TECHNICAL DATASHEET Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1A Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55C Power will not de-rate for the entire input voltage range Efficiency > 86.0% @ 115Vac & 230Vac NEC Class 2 / Limited Power Source (LPS) certified Overvoltage / Overcurrent / Over Temperature Protections * * * * * * Safety Standards CB Certified for worldwide use Model Number: DRC-12V60W1A Unit Weight: 0.22 kg (0.49 lb) Dimensions (L x W x D): 91 x 71 x 55.6 mm *This picture is for reference to DRC-12V60W series only. (3.58 x 2.80 x 2.19 inch) General Description The DRC-12V60W1A is part of the Chrome DIN Rail Power Supply series, which is designed for use in compact cabinets for home automations and the food and beverage industry. Delta's Chrome DIN Rail Power Supply series offers double isolated input. This means that no Earth connection is required thus resulting in low leakage current. This product provides a universal input voltage range of 90264Vac, and a wide temperature range of -25C to 71C. The Chrome series is certified to safety standard according to IEC/EN/UL 60950-1 Information Technology Equipment (ITE) and UL 508 Industrial Control Equipment (ICE). The series is also fully compliant with RoHS Directive 2011/65/EU for environmental protection. NEC Class 2 and Limited Power Source (LPS) approvals are available for this product. Model Information Chrome DIN Rail Power Supply Model Number Input Voltage Range Rated Output Voltage Rated Output Current DRC-12V60W1A 90-264Vac (125-375Vdc) 12Vdc 4.50A Model Numbering DR C- DIN Rail Product Series Output Voltage C - Isolation Class II Power Supply 1 12V 60W 1 A Output Power (60W series) Single Phase No PFC Z - Black Plastic Case G - Grey Plastic Case All parameters are specified at 25C ambient unless otherwise indicated. www.DeltaPSU.com (December 2018, Rev. 03) TECHNICAL DATASHEET Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1A Specifications Input Ratings / Characteristics Nominal Input Voltage 100-240Vac Input Voltage Range 90-264Vac Nominal Input Frequency 50-60Hz Input Frequency Range 47-63Hz Nominal DC Input Voltage* 125-375Vdc Input Current < 1.50A @ 115Vac, < 1.00A @ 230Vac Efficiency at 100% Load > 86.0% @ 115Vac & 230Vac Max Inrush Current (Cold Start) < 30A @ 115Vac, < 60A @ 230Vac Leakage Current < 0.25mA @ 240Vac * Fulfills test conditions for DC input. Safety approval for DC input can be obtained upon request. Output Ratings / Characteristics** Nominal Output Voltage 12Vdc Factory Set Point Tolerance 12Vdc 2% Output Voltage Adjustment Range 11.5-14.0Vdc Output Current 0-4.50A (54W max.) Output Power 54W Line Regulation < 0.5% (@ 90-264Vac input, 100% load) Load Regulation < 1% (@ 90-264Vac input, 0-100% load) PARD*** (20MHz) < 100mVpp Rise Time < 70ms @ nominal input (100% load) Start-up Time < 2,000ms @ nominal input (100% load) Hold-up Time > 16ms @ 115Vac (100% load) > 60ms @ 230Vac (100% load) Dynamic Response (Overshoot & Undershoot O/P Voltage) 5% @ 90-264Vac input, 10-100% load (Slew Rate: 0.1A/S, 50% duty cycle @ 5Hz to 1kHz) Start-up with Capacitive Loads 3,000F Max **For power de-rating from 55C to 71C, see power de-rating on page 3. ***PARD is measured with an AC coupling mode, 5cm wires, and in parallel with 0.1F ceramic capacitor & 47F electrolytic capacitor. 2 All parameters are specified at 25C ambient unless otherwise indicated. www.DeltaPSU.com (December 2018, Rev. 03) TECHNICAL DATASHEET Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1A Mechanical Case Cover Plastic Dimensions (L x W x D) 91 x 71 x 55.6 mm (3.58 x 2.80 x 2.19 inch) Unit Weight 0.22 kg (0.49 lb) Indicator Green LED (DC OK) Cooling System Terminal Wire Convection Input 2 Pins (Rated 300V/25A) Output 4 Pins (Rated 300V/25A) Input / Output AWG 24-12 Mounting Rail Standard TS35 DIN Rail in accordance with EN 60715 Noise (1 Meter from power supply) Sound Pressure Level (SPL) < 25dBA Environment Surrounding Air Temperature Operating Storage -25C to +71C -25C to +85C Power De-rating > 55C de-rate power by 2.5% / C Operating Humidity 5 to 95% RH (Non-Condensing) Operating Altitude 0 to 2,000 Meters (6,560 ft) Shock Test Operating IEC 60068-2-27, Half Sine Wave: 4G for a duration of 22ms, 3 shocks for each 3 directions, 9 times in total Vibration Operating IEC 60068-2-6, Sine Wave: 10-500Hz @ 19.6m/S (2G peak); 10 min per cycle, 60 min for all X, Y, Z directions Over Voltage Category II Pollution Degree 2 Protections Overvoltage < 17.4V, SELV Output, Latch Mode Overload / Overcurrent < 8A, Hiccup Mode, Non-Latching (Auto-Recovery) Over Temperature > 75C Surrounding Air Temperature @ 100% load, Latch Mode Short Circuit Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) Internal Fuse at L pin T3.15AH Degree of Protection IP20 Protection Against Shock Class II (No PE* connection is required) *PE: Primary Earth Reliability Data MTBF > 500,000 hrs. as per Telcordia SR-332 I/P: 100Vac, O/P: 100% load, Ta: 35C Expected Cap Life Time 10 years (115Vac & 230Vac, 50% load @ 40C) 3 All parameters are specified at 25C ambient unless otherwise indicated. www.DeltaPSU.com (December 2018, Rev. 03) TECHNICAL DATASHEET Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1A Safety Standards / Directives Safety Entry