High Power Wireless Transmitters Ethernet or Internet Connection zED-THP-LCD shown smaller than actual size. zED-TC-LCD-DC-H2 shown smaller than actual size. Inputs Available: * Temperature * Barometric Pressure * Humidity * Dual Thermocouple * Analog Voltage or Current zED Series Optional U Web Server U Alarms by Email or Text Message U No Special Software Required U High Power--1 Kilometer Range U NEMA 4 (IP65) Enclosure U Low Power Option The rugged high-performance, high power OMEGA(R) wiSeries wireless sensor/transmitter system provides Web-based monitoring of Analog Voltage and Current, Temperature, Humidity and Barometric Pressure. The radio is a high power IEEE 802.15.4 compliant transmitter operating at 2.4 GHz designed to transmit over greater distances and through more obstructions than the standard transmitter. These wireless sensors transmit 1000 m (3280')-- without obstructions or interferences-- to a zCDR coordinator or wi8/wiDR meter-controller. The coordinators and controllers connect directly to an Ethernet network and the Internet and serve active Web Pages to display and chart the data. You can monitor and record analog voltage and current, temperature, relative humidity, and barometric pressure over an Ethernet network or the Internet without any special software--just your Web Browser. These wireless sensors are designed for demanding industrial applications indoors and harsh outdoor environments. The electronics are protected in a rugged weatherproof polycarbonate NEMA 4 (IP65) rated housing. The rugged industrial sensors are supplied with 3 m (10') of cable. external probes Temperature/humidity or barometric pressure/ temperature probe included with zED-THP-P. Lug mount probe included with zED-TP2-P. Stick probe included with zED-TP1-P. Meter-Controller/Coordinator zCDR shown smaller than actual size. For more information, visit omega.com wi833-ZT meter controller/ coordinator shown smaller than actual size. For more information, visit omega.com W-51 or within any narrow range such as [20 to 30C (68 to 86F)]. OMEGA offers an OPC Server software that makes it easy to integrate the zSeries wireless sensor system with many popular Data Acquisition and Automation programs offered by Omega, Wonderware, iConics, Intellution, Rockwell Automation, and National Instruments, among others. Specifications Internet Enabled! Wireless Transmitters Wireless transmitters are available with external probes appropriate for an almost unlimited variety of industrial and commercial applications. OMEGA offers a selection of end devices for a variety of applications. The high power end device supports one external sensor. The external sensors are designed for harsh environments such as outdoor weather, in HVAC ducts, in freezers and refrigerators. The high power end devices run on either AC power, low voltage power, or batteries. The AC version (zED-P, zED-LCD) is powered by a 5 Vdc universal AC power adapter that operates on any voltage worldwide (110 to 240 Vac). Should AC power fail, the unit can operate on a 3.6V ultra-long-life lithium back-up battery (included). A low power option (zED-DC) operates at 10 to 30 Vdc, or 24Vac. The completely wireless End Devices are powered by two AA (zED-LCD-AA) or two C-cell (zEDCCELL) alkaline batteries. These End Devices can operate for weeks, months, or years before changing the batteries. Battery life depends on the type of sensor and other user settings such as the frequency of transmission. Alarm and Email The zSeries wireless sensor system can trigger an alarm if variables go above or below a set point that you determine. Your alarm can be sent by email to a single user or to a group distribution list, including text messages to cell phones and PDAs. The