INTEGRATED CIRCUITS DIVISION
www.ixysic.com
2R06
LCA715
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Absolute Maximum Ratings @ 25ºC
Electrical Characteristcs @ 25ºC
Parameter Ratings Units
Blocking Voltage 60 VP
Reverse Input Voltage 5 V
Input Control Current
Peak (10ms)
50 mA
1A
Input Power Dissipation 70 mW
Total Power Dissipation 1800 mW
ESD, Human Body Model 8 kV
Isolation Voltage, Input to Output 3750 Vrms
Operational Temperature -40 to +85 °C
Storage Temperature -40 to +125 °C
1 Derate linearly 6.67 mW / ºC
Parameter Conditions Symbol Min Typ Max Units
Output Characteristics
Load Current
Continuous, AC/DC Confi guration Continuous, Free Air IL
- - 2.2 Arms / ADC
Continuous, DC Confi guration - - 4 ADC
Peak t<10ms ILPK - - ±10 AP
On-Resistance 1
AC/DC Confi guration IF=5mA, IL=1A RON
- 0.12 0.15
DC Confi guration - 0.038 0.05
Off-State Leakage Current IF=0mA, VL=60VPILEAK --1 A
Switching Speeds
Turn-On IF=5mA, VL=10V ton - 0.7 2.5 ms
Turn-Off toff - 0.115 0.25 ms
Output Capacitance IF=0mA, f=1MHz
VL=10V COUT
- 110 200 pF
VL=50V - 60 -
Input Characteristics
Input Control Current to Activate IL=1A IF- 0.9 5 mA
Input Control Current to Deactivate - IF0.4 - - mA
Input Voltage Drop IF=5mA VF0.9 1.2 1.4 V
Reverse Input Current VR=5V IR--10A
Common Characteristics
Input to Output Capacitance - CI/O -3- pF
1 Measurement taken within 1 second of on-time.