KPS5,KPS10,KPS15Handbook Part Number 17165 Safety Class of Protection Input Parameters RATED INPUT VOLTAGE RANGE 100 - 240V AC INPUT FREQUENCY 47- 63Hz RATED INPUT CURRENT 1.5A INRUSH CURRENT (132/264VAC) 25/50 (COLD START) These products are designed for the following parameters : Material Group IIIa, Pollution Degree 2, Overvoltage Category II, Class II, Indoor use as part of an overall equipment such that the product is accessible to service engineers only. Safety approvals UL60950 and CSA 60950 EN60950,Class II and CE (LVD) mark. Fuse Information Internal fuse (F1): T2.2AL, 250V Input Connector Conducted and Radiated EMI Outputs EN55022-B, FCC Class B Immunity EN61000-4-2,EN61000-4-3,EN6100-4-4,EN61000-4-6, EN61000-4-8 Output Parameters Models Model Output Voltage (V) Output Current (A) KPS5-3R3 3.3 1.25 KPS5-5 5.0 1.00 KPS5-12 12.0 0.42 KPS5-15 15.0 0.33 KPS5-24 24.0 0.23 KPS10-3R3 3.3 2.50 KPS10-5 5.0 2.00 KPS10-12 12.0 0.84 KPS10-15 15.0 0.67 KPS10-24 24.0 0.42 KPS15-3R3 3.3 3.00 KPS15-5 5.0 3.00 KPS15-12 12.0 1.25 KPS15-15 15.0 1.00 KPS15-24 24.0 0.63 Output Limitations Adjusting output voltage beyond the stated range may cause the overvoltage protection (OVP) to operate, whereby the output will cycle on and off or latch off. To reset for normal operation simply adjust the potentiometer to reduce the ouput voltage to within it's range or cycle the input off then on if the unit has latched off. Important safety instructions Servicing These products are not customer serviceable. Repairs may only be carried out by Lambda UK or their authorised agents. These products are not authorised for use as critical components in nuclear control systems, life support systems or equipment for use in hazardous environments without the express written approval of the Managing Director of Coutant Lambda Ltd. Approval Limitations: Use in North America (AC units only) When this product is used on 180VAC-250VAC mains with no neutral, connect the two live wires to L(live) and N (neutral) terminals on the input connector. In this instance double pole fusing is required. High Voltage Warning Dangerous voltages present within the power supply. The proffesional installer must protect service personnel from inadvertant contact with these dangerous voltages in the end equipment. Environmental parameters Operation Temperature: Humidity: (Neutral) (Live) 0 to +700C ( >400C -700C derate at 2.5%/0C ) 10 to 95% RH, non-condensing Storage and Transportation Temperature: -200C to +850C Humidity: 10% to 95% RH, non-condensing Shock <196.1 m/s 2 (20G) (Neutral) (Live) Vibration 23.52 m/s 2 (10-55HZ): constant sweep 1 min X , Y, Z for one hour) Cooling Convection Level of insulation Dielectric Strength testing is carried out as follows: Primary mains circuit to earth - 1.5kVAC.Primary mains circuits to secondary -3kVAC. Outputs to each other and to earth are isolated to 500VAC. (Neutral) (Live) General installation instructions The ZP family of component power supplies is designed for use within other equipment or enclosures which restrict access to authorised competent personnel only. For safe installation and operation of this product, carefully follow the instructions listed below. i) These products are supplied open frame ii) These products are Class II and must be installed in accordance with Class II requirements of IE/EN/UL/CSAC60950. iii) These products are IPX0, and therefore chemicals/solvents, cleaning agents and other liquids must not be used. KPS5,KPS10,KPS15Handbook KPS5 Outline Drawing Part Number 17165 KPS10 Outline Drawing KPS15 Outline Drawing CEL Part No. 17165 Issue 02, Febuary 2007 Coutant Lambda Limited, Kingsley Avenue, Ilfracombe, Devon, EX34 8ES. Telephone - Sales and Service (01271) 856666. Head Office and Works (01271) 856600. Facsimile (01271) 864894. WEBSITE: www.lambda-gb.com