OMEGA "MailNotifier" software is a free and easy program for this application.The meter-controller connects directly to an Ethernet Network or the Internet. Unlike an RS232 or USB device, it does not require a host computer. Embedded Web Server The wireless sensor system is easy to install, simple to operate, and features OMEGA's award-winning iServer technology with an Embedded Web Server that requires no special software. Charts and Graphs Relative Humidity Accuracy/Range (zED-THP-x, zED-BTHP-x): 2% for 10 to 90%; 3% for 5 to 10% and 90 to 95%; 4% for 0 to 5% and 95 to 100% Hysteresis: 1% RH Non-Linearity: 3% Repeatability: 0.1% Resolution: 0.1% Temperature Accuracy/Range zED-TP1-x, zED-TP2-x: 0.5C for 10 to 85C (0.9F for 50 to 185F); 1C for -40 to 10C and 85 to 125C (1.8F for -40 to 50F and 185 to 257F) zED-THP-x, zED-THP2-x: 0.5C for 5 to 45C (0.9F for 41 to 113F); up to 1.5C for -40 to 5C and 45 to 124C (up to 2.7F for -40 to 41F and 113 to 255F) ZED-BTHP-x: 0.5C for 5 to 45C (0.9F for 41 to 133F) up to 1.5C for -40 to 5C and 45 to 85C (up to 2.7F for -40 to 41F and 113 to 185F) zED-BTP-x: 0.8C @ 20C (1.5F @ 68F); 2C for 40 to 85C (3.6F for -40 to 185F) Repeatability: 0.1C for zED-THP-x, zED-BTHP-x Resolution: 0.1C Barometric Pressure Accuracy/Range (zED-BTP-x, zED-BTHP-x): 2 mbar for 10 mbar to 1100 mbar (1 KPa to 110 KPa) Resolution: 0.1 mbar Probe Specifications Industrial Probe (zED-BTP-x, -BTHP-x, zED-THP-x): SS 316 housing, 137 x O16 mm (5 x O0.63") (zED-THP2-x): SS 316 housing 78 x O16 mm (3.1 x O0.63") Stick Probe (zED-TP1-x): ABS tubing, 152.4 x O6.35 mm (6 x O0.25") Lug Mounted Probe (zED-TP2-x): Copper tubing, 53.4 x O7.92 mm (2.1 x O0.312"); mounting hole O4.72 mm (O0.186") Cable: zED-TP1-x, -TP2-x, zED-THP-x: 3 m (10') L x O2.62 mm (0.103"); -80 to 200C (-112 to 392F) zED-BTP-x, -BTHP-x: 3 m (10') L x O4.45 mm (0.175"); -55 to 105C (-67 to 221F) o = diameter Thermocouple Input Temperature Accuracy/Range: Refer to T/C chart, on next page Temperature Stability: 0.08C/C The zSeries system serves Active Web Pages to Temperature Coefficient: 25 ppm/C display real time readings and charts of Analog Voltage Thermocouple Cold End Tracking: 0.1C/C and Current, Temperature, Humidity, and Barometric Pressure. You can also log data in standard data Thermocouple Lead Resistance: 100 maximum formats for use in a spreadsheet or data acquisition Thermocouple Type (ITS 90): J, K, T, E, R, S, B, C, N, L (DIN J) program such as Excel or Visual Basic. Warm-Up to Rated Accuracy: 30 minutes OMEGA offers a free and easy to use program for Analog Input logging data to Excel. The virtual chart viewed on the Voltage Input: Differential; bipolar; 100 mV, 1V, 10V web page is a JAVATM Applet that records a chart Input Impedance: 400 k for voltage over the LAN or Internet in real time. With the OMEGA Current Input: Differential; bipolar; 20 mA (5 load) zSeries system there is no need to invest time and Accuracy: 1% full range @ 25C money learning a proprietary software program to log Reading Rate: Periodic (1 sample/update) or continuous or chart the data. Chart scales are fully adjustable on (20 samples/second) the fly. For example, the chart can display one minute, A/D Conversion: Sigma-Delta one hour, one day, one week, one month or one year. Resolution: 16-bits Temperature and humidity can be charted across the full span [-40 to 125C (-40 to 257F), and 0 to 100% RH] Temperature Coefficient: 50 ppm/C W-52 W 15.0 (0.59) 51.97 (2.046) 107.7 (4.24) 82.0 (3.23) 110.0 (4.33) Dimensions: mm (inch) o = diameter 146.3 (5.76) 5.99 (0.236) 39.7 (1.56) 50.8 (2.00) 104.2 (4.10) 9.1 (0.36) ANTENNA ANTENNA 123.77 (4.873) 135.8 (5.35) 3.56 (0.140) 4 PLCS O3.56 (0.140) 4 PLCS FOR #6 SCREW zED-TP1-DC-H2 zED-TP2-DC-H2 