Low Voltage Electrical Safety SELV (EN 60950) TUV Bauart UL/cUL recognized CB scheme Industrial Control Equipment Class 2 Power Supply EN 60950-1 UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E131881) IEC 60950-1, Limited Power Source (LPS) UL/cUL listed UL 508 and CSA C22.2 No. 107.1-01 (File No. E338991) UL/cUL recognized UL 60950-1, CSA C22.2 No. 60950-1 (File No. E131881) CE In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU Material and Parts Galvanic Isolation RoHS Directive 2011/65/EU Compliant Input to Output 3.0KVac EMC Emissions (CE & RE) CISPR 32, EN 55032, FCC Title 47: Class A* Immunity EN 55024 Electrostatic Discharge IEC 61000-4-2 Level 3 Criteria A1) Air Discharge: 8kV Contact Discharge: 4kV Radiated Field IEC 61000-4-3 Level 2 Criteria A1) 80MHz-1GHz, 3V/M with 1kHz tone / 80% modulation Electrical Fast Transient / Burst IEC 61000-4-4 Level 3 Criteria A1) 1kV Surge IEC 61000-4-5 Level 3 Criteria A1) Common Mode2): 2kV Differential Mode3): 1kV Conducted IEC 61000-4-6 Level 2 Criteria A1) 150kHz-80MHz, 3Vrms Power Frequency Magnetic Fields IEC 61000-4-8 Criteria A1) 1A/Meter Voltage Dips Voltage Fluctuation and Flicker IEC 61000-4-11 > 95% dip; 0.5 cycle (10ms) IEC/EN 61000-3-3 1) Criteria A: Normal performance within the specification limits 2) Asymmetrical: Common mode (Line to earth) 3) Symmetrical: Differential mode (Line to line) *Warning: This is a Class A product. In a residential, commercial or light industrial environment it may cause radio interference. This product is not intended to be installed in a residential environment; in a commercial and light industrial environment with connection to the public mains supply, the user may be required to take adequate measures to reduce interference. 4 All parameters are specified at 25C ambient unless otherwise indicated. www.DeltaPSU.com (December 2018, Rev. 03) TECHNICAL DATASHEET Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1A Block Diagram Device Description 1) 2) 3) 4) 5) 5 Input terminal block connector Output terminal block connector DC voltage adjustment potentiometer DC OK control LED (Green) Universal mounting system All parameters are specified at 25C ambient unless otherwise indicated. www.DeltaPSU.com (December 2018, Rev. 03) TECHNICAL DATASHEET Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1A Dimensions L x W x D: 91 x 71 x 55.6 mm (3.58 x 2.09 x 2.19 inch) Engineering Data Output Load De-rating VS Surrounding Air Temperature Note 1. 2. 3. 4. Fig. 1 6 De-rating for Vertical Mounting Orientation > 55C de-rate power by 2.5% / C All parameters are specified at 25C ambient unless otherwise indicated. www.DeltaPSU.com (December 2018, Rev. 03) 5. Power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region, refer to the graph shown in Fig. 1. If the output capacity is not reduced when the surrounding air temperature exceeds its specification as defined on Page 3 under "Environment", the device may run into Over Temperature Protection. When activated, the output voltage will go into latch mode and recover when AC power recycles. In order for the device to function in the manner intended, it is also necessary to keep a safety distance as recommended in the safety instructions while the device is in operation. Depending on the surrounding air temperature and output load delivered by the power supply, the device can be very hot! If the device has to be mounted in any other orientation, please contact info@deltapsu.com for more details. TECHNICAL DATASHEET Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1A Output Load De-rating VS Input Voltage No output power de-rating across the entire input voltage range Assembly & Installation The power supply unit (PSU) can be mounted on 35mm DIN rails in accordance with EN 60715. The device should be installed with input terminal block at the bottom. Each device is delivered ready to install. Mounting Dismounting Fig. 2.1 Mounting Fig. 2.2 Dismounting Snap on the DIN rail as shown in Fig. 2.1: 1. Tilt the unit upwards and insert it onto the DIN rail. 2. Push downwards until stopped. 3. Press against the bottom front side for locking. 4. Shake the unit slightly to ensure that it is secured. To uninstall, pull or slide down the latch with screw driver as shown in Fig. 2.2. Then slide the power supply unit (PSU) in the opposite direction, release the latch and pull out the power supply unit (PSU) from the rail. 7 All parameters are specified at 25C ambient unless otherwise indicated. www.DeltaPSU.com (December 2018, Rev. 03) TECHNICAL DATASHEET Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1A Safety Instructions * * * * * * * ALWAYS switch mains of input power OFF before connecting and disconnecting the input voltage to the unit. If mains are not turned OFF, there is risk of explosion / severe damage. To guarantee sufficient convection cooling, keep a distance of 50mm (1.96 inch) above and below the device as well as a lateral distance of 25mm (0.98 inch) to other units. Note that the enclosure of the device can become very hot depending on the surrounding air temperature and load of the power supply. Risk of burns! DO NOT insert any objects into the unit. Hazardous voltages may be present for up to 5 minutes after the input mains voltage is disconnected. Do not touch the unit during this time. The power supplies unit should be installed in minimum IP54 rated enclosure. The power supplies are built in units and must be installed in a cabinet or room (condensation free environment and indoor location) that is relatively free of conductive contaminants. Functions Graph illustrating the Start-up Time, Rise Time, and Hold-up Time Start-up Time The time required for the output voltage to reach 90% of its final steady state set value, after the input voltage is applied. Rise Time The time required for the output voltage to change from 10% to 90% of its final steady state set value. Hold-up Time Time between the collapse of the AC input voltage, and the output falling to 95% of its steady state set value. 