INCH-POUND The documentation and process conversion measures necessary to comply with this document shall be completed by 16 January 2015. MIL-PRF-19500/291V 16 October 2014 SUPERSEDING MIL-PRF-19500/291U 16 February 2013 PERFORMANCE SPECIFICATION SHEET SEMICONDUCTOR DEVICE, TRANSISTOR, PNP, SILICON, SWITCHING, TYPES 2N2906A, 2N2906AL, 2N2907A, 2N2907AL, 2N2906AUA, 2N2907AUA, 2N2906AUB, 2N2906AUBC, 2N2907AUB, 2N2907AUBC, 2N2906AUBN, 2N2906AUBCN, 2N2907AUBN, AND 2N2907AUBCN, JAN, JANTX, JANTXV, JANTXVM, JANTXVD, JANTXVP, JANTXVL, JANTXVR, JANTXVF, JANTXVG, JANTXVH, JANS, JANSM, JANSD, JANSP, JANSL, JANSR, JANSF, JANSG, JANSH JANHC, JANKC, JANKCM, JANKCD, JANKCP, JANKCL, JANKCR, JANKCF, JANKCG, AND JANKCH This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-PRF-19500. 1. SCOPE * 1.1 Scope. This specification covers the performance requirements for PNP, silicon, switching transistors. Five levels of product assurance are provided for each encapsulated device type as specified in MIL-PRF-19500 and two levels of product assurance are provided for each unencapsulated device type. Provisions for radiation hardness assurance (RHA) to eight radiation levels is provided for JANTXV, JANS, JANHC, and JANKC product assurance levels. Radiation hardness assurance (RHA) level designators "M", "D", "P", "L" "R", "F', "G", and "H" are appended to the device prefix to identify devices which have passed RHA requirements. 1.2 Physical dimensions. See figure 1 (similar to a TO-18), figure 2, (surface mount case outlines UA, figure 3 UB (metal lid, as shield, connected to fourth pad), UBC (ceramic lid, braze-ring connected to fourth pad), UBN (3-pin, isolated metal lid), and UBCN (3-pin, isolated ceramic lid) and figures 4, and 5 (JANHC and JANKC). * 1.3 Maximum ratings. Unless otherwise specified TA = +25C. Types All devices IC VCBO VEBO VCEO TJ and TSTG mA dc V dc V dc V dc C -600 -60 -5 -60 -65 to +200 Comments, suggestions, or questions on this document should be addressed to DLA Land and Maritime, ATTN: VAC, P.O. Box 3990, Columbus, OH 43218-3990, or emailed to Semiconductor@dla.mil. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at https://assist.dla.mil . AMSC N/A FSC 5961 Source: http://assist.dla.mil -- Downloaded: 2021-04-29T16:52Z Check the source to verify that this is the current version before use. MIL-PRF-19500/291V 1.3 Maximum ratings. Unless otherwise specified TA = +25C. - Continued. Types 2N2906A, L, 2N2907A, L 2N2906AUA, 2N2907AUA 2N2906AUB, and UBN 2N2907AUB and UBN 2N2906AUBC and UBCN 2N2907AUBC and UBCN (1) (2) (3) (4) RJA (2) (3) RJC (2) (3) RJSP(IS) (2) (3) RJSP(AM) (2) (3) C/W C/W C/W C/W N/A N/A 1.5 1.5 N/A 325 325 (4) 325 (4) 325 (4) 325 150 150 N/A N/A N/A N/A N/A 110 110 90 N/A N/A 40 40 N/A 1.0 N/A (4) 325 N/A 90 N/A N/A 1.0 N/A (4) 325 N/A 90 N/A N/A 1.0 N/A (4) 325 N/A 90 N/A PT PT PT PT TA = +25C (1) (2) W TC = +25C (1) (2) W TSP(IS) = +25C (1) (2) W TSP(AM) = +25C (1) (2) W 0.5 0.5 (4) 0.5 (4) 0.5 (4)0.5 1.0 1.0 N/A N/A N/A N/A N/A 1.0 1.0 1.0 (4) 0.5 N/A (4) 0.5 (4) 0.5 For derating, see figures 6, 7, 8, 9, and 10. See 3.3 for abbreviations. For thermal curves, see figures 11, 12, 13, 14, and 15. For non-thermal conductive PCB or unknown PCB surface mount conditions in free air, substitute figures 6 and 11 for the UA, UB,, UBC, UBN, and UBCN package and use RJA. * 1.4 Primary electrical characteristics. Unless otherwise specified TA = +25C. hFE1 IC = -0.1 mA dc hFE2 IC = -1.0 mA dc hFE at VCE = -10 V dc hFE3 IC = -10 mA dc hFE4 (1) IC = -150 mA dc hFE5 (1) IC = -500 mA dc 2N2906A, 2N2907A, 2N2906A 2N2907A 2N2906A 2N2907A 2N2906A 2N2907A 2N2906A 2N2907A L, L, UA,UB, L, UA,UB, , L, UA,UB, L, UA,UB, L, UA,UB, L, UA,UB, L, UA,UB, L, UA,UB, L, UA,UB, UA,UB, UBC, UBN, UBC, UBN, UBC, UBN, UBC, UBN, UBC, UBN, UBC, UBN, UBC, UBN, UBC, UBN, UBC, UBN, UBC, UBN, UBCN UBCN UBCN UBCN UBCN UBCN UBCN UBCN UBCN UBCN Min 40 75 40 100 40 100 40 100 40 50 Max 175 450 120 300 Types 2N2906A, 2N2907A, L, UA, UB, UBC, UBN, UBCN Limit |hfe| f = 100 MHz VCE = -20 V dc, IC = -20 mA dc Min Max Cobo 100 kHz f 1 MHz VCB = -10 V dc, IE = 0 pF Switching (saturated) ton toff See figure 16 See figure 17 ns ns 45 300 2.0 8 Types Limits 2N2906A, 2N2907A, L, UA, UB, UBC UBN, UBCN Min Max VCE(sat)1 (1) IC = -150 mA dc IB = -15 mA dc VCE(sat)2 (1) IC = -500 mA dc IB = -50 mA dc V dc V dc -0.4 -1.6 VBE(sat)1 (1) IC = -150 mA dc IB = -15 mA dc VBE(sat)2 (1) IC = -500 mA dc IB = -50 mA dc V dc -0.6 -1.3 (1) Pulsed see 4.5.1. 2 Source: http://assist.dla.mil -- Downloaded: 2021-04-29T16:52Z Check the source to verify that this is the current version before use. V dc -2.6 MIL-PRF-19500/291V Symbol Dimensions Inches Min Max Notes Millimeters Min Max CD .178 .195 4.52 4.95 CH .170 .210 4.32 5.33 HD .209 .230 5.31 5.84 LC .100 TP 2.54 TP 6 LD .016 .021 0.41 0.53 7,8 LL .500 .750 12.70 19.05 7,8,13 LU .016 .019 0.41 0.48 7,8 1.27 7,8 L1 .050 L2 .250 6.35 P .100 2.54 Q .030 7,8 0.76 5 TL .028 .048 0.71 1.22 3,4 TW .036 .046 0.91 1.17 3 0.25 10 r .010 45 TP 45 TP 6 NOTES: 1. Dimension are in inches. 2. Millimeters are given for general information only. 3. Beyond r (radius) maximum, TW shall be held for a minimum length of .011 inch (0.28 mm). 4. Dimension TL measured from maximum HD. 5. Body contour optional within zone defined by HD, CD, and Q. 6. Leads at gauge plane .054 +.001 -.000 inch (1.37 +0.03 -0.00 mm) below seating plane shall be within .007 inch (0.18 mm) radius of true position (TP) at maximum material condition (MMC) relative to tab at MMC. 7. Dimension LU applies between L1 and L2. Dimension LD applies between L2 and LL minimum. Diameter is uncontrolled in L1 and beyond LL minimum. 8. All three leads. 9. The collector shall be internally connected to the case. 10. Dimension r (radius) applies to both inside corners of tab. 11. In accordance with ASME Y14.5M, diameters are equivalent to x symbology. 12. Lead 1 = emitter, lead 2 = base, lead 3 = collector. 13. For L suffix devices, dimension LL = 1.5 inches (38.10 mm) min. and 1.75 inches (44.45 mm) max. FIGURE 1. Physical dimensions (similar to TO-18). 