zED-THP-DC-H2 zED-THP2-DC-H2 zED-BTP-DC-H2 zED-BTHP-DC-H2 96.5 (3.80) TOP VIEW (COVER REMOVED) zED-THP2-CCELL-H zED-THP2-LCD-AA-H 78.3 (3.08) (mounting pattern same as vertical models) zED-TP1-LCD-DC-H2 zED-TP2-LCD-DC-H2 zED-THP1-LCD-DC-H2 zED-THP2-LCD-DC-H2 zED-BTP-LCD-DC-H2 zED-BTHP-LCD-DC-H2 44.5 (1.75) 57.2 (2.25) QUICK DISCONNECT CONNECTORS zED-THP2LCD-AA-H zED-THP2-CCELL-H (SHOWN WITH COVER REMOVED) QUICK DISCONNECT CONNECTOR 78.1 (3.08) 25.4 (1.00) DC POWER GLAND CONNECTOR 2.25 (57.1) SENSOR QUICK DISCONNECT CONNECTOR 15.9 (0.63) DIA M12 CABLE GLAND CONNECTORS zED-TC-CCELL zED-TC-LCD-AA 1 CABLE GLAND Power (zED-x-CCELL) zED-THP-CCELL/-DCELL/-LCD-AA zED-TP1-CCELL/-DCELL/-LCD-AA zED-TP2-CCELL/-DCELL/-LCD-AA zED-BTP-CCELL/-DCELL/-LCD-AA zED-BTHP-CCELL/-DCELL/-LCD-AA (earlier gland version) 2 CABLE GLANDS 25 (1.0) zED-TC-H2 zED-VI-DC-H2 zED-TP2-LCD-DC-H2 zED-VI-LCD-DC-H2 Alkaline Battery: Two C-cell 1.5 Vdc (included) Lifetime: Estimate of 5 years with frequency of 1 reading per 2 minutes Environmental QUICK DISCONNECT CONNECTOR Operating Temperature: zED-x-P; zED-x-DC-H2: -20 to 70C (-4 to 158F), 90% RH non-condensing zED-x-CCELL: -18 to 55C (-0.4 to 131F), 90% RH non-condensing zED-x-LCD-x: -10 to 60C (14 to 140F), 90% RH non-condensing CABLE GLAND Common Mode Rejection: 105 dB Normal Mode Rejection: 98 dB Warm-Up to Rated Accuracy: 30 minutes Wireless Communication Packaging Standard: IEEE 802.15.4, DSSS Frequency: 2.4 GHz (2400 to 2483.5 MHz), 16 channels Network Topology: Star topology Range: Up to 1000 m (3280') without obstructions or interference Enclosure Material: Polycarbonate Enclosure Protection: NEMA 4 (IP65) Enclosure Dimensions: 135.9 L x 82 W x 39 mm D (5.35 x 3.23 x 1.56") General Power (zED-x-P, zED-x-LCD) Agency Approval: FCC Part 15C; CE EMC; 2004/108/EC, Power Input: 5 Vdc LVD 2006/95/EC, RTT&E 1999/5/EC, SRRC Consumption: 0.8 W maximum Software: iConnect (configuration software for the Ethernet Safety Qualified AC Power interface), iLog (Excel-based software for automatic data Adaptor (Included): logging), and Mail Notifier (email alarm notification software) Nominal Output: 5 Vdc @ 0.6 A Input: 100 to 240 Vac, 50/60 Hz Operating Temperature: 0 to 40C Thermocouple Chart (32 to 104F) Accuracy Range Input Type Lithium Back-up Battery: One 3.6 Vdc (included) 0.4C (0.7F) -210 to 760C (-346 to 1400F) Iron - Constantan Lifetime: Estimate of 2 years with (R) frequency of 1 reading per 2 minutes 1.0C/0.4C -270 to -160C/-160 to 1372C (R) CHROMEGA - ALOMEGA (-454 to -256F/-256 to 2502F) (7 months with -TC option, (1.8F/0.7F) 8 months with -VI) 1.0C/0.4C -270 to -190C/-190 to 400C Copper - Constantan Power (zED-x-DC-H2) (1.8F/0.7F) (-454 to -310F/-310 to 752F) (R) Power Input: 10 to 30 Vdc, or 24 Vac 10% 1.0C/0.4C -270 to -220C/-220 to 1000C CHROMEGA - Constantan (-454 to -364F/-364 to 1832F) (1.8F/0.7F) Consumption: 1.5 W maximum 1.0C/0.5C -50 to 40C/40 to 1768C Isolation Dielectric per 60 Seconds: 1000 Vdc Pt/13%Rh-Pt (1.8F/0.9F) (-58 to 104F/104 to 3214F) Universal AC 1.0C/0.5C -50 to 100C/100 to 1768C Pt/10%Rh-Pt adaptor is (1.8F/0.9F) (-58 to 212F/212 to 3214F) included with all 1.0C/0.5C 100 to 640C/640 to 1820C AC powered Pt/30%Rh-Pt/6%Rh (1.8F/0.9F) (212 to 1184F/1184 to 3308F) models. 