8 All parameters are specified at 25C ambient unless otherwise indicated. www.DeltaPSU.com (December 2018, Rev. 03) TECHNICAL DATASHEET Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1A Inrush Current Overload & Overcurrent Protections (Auto-Recovery) Inrush current is the peak, instantaneous, input current measured and, occurs when the input voltage is first applied. For AC input voltages, the maximum peak value of inrush current will occur during the first half cycle of the applied AC voltage. This peak value decreases exponentially during subsequent cycles of AC voltage. The power supply's Overload (OLP) and Over current (OCP) Protections will be activated when output current exceeds its specification as defined on Page 3 under "Protections". In such occurrence, once the power supply has reached its maximum power limit, the protection is activated and the power supply will go into "Hiccup mode" (Auto-Recovery). The power supply will recover once the fault condition of the OLP and OCP is removed and IO is back within the specifications. Over Temperature Protection (Latch Mode) Dynamic Response The power supply output voltage will remains within 5% of its steady state value, when subjected to a dynamic load from 10% to 100% of its rated current. 50% duty cycle / 5Hz to 1kHz As described in load de-rating section, the power supply also has Over Temperature Protection (OTP). In the event of a higher operating temperature at 100% load; or, when the operating temperature is beyond what is recommended in the de-rating graph, the OTP circuit will be activated. When activated, power supply will latch, until the surrounding air temperature drops to its normal operating temperature or the load is reduced as recommended in the de-rating graph. Removal/re-application of input AC voltage will then be required in order to restart. Short Circuit Protection (Auto-Recovery) The power supply's output OLP/OCP function also provides protection against short circuits. When a short circuit is applied, the output current will operate in "Hiccup mode", as shown in the illustration in the OLP/OCP section on this page. The power supply will return to normal operation after the short circuit is removed. External Input Protection Device Overvoltage Protection (Latch Mode) The power supply's overvoltage circuit will be activated when its internal feedback circuit fails. The output voltage shall not exceed its specifications defined on Page 3 under "Protections". Power supply will latch, and require removal/re-application of input AC voltage in order to restart. 9 The unit is protected with internal fuse (not replaceable) at L pin and it has been tested and approved on 20A (UL) and 16A (IEC) branch circuits without additional protection device. An external protection device is only required if the supplying branch has an ampacity greater than above. Thus, if an external protective device is necessary, or, utilized, a minimum value of 16A B- or 8A Ccharacteristic breaker should be used. All parameters are specified at 25C ambient unless otherwise indicated. www.DeltaPSU.com (December 2018, Rev. 03) TECHNICAL DATASHEET Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1A Others Delta RoHS Compliant Restriction of the usage of hazardous substances The European directive 2011/65/EU limits the maximum impurity level of homogeneous materials such as lead, mercury, cadmium, chrome, polybrominated flame retardants PBB and PBDE for the use in electrical and electronic equipment. RoHS is the abbreviation for "Restriction of the use of certain hazardous substances in electrical and electronic equipment". This product conforms to this standard. Attention Delta provides all information in the datasheets on an "AS IS" basis and does not offer any kind of warranty through the information for using the product. In the event of any discrepancy between the information in the catalog and datasheets, the datasheets shall prevail (please refer to www.DeltaPSU.com for the latest datasheets information). Delta shall have no liability of indemnification for any claim or action arising from any error for the provided information in the datasheets. Customer shall take its responsibility for evaluation of using the product before placing an order with Delta. Delta reserves the right to make changes to the information described in the datasheets without notice. 10 All parameters are specified at 25C ambient unless otherwise indicated. www.DeltaPSU.com (December 2018, Rev. 03)