3 Source: http://assist.dla.mil -- Downloaded: 2021-04-29T16:52Z Check the source to verify that this is the current version before use. MIL-PRF-19500/291V UA Symbol BL BL2 BW BW2 CH L3 LH LL1 LL2 LS LW LW2 Pin no. Transistor Dimensions Inches Millimeters Min Max Min Max .215 .225 5.46 5.71 .225 5.71 .145 .155 3.68 3.93 .155 3.93 .061 .075 1.55 1.90 .003 0.08 .029 .042 0.74 1.07 .032 .048 0.81 1.22 .072 .088 1.83 2.23 .045 .055 1.14 1.39 .022 .028 0.56 0.71 .006 .022 0.15 0.56 1 Collector 2 Emitter 3 Base Note 3 5 5 4 N/C NOTES: 1. Dimensions are in inches. 2. Millimeters are given for general information only. 3. Dimension "CH" controls the overall package thickness. When a window lid is used, dimension "CH" must increase by a minimum of .010 inch (0.254 mm) and a maximum of .040 inch (1.020 mm). 4. The corner shape (square, notch, radius) may vary at the manufacturer's option, from that shown on the drawing. * 5. Dimensions "LW2" minimum and "L3" minimum and the appropriate castellation length define an unobstructed three-dimensional space traversing all of the ceramic layers in which a castellation was designed. (Castellations are required on bottom two layers, optional on top ceramic layer.) Dimension "LW2" maximum define the maximum width and depth of the castellation at any point on its surface. Measurement of these dimensions may be made prior to solder dipping. 6. The coplanarity deviation of all terminal contact points, as defined by the device seating plane, shall not exceed .006 inch (0.15 mm) for solder dipped leadless chip carriers. 7. In accordance with ASME Y14.5M, diameters are equivalent to x symbology. * FIGURE 2. Physical dimensions, surface mount (UA version). 4 Source: http://assist.dla.mil -- Downloaded: 2021-04-29T16:52Z Check the source to verify that this is the current version before use. MIL-PRF-19500/291V FIGURE 3. Physical dimensions, surface mount (UB, UBN, UBC, and UBCN versions). 5 Source: http://assist.dla.mil -- Downloaded: 2021-04-29T16:52Z Check the source to verify that this is the current version before use. MIL-PRF-19500/291V Symbol BL BW BH BH BH BH CL CW LL1 LL2 LS1 LS2 LW r r1 r2 Inches Min .115 .095 .046 .046 .055 .055 .022 .014 .035 .071 .016 Dimensions Millimeters Max Min Max .128 2.92 3.25 .108 2.41 2.74 .056 1.17 1.42 .056 1.17 1.42 .069 1.40 1.75 .069 1.40 1.75 .128 3.25 .108 2.74 .038 0.56 0.97 .035 0.356 0.89 .040 0.89 1.02 .079 1.80 2.01 .024 0.41 0.61 .008 0.20 .012 0.30 .022 0.56 Note UB only, 4 UBN only, 5 UBC only, 6 UBCN only, 7 3 PLS 3 PLS 6 8 UB & UBC only, 8 NOTES: 1. Dimensions are in inches. 2. Millimeters are given for general information only. 3. Hatched areas on package denote metallized areas. 4. UB only: Pad 1 = Base, Pad 2 = Emitter, Pad 3 = Collector, Pad 4 = Shielding connected to the metal lid. 5. UBN only: Pad 1 = Base, Pad 2 = Emitter, Pad 3 = Collector, Isolated lid with three pads only. 6. UBC (ceramic lid) only: Pad 1 = Base, Pad 2 = Emitter, Pad 3 = Collector, Pad 4 = Shielding connected to the lid. 7. UBCN (ceramic lid) only: Pad 1 = Base, Pad 2 = Emitter, Pad 3 = Collector, Isolated lid with 3 pads only. 8. For design reference only. 9. In accordance with ASME Y14.5M, diameters are equivalent to x symbology. FIGURE 3. Physical dimensions, surface mount (UB, UBN, UBC, and UBCN versions) - Continued. 6 Source: http://assist.dla.mil -- Downloaded: 2021-04-29T16:52Z Check the source to verify that this is the current version before use. MIL-PRF-19500/291V 1. 2. 3. 4. Chip size: Chip thickness: Top metal: Back metal: 5. Glassivation: 6. Backside: 7. Bonding pad: .023 x .023 inch .002 inch (0.584 mm x 0.584 mm 0.0508 mm). .010 .0015 inch (0.254 mm 0.038 mm). Aluminum 15,000 A minimum, 18,000 A nominal. A. Al/Ti/Ni/Ag 15kA/5kA/10kA/10kA. B. Gold 2.5 kA minimum, 3.0 kA nominal. C. Eutectic Die Mount - No metal. SI3N4 2kA minimum, 2.2k nominal. Collector. B = .0042 x .0042 inch (0.107 mm x 0.107 mm). E = .0042 x .0042 inch (0.107 mm x 0.107 mm). FIGURE 4. JANHC and JANKC (B-version) die dimensions. 7 Source: http://assist.dla.mil -- Downloaded: 2021-04-29T16:52Z Check the source to verify that this is the current version before use. MIL-PRF-19500/291V E B 1. 2. 3. 4. 5. 6. 7. 8. Die size: Die thickness: Base pad: Emitter pad: Back metal Top metal: Back side: Glassivation: .020 x .020 inch square (0.508 mm x 0.508 mm). .008 .0016 inch (0.203 mm 0.041 mm). .004 x .004 inch (0.101 mm x 0.101 mm). .004 x .004 inch (0.101 mm x 0.101 mm). Gold, 6,500 1,950 A. Aluminum, 20,000 2,000 A. Collector. SiO2, 7,500 1,500 A. FIGURE 5. JANHC and JANKC (D-version) die dimensions. 8 Source: http://assist.dla.mil -- Downloaded: 2021-04-29T16:52Z Check the source to verify that this is the current version before use. MIL-PRF-19500/291V 2. APPLICABLE DOCUMENTS * 2.1 General. The documents listed in this section are specified in sections 3 and 4 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements of documents cited in sections 3 and 4 of this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-PRF-19500 - Semiconductor Devices, General Specification for. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-750 - Test Methods for Semiconductor Devices. * (Copies of these documents are available online at https://assist.dla.mil/quicksearch). 2.3 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 General. The individual item requirements shall be as specified in MIL-PRF-19500 and as modified herein. 3.2 Qualification. Devices furnished under this specification shall be products that are manufactured by a manufacturer authorized by the qualifying activity for listing on the applicable qualified manufacturers list before contract award (see 4.2 and 6.3). 3.3 Abbreviations, symbols, and definitions. Abbreviations, symbols, and definitions used herein shall be as specified in MIL-PRF-19500 and as follows. PCB RJA RJC RJSP(AM) RJSP(IS) TSP(AM) TSP(IS) UA, UB, UBC UBN, UBCN Printed circuit board Thermal resistance junction to ambient. Thermal resistance junction to case. Thermal resistance junction to solder pads (adhesive mount to PCB). Thermal resistance junction to solder pads (infinite sink mount to PCB). Temperature of solder pads (adhesive mount to PCB). Temperature of solder pads (infinite sink mount to PCB). Surface mount case outlines (see figure 2). Surface mount case outlines (see figure 3). Surface mount case outlines (see figure 3). 