0.4C (0.7F) 0 to 2320C (32 to 4208F) W/5%Re-W/26%Re 1.0C/0.4C -250 to -100C/-100 to 1300C Nicrosil - Nisil (1.8F/0.7F) (-418 to -148F/-148 to 2372F) 0.4C (0.7F) -200 to 900C (-328 to 1652F) J DIN L W-53 High Power Wireless Transmitters A complete wireless system requires at least: 1 end device (zED-x, zED-x-P, zED-x-LCD, zED-x-DC, or zED-x-CCELL) and 1 coordinator or meter/controller receiver (zCDR, wi8xx-ZT, or wiDRxx-ZT). To Order Visit omega.com/zed-p_series for Pricing and Details Model No. Description Wireless End Device zED-TP1-P Temperature sensor with stick probe, AC powered zED-THP-P Temperature and humidity sensor, AC powered zED-TC-P Dual thermocouple input, AC powered zED-TP2-LCD Temperature sensor with lug mount probe, AC powered, LCD display zED-THP-LCD Temperature and humidity sensor, AC powered, LCD display zED-TC-LCD Dual thermocouple input, AC powered, LCD display zED-VI-LCD Analog input, AC powered, LCD display zED-THP-CCELL-H Temperature and humidity sensor, battery powered, horizontal case zED-THP2-CCELL-H Short probe with temp and humidity sensor, battery powered, horizontal case zED-BTP-CCELL-H Barometric pressure and temp sensor, battery powered, horizontal case zED-BTHP-CCELL-H Barometric pressure, temp and humidity sensor, battery powered, horizontal case zED-TC-CCELL-H Dual thermocouple input, battery powered, horizontal case zED-THP-LCD-CCELL-H Temperature and humidity sensor, battery powered, LCD display, horizontal case zED-THP2-LCD-CCELL-H Short probe with temp and humidity sensor, battery powered, LCD display, horizontal case zED-TC-LCD-CCELL-H Dual thermocouple input, battery powered, LCD display, horizontal case zED-THP-DC-H2 Temperature and humidity sensor, low voltage powered, horizontal case zED-TC-DC-H2 Dual thermocouple input, low voltage powered, horizontal case zED-THP-LCD-DC-H2 Temperature and humidity sensor, low voltage powered, LCD display, horizontal case zED-TC-LCD-DC-H2 Dual thermocouple input, low voltage powered, LCD display, horizontal case zED-VI-LCD-DC-H2 Analog input, low voltage powered, LCD display, horizontal case Wireless Coordinator and Meter/Controller/Coordinator (Receivers) zCDR Coordinator, which can support up to 32 end devices (any zED type except zED-VI) zCDR-VI Coordinator, which can support up to 32 analog input only end devices wi833-ZT Meter/controller, which can support up to 8 temperature only end devices, with 2 relays: Form "C" SPDT 3 A @ 120 Vac, 3 A @ 240 Vac, embedded Ethernet, 90 to 240 Vac, 50/60 Hz wi853-ZT Meter/controller, supports up to 8 temperature only end devices, with analog output 0 to 10 Vdc or 0 to 20 mA @ 500 max and Form "C" SPDT 3 A @ 120 Vac, 3 A @ 240 Vac, embedded Ethernet, 90 to 240 Vac, 50/60 Hz wiDR22-ZT DIN rail monitor/controller, supports up to 8 temperature only end devices, with 2 solid state relays (SSRs): 0.5 A @ 120/240 Vac continuous, embedded Ethernet, 90 to 240 Vac, 50/60 Hz wiDR44-ZT-DC DIN rail monitor/controller, supports up to 8 temperature only end devices, with 2 pulsed 10 Vdc @ 20 mA (for use with external SSR), embedded Ethernet, low power option 12 to 36 Vdc, 24 Vac Calibration Description CAL-3-HU NIST traceable calibration certificate; three humidity points: 25%, 50%, 75%, 1 temperature point of 25C (for new units) CAL-3-HU-P-T NIST traceable calibration certificate; three humidity, barometric pressure, and temperature points (for new units) CAL-3-P NIST traceable calibration certificate; three barometric pressure points, and temperature 25C (for new units) CT485B-CAL-KIT Calibration kit, 33% and 75% RH standards Note: Because of transmission frequency regulations, these products may only be used in the US, Canada, Europe, and China. 2 type K thermocouples with 1m of 24 AWG PFA insulated wire with stripped lead termination included with -TC models. For the meter/controllers, other output options are available, please contact our Sales Department. Comes complete with software, 2 C-cell batteries, or AC power adaptor, and operator's manual. Ordering Examples: Two zED-TP2-P high power end devices with external temperature sensor in lug mounting probe housing and 3 m (10') cable, and zCDR, coordinator. CAL-3-HU, NIST traceable calibration certificate for new unit. W-54 W