236/237/238
CLASS
PAGE
WEBSITE: www.struthers-dunn.com EMAIL:info@struthers-dunn.com FAX # 1-843-662-8862 PHONE # 1-843-664-3303
236 A B X P 020 120A
Typical P art Number
C ode 012**- 12 S ec ond timing not available on 237 & 238 models .
(F *
Models) - timing code does not apply. S pecify single delay time requirement.
E xample of typical fixed time delay relay part number- 236XB XP -3.5F -120A
(ON DE LAY , DP DT, 3.5 S E C F IXE D, 120 VAC INP UT P O W E R ).
NOT E S :
1. 236,237,238 - E xternal res istor (to program time delay) or jumper (for
built-in timing) must be connected to terminals 8 & 9.
2. 237 models require an external control s witch between terminals 5 & 6.
3. 238 s witches contacts when input power is applied and s tarts timing.
C ontacts switch back to original position at end of timing cycle. P ower must
be removed to reset timer. If input power is interupted during the timing
cycle, timing ends immediately and the relay res ets.
4. Dielectric withs tanding voltage tes ting of the C ontrol circuit may damage
the solid s tate components.
G E NE R AL S P E C IF IC AT IONS (@ 25 C )
The S eries 236, 237 and 238 T ime Delay R elays
consist of a standard 219 industrial relay and a s olid s tate timing
module to provide delayed transfer of relay contacts after
application of power or activation of control switch. The
relay and timing module are enclosed in a flame res is tant
polycarbonate cover.
UL R ecognized
F ile No. E 13224
S E R IE S 236 ON DE L A Y , 237 OF F DE L AY & 238 B ATC H C ONTR OL
INT E R VAL (S E E NOTE 3)
AC OR DC INP UT
DP DT OR DP DT WIT H 1 N.O. C ONTAC T ON S E R IE S 236 & 238
12 P IN P L UG -IN W IT H L OC K ING C L IP
TIMING : S C R E WDR IV E R A DJ US TAB L E OR F IXE D
AC : 24 to 240, DC : 12 to 125
AC - 85% of Nominal
DC - 80% of Nominal
110% of nominal voltage
S ilver C admium Oxide.
10 Amps @ 120 VAC res.
10 Amps @ 28 VDC
DC : ± 3%: @ 20ûC . AC : ± 3% +16 mS
@ 20 C .
Adjustable: ± 10% Within temperature
& voltage range. F ixed: ± 10% @ 25û C
100 mS (for timing cycle up to 60 sec.
150 mS for timing cycle 60 to 300 s ec.
500 V rms acros s open contacts,
1500 V rms between output contacts
and ground (Locking clip). (S ee note 4).
1000 Megohms min. @ 500 VDC .
5 mS , 0 to 2000 V 20 uS ec peak
No false contacting if power is
interupted during timing.
DC operated are polarity protected. but
will not operate if polarity is revers ed.
- 10 C to +70 C
10 Million Operations no load
100,000 Operations @ R ated Load.
C lear P olycarbonate
8.6 oz approx. (244 g)
S eries
236 - ON DE LAY
237 - OF F DE LAY (Note 2)
238 -
INT E R V AL (Note 3)
C ontac t Arrangements
AB X (DP DT & 1 N.O. C ontact) 236 &
238 only).
XB X (DP DT)
Mounting Options
P (P lug-in)
Timing R anges
0.2 - 12 S ec - C ode 012**
0.2 - 20 S ec - C ode 020
2.0 - 200 S ec - C ode 200
Adjus tment Options
Adjustment S crew) - No C ode
F ixed Delay - S pecify F ixed T ime & C ode F *
Operating Voltage
AC ; 24, 48, 120, 240 (A dd " A " )
DC ; 12, 24, 48, 115-125 (Add " D" )
INP UT
Nominal V oltage:
Minimum Oper. V oltage:
Max. allowed voltage:
C ONT AC T S
C ontact Material:
R ating:
OP E R A T IONA L C HA R AC TE R IS TIC S
R epeatability:
Accuracy:
Min. waiting time before starting
next cycle (R es et T ime):
INS UL AT ION C HA R AC TE R IS T IC S
Dielectric S trength:
Insulation R esis tance:
T rans ient P rotection:
F alse C ontacting:
Inverse polarity protection:
E NVIR ONME NTAL C A P AB IL ITIE S
Ambient T emperature R ating:
L IF E E XP E C TA NC Y
Mechanical:
E lectrical:
MIS C E L L A NE O US
Enclosure:
Weight:
STRUTHERS-DUNN
12 PIN, 10 AMP, TIME DELAY RELAY
STRUTHERS-DUNN
0
0
0
0
NUCLEAR VERSIONS
AVAILABLE