3.4 Interface and physical dimensions. The interface and physical dimensions shall be as specified in MIL-PRF-19500, and on figures 1, 2, 3, 4, and 5 herein. Epoxy die attach may be used when a moisture monitor plan has been submitted and approved by the qualifying activity. 9 Source: http://assist.dla.mil -- Downloaded: 2021-04-29T16:52Z Check the source to verify that this is the current version before use. MIL-PRF-19500/291V 3.4.1 Lead finish. Lead finish shall be solderable as defined in MIL-PRF-19500. Where a choice of lead finish is desired, it shall be specified in the acquisition document (see 6.2). 3.5 Radiation hardness assurance (RHA). Radiation hardness assurance requirements, PIN designators, and test levels shall be as defined in MIL-PRF-19500. 3.6 Electrical performance characteristics. Unless otherwise specified herein, the electrical performance characteristics are as specified in 1.3, 1.4, and table I. 3.7 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table I herein. 3.8 Marking. Marking shall be in accordance with MIL-PRF-19500, except for the UB, UBC, UBN, and UBCN suffix packages. Marking on the UB, UBC, UBN, and UBCN packages shall consist of an abbreviated part number, the date code, and the manufacturer's symbol or logo. The prefixes JAN, JANTX, JANTXV, and JANS can be abbreviated as J, JX, JV, and JS respectively. The "2N" prefix and the "AUB" and "AUBC" suffix can also be omitted. The radiation hardened designator M, D, P, L, R, F, G, or H shall immediately precede (or replace) the device "2N" identifier (depending upon degree of abbreviation required). * 3.9 Workmanship. Semiconductor devices Transistor, PNP, Silicon, Switching shall be processed in such a manner as to be uniform in quality and shall be free from other defects that will affect life, serviceability, or appearance. 4. VERIFICATION 4.1 Classification of inspections. The inspection requirements specified herein are classified as follows: a. Qualification inspection (see 4.2). b. Screening (see 4.3). c. Conformance inspection (see 4.4 and tables I, II, and III). 4.2 Qualification inspection. Qualification inspection shall be in accordance with MIL-PRF-19500, and as specified herein. 4.2.1 JANHC and JANKC qualification. JANHC and JANKC qualification inspection shall be in accordance with MIL-PRF-19500. 4.2.2 Group E qualification. Group E inspection shall be performed for qualification or re-qualification only. In case qualification was awarded to a prior revision of the specification sheet that did not request the performance of table III tests, the tests specified in table III herein that were not performed in the prior revision shall be performed on the first inspection lot of this revision to maintain qualification. 10 Source: http://assist.dla.mil -- Downloaded: 2021-04-29T16:52Z Check the source to verify that this is the current version before use. MIL-PRF-19500/291V 4.3 Screening (JANTX, JANTXV, and JANS levels only). Screening shall be in accordance with table E-IV of MILPRF-19500, and as specified herein. The following measurements shall be made in accordance with table I herein. Devices that exceed the limits of table I herein shall not be acceptable. Screen (see table E-IV of MIL-PRF-19500) Measurement JANS level JANTXV and JANTX level 1b Required Required (JANTXV only) 2 Optional Optional Required Not applicable Required method 3131 of MIL-STD-750 Required Not applicable Required method 3131 of MIL-STD-750 4 Required Optional 5 Required Not required 6 Not applicable Not applicable 8 Required Not required 9 ICBO2, hFE4, read and record Not applicable 10 24 hours minimum 24 hours minimum 11 ICBO2; hFE4; ICBO2 = 100 percent of initial value or 5 nA dc, whichever is greater. hFE4 = 15 percent ICBO2, hFE4 12 See 4.3.2 See 4.3.2 Subgroups 2 and 3 of table I herein; ICBO2 = 100 percent of initial value or 5 nA dc, whichever is greater; hFE4 = 15 percent Subgroup 2 of table I herein; ICBO2 = 100 percent of initial value or 5 nA dc, whichever is greater; hFE4 = 15 percent 15 Required Not required 16 Required Not required 3a 3b (1) 3c (2) 13 (1) Shall be performed anytime after temperature cycling, screen 3a; TX and TXV do not need to be repeated in screening requirements. (2) PDA = 5 percent for screen 13, applies to ICBO2, hFE4, ICBO2, and hFE4. Thermal impedance (ZJX) is not required in screen 13. 11 Source: http://assist.dla.mil -- Downloaded: 2021-04-29T16:52Z Check the source to verify that this is the current version before use. MIL-PRF-19500/291V 4.3.1 Screening (JANHC and JANKC). Screening of JANHC and JANKC die shall be in accordance with MIL-PRF-19500, "Discrete Semiconductor Die/Chip Lot Acceptance". Burn-in duration for the JANKC level follows JANS requirements; the JANHC follows JANTX requirements. * 4.3.2 Power burn-in conditions. Power burn-in conditions are as follows: VCB = -10 to -30 V dc. Power shall be applied to achieve TJ = +135C minimum using a minimum PD = 75 percent of PT maximum, TA ambient rated as defined in 1.3. With approval of the qualifying activity and preparing activity, alternate burn-in criteria (hours, bias conditions, TJ, and mounting conditions) for JANTX and JANTXV quality levels may be used. A justification demonstrating equivalence is required. In addition, the manufacturing site's burn-in data and performance history will be essential criteria for burn-in modification approval. 4.3.3 Thermal impedance measurements). The thermal impedance measurements shall be performed in accordance with method 3131 of MIL-STD-750 using the guidelines in that method for determining IM, IH, tH, and tMD (and VC where appropriate). The thermal impedance limit used in screen 3c of 4.3 herein and subgroup 2 of table I shall comply with the thermal impedance graphs in figures 12, 13, 14, 15, and 16 (less than or equal to the curve value at the same tH time) and shall be less than the process determined statistical maximum limit as outlined in method 3131. See table III, subgroup 4 herein. 