 requires 0.5 A.
NOTES:
1. Dimensions shown in inches (mm).
2. Tolerance is ±0.8mm max.
3. TB2 signal connector is molex
70246-10 or equivalent.
4. TB5 is for fan, 12V/100 mA with
Molex 5045-02A or equivalent.
5. TB1 (AC input) and TB3 (DC output) are
terminal blocks.
Pin Chart
TB2 1 2 3 4 5 6 7 8 9 10
JPS250PQ46 +Sense 3.3 V -Sense 5V Share 3.3 V DC OK +Sense 5 V -Sense 3.3 V Share 5.0 V Enable AC OK GND
JPS250PQ41 +Sense 5 V -Sense 5V Share 12.0 V DC OK +Sense 12 V -Sense 5.0 V -Sense 12.0 V Enable AC OK GND
* Preliminary models JPS250PQ47 & JPS250PQ48 will be released in Q3 2003 - see website for current specs.
TB3 1 2 3 4 5 6 7 8 9 10
JPS250PQ46 3.3 V 3.3 V GND GND GND GND 12.0 V -12.0 V 5.0 V 5.0 V
JPS250PQ41 5.0 V 5.0 V GND GND GND -5.0 V -12.0 V 12.0 V
* Preliminary models JPS250PQ47 & JPS250PQ48 will be released in Q3 2003 - see website for current specs.
Application Notes
1. To turn off the output, apply 5 V to the remote ON/OFF.
2. AC OK is a TTL signal which goes LOW when input
falls below 60 VAC at rated load.
3. DC OK is a TTL signal which goes LOW when PSU is
in an overcurrent condition, overvoltage condition,
disabled or when output falls out of regulation.
4. For AC OK and DC OK signals, source current is 1 mA,
sink current is 6 mA.
PH: 508 429.9883
FAX: 800 226.2100
Email: sales@xpiq.com
Holliston, MA 01746 USA
www.XPiQ.com
* Preliminary datasheet - see website for current specs and application notes.