MODEL NUMBERS DC CONTROL H12CD4850 H12CD4890 H12D4825 H12D4850 H12D4875 H12D4890
H12WD4850 H12WD4890
AC C ONTROL H12CA4850 H12CA4890
OUTPUT SPECIFICATIONS ➀
Operating Voltage (47-63 Hz) [Vrms] 48-660 48-660 48-530 48-530 48-530 48-530
Max. Load Current ➂[Arms] 50 90 25 50 75 90
Min. Load Current, [mArms] 150 150 150 150 150 150
Transient Overvoltage [Vpk] 1200 1200 1200 1200 1200 1200
Max. Surge Current, (16.6ms) [Apk] 625 1200 250 625 1000 1200
Max. On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 1.6 1.6 1.6 1.6
Thermal Resistance Junction to Case (RθJC) [˚C/W] .63 .28 1.02 .63 .31 .28
Maximum I2 t for Fusing, (8.3 msec.) [A2sec] 1620 6000 260 1620 4150 6000
Max. Off-State Leakage Current @ Rated Voltage [mArms] 1.0 1.0 10 10 10 10
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]➁500 500 500 500 500 500
Max. Turn-On Time ➃1/2 Cycle (DC Control), 10.0 msec (AC Control)
Max. Turn-Off Time 1/2 Cycle (DC Control), 40.0 msec (AC Control)
Power Factor (Min.) with Max. Load 0.5 0.5 0.5 0.5 0.5 0.5
INPUT SPECIFICATIONS ➀DC CONTROL AC CONTROL
(H12CD PREFIX) (H12WD & H12D PREFIX) (H12CA PREFIX)
Control Voltage Range 4-8 Vdc 4-32Vdc 90-140 Vrms (60Hz)
Max. Turn-On Voltage 4.0 Vdc 4.0 Vdc 90 Vrms
Min. Turn-Off Voltage 1.0 Vdc 1.0 Vdc 10.0 Vrms
Nominal Input Impedance 220 Ohms See Note 5 8K Ohms
Typical Input Current
15 mA @ 5 Vdc 15 mA @ 5 Vdc
➄
15 mA @ 120 Vrms
GENERAL NOTES
➀All parameters at 25ºC unless otherwise specified.
➁Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➂Heat sinking required, for derating curves see page 2.
➃Turn-on time for DC control random turn-on versions is 0.02 msec.
➄Input circuitry incorporates active current limiter.
• 1200 Volt Blocking
• Panel Mount
• Up to 660 Vac
• Zero Voltage Switching
and Random Turn-On
• SCR Output
FastFax Document No.157
SERIES H12.081898, PAGE 1 OF 3
High voltage relays use IC driven cir-
cuits for switching loads up to 660
VAC. All models come with 1200
Volts blocking and are available with
either AC or DC input (coil) control.
Types H12CA, H12CD and H12WD are
snubberless (reduced leakage current).
Manufactured in Crydom’s ISO 9002
Certified facility for optimum product
performance and reliability.
Series H12
25-90Amp • 480 Vac • AC Output
©1998 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH,
Gewerbegebiet Im Schachen, D-66687 Nunkirchen, Germany • e-mail: vertrieb@crydom.com