4.4 Conformance inspection. Conformance inspection shall be in accordance with MIL-PRF-19500, and as specified herein. If alternate screening is being performed in accordance with MIL-PRF-19500, a sample of screened devices shall be submitted to and pass the requirements of subgroups 1 and 2, of table I herein, inspection only (table E-VIb, group B, subgroup 1 is not required to be performed again if group B has already been satisfied in accordance with 4.4.2). 4.4.1 Group A inspection. Group A inspection shall be conducted in accordance with MIL-PRF-19500, and table I herein. 4.4.2 Group B inspection. Group B inspection shall be conducted in accordance with the conditions specified for subgroup testing in table E-VIa (JANS) of MIL-PRF-19500 and 4.4.2.1 herein. Electrical measurements (end-points) and delta requirements shall be in accordance with table I, subgroup 2 and 4.5.3 herein. See 4.4.2.2 herein for JAN, JANTX, and JANTXV, group B testing. Electrical measurements (end-points) and delta requirements for JAN, JANTX, and JANTXV, shall be after each step in 4.4.2.2 and shall be in accordance with table I, subgroup 2 and 4.5.3 herein. * 4.4.2.1 Group B inspection, table E-VIa (JANS) of MIL-PRF-19500. Subgroup Method Condition * B4 1037 VCB = -10 to -30 V dc. Adjust device current, or power, to achieve a minimum TJ of 100C. * B5 1027 VCB = -10 V dc; PD 100 percent of maximum rated PT (see 1.3). (NOTE: If a failure occurs, resubmission shall be at the test conditions of the original sample.) Option 1: 96 hours minimum sample size in accordance with MIL-PRF-19500, table E-VIa, adjust TA or PD to achieve TJ = +275C minimum. Option 2: 216 hours minimum, sample size = 45, c = 0; adjusted TA or PD to achieve a TJ = +225C minimum. B6 3131 RJA, RJC only (see 1.3). 12 Source: http://assist.dla.mil -- Downloaded: 2021-04-29T16:52Z Check the source to verify that this is the current version before use. MIL-PRF-19500/291V * 4.4.2.2 Group B inspection, (JAN, JANTX, and JANTXV). Separate samples may be used for each step. In the event of a lot failure, the resubmission requirements of MIL-PRF-19500 shall apply. In addition, all catastrophic failures during conformance inspection shall be analyzed to the extent possible to identify root cause and corrective action. Whenever a failure is identified as wafer lot and wafer processing related, the entire wafer lot and related devices assembled from the wafer lot shall be rejected unless an appropriate determined corrective action to eliminate the failures mode has been implemented and the devices from the wafer lot are screened to eliminate the failure mode. Step * Method Condition 1 1026 Steady-state life: 1,000 hours minimum, VCB = -10 dc, power and ambient shall be applied to achieve TJ = +150C minimum using a minimum of PD = 75 percent of maximum rated PT as defined in 1.3. n = 45 devices, c = 0. The sample size may be increased and the test time decreased so long as the devices are stressed for a total of 45,000 device hours minimum, and the actual time of test is at least 340 hours. 2 1048 Blocking life, TA = +150C, VCB = 80 percent of rated voltage, 48 hours minimum. n = 45 devices, c = 0. 3 1032 High-temperature life (non-operating), t = 340 hours, TA = +200C. n = 22, c = 0. 4.4.2.3 Group B sample selection. Samples selected from group B inspection shall meet all of the following requirements: a. For JAN, JANTX,and JANTXV samples shall be selected randomly from a minimum of three wafers (or from each wafer in the lot) from each wafer lot. For JANS, samples shall be selected from each inspection lot. See MIL-PRF-19500. b. Shall be chosen from an inspection lot that has been submitted to and passed table I, subgroup 2, conformance inspection. When the final lead finish is solder or any plating prone to oxidation at high temperature, the samples for life test (subgroups B4 and B5 for JANS, and group B for JAN, JANTX, and JANTXV) may be pulled prior to the application of final lead finish. 4.4.3 Group C inspection. Group C inspection shall be conducted in accordance with the conditions specified for subgroup testing in table E-VII of MIL-PRF-19500, and in 4.4.3.1 (JANS) and 4.4.3.2 (JAN, JANTX, and JANTXV) herein for group C testing. Electrical measurements (end-points) and delta requirements shall be in accordance with table I, subgroup 2 and 4.5.3 herein. * 4.4.3.1 Group C inspection, table E-VII (JANS) of MIL-PRF-19500. Subgroup * Method Condition C2 2036 Test condition E, (not applicable for UA, UB, UBC, UBN, and UBCN devices). C6 1026 1,000 hours, VCB = -10 V dc, power and ambient temperature shall be applied to the device to achieve TJ = +150C minimum, and minimum power dissipation of 75 percent of max rated PT (see 1.3 herein); n = 45, c = 0. The sample size may be increased and the test time decreased as long as the devices are stressed for a total of 45,000 device hours minimum, and the actual time of test is at least 340 hours. 13 Source: http://assist.dla.mil -- Downloaded: 2021-04-29T16:52Z Check the source to verify that this is the current version before use. MIL-PRF-19500/291V 4.4.3.2 Group C inspection, table E-VII (JAN, JANTX, and JANTXV) of MIL-PRF-19500. Subgroup Method Condition C2 2036 Test condition E, (not applicable for UA, UB, UBC, UBN, and UBCN devices). C5 3131 RJA RJC only (see 1.3). C6 Not applicable. 4.4.3.3 Group C sample selection. Samples for steps in group C shall be chosen at random from any inspection lot containing the intended package type and lead finish procured to the same specification which is submitted to and passes table I tests for conformance inspection. Testing of a subgroup using a single device type enclosed in the intended package type shall be considered as complying with the requirements for that subgroup. 