SPECIFICATION
MODEL PLP-30-12 PLP-30-24 PLP-30-48
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT
CURRENT ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP TIME
VOLTAGERANGE Note.4
FREQUENCY RANGE
POWERFACTOR
EFFICIENCY(Typ.)
ACCURRENT
INPUT
INRUSHCURRENT(max.)
LEAKAGECURRENT
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERCURRENT Note.5
SHORTCIRCUIT
OVERVOLTAGE
12V 24V 48V
18~24V 36~48V
2.5A 1.3A
0~1.3A
0.63A
0~0.63A
30W 31.2W 30.24W
2Vp-p 2.4Vp-p
0.975~1.3A
4.8Vp-p
0.475~0.63A
10%
3.0%
5.0%
1200ms/230VAC22 atfullload00ms/115VAC
90~264VAC 127~370VDC
47~63Hz
PF>0.9at75~100%load ,115VAC/230VAC
83% 85.5% 86.5%
15~18V 28~33V 57~63V
0.4A/115VAC0.2A/230VAC
40A/230VAC
<0.75mA /240VAC
Protectiontype:Constantcurrentlimiting,recoversautomaticallyafterfaultconditionisremoved
Hiccupmode,recoversautomaticallyafterfaultconditionisremoved.
-30~+70 (Refertooutputloadderatingcurve)
20~95%RH non-condensing
-40~+80 ,10~95%RH
0.03%/ (0~50 )
10~500Hz,2G12min./1cycle,periodfor72min.eachalongX, Y,Zaxes
580.8Khrsmin.MIL-HDBK-217F(25 )
101.6*50.8*26.6mm(L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor, direct connecting
to LED's is not suggested for models with "RIPPLE & NOISE" > 10% and using additional drivers is highly recommended.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. Constant current operation region is within 75% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
0.12Kg;108pcs/13Kg/0.89CUFT
Features :
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
SAFETY STANDARDS
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
HARMONICCURRENT
EMSIMMUNITY
EMICONDUCTION&RADIATION
1.875~2.5A
100~110%
Protectiontype: Shutdowno/pvoltage,re-powerontorecover
30WSingleOutputLEDPowerSupply PLP-30 series
CONSTANTCURRENTOPERATIONVOLTAGE Note.5
9~12V
0~2.5A
SELV
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Built-in active PFC function
Cooling by free air convection
Output current level adjustab
100% full load burn-in test
High
Suitable for built-in applications of LED lighting
2 years warranty
reliability
I/P-O/P:3.75KVACI/P-FG:1.88KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC/25 /70%RH
Complianceto EN55015
Complianceto ClassC( 75%load);EN61000-3-3
EN61000-3-2
CompliancetoEN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024,EN61547,lightindustrylevel,criteria A
TUVEN61347-1,EN61347-2-13approved; esignrefertoUL60950-1d
FileName:PLP-30-SPEC2010-10-22
http://store.iiic.cc/