KPS5,KPS10,KPS15Handbook Part Number 17165
Input Parameters
Output Limitations
Adjusting output voltage beyond the stated range may cause the overvoltage protection (OVP)
to operate, whereby the output will cycle on and off or latch off. To reset for normal operation
simply adjust the potentiometer to reduce the ouput voltage to within it’s range or cycle the
input off then on if the unit has latched off.
RATED INPUT VOLTAGE RANGE 100 - 240V AC
INPUT FREQUENCY 47- 63Hz
RATED INPUT CURRENT 1.5A
INRUSH CURRENT (132/264VAC) 25/50 (COLD START)
Outputs
Servicing
These products are not customer serviceable. Repairs may only be carried out by Lambda UK or their
authorised agents. These products are not authorised for use as critical components in nuclear control
systems, life support systems or equipment for use in hazardous environments without the express
written approval of the Managing Director of Coutant Lambda Ltd.
Approval Limitations: Use in North America (AC units only)
When this product is used on 180VAC-250VAC mains with no neutral, connect the two live wires to
L(live) and N (neutral) terminals on the input connector. In this instance double pole fusing is required.
High Voltage Warning
Dangerous voltages present within the power supply. The proffesional installer must protect service
personnel from inadvertant contact with these dangerous voltages in the end equipment.
Important safety instructions
UL60950 and CSA 60950 EN60950,Class II and CE (LVD) mark.
Operation
Temperature: 0 to +700C ( >400C -700C derate at 2.5%/0C )
Humidity: 10 to 95% RH, non-condensing
Storage and Transportation
Temperature: -200C to +850C
Humidity: 10% to 95% RH, non-condensing
Shock
<196.1 m/s 2 (20G)
Vibration
23.52 m/s 2 (10-55HZ): constant sweep 1 min X , Y, Z for one hour)
Cooling
Convection
Models
Model Output Voltage (V) Output Current (A)
KPS5-3R3 3.3 1.25
KPS5-5 5.0 1.00
KPS5-12 12.0 0.42
KPS5-15 15.0 0.33
KPS5-24 24.0 0.23
KPS10-3R3 3.3 2.50
KPS10-5 5.0 2.00
KPS10-12 12.0 0.84
KPS10-15 15.0 0.67
KPS10-24 24.0 0.42
KPS15-3R3 3.3 3.00
KPS15-5 5.0 3.00
KPS15-12 12.0 1.25
KPS15-15 15.0 1.00
KPS15-24 24.0 0.63
Conducted and Radiated EMI
EN55022-B, FCC Class B
Immunity
EN61000-4-2,EN61000-4-3,EN6100-4-4,EN61000-4-6, EN61000-4-8
Output Parameters
Safety approvals
Environmental parameters
The ZP family of component power supplies is designed for use within other equipment or
enclosures which restrict access to authorised competent personnel only. For safe installation and
operation of this product, carefully follow the instructions listed below.
i) These products are supplied open frame
ii) These products are Class II and must be installed in accordance with Class II requirements of
IE/EN/UL/CSAC60950.
iii) These products are IPX0, and therefore chemicals/solvents, cleaning agents and other liquids
must not be used.
General installation instructions
Dielectric Strength testing is carried out as follows:
Primary mains circuit to earth - 1.5kVAC.Primary mains circuits to secondary -3kVAC.
Outputs to each other and to earth are isolated to 500VAC.
Level of insulation
Safety Class of Protection
These products are designed for the following parameters : Material Group IIIa, Pollution Degree 2,
Overvoltage Category II, Class II, Indoor use as part of an overall equipment such that the product is
accessible to service engineers only.
Fuse Information
Internal fuse (F1): T2.2AL, 250V
(Neutral)
(Live)
(Neutral)
(Live)
Input Connector
(Neutral)
(Live)
KPS5,KPS10,KPS15Handbook Part Number 17165
KPS5 Outline Drawing KPS10 Outline Drawing
CEL Part No. 17165 Issue 02, Febuary 2007
Coutant Lambda Limited,
Kingsley Avenue,
Ilfracombe,
Devon, EX34 8ES.
Telephone - Sales and Service (01271) 856666.
Head Office and Works (01271) 856600.
Facsimile (01271) 864894.
WEBSITE: www.lambda-gb.com
KPS15 Outline Drawing