4.4.4 Group D inspection. Conformance inspection for hardness assured JANS and JANTXV types shall include the group D tests specified in table II herein. These tests shall be performed as required in accordance with MIL-PRF-19500 and method 1019 of MIL-STD-750, for total ionizing dose or method 1017 of MIL-STD-750 for neutron fluence as applicable (see 6.2 herein), except group D, subgroup 2 may be performed separate from other subgroups. Alternate package options may also be substituted for the testing provided there is no adverse effect to the fluence profile. 4.4.5 Group E inspection. Group E inspection shall be conducted in accordance with the conditions specified for subgroup testing in appendix E, table E-IX of MIL-PRF-19500 and as specified in table III herein. Electrical measurements (end-points) shall be in accordance with table I, subgroup 2 herein. Delta measurements shall be in accordance with the applicable steps of 4.5.3. 4.5 Method of inspection. Methods of inspection shall be as specified in the appropriate tables and as follows. 4.5.1 Pulse measurements. Conditions for pulse measurement shall be as specified in section 4 of MIL-STD-750. 4.5.2 Input capacitance. This test shall be conducted in accordance with method 3240 of MIL-STD-750, except the output capacitor shall be omitted. * 4.5.3 Delta requirements. Delta requirements shall be as specified below: Step Inspection Method MIL-STD-750 Conditions Symbol Limit 1 Collector-base cutoff current 3036 Bias condition D, VCB = -50 V dc ICB02 (1) 100 percent of initial value or 10 nA dc, whichever is greater. 2 Forward current transfer ratio 3076 VCE = -10 V dc; IC = -150 mA dc; pulsed see 4.5.1 hFE4 (1) 25 percent change from initial reading. (1) Devices which exceed the table I limits for this test shall not be accepted. 14 Source: http://assist.dla.mil -- Downloaded: 2021-04-29T16:52Z Check the source to verify that this is the current version before use. MIL-PRF-19500/291V * TABLE I. Group A inspection. Inspection 1/ MIL-STD-750 Method Symbol Conditions Limit Min Unit Max Subgroup 1 2/ Visual and mechanical inspection 3/ 2071 Solderability 3/ 4/ 2026 n = 15 leads, c = 0 Resistance to solvents 3/ 4/ 5/ 1022 n = 15 devices, c = 0 Temp cycling 3/ 4/ 1051 Test condition C, 25 cycles. n = 22 devices, c = 0 Hermetic seal 4/ Fine leak Gross leak 1071 n = 22 devices, c = 0 Electrical measurements 4/ Table I, subgroup 2 Bond strength 3/ 4/ 2037 Precondition TA = +250C at t = 24 hours or TA = +300C at t = 2 hours n = 11 wires, c = 0 Decap internal visual (design verification) 4/ 2075 n = 4 devices, c = 0 Thermal impedance 3131 See 4.3.3 ZJX Collector to base cutoff current 3036 Bias condition D; VCB = -60 V dc ICBO1 -10 A dc Cutoff current, emitter to base 3061 Bias condition D; VEB = -5 V dc IEBO1 -10 A dc Breakdown voltage, collector to emitter 3011 Bias condition D; IC = -10 mA dc; pulsed (see 4.5.1) V(BR)CEO Collector to emitter cutoff current 3041 Bias condition C; VCE = -50 V dc ICES -50 nA dc Collector to base cutoff current 3036 Bias condition D; VCB = -50 V dc ICBO2 -10 nA dc Emitter to base cutoff current 3061 Bias condition D; VEB = -4 V dc IEBO2 -50 nA dc Subgroup 2 6/ See footnotes at end of table. 15 Source: http://assist.dla.mil -- Downloaded: 2021-04-29T16:52Z Check the source to verify that this is the current version before use. C/W -60 V dc MIL-PRF-19500/291V * TABLE I. Group A inspection - Continued. Inspection 1/ MIL-STD-750 Method Symbol Conditions Limit Min Unit Max Subgroup 2 - Continued Forward-current transfer ratio 2N2906A, L, UA, UB, UBC UBN, and UBCN 2N2907A, L, UA, UB, UBC UBN, and UBCN 3076 Forward-current transfer ratio 2N2906A, L, UA, UB, UBC UBN, and UBCN 2N2907A, L, UA, UB, UBC UBN, and UBCN 3076 Forward-current transfer ratio 2N2906A, L, UA, UB, UBC UBN, and UBCN 2N2907A, L, UA, UB, UBC UBN, and UBCN 3076 Forward-current transfer ratio 2N2906A, L, UA, UB, UBC UBN, and UBCN 2N2907A, L, UA, UB, UBC UBN, and UBCN 3076 Forward-current transfer ratio 2N2906A, L, UA, UB, UBC UBN, and UBCN 2N2907A, L, UA, UB, UBC UBN, and UBCN 3076 Collector-emitter saturation voltage 3071 IC = -150 mA dc; IB = -15 mA dc, pulsed (see 4.5.1) VCE(sat)1 -0.4 V dc Collector-emitter saturation voltage 3071 IC = -500 mA dc; IB = -50 mA dc; pulsed (see 4.5.1) VCE(sat)2 -1.6 V dc Base-emitter saturation voltage 3066 Test condition A; IC = -150 mA dc; IB = -15 mA dc; pulsed (see 4.5.1) VBE(sat)1 -1.3 V dc Base-emitter saturation voltage 3066 Test condition A; IC = -500 mA dc; IB = -50 mA dc; pulsed (see 4.5.1) VBE(sat)2 -2.6 V dc VCE = -10 V dc; IC = -0.1 mA dc hFE1 40 75 VCE = -10 V dc; IC = -1.0 mA dc VCE = -10 V dc; IC = -10 mA dc hFE2 40 175 100 450 hFE3 40 100 VCE = -10 V dc; IC = -150 mA dc; pulsed (see 4.5.1) VCE = -10 V dc; IC = -500 mA dc; pulsed (see 4.5.1) hFE4 40 120 100 300 hFE5 40 50 See footnotes at end of table. 16 Source: http://assist.dla.mil -- Downloaded: 2021-04-29T16:52Z Check the source to verify that this is the current version before use. -0.6 MIL-PRF-19500/291V TABLE I. Group A inspection - Continued. Inspection 1/ MIL-STD-750 Method Symbol Conditions Limit Min Unit Max Subgroup 3 High temperature operation Collector to base cutoff current TA = +150C 3036 Low temperature operation Forward-current transfer ratio 2N2906A, L, UA, UB, UBC, UBN, and UBCN 2N2907A, L, UA, UB, UBC, UBN, and UBCN Bias condition D; VCB = -50 V dc -10 ICBO3 A dc TA = -55C 3076 VCE = -10 V dc; IC = -10 mA dc hFE6 20 50 Subgroup 4 Small-signal short-circuit forward current transfer ratio 2N2906A, L, UA, UB, UBC, UBN, and UBCN 2N2907A, L, UA, UB, UBC, UBN, and UBCN 3206 Magnitude of small- signal short- circuit forward current transfer ratio 3306 VCE = -20 V dc; IC = -20 mA dc; f = 100 MHz |hfe| Open circuit output capacitance 3236 VCB = -10 V dc; IE = 0; 100 kHz f 1 MHz Cobo 8 pF Input capacitance (output open- circuited) 3240 VEB = -2.0 V dc; IC = 0; 100 kHz f 1 MHz See 4.5.2. Cibo 30 pF Saturated turn-on time (See figure 16) ton 45 ns Saturated turn-off time (See figure 17) toff 300 ns VCE = -10 V dc; IC = -1 mA dc; f = 1 kHz hfe 40 100 Subgroups 5, 6, and 7 Not applicable See footnotes at end of table. 17 Source: http://assist.dla.mil -- Downloaded: 2021-04-29T16:52Z Check the source to verify that this is the current version before use. 2.0 MIL-PRF-19500/291V TABLE I. Group A inspection - Continued. 1/ For sampling plan see MIL-PRF-19500. 2/ For resubmission of failed test subgroup of table I, double the sample size of the failed test or sequence of tests. A failure in table I, subgroup 1 shall not require retest of the entire subgroup. Only the failed test shall be rerun upon submission. 3/ Separate samples may be used. 4/ Not required for JANS devices. 5/ Not required for laser marked devices. 6/ This test required for the following end-point measurements only: Group B, subgroup 3, 4, and 5 (JANS). Group B, step 1 (TX and TXV). Group C, subgroup 2 and 6. 18 Source: http://assist.dla.mil -- Downloaded: 2021-04-29T16:52Z Check the source to verify that this is the current version before use. MIL-PRF-19500/291V * TABLE II. Group D inspection. Inspection 1/ 2/ 3/ Method MIL-STD-750 Conditions Limit Symbol Min Unit Max Subgroup 1 4/ Neutron irradiation 1017 Neutron exposure VCES = 0 V Collector to base cutoff current 3036 Bias condition D; VCB = -60 V dc ICBO1 -20 A dc Cutoff current, emitter to base 3061 Bias condition D; VEB = -5 V dc IEBO1 -20 A dc Breakdown voltage, collector to emitter 3011 Bias condition D; IC = -10 mA dc; pulsed (see 4.5.1) V(BR)CEO Collector to emitter cutoff current 3041 Bias condition C; VCE = -50 V dc ICES -100 nA dc Collector to base cutoff current 3036 Bias condition D; VCB = -50 V dc ICBO2 -20 nA dc Emitter to base cutoff current 3061 Bias condition D; VEB = -4 V dc IEBO2 -100 nA dc Forward-current transfer ratio M through H2N2906A M through H2N2907A 3076 VCE = -10 V dc; IC = -0.1 mA dc [hFE1] 5/ Forward-current transfer ratio M through H2N2906A M through H2N2907A 3076 Forward-current transfer ratio M through H2N2906A M through H2N2907A 3076 Forward-current transfer ratio M through H2N2906A M through H2N2907A 3076 Forward-current transfer ratio M through H2N2906A M through H2N2907A 3076 Collector-emitter saturation voltage 3071 IC = -150 mA dc; IB = -15 mA dc VCE(sat)1 -.46 V dc Collector-emitter saturation voltage 3071 IC = -500 mA dc; IB = -50 mA dc VCE(sat)2 -1.84 V dc Base-emitter saturation voltage 3066 Test condition A; IC = -150 mA dc; IB = -15 mA dc; pulsed (see 4.5.1) VBE(sat)1 Base-emitter saturation voltage 3066 Test condition A; IC = -500 mA dc; IB = -50 mA dc; pulsed (see 4.5.1) VBE(sat)2 -60 V dc [20] [37.5] VCE = -10 V dc; IC = -1.0 mA dc [hFE2] 5/ [20] [50] VCE = -10 V dc; IC = -10 mA dc 175 450 [hFE3] 5/ [20] [50] VCE = -10 V dc; IC = -150 mA dc [hFE4] 5/ [20] [50] VCE = -10 V dc; IC = -500 mA dc 120 300 [hFE5] 5/ [20] [25] -0.6 See footnotes at end of table. 19 Source: http://assist.dla.mil -- Downloaded: 2021-04-29T16:52Z Check the source to verify that this is the current version before use. -1.5 -3.0 V dc MIL-PRF-19500/291V TABLE II. Group D inspection - Continued. Inspection 1/ 2/ 3/ Method MIL-STD-750 Conditions Limit Symbol Min Unit Max Subgroup 2 Total dose irradiation 1019 Gamma exposure VCES = -48 V Collector to base cutoff current 3036 Bias condition D; VCB = -60 V dc ICBO1 -20 A dc Cutoff current, emitter to base 3061 Bias condition D; VEB = -5 V dc IEBO1 -20 A dc Breakdown voltage, collector to emitter 3011 Bias condition D; IC = -10 mA dc; pulsed (see 4.5.1) V(BR)CEO Collector to emitter cutoff current 3041 Bias condition C; VCE = -50 V dc ICES -100 nA dc Collector to base cutoff current 3036 Bias condition D; VCB = -50 V dc ICBO2 -20 nA dc Emitter to base cutoff current 3061 Bias condition D; VEB = -4 V dc IEBO2 -100 nA dc Forward-current transfer ratio M through H2N2906A M through H2N2907A 3076 VCE = -10 V dc; IC = -0.1 mA dc [hFE1] 5/ Forward-current transfer ratio M through H2N2906A M through H2N2907A 3076 Forward-current transfer ratio M through H2N2906A M through H2N2907A 3076 Forward-current transfer ratio M through H2N2906A M through H2N2907A 3076 Forward-current transfer ratio M through H2N2906A M through H2N2907A 3076 Collector-emitter saturation voltage 3071 IC = -150 mA dc; IB = -15 mA dc; VCE(sat)1 .46 V dc Collector-emitter saturation voltage 3071 IC = -500 mA dc; IB = -50 mA dc; VCE(sat)2 1.84 V dc -60 V dc [20] [37.5] [hFE2] 5/ VCE = -10 V dc; IC = -1.0 mA dc [20] [50] VCE = -10 V dc; IC = -10 mA dc 175 400 [hFE3] 5/ [20] [50] VCE = -10 V dc; IC = -150 mA dc [hFE4] 5/ [20] [50] VCE = -10 V dc; IC = -500 mA dc 120 300 [hFE5] 5/ [20] [25] See footnotes at end of table. 20 Source: http://assist.dla.mil -- Downloaded: 2021-04-29T16:52Z Check the source to verify that this is the current version before use. MIL-PRF-19500/291V TABLE II. Group D inspection - Continued. Inspection 1/ 2/ 3/ Method MIL-STD-750 Conditions Limit Unit Symbol Min Max -0.6 -1.5 Subgroup 2 - Continued. Base-emitter saturation voltage 3066 Test condition A; IC = -150 mA dc; IB = -15 mA dc; pulsed (see 4.5.1) VBE(sat)1 Base-emitter saturation voltage 3066 Test condition A; IC = -500 mA dc; IB = -50 mA dc; pulsed (see 4.5.1) VBE(sat)2 V dc -3.0 1/ Tests to be performed on all devices receiving radiation exposure. 2/ For sampling plan, see MIL-PRF-19500. 3/ Electrical characteristics apply to the corresponding AL, UA, UB, UBC, UBN, and UBCN suffix versions unless otherwise noted. 4/ See 6.2.f herein. 5/ See method 1019, of MIL-STD-750, for how to determine [hFE] by first calculating the delta (1/hFE) from the preand post-radiation hFE. Notice the [hFE] is not the same as hFE and cannot be measured directly. The [hFE] value can never exceed the pre-radiation minimum hFE that it is based upon. 21 Source: http://assist.dla.mil -- Downloaded: 2021-04-29T16:52Z Check the source to verify that this is the current version before use. MIL-PRF-19500/291V * TABLE III. Group E inspection (all quality levels) - for qualification only. Inspection MIL-STD-750 Method Qualification Conditions Subgroup 1 45 devices c=0 Temperature cycling (air to air) 1051 Hermetic seal 1071 Test condition C, 500 cycles. Fine leak Gross leak Electrical measurements See table I, subgroup 2 and 4.5.3 herein. Subgroup 2 * 45 devices c=0 1037 Intermittent life Electrical measurements VCB = -10 V dc, 6,000 cycles. Adjust device current, or power, to achieve a minimum TJ of 100C. See table I, subgroup 2 and 4.5.3 herein. Subgroup 4 Thermal resistance 3131 RJSP(IS) may be calculated but shall be measured once in the same package with a similar die size to confirm calculations (may apply to multiple slash sheets). 15 devices c=0 RJSP(AM) need be calculated only. Thermal impedance curves See MIL-PRF-19500, table E-IX, group E, subgroup 4. Sample size N/A Subgroup 5 Not applicable Subgroup 6 ESD 11 devices 1020 Subgroup 8 Reverse stability 45 devices c=0 1033 Condition B. 22 Source: http://assist.dla.mil -- Downloaded: 2021-04-29T16:52Z Check the source to verify that this is the current version before use. MIL-PRF-19500/291V NOTES: 1. This is the true inverse of the worst case thermal resistance value. All devices are capable of operating at TJ specified on this curve. Any parallel line to this curve will intersect the appropriate power for the desired maximum TJ allowed. 2. Derate design curve constrained by the maximum junction temperatures and power rating specified. (See 1.3 herein.) 3. Derate design curve chosen at TJ +150C, where the maximum temperature of electrical test is performed. 4. Derate design curve chosen at TJ +125C, and +110C to show power rating where most users want to limit TJ in their application. FIGURE 6. Temperature-power derating for 2N2906A, 2N2906AL, 2N2907A and 2N2907AL (RJA) leads .125 inch (3.18 mm) PCB (TO-18). 23 Source: http://assist.dla.mil -- Downloaded: 2021-04-29T16:52Z Check the source to verify that this is the current version before use. MIL-PRF-19500/291V Temperature-Power Derating Curve Tc =+25C; 2N2906A, 2N2906Al, 2N2907A, and 2N2907AL NOTES: 1. This is the true inverse of the worst case thermal resistance value. All devices are capable of operating at TJ specified on this curve. Any parallel line to this curve will intersect the appropriate power for the desired maximum TJ allowed. 2. Derate design curve constrained by the maximum junction temperatures and power rating specified. (See 1.3 herein.) 3. Derate design curve chosen at TJ +150C, where the maximum temperature of electrical test is performed. 4. Derate design curve chosen at TJ +125C, and +110C to show power rating where most users want to limit TJ in their application. FIGURE 7. Temperature-power derating for 2N2906A, 2N2906AL, 2N2907A and 2N2907AL (RJC), base case mount (TO-18). 24 Source: http://assist.dla.mil -- Downloaded: 2021-04-29T16:52Z Check the source to verify that this is the current version before use. MIL-PRF-19500/291V NOTES: 1. This is the true inverse of the worst case thermal resistance value. All devices are capable of operating at TJ specified on this curve. Any parallel line to this curve will intersect the appropriate power for the desired maximum TJ allowed. 2. Derate design curve constrained by the maximum junction temperatures and power rating specified. (See 1.3 herein.) 3. Derate design curve chosen at TJ +150C, where the maximum temperature of electrical test is performed. 4. Derate design curve chosen at TJ +125C, and +110C to show power rating where most users want to limit TJ in their application. FIGURE 8. Temperature-power derating for 2N2906AUA and 2N2907AUA (RJSP(IS)), infinite sink 4-points. 25 Source: http://assist.dla.mil -- Downloaded: 2021-04-29T16:52Z Check the source to verify that this is the current version before use. MIL-PRF-19500/291V Temperature-Power Derating Curve TSP(AM) = 25C 2N2906AUA, and 2N2907AUA NOTES: 1. This is the true inverse of the worst case thermal resistance value. All devices are capable of operating at TJ specified on this curve. Any parallel line to this curve will intersect the appropriate power for the desired maximum TJ allowed. 2. Derate design curve constrained by the maximum junction temperatures and power rating specified. (See 1.3 herein.) 3. Derate design curve chosen at TJ +150C, where the maximum temperature of electrical test is performed. 4. Derate design curve chosen at TJ +125C, and +110C to show power rating where most users want to limit TJ in their application. FIGURE 9. Temperature-power derating for 2N2906AUA and 2N2907AUA (RJSP(AM)) 4-point solder pad (adhesive mount to PCB). 26 Source: http://assist.dla.mil -- Downloaded: 2021-04-29T16:52Z Check the source to verify that this is the current version before use. MIL-PRF-19500/291V Temperature-Power Derating Curve TSP(is) = 25C 2N2906AUB, 2N2906AUBC, 2N2907AUB, and 2N2907AUBC NOTES: 1. This is the true inverse of the worst case thermal resistance value. All devices are capable of operating at TJ specified on this curve. Any parallel line to this curve will intersect the appropriate power for the desired maximum TJ allowed. 2. Derate design curve constrained by the maximum junction temperatures and power rating specified. (See 1.3 herein.) 3. Derate design curve chosen at TJ +150C, where the maximum temperature of electrical test is performed. 4. Derate design curve chosen at TJ +125C, and +110C to show power rating where most users want to limit TJ in their application. FIGURE 10. Temperature-power derating for 2N2906AUB, UBC, UBN, and UBCN 2N2907AUB, UBC,UBN, and UBCN (RJSP(IS)) infinite sink 3-point. 27 Source: http://assist.dla.mil -- Downloaded: 2021-04-29T16:52Z Check the source to verify that this is the current version before use. MIL-PRF-19500/291V Maximum Thermal Impedance 2N2906A and 2N2907A TO-18 package with 0.125" lead mount to PCB FIGURE 11. Thermal impedance graph (RJA) for 2N2906A, 2N2906AL, 2N2907A, and 2N2907AL (TO-18). 28 Source: http://assist.dla.mil -- Downloaded: 2021-04-29T16:52Z Check the source to verify that this is the current version before use. MIL-PRF-19500/291V Maximum Thermal Impedance 2N2906A and 2N2907A TO-18 package with case base in copper sink. FIGURE 12. Thermal impedance graph (RJC) for 2N2906A, 2N2906AL, 2N2907A, and 2N2907AL (TO-18). 29 Source: http://assist.dla.mil -- Downloaded: 2021-04-29T16:52Z Check the source to verify that this is the current version before use. MIL-PRF-19500/291V Maximum Thermal Impedance 2N2906A and 2N2907A (UA) 4 points solder pads (infinite sink mount to PCB). FIGURE 13. Thermal impedance graph (RJSP(IS)) for 2N906A and 2N2907A (UA). 30 Source: http://assist.dla.mil -- Downloaded: 2021-04-29T16:52Z Check the source to verify that this is the current version before use. MIL-PRF-19500/291V Maximum Thermal Impedance 2N2906A and 2N2907A (UA) 4 points solder pads (adhesive mount to PCB). FIGURE 14. Thermal impedance graph (RJSP(AM)) for 2N906A and 2N2907A (UA). 31 Source: http://assist.dla.mil -- Downloaded: 2021-04-29T16:52Z Check the source to verify that this is the current version before use. MIL-PRF-19500/291V Maximum Thermal Impedance 2N2906A and 2N2907A (UB and UBC) 3 points solder pads (infinite sink mount) to PCB. FIGURE 15. Thermal impedance graph (RJSP(IS)) for 2N906A and 2N2907A (UB, UBC, UBN, and UBCN). 32 Source: http://assist.dla.mil -- Downloaded: 2021-04-29T16:52Z Check the source to verify that this is the current version before use. MIL-PRF-19500/291V NOTES: 1. The rise time (tr) of the applied pulse shall be 2.0 ns, duty cycle 2 percent and the generator source impedance shall be 50 ohms. 2. Sampling oscilloscope: Zin 100 K ohms, Cin 12 pF, rise time 5 ns. FIGURE 16. Saturated turn-on switching time test circuit. NOTES: 1. The rise time (tr) of the applied pulse shall be 2.0 ns, duty cycle 2 percent and the generator source impedance shall be 50 ohms. 2. Sampling oscilloscope: Zin 100 K ohms, Cin 12 pF, rise time 5 ns. 3. Alternate test point for high impedance attenuating probe. FIGURE 17. Saturated turn-off switching time test circuit. 33 Source: http://assist.dla.mil -- Downloaded: 2021-04-29T16:52Z Check the source to verify that this is the current version before use. MIL-PRF-19500/291V 5. PACKAGING 5.1 Packaging. For acquisition purposes, the packaging requirements shall be as specified in the contract or order (see 6.2). When packaging of materiel is to be performed by DoD or in-house contractor personnel, these personnel need to contact the responsible packaging activity to ascertain packaging requirements. Packaging requirements are maintained by the Inventory Control Point's packaging activities within the Military Service or Defense Agency, or within the Military Service's system commands. Packaging data retrieval is available from the managing Military Department's or Defense Agency's automated packaging files, CD-ROM products, or by contacting the responsible packaging activity. 6. NOTES (This section contains information of a general or explanatory nature that may be helpful, but is not mandatory. The notes specified in MIL-PRF-19500 are applicable to this specification.) 6.1 Intended use. Semiconductors conforming to this specification are intended for original equipment design applications and logistic support of existing equipment. * 6.2 Acquisition requirements. Acquisition documents should specify the following: a. Title, number, and date of this specification. b. Packaging requirements (see 5.1). c. Lead finish (see 3.4.1). d. The complete Part or Identifying Number (PIN), see 1.2. e. For die acquisition, the letter version must be specified (see figures 5 and 6). f. For acquisition of RHA designed devices, table II, subgroup 1 testing of group D is optional. If subgroup 1 testing is desired, it must be specified in the contract. 6.3 Qualification. With respect to products requiring qualification, awards will be made only for products which are, at the time of award of contract, qualified for inclusion in Qualified Manufacturers List (QML 19500) whether or not such products have actually been so listed by that date. The attention of the contractors is called to these requirements, and manufacturers are urged to arrange to have the products that they propose to offer to the Federal Government tested for qualification in order that they may be eligible to be awarded contracts or orders for the products covered by this specification. Information pertaining to qualification of products may be obtained from DLA Land and Maritime, ATTN: VQE, P.O. Box 3990, Columbus, OH 43218-3990 or e-mail vqe.chief@dla.mil. An online listing of products qualified to this specification may be found in the Qualified Products Database (QPD) at https://assist.dla.mil . 6.4 Supersession information. Devices covered by this specification supersede the manufacturers' and users' Part or Identifying Number (PIN). The term Part or Identifying Number (PIN) is equivalent to the term part number which was previously used in this specification. This information in no way implies that manufacturers' PIN's are suitable as a substitute for the military PIN. 34 Source: http://assist.dla.mil -- Downloaded: 2021-04-29T16:52Z Check the source to verify that this is the current version before use. MIL-PRF-19500/291V 6.5 Suppliers of JANHC and JANKC die. The qualified JANHC and JANKC suppliers with the applicable letter version (example JANHCB2N2907A) will be identified on the QML. Die ordering information (1) (2) PIN 2N2906A 2N2907A Manufacturer 43611 34156 JANHCB2N2906A JANHCB2N2907A JANHCD2N2906A JANHCD2N2907A (1) For JANKC level, replace JANHC with JANKC. (2) JANHCA, JANKCA, JANHCC, and JANKCC versions are obsolete. * 6.6 Changes from previous issue. The margins of this specification are marked with asterisks to indicate where changes from the previous issue were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to the previous issue. Custodians: Army - CR Navy - EC Air Force - 85 NASA - NA DLA - CC Preparing activity: DLA - CC (Project 5961-2014-111) Review activities: Army - AR, MI, SM Navy - AS, MC Air Force - 19, 99 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https://assist.dla.mil. 35 Source: http://assist.dla.mil -- Downloaded: 2021-04-29T16:52Z Check the source to verify